Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20008F957 + (ML20008F957)
- 05000366/LER-1981-040, Forwards LER 81-040/03L-0 + (ML20008F958)
- ML20008F959 + (ML20008F959)
- ML20008F960 + (ML20008F960)
- ML20008F961 + (ML20008F961)
- 05000366/LER-1981-028-03, /03L-0:on 810407,during Steady State Operation, Electrolyte Level in Some Cells of 2R42-S001A & B Station Batteries & 2R42-S002A Diesel Generator Battery Found Above High Level Mark.Caused by Personnel & Procedure Errors + (ML20008F962)
- 05000366/LER-1981-040-03, /03L-0:on 810423,hydraulic Control Unit Accumulator Low Pressure Alarm Annunciated for Rod 46-23. Caused by Accumulator Pressure Having Bled Down Below Tech Spec Level.Accumulator Recharged & Restored + (ML20008F963)
- 05000366/LER-1981-029, Forwards LER 81-029/03L-0 + (ML20008F964)
- ML20008F965 + (ML20008F965)
- ML20008F966 + (ML20008F966)
- 05000254/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20008F967)
- ML20008F968 + (ML20008F968)
- 05000366/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20008F969)
- ML20008F970 + (ML20008F970)
- 05000366/LER-1981-029-03, /03L-0:on 810408,during 100% Power,Rcic Inboard Steam Supply Isolation Valve Could Not Be Reopened After Closing on Isolation Signal.Caused by Excessive Activation & Tripped Breaker.Breaker Reset & Valve Tested + (ML20008F971)
- 05000254/LER-1981-009-03, /03L-0:on 810407,while 1A RHR Svc Water Pump Being Run for Packing Adjustment,Pump Failed to Meet Flow Requirements of 3,500 Gpm at 198 Psig.Caused by 3 Pieces of Wood in Pump Suction.Packing Sleeve & Bearings Replaced + (ML20008F972)
- ML20008F973 + (ML20008F973)
- 05000366/LER-1981-032-03, /03L-0:on 810410,HPCI Auxiliary Oil Pump Tripped During Second HPCI Sys Manual Initiation.Caused by Coil Failure in Time Delay Relay Not Allowing Relay Contact.Coil Replaced,Pump Rerun & Design Change Initiated + (ML20008F974)
- ML20008F975 + (ML20008F975)
- ML20008F976 + (ML20008F976)
- ML20008F978 + (ML20008F978)
- ML20008F979 + (ML20008F979)
- ML20008F980 + (ML20008F980)
- ML20008F982 + (ML20008F982)
- ML20008F983 + (ML20008F983)
- ML20008F984 + (ML20008F984)
- ML20008F985 + (ML20008F985)
- 05000366/LER-1981-030, Forwards LER 81-030/03L-0 + (ML20008F986)
- ML20008F987 + (ML20008F987)
- ML20008F988 + (ML20008F988)
- ML20008F989 + (ML20008F989)
- 05000366/LER-1981-030-03, /03L-0:on 810413,valve Position Indicating Lights for Recirculation Pump B Discharge valve,2B31-F031B,found Extinguished.Caused by Blown Fuse in Control Circuit. Integrity of Circuit Verified & Fuse Replaced + (ML20008F990)
- 05000254/LER-1981-010, Forwards LER 81-010/03L-0 + (ML20008F991)
- ML20008F992 + (ML20008F992)
- 05000254/LER-1981-010-03, /03L-0:on 810414,valve AO-1-1301-35 Observed Closed Causing Reactor Core Isolation Cooling to Be Inoperable.Caused by Shorted Solenoid Coil on Valve Operator.Solenoid Replaced.Valve Tested Satisfactorily + (ML20008F993)
- ML20008F994 + (ML20008F994)
- ML20008F995 + (ML20008F995)
- ML20008F996 + (ML20008F996)
- ML20008F997 + (ML20008F997)
- ML20008F998 + (ML20008F998)
- ML20008G002 + (ML20008G002)
- ML20008G003 + (ML20008G003)
- ML20008G005 + (ML20008G005)
- ML20008G006 + (ML20008G006)
- ML20008G007 + (ML20008G007)
- ML20008G008 + (ML20008G008)
- IR 05000338/1981004 + (ML20008G009)
- ML20008G010 + (ML20008G010)
- ML20008G011 + (ML20008G011)
- ML20008G013 + (ML20008G013)
- IR 05000518/1981005 + (ML20008G015)