- 05000366/LER-1981-053, Forwards LER 81-053/03L-0 + (ML20009F535)
- ML20009F537 + (ML20009F537)
- FVY-81-107, Forwards Proprietary rept,YAEC-1265P, Methods for Analysis of Oxide Fuel Rod,Steady-State Thermal Effects (Frosstey) Code Qualification & Application. Affidavit Encl.Rept Withheld (Ref 10CFR2.790) + (ML20009F538)
- ML20009F539 + (ML20009F539)
- 05000366/LER-1981-053-03, /03L-0:on 810611,turbine First State Pressure Permissive Switches Found Out of Tolerance While Performing Barksdale Pressure Switch Calibr.Probably Caused by Setpoint Drift.Switches Recalibr + (ML20009F540)
- 05000029/LER-1981-013, Forwards LER 81-013/03L-0 + (ML20009F542)
- 05000029/LER-1981-013-03, /03L-0:on 810616,O Ring Seals on Penetrations Failed to Hold Pressure.Caused by Loose Bolting on Penetration Flanges.Bolts Retightened & Penetrations Retested + (ML20009F544)
- 05000321/LER-1981-053, Forwards LER 81-053/03L-0 + (ML20009F545)
- ML20009F546 + (ML20009F546)
- ML20009F547 + (ML20009F547)
- 05000321/LER-1981-053-03, /03L-0:on 810610,drywell & Torus Temp Recorder 1T47-R612 Found Marking Erratically.Caused by Component Failure Due to Balancing Motor Failure.Component Replaced + (ML20009F548)
- AECM-81-226, Status Rept 1 on Deficiency Re Temp Flex Penetration Bellows Assemblies,Initially Reported on 810529.Vendor Has Been Requested to Prepare Written Calculations to Verify Min Weld Requirements for Design Seismic Conditions + (ML20009F549)
- 05000327/LER-1981-075, Forwards LER 81-075/03L-0 + (ML20009F550)
- ML20009F551 + (ML20009F551)
- ML20009F552 + (ML20009F552)
- 05000327/LER-1981-075-03, /03L-0:on 810623,found Sufficient Clearance Did Not Exist Between Alternate Charging Line from Regenerative Heat Exchanger to Reactor Coolant Loop 4.Caused by Inadequate Original Drawings + (ML20009F553)
- ML20009F554 + (ML20009F554)
- ML20009F555 + (ML20009F555)
- ML20009F556 + (ML20009F556)
- 05000259/LER-1981-036, Forwards LER 81-036/03L-0 + (ML20009F557)
- ML20009F558 + (ML20009F558)
- ML20009F559 + (ML20009F559)
- 05000259/LER-1981-036-03, /03L-0:on 810619,during Biaxial Seismic Switch Tests,Seismic Trigger Hst a Failed to Operate.Caused by Relay Transistor Failure Due to Moisture Condensation Inside Housing.Trigger Repaired + (ML20009F560)
- 05000321/LER-1981-050, Forwards LER 81-050/03L-0 + (ML20009F561)
- ML20009F562 + (ML20009F562)
- ML20009F563 + (ML20009F563)
- ML20009F564 + (ML20009F564)
- ML20009F565 + (ML20009F565)
- 05000321/LER-1981-050-03, /03L-0:on 810612,while Performing RHR Valve Operability,Containment Spray Isolation Valve B Found Inoperative.Caused by Incorrect Installation of Motor Pinion Gear.Motor Pinion Gear Reinstalled + (ML20009F566)
- ML20009F567 + (ML20009F567)
- ML20009F568 + (ML20009F568)
- ML20009F569 + (ML20009F569)
- ML20009F570 + (ML20009F570)
- 05000321/LER-1981-056, Forwards LER 81-056/03L-0 + (ML20009F571)
- ML20009F572 + (ML20009F572)
- 05000321/LER-1981-056-03, /03L-0:on 810610,during Startup,Offgas Hydrogen Analyzer 1N62-N009A Was Reported Inoperative.Caused by Personnel Error.Root Valve N62-F064 a Was Found Closed. Valve Opened + (ML20009F573)
- ML20009F574 + (ML20009F574)
- ML20009F575 + (ML20009F575)
- ML20009F576 + (ML20009F576)
- ML20009F577 + (ML20009F577)
- ML20009F578 + (ML20009F578)
- ML20009F580 + (ML20009F580)
- ML20009F581 + (ML20009F581)
- ML20009F582 + (ML20009F582)
- ML20009F583 + (ML20009F583)
- ML20009F585 + (ML20009F585)
- ML20009F586 + (ML20009F586)
- L-81-288, Deficiency Rept,Originally Reported on 810610,re Linear Indications in Reactor Coolant Pump 2A1 Volute.Further Info Needed Re Size & Depth of Excavations Required to Remove Linear Indications.Final Rept Will Be Submitted 810810 + (ML20009F587)
- L-81-249, Interim Deficiency Rept,Originally Reported on 810312,re Failure to Follow Established Procedure When Interpreting Radiographs of safety-related Welds.Required Repair Work Not Yet Completed.Final Rept Delayed Until 810731 + (ML20009F588)
- ML20009F589 + (ML20009F589)
- 05000335/LER-1981-031, Forwards LER 81-031/03L-0 + (ML20009F591)