TENNESSEE VALLEY AdiHdRIT:Y3 1)f,FICIALCOJT CH ATTANOOGA, TENNESSEE 37401 400 Chestnut Street Tower II June 30, 1 1'5 ?Il l A 0. gy HTRD-50-518, -519, -520, -521/81-04 (b

PBRD-50-553/81-06, -554/81-04 S f @

9 N

Mr. James P. O'Reilly, Director S

y; g

d jl}L30 [Bg g j

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission D.,,,,,ucug l-7/

Region II - Suite 3100 7

101 Marietta Street Atlanta, Georgia 30303 C,

%Lhn.

h

Dear Mr. O'Reilly:

  1. kd HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS - COMPLETION OF AS-BUILT DRAWINGS - HTRD-50-518, -519, -520, -521/81-04 AND PBRD-50-553/81-06, -554/81-04 The subject deficiencies were initially reported to NRC-OIE, Region II, Inspector R. W. Wright on January 22, 1981, as NCR's HTN-M30-10 and PBN-M80-10, deficiency Nos. 13, 14, and 21. The first and second interim reports were submitted on February 23 and April 1, 1981.

In compliance with paragraph 50.55(e) of 10 CFR Part 50, this letter constitutes the third interim report on the subject deficiencies.

Corrective actions have been proposed by TVA and are being submitted to GE for concurrence. As a result, we anticipate transmitting an additional report on or before December 15, 1981.

If you have any questions, please call Jim Demer at FTS 857-2014.

Very truly yours, NNESSEE VALLEY AUTHORITY

\\

L. M. Mills, Mahager Nuclear Regulation and Safety cc:

Mr. Victor Stello, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 l

l

+{,

8107310333 810630 PDR ADOCK 05000518 i

S PDR An Equal Opportunity Employer

)