- ML20032C647 + (ML20032C647)
- ML20032C650 + (ML20032C650)
- L-81-470, Interim Deficiency Rept Re Failure to Follow Radiographic Procedures for safety-related Welds.Originally Reported on 810312.Date for Completion of Corrective Action Cannot Be Provided + (ML20032C653)
- ML20032C655 + (ML20032C655)
- ML20032C657 + (ML20032C657)
- PNO-II-81-092, on 811031,lost Dc Electrical Power to Two Control Room Annunciator Panels.Caused by Failed Resistor & Capacitor in Dc Inverter.Power Restored + (ML20032C659)
- A01907, Responds to 801031 & 0807 Requests for Performance of Simulator Exams as Operator License Condition.Simulator Exam Requirement Is Inappropriate & Unsafe + (ML20032C660)
- 05000338/LER-1981-075-03, /03L-0:on 811007 & 18,during Mode 4,both Power Operated Relief Valves Inoperable.Caused by Low Nitrogen Supply Pressure Resulting from Nitrogen Supply Sys Leakage. Temporary Supply Used & Vent Path Established + (ML20032C661)
- 05000339/LER-1981-068, Forwards LER 81-068/03L-0 + (ML20032C663)
- ML20032C665 + (ML20032C665)
- 05000324/LER-1981-003, Forwards LER 81-003/03L-0 + (ML20032C666)
- PNO-IV-81-026A, on 810924,util Decided to Reallocate Certain Responsibilities for Completion of Plants.Bechtel Will Probably Assume Responsibility for Engineering,Design & Const Mgt & Replace Brown & Root as Const Contractors + (ML20032C668)
- ML20032C669 + (ML20032C669)
- ML20032C670 + (ML20032C670)
- 05000339/LER-1981-068-03, /03L-0:on 810930,fire Door Reported to Have Been Nonfunctional for 6-day Period.On 811003,door Again Found Blocked Open.Caused by Failed Lock Assembly.Fire Watch Posted.Lock Replaced After Second Event + (ML20032C671)
- ML20032C674 + (ML20032C674)
- 05000324/LER-1981-003-03, /03L-0:on 810108,suppression Pool Level Exceeded Specs.Caused by Valve Operator Torque Switch Out of Adjustment Allowing Leakage Into Suppression Pool.Switch Repaired + (ML20032C675)
- ML20032C676 + (ML20032C676)
- ML20032C677 + (ML20032C677)
- 05000369/LER-1981-161, Forwards LER 81-161/01T-0.Detailed Event Analysis Encl + (ML20032C682)
- ML20032C684 + (ML20032C684)
- ML20032C685 + (ML20032C685)
- 05000259/LER-1981-057, Forwards LER 81-057/03L-0 + (ML20032C687)
- ML20032C689 + (ML20032C689)
- ML20032C691 + (ML20032C691)
- ML20032C693 + (ML20032C693)
- 05000369/LER-1981-161-01, /01T-0:on 811001,Rockbestos Coaxial Cable Found by Vendor to Fail to Meet Environ Qualification Criteria.Caused by Deterioration at High Temp as Determined by Ga Co. Replacement Cable Being Developed + (ML20032C694)
- ML20032C695 + (ML20032C695)
- 05000259/LER-1981-057-03, /03L-0:on 811004,hydrogen Dioxide Analyzer Sample Return Pump Found Inoperable.Caused by Loose Fan Damaging Windings.Motor Replaced + (ML20032C696)
- ML20032C697 + (ML20032C697)
- IR 05000285/1981027 + (ML20032C698)
- ML20032C699 + (ML20032C699)
- ML20032C700 + (ML20032C700)
- 05000369/LER-1981-162, Forwards LER 81-162/01T-0.Detailed Event Analysis Encl + (ML20032C701)
- 05000311/LER-1981-101, Forwards LER 81-101/03X-1.Detailed Event Analysis Encl + (ML20032C703)
- ML20032C705 + (ML20032C705)
- ML20032C708 + (ML20032C708)
- ML20032C709 + (ML20032C709)
- 05000369/LER-1981-162-01, /01T-0:on 810723,Westinghouse Notified Util of Generic Problem W/Differential Relays Not Passing Full Surge Withstand Requirements.Cause Not Stated.Mod Kits Available to Upgrade Surge Withstand Ability + (ML20032C710)
- ML20032C711 + (ML20032C711)
- 05000311/LER-1981-101-03, /03X-1:on 810906,due to Momentary Loss of Power & Failure of Backup Power Pack,Radiation Monitor 2R12A Setpoints,Warning,Failure & Alarm All Failed High.Caused by Failure of Batteries in Backup Power Pack + (ML20032C712)
- ML20032C713 + (ML20032C713)
- 1CAN108110, Restates 810707 & 1019 Positions on Degraded Grid Voltage Test Requirement.Addl Testing Not Justified on Safety or Cost/Benefit Basis + (ML20032C716)
- ML20032C717 + (ML20032C717)
- 05000309/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20032C718)
- ML20032C722 + (ML20032C722)
- 05000309/LER-1981-023-03, /03L-0:on 810930,monthly Composite Precipitation Analysis for Tritium for Sept 1981 Inadvertently Missed. Caused by Samples Being Inadvertently Disposed of Prior to Shipment Offsite for Analysis + (ML20032C723)
- ML20032C724 + (ML20032C724)
- 05000311/LER-1981-107, Forwards LER 81-107/03L-0.Detailed Event Analysis Encl + (ML20032C725)
- 05000333/LER-1981-072, Forwards LER 81-072/03L-0 + (ML20032C727)
- ML20032C729 + (ML20032C729)