ML20002B074

From kanterella
Jump to navigation Jump to search
Forwards LER 80-030/03L-0
Date released: 01/16/2020 Download: ML20002B074


LER 80-030/03L-0:on 801031,primary Containment Valve AO-2-1601-63 Required 30-s to Close.Caused by Malfunction of Pilot Solenoid SO-2-1601-71.Solenoid Replaced & Tested
ML20002B083
Person / Time
Site: Quad Cities 
Issue date: 11/20/1980
From: Robert Murray
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20002B083 (2)
Forwards LER 80-030/03L-0
ML20002B072
Person / Time
Site: Quad Cities 
Issue date: 11/20/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20002B072 (1)