- 05000220/LER-1981-030-03, /03L-0:on 810630,all Emergency Condenser Vent Monitors Exceeded Upscale Trip Setpoint During Calibr. Caused by Difference in Response Between Test Signal & Actual Signal.Procedure Revised + (ML20009H617)
- ML20009H620 + (ML20009H620)
- ML20009H621 + (ML20009H621)
- 05000309/LER-1981-014, Forwards LER 81-014/01T-0 + (ML20009H622)
- 05000325/LER-1981-056, Forwards LER 81-056/03L-0 + (ML20009H624)
- ML20009H625 + (ML20009H625)
- 05000325/LER-1981-056-03, /03L-0:on 810706,RHR Svc Water Pump 1A Experienced Excess Vibration.Caused by Abnormal Bearing Wear from Water in Pump Bearing.Bearings Replaced + (ML20009H628)
- 05000309/LER-1981-014-01, /01T-0:on 810719,containment Isolation Sys Valve on Alternate Letdown Sys Failed Open.Caused by Packing Being Too Tight on Valve.Valve Repaired & Tested + (ML20009H631)
- 05000321/LER-1981-067, Forwards LER 81-067/03L-0 + (ML20009H632)
- ML20009H633 + (ML20009H633)
- 05000324/LER-1981-062, Forwards LER 81-062/03L-0 + (ML20009H634)
- ML20009H635 + (ML20009H635)
- 05000280/LER-1981-017-03, /03L-0:on 810702,discovered That No Fire Watch Had Been Posted for Two Unsealed Fire Barrier Penetrations in Cable Spreading Room Area.Caused by Const Personnel Error. Fire Watch Posted & Seal Installed + (ML20009H637)
- 05000321/LER-1981-067-03, /03L-0:on 810704,discharge Check Valve E11-F005B Failed to Close After Surveillance Procedure.Caused by Excessive Wear at Point Disc Supported by Disc Hanger.Valve Repaired,Sys Retested & Returned to Svc + (ML20009H638)
- 05000324/LER-1981-062-03, /03L-0:on 810704,control Rod Failed to Have Full in Position Indication Lights Lit When Fully Inserted.Caused by Failed Reed Switch Located in Drywell.Switch to Be Repaired During Future Outage + (ML20009H639)
- ML20009H640 + (ML20009H640)
- ML20009H641 + (ML20009H641)
- ML20009H642 + (ML20009H642)
- 05000280/LER-1981-018-03, Ler 81-018/03L-0:on 810702,power Operated Relief Valves Lifted to Mitigate Overpressurization Transient.Caused by Unisolated Charging Flow Control Valve.Valve Isolated. RCS Pressure Reduced Below Setpoint + (ML20009H643)
- 05000259/LER-1981-035, Forwards Updated LER 81-035/03X-1 + (ML20009H644)
- ML20009H645 + (ML20009H645)
- IR 05000443/1981007 + (ML20009H646)
- 05000304/LER-1981-015, Forwards LER 81-015/99X-0 + (ML20009H648)
- ML20009H650 + (ML20009H650)
- 05000259/LER-1981-035-03, Left Bank Starters Would Not Develop Min Rotational Speed During Testing.Caused by Normal Wear,Dirt & Grit in Air Start Sys.Air Start Motor Replaced + (ML20009H651)
- 05000304/LER-1981-015-99, /99X-0:on 810507,unit Safety Injected,Causing PI-526A & 536A to Fail Low.Caused by Master Inverter Output Sola Transformer Shorting to Ground,Tripping Inverter 213 & Slave Transformer Burning Up.Circulating Current Minimized + (ML20009H652)
- ML20009H653 + (ML20009H653)
- 05000327/LER-1981-085, Forwards LER 81-085/01T-0 + (ML20009H654)
- ML20009H655 + (ML20009H655)
- ML20009H656 + (ML20009H656)
- ML20009H657 + (ML20009H657)
- ML20009H658 + (ML20009H658)
- 05000327/LER-1981-085-01, /01T-0:on 810719,outer Door to Lower Containment Personnel Access Lock Opened While Inner Door Was Ajar. Caused by Excessive Slack in Door Operating Linkage Which Allowed Inner Door to Bounce Open + (ML20009H659)
- ML20009H660 + (ML20009H660)
- ML20009H661 + (ML20009H661)
- ML20009H662 + (ML20009H662)
- ML20009H663 + (ML20009H663)
- ML20009H664 + (ML20009H664)
- ML20009H666 + (ML20009H666)
- ML20009H667 + (ML20009H667)
- 05000280/LER-1981-024-03, /03L-0:on 810701,fire Seal in Penetration Not Restored & Fire Watch Not Maintained Following Installation of New Cables.Caused by Const Personnel Error.Fire Barrier Sealed.Const Personnel Reinstructed + (ML20009H668)
- ML20009H669 + (ML20009H669)
- ML20009H672 + (ML20009H672)
- FVY-81-109, Submits Proposed Change 97 to Amend Tech Specs of License DPR-28 to Reflect Proposed Organizational Structure of Facility + (ML20009H674)
- ML20009H675 + (ML20009H675)
- 05000280/LER-1981-045-03, /03L-0:on 810703,BIT Recirculation Valves Closed. Caused by Isolation of Instrument Air to Auxiliary Bldg to Avert Reactor Trip.Air Line Break Isolated & Auxiliary Bldg Instrument Air Restored,Reopening Valves + (ML20009H676)
- TXX-3379, Submits Status of Procedures Required by NUREG-0737 TMI Action Plan Items I.C.2,I.C.3,I.C.4,I.C.5 & I.C.6 + (ML20009H677)
- ML20009H679 + (ML20009H679)
- ML20009H683 + (ML20009H683)
- ML20009H684 + (ML20009H684)
- ML20009H687 + (ML20009H687)