- 05000324/LER-1980-092-03, /03L-0:on 801106,08,12,15,18,22 & 23,containment Atmospheric Monitor 2-CAC-AT-1259,Beckman Model F3,tripped Due to Loss of Sample Flow.Caused by Water Accumulation in Torus Sample Line to Monitor.Water Removed + (ML20002B024)
- 05000213/LER-1980-016, Forwards LER 80-016/03L-0 + (ML20002B025)
- ML20002B027 + (ML20002B027)
- 05000213/LER-1980-016-03, /03L-0:on 801118,audible & Visual Alarms Indicated Two Dropped Rods & Initiation of Turbine Load Runback.Caused by Badly Burnt Arc Chute & Auxiliary Contacts on One Side of Type MM310 Contactor Rubbing & Impeding Operation + (ML20002B028)
- 05000409/LER-1980-016, Forwards LER 80-016/01T-0 + (ML20002B029)
- 05000409/LER-1980-016-01, /01T-0:on 801202,hourly Fire Watch Patrol Not Established within 1-h of Drilling Holes Through Turbine Bldg Barriers for Fire Protection & Sampling Sys.Job Coordinators Reminded of Fire Barrier Requirements + (ML20002B031)
- ML20002B032 + (ML20002B032)
- ML20002B034 + (ML20002B034)
- 05000282/LER-1980-036, Forwards LER 80-036/03L-0 + (ML20002B035)
- ML20002B036 + (ML20002B036)
- ML20002B038 + (ML20002B038)
- 05000321/LER-1980-117, Forwards LER 80-117/03L-0 + (ML20002B039)
- ML20002B040 + (ML20002B040)
- 05000346/LER-1980-080, Forwards LER 80-080/03L-0 + (ML20002B041)
- ML20002B042 + (ML20002B042)
- 05000282/LER-1980-036-03, /03L:on 801105,battery Charger 12 Failed to Provide Normal Output.Caused by Firing Card B Not Providing Pulses to Fire B Phase Scr.Card Replaced + (ML20002B043)
- 05000320/LER-1980-049, Forwards LER 80-049/01L-0 + (ML20002B044)
- 05000321/LER-1980-117-03, /03L-0:on 801104,no Transfer Authorizations Discovered for Receipt of Two Shipments of Low Power Range Monitors & One Shipment of Source Range & Radiation Monitors.Caused by Misinterpretation of Procedures + (ML20002B046)
- ML20002B047 + (ML20002B047)
- 05000346/LER-1980-080-03, /03L-0:on 801103,during Testing,Control Rod Drive Trip Breaker C Did Not Trip.Cause Could Not Be Determined. Breaker Was Manually Put in Tripped Position within 5 Minutes of Failure + (ML20002B048)
- ML20002B050 + (ML20002B050)
- 05000334/LER-1980-087, Forwards LER 80-087/03L-0 + (ML20002B051)
- ML20002B052 + (ML20002B052)
- 05000312/LER-1980-046, Forwards LER 80-046/03L-0 + (ML20002B053)
- 05000334/LER-1980-087-03, /03L-0:on 801113,operator Attempted to Perform Operation Surveillance Test on Intermediate Range Nuclear Instrument While Reactor Was Critical.Caused by Operator Error & Possible Inadequate Situational Analysis Guidance + (ML20002B055)
- ML20002B056 + (ML20002B056)
- 05000320/LER-1980-049-01, /01L-0:on 801027,ASME Code Stamped UV Valve LTB-V171 Discovered Stamped by Unauthorized Valve Supply House.Caused by Unauthorized Use of ASME UV Code Stamp by North American Safety Valve Industries,Inc + (ML20002B058)
- 05000306/LER-1980-035, Forwards LER 80-035/03L-0 + (ML20002B060)
- ML20002B063 + (ML20002B063)
- ML20002B064 + (ML20002B064)
- 05000312/LER-1980-046-03, /03L-0:on 801104 & 1128,overspeed Trip Lever on Turbine for Automatic Feedwater Pump P-318 Was Found in Apparent Tripped Condition.Cause Could Not Be Determined. Daily Visual Checks Initiated + (ML20002B065)
- ML20002B066 + (ML20002B066)
- 05000338/LER-1980-097, Forwards LER 80-097/03L-0 + (ML20002B067)
- ML20002B068 + (ML20002B068)
- 05000306/LER-1980-035-03, /03L-0:on 801103,remote/local Control Switch on Containment Spray Pump 21 Found Not in Remote Position. Caused by Contractor Workman Bumping Switch.Switch Returned to Remote Position + (ML20002B069)
- ML20002B070 + (ML20002B070)
- ML20002B074 + (ML20002B074)
- 05000338/LER-1980-097-03, /03L-0:on 801114,while Operating in Mode 1,LI-1474 Indicated Greater than 5% Higher than Average of Three Channels.Caused by High Transmitter Output,Due to Leaking Isolation Valve.Valves Furmanited.Channel Check Performed + (ML20002B075)
- ML20002B076 + (ML20002B076)
- ML20002B077 + (ML20002B077)
- ML20002B078 + (ML20002B078)
- ML20002B079 + (ML20002B079)
- ML20002B080 + (ML20002B080)
- ML20002B081 + (ML20002B081)
- ML20002B082 + (ML20002B082)
- 05000265/LER-1980-030-03, /03L-0:on 801031,primary Containment Valve AO-2-1601-63 Required 30-s to Close.Caused by Malfunction of Pilot Solenoid SO-2-1601-71.Solenoid Replaced & Tested + (ML20002B083)
- ML20002B084 + (ML20002B084)
- ML20002B085 + (ML20002B085)
- ML20002B086 + (ML20002B086)
- ML20002B089 + (ML20002B089)
- ML20002B090 + (ML20002B090)