List of results
- 05000325/LER-1982-109-03, /03L-0:on 821208,during Routine Surveillance, Outer Door of Reactor Bldg Secondary Containment Personnel Airlock Was Inoperable.Caused by Missing 2-inch Section of Door Gasket.Missing Section Replaced + (ML20028D250)
- 05000387/LER-1982-061, Forwards LER 82-061/01T-0 + (ML20028D252)
- ML20028D253 + (ML20028D253)
- ML20028D254 + (ML20028D254)
- ML20028D256 + (ML20028D256)
- 05000416/LER-1982-165, Forwards LER 82-165/03L-0 + (ML20028D257)
- ML20028D258 + (ML20028D258)
- RBG-14-093, Interim Deficiency Rept DR-30 Re Interpretation of Radiographs Performed by Bf Shaw Co.Approx 99% of Radiographs Reviewed & Defective Welds Identified in Nonconformance & Disposition 3098.Final Rept by 830315 + (ML20028D259)
- 05000321/LER-1982-100, Forwards LER 82-100/03L-0 + (ML20028D261)
- ML20028D262 + (ML20028D262)
- 05000387/LER-1982-062, Forwards LER 82-062/01T-0 + (ML20028D263)
- ML20028D264 + (ML20028D264)
- IR 05000329/1982023 + (ML20028D265)
- 05000416/LER-1982-165-03, /03L-0:on 821213,Divs I & II Diesels Declared Inoperable Due to Discovery of Unqualified Cable in Diesel Generator Control Circuitry.Caused by Vendor Notification That Cables Failed IEEE Flame Test.Controls Deemed Adequate + (ML20028D266)
- 05000321/LER-1982-100-03, /03L-0:on 821201,discovered 8 of 20 Newly Installed Cables Deliberately Cut.Caused by Vandalism by Person or Persons Unknown.Cables Repaired + (ML20028D270)
- ML20028D271 + (ML20028D271)
- 05000387/LER-1982-069, Forwards LER 82-069/03L-0 + (ML20028D274)
- ML20028D275 + (ML20028D275)
- ML20028D281 + (ML20028D281)
- IR 05000352/1982014 + (ML20028D284)
- ML20028D286 + (ML20028D286)
- 05000387/LER-1982-069-03, /03L-0:on 821207,during Startup Testing,Hpci Sys Declared Operable Prior to Closing Out Open Equipment Release Form.Caused by Work Program Design Weakness.Present Work Practice Modified + (ML20028D287)
- ML20028D289 + (ML20028D289)
- ML20028D290 + (ML20028D290)
- 05000029/LER-1982-044, Forwards LER 82-044/03L-0 + (ML20028D291)
- ML20028D294 + (ML20028D294)
- ML20028D295 + (ML20028D295)
- ML20028D297 + (ML20028D297)
- 05000361/LER-1982-153-03, /03L-0:on 821130,following Turbine Trip,Low Pressure Turbine Stop Valve 2UV-2200R Failed to Close.Caused by Excessive Galling Between Disc Stub Shafts & Casing Bore. Clearance Between Shaft & Bore Increased + (ML20028D299)
- IR 05000272/1982030 + (ML20028D300)
- 05000361/LER-1982-157-03, /03L-0:on 821124,samples from Control Room Emergency Air Cleanup Sys Train a Charcoal Absorber Failed to Satisfy Methyl Iodine Removal Capability.Caused by Activated Charcoal Degradation.Charcoal Replaced + (ML20028D301)
- 05000029/LER-1982-044-03, /03L-0:on 821208,continuous Flow Discovered Through Alarm Check Auxiliary Valve After Special Hazards Header Flow Alarm Received.Caused by Insufficient Seating Between Auxiliary Valve Seat & Disc.Valve Disc Replaced + (ML20028D302)
- 05000361/LER-1982-154-03, /03L-0:on 821130,following Turbine Trip,Low Pressure Turbine Stop Valve 2UV-2200R Failed to Close.Caused by Excessive Galling Between Disc Stub Shafts & Casing Bore. Clearance Between Shaft & Bore Increased + (ML20028D303)
- ML20028D305 + (ML20028D305)
- 05000387/LER-1982-072, Forwards LER 82-072/03L-0 + (ML20028D309)
- ML20028D310 + (ML20028D310)
- 05000387/LER-1982-072-03, /03L-0:on 821210,while Performing Surveillance, One Control Rod Would Not Indicate at One Position.Possibly Caused by Intermittent Fault on Circuit Board.Printed Circuit Board Reinstalled + (ML20028D314)
- ML20028D316 + (ML20028D316)
- 05000315/LER-1982-106, Forwards LER 82-106/03L-0 + (ML20028D317)
- ML20028D318 + (ML20028D318)
- 05000315/LER-1982-106-03, /03L-0:on 821209,discovered Fire Door 455 Blocked Open W/No Fire Watch Established.Cause Undetermined.Door Closed.Personnel Reminded of Responsibility Re Fire Doors + (ML20028D319)
- 05000395/LER-1982-056, Forwards LER 82-056/03L-0.Detailed Event Analysis Encl + (ML20028D321)
- ML20028D322 + (ML20028D322)
- 05000395/LER-1982-056-03, /03L-0:on 821209,surveillance Test Procedure, Nis Power Range Heat Balance, Not Performed in Specified Intervals.Caused by Personnel Oversight.Administrative Procedures for Control of Surveillances Revised + (ML20028D323)
- 05000416/LER-1982-163, Forwards LER 82-163/03L-0 + (ML20028D324)
- ML20028D325 + (ML20028D325)
- 05000416/LER-1982-163-03, /03L-0:on 821211,during Routine Power Supply Switching Operation,Both Shutdown Cooling Loops Isolated. Caused by Momentary Loss of Power to Rps.Shutdown Cooling Restored + (ML20028D326)
- ML20028D330 + (ML20028D330)
- ML20028D331 + (ML20028D331)
- 05000325/LER-1982-028-03, During Routine Surveillance,Comparison of RTGB Indications of Suppression Chamber Water Level Revealed 2.2-inch Level Difference. Caused by Loss of Trickle Flow Transmitter to Wet Ref Leg + (ML20028D332)
- ML20028D333 + (ML20028D333)