- 05000369/LER-1981-074, Forwards LER 81-074/03L-0.Detailed Event Analysis Encl + (ML20009F621)
- ML20009F622 + (ML20009F622)
- ML20009F623 + (ML20009F623)
- ML20009F624 + (ML20009F624)
- 05000369/LER-1981-074-03, /03L-0:on 810429,inadvertent Safety Injection Initiated on Train a When Solid State Protection Sys Logic Cabinets Were Returned to Svc W/O Blocking Injection Signals During Initial Fuel Load.Caused by Mods to Cabinets + (ML20009F625)
- 05000364/LER-1981-022-03, /03L-0:on 810603,recombiner Oxygen Outlet Analyzer a Found Not Responding to Changes in Oxygen Concentration. Probably Caused by Serviceman Failure to Place Analyzer in Measure Mode Following Performance of Alignment Procedu + (ML20009F626)
- ML20009F627 + (ML20009F627)
- 05000364/LER-1981-023-03, /03L-0:on 810604,boric Acid Storage Sys Declared Inoperable Due to Low Concentration in Boric Acid Tank 2A & Low Vol of Solution in Tank 2B.Caused by Prior Use of Sys for Boration & Personnel Error + (ML20009F628)
- 05000321/LER-1981-057, Forwards LER 81-057/03L-0 + (ML20009F629)
- ML20009F630 + (ML20009F630)
- 05000369/LER-1981-077, Forwards LER 81-077/01T-0.Detailed Event Analysis Encl + (ML20009F631)
- ML20009F632 + (ML20009F632)
- ML20009F633 + (ML20009F633)
- 05000364/LER-1981-025-03, /03L-0:on 810604,steam Jet Air Ejector Noble Gas Activity Monitor RE-15 Failed Low.Caused by Faulty Connection at Detector.Condition Corrected & Monitor Returned to Svc on 810615 + (ML20009F634)
- 05000369/LER-1981-095, Forwards LER 81-095/03L-0 + (ML20009F635)
- ML20009F636 + (ML20009F636)
- 05000369/LER-1981-077-01, /01T-0:on 810521,ASME Code Rejectable Indications Found in Vendor Seal Plate to Door Frame Welds During Nondestructive Exam of Personnel Lock Shim Plate Welds. Caused by Use of Seal Rather than Structural Welds + (ML20009F637)
- 05000335/LER-1981-027, Forwards LER 81-027/03L-0 + (ML20009F638)
- ML20009F639 + (ML20009F639)
- ML20009F640 + (ML20009F640)
- ML20009F641 + (ML20009F641)
- 05000369/LER-1981-082, Forwards LER 81-082/03L-0 + (ML20009F642)
- ML20009F643 + (ML20009F643)
- 05000321/LER-1981-057-03, /03L-0:on 810611,temporary Change to HNP-1-6907 (Reactor Core Isolation Cooling Pump Suction Hydro) Found Not Approved by Mgt within Reguired Time.Caused by Personnel Failure to Maintain Adequate Control Over Procedure + (ML20009F644)
- 05000369/LER-1981-095-03, /03L-0:on 810606,flow Rate Measurement Instrumentation on Waste Monitor Tank a Declared Inoperable During Attempted Liquid Water Release.Caused by Supply Air Isolation Valve to Transmitter Left Closed Following Maint + (ML20009F646)
- 05000348/LER-1981-044-03, /03L-0:on 810610,diesel Generator 1C Declared Inoperable During Test FNP-1-STP-28.1.Caused by Overvoltage Condition Due to Damaged Voltage Regulator Circuitry Resulting from Failed Engine Running Relay + (ML20009F647)
- 05000335/LER-1981-027-03, /03L-0:on 810519,while Cleaning Condenser Water Boxes,Control Element Assembly 65 Dropped While Being Inserted.Cause Unknown.Assembly Returned to Group Position + (ML20009F648)
- 05000369/LER-1981-082-03, /03L-0:on 810504-22,fire Detection Sys Found Inoperable.Caused by Const in Area.Fire Watches & Patrols Established + (ML20009F649)
- ML20009F650 + (ML20009F650)
- ML20009F652 + (ML20009F652)
- 05000339/LER-1981-054, Forwards LER 81-054/03L-0 + (ML20009F653)
- ML20009F654 + (ML20009F654)
- 05000348/LER-1981-045-03, /03L-0:on 810613,train Svc Water Loop a Declared Inoperable.Caused by Inoperable Emergency Recirculation Valve Due to Blown Control Circuit Fuse.Fuse Replaced,Valve Tested & Loop Returned to Svc on 810613 + (ML20009F655)
- 05000260/LER-1981-031, Forwards LER 81-031/03L-0 + (ML20009F656)
- ML20009F657 + (ML20009F657)
- ML20009F658 + (ML20009F658)
- ML20009F659 + (ML20009F659)
- ML20009F660 + (ML20009F660)
- 05000366/LER-1981-065, Forwards LER 81-065/03L-0 + (ML20009F661)
- ML20009F662 + (ML20009F662)
- 05000260/LER-1981-034, Forwards LER 81-034/03L-0 + (ML20009F663)
- ML20009F664 + (ML20009F664)
- 05000339/LER-1981-054-03, /03L-0:on 810629,train J of Onsite Ac Power Sys Discovered Not Tested Per Tech Specs Since 790316.Caused by Mistaken Impression That Both Buses Were Retested on 800331.Emergency Bus J Tested on 800331 + (ML20009F665)
- ML20009F666 + (ML20009F666)
- 05000260/LER-1981-031-03, /03L-0:on 810701,RHR Pump Room Cooler 3-A Developed Water Leak.Caused by Broken Silfos Joint on 1/4-inch Vent Line.Joint Resoldered + (ML20009F667)
- 05000260/LER-1981-034-03, /03L-0:on 810630,RHR Svc Water Pumps B2,D-1 & D-2 Were Not in Svc.Caused by Removing B2 from Svc to Change Motor Oil & Tagging Closed Crosstie Valve to Unit 1, FCV-1-74-100.Oil Changed + (ML20009F668)
- ML20009F669 + (ML20009F669)
- ML20009F671 + (ML20009F671)
- 05000302/LER-1981-039, Forwards LER 81-039/03L-0 + (ML20009F672)
- ML20009F673 + (ML20009F673)
- ML20009F674 + (ML20009F674)