Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20024B762 + (ML20024B762)
- ML20024B763 + (ML20024B763)
- 05000237/LER-1983-045-03, /03L-0:on 830608,during Normal Operation,Circuit Breaker for Core Spray Injection Valve MO2-1402-25B Tripped. Caused by Incorrect Setting on Circuit Breaker,Due to Personnel Error.Breaker Set Correctly + (ML20024B764)
- IR 05000483/1983021 + (ML20024B765)
- ML20024B767 + (ML20024B767)
- ML20024B769 + (ML20024B769)
- ML20024B770 + (ML20024B770)
- 05000220/LER-1983-010-03, /03L-0:on 830524,core Topping Pump 121 Removed from Svc to Replace Packing.Caused by Air Leaking Due to Iltr Pressure Introduction in Pump.Packing Replaced & Pump Returned to Svc within 22 H + (ML20024B771)
- IR 05000334/1983011 + (ML20024B772)
- ML20024B774 + (ML20024B774)
- 05000395/LER-1983-058-03, /03L-0:on 830607,smoke Detector IXA-4993G Failed to Respond to Simulated Alarm.Caused by Broken Base Assembly in Detector Due to Open Circuit Preventing Alarm Condition. Component Replaced + (ML20024B776)
- ML20024B777 + (ML20024B777)
- ML20024B778 + (ML20024B778)
- IR 05000097/1983002 + (ML20024B779)
- 05000339/LER-1983-048-03, /03L-0:on 830606 & 17,intermediate Range Channels N35 & N36 High Neutron Flux Reactor Trip Setpoints Exceeded Tech Spec Requirements.Caused by Administrative Error. Setpoints Reduced + (ML20024B782)
- ML20024B784 + (ML20024B784)
- ML20024B785 + (ML20024B785)
- ML20024B788 + (ML20024B788)
- ML20024B789 + (ML20024B789)
- IR 05000271/1983001 + (ML20024B790)
- ML20024B792 + (ML20024B792)
- ML20024B794 + (ML20024B794)
- IR 05000247/1983013 + (ML20024B796)
- ML20024B797 + (ML20024B797)
- B10832, Final Part 21 Rept Re Potential Problems W/Loop Power Supply Card Heat Sinks of Westinghouse 7300 Process Protection Sys (SD-40).Initially Reported on 830602.Concurs W/Westinghouse Hardware Changes + (ML20024B798)
- ML20024B799 + (ML20024B799)
- ML20024B801 + (ML20024B801)
- IR 05000333/1983009 + (ML20024B802)
- IR 05000320/1983007 + (ML20024B805)
- ML20024B806 + (ML20024B806)
- JAFP-83-0656, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/83-09.Corrective Actions:Two Lost Torque Wrenches Will Be Calibr If Found,Calibr Records Located & Maint Calibr Program Rewritten + (ML20024B809)
- IR 05000166/1983001 + (ML20024B810)
- 05000389/LER-1983-025-03, /03L-0:on 830616,while in Mode 2 Startup & Filling 2A2 Safety Injection Tank,Relief Valve on Refueling Water Tank Return Header Lifted,Resulting in Loss of Pressure in 2B2.Caused by Open Manual Isolation Valve + (ML20024B811)
- ML20024B813 + (ML20024B813)
- 05000320/LER-1983-017-03, /03L-0:on 830527,reactor Bldg Water Level Instrumentation Indication Unchanged All Wk Despite Addition of 24,000 Gallons of Water.Caused by Improper Seating of Level Instrument Equalizing Valve + (ML20024B814)
- 05000317/LER-1983-022-03, Oyster Samples Collected During First Quarter 1983 from Camp Canoy Location Showed Ag-110m to Be 464 Plus/Minus 41 Pci/Kg (Wet).Caused by Oysters to Bioconcentrating Environ Silver + (ML20024B815)
- 05000309/LER-1983-022-01, /01T-0:during Survey of Safety Class Piping, Certain Sections of ECCS Piping Found W/Lead Shielding Installed W/O Engineering Evaluation of Seismic Qualification Impact.Administrative Measures Developed + (ML20024B816)
- 05000334/LER-1983-018-03, /03L-0:on 830527,OST 1.16.5 (Monthly Fuel Bldg Ventilation Sys Verification) Not Performed Since 830308. Caused by Failing to Schedule Test in Apr & May.Ost Performed Satisfactorily + (ML20024B817)
- ML20024B818 + (ML20024B818)
- 05000320/LER-1983-015-03, /03L-0:on 830527,one Halon Bottle Found W/Low Pressure & Low Weight During Surveillance of Air Intake Tunnel Halon Sys.Caused by Development of Leak in Bottle or Fittings.Bottle Replaced + (ML20024B819)
- ML20024B820 + (ML20024B820)
- ML20024B821 + (ML20024B821)
- ML20024B822 + (ML20024B822)
- 05000317/LER-1983-029-03, /03L-0:on 830524,during Normal Operation, Surveillance Testing Indicated Neither Spent Fuel Pool Exhaust Fans 11 or 12 Would Maintain Required Negative Pressure.Caused by Clogged HEPA Filters + (ML20024B823)
- ML20024B824 + (ML20024B824)
- ML20024B825 + (ML20024B825)
- ML20024B826 + (ML20024B826)
- IR 05000220/1983011 + (ML20024B829)
- ML20024B830 + (ML20024B830)
- PNO-I-83-074, on 830704 & 05,unit Voluntarily Shut Down for Addl NDE of Recirculation & RHR Piping Welds.Addl Exams Being Made by NDE Team from Separate Vendor Organization. Subsequent Licensee Actions Being Discussed + (ML20024B831)
- 05000293/LER-1983-030-03, /03L-0:on 830527,both HPCI Area Smoke Detection Sys Alarmed in Main Control Room.Caused by Valve A02301-31 Steam Leak Causing False Indications.Valve Repaired + (ML20024B832)