ML20009F624

From kanterella
Jump to navigation Jump to search
Forwards LERs 81-022/03L-0,81-023/03L-0 & 81-025/03L-0
Date released: 01/23/2020 Download: ML20009F624


LER 81-025/03L-0:on 810604,steam Jet Air Ejector Noble Gas Activity Monitor RE-15 Failed Low.Caused by Faulty Connection at Detector.Condition Corrected & Monitor Returned to Svc on 810615
ML20009F634
Person / Time
Site: Farley 
Issue date: 07/07/1981
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F634 (1)
LER 81-023/03L-0:on 810604,boric Acid Storage Sys Declared Inoperable Due to Low Concentration in Boric Acid Tank 2A & Low Vol of Solution in Tank 2B.Caused by Prior Use of Sys for Boration & Personnel Error
ML20009F628
Person / Time
Site: Farley 
Issue date: 07/07/1981
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F628 (2)
LER 81-022/03L-0:on 810603,recombiner Oxygen Outlet Analyzer a Found Not Responding to Changes in Oxygen Concentration. Probably Caused by Serviceman Failure to Place Analyzer in Measure Mode Following Performance of Alignment Procedures
ML20009F626
Person / Time
Site: Farley 
Issue date: 07/07/1981
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F626 (1)
Forwards LERs 81-022/03L-0,81-023/03L-0 & 81-025/03L-0
ML20009F623
Person / Time
Site: Farley 
Issue date: 07/07/1981
From: Clayton F
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F623 (1)