- 05000327/LER-1993-002-01, :on 930205,reactor Manually Tripped as Result of lock-up of Rod Control Sys.Caused by Problem in Rod Control Sys Circuitry.New I/O AC Amplifier Board Tested & Installed + (ML20034G589)
- ML20034G590 + (ML20034G590)
- 05000364/LER-1993-001, :on 930205,inadvertent Train a Safety Injection Occurred During Performance of FNP-2-STP-33.01 Due to Personnel Error.Individual Involved in Event Disciplined & All STP-33.0 Series Procedures Revised + (ML20034G591)
- 05000454/LER-1993-001-06, :on 930201,discovered Concern Re Potential Nonconservatism in Determining LTOP Sys Setpoints Used in TS & in Implementing Use of 10CFR50,App G Limits.Appropriate Procedures Will Be Revised + (ML20034G593)
- ML20034G595 + (ML20034G595)
- ML20034G597 + (ML20034G597)
- ML20034G599 + (ML20034G599)
- ML20034G602 + (ML20034G602)
- ML20034G603 + (ML20034G603)
- ML20034G606 + (ML20034G606)
- ML20034G607 + (ML20034G607)
- ML20034G608 + (ML20034G608)
- ML20034G610 + (ML20034G610)
- ML20034G612 + (ML20034G612)
- ML20034G613 + (ML20034G613)
- ML20034G615 + (ML20034G615)
- ML20034G617 + (ML20034G617)
- ML20034G618 + (ML20034G618)
- ML20034G623 + (ML20034G623)
- ML20034G624 + (ML20034G624)
- ML20034G625 + (ML20034G625)
- ML20034G626 + (ML20034G626)
- ML20034G628 + (ML20034G628)
- ML20034G629 + (ML20034G629)
- 05000324/LER-1993-001-02, :on 930205,reactor Bldg Roof Vent Radiation Monitor Declared Inoperable to Support Plant Mod Design Changes.Caused by Failure to Comply W/Procedural Requirements.Personnel Briefed + (ML20034G630)
- ML20034G631 + (ML20034G631)
- ST-HL-AE-4344, Annual Personnel Exposure Repts for 1992 for South Texas Project + (ML20034G632)
- ML20034G638 + (ML20034G638)
- ML20034G639 + (ML20034G639)
- ML20034G641 + (ML20034G641)
- ML20034G642 + (ML20034G642)
- ML20034G646 + (ML20034G646)
- ML20034G648 + (ML20034G648)
- ML20034G652 + (ML20034G652)
- ML20034G655 + (ML20034G655)
- ML20034G657 + (ML20034G657)
- ML20034G659 + (ML20034G659)
- ML20034G662 + (ML20034G662)
- ML20034G667 + (ML20034G667)
- ML20034G668 + (ML20034G668)
- 05000254/LER-1993-001-07, :on 930204,determined That Ccst Low Water Level & Torus High Water Level Switch Contacts Not Functionally Tested Due to Missed TS Sr.Maint Personnel Will Revise Check Valve Disassembly to Ensure Proper Alignment + (ML20034G670)
- ML20034G671 + (ML20034G671)
- ML20034G674 + (ML20034G674)
- ML20034G675 + (ML20034G675)
- ML20034G676 + (ML20034G676)
- ML20034G678 + (ML20034G678)
- ML20034G679 + (ML20034G679)
- ML20034G680 + (ML20034G680)