- 05000324/LER-1981-019-03, /03L-0:on 810214,RHR Shutdown Cooling Supply Inboard Isolation valve,2-E11-F009,would Not Open from Rtgb.Caused by Burned Valve Motor Windings.Motor,Model SMB3, Rewound & Reinstalled + (ML19350B790)
- 05000366/LER-1980-139, Forwards Updated LER 80-139/01X-1 + (ML19350B791)
- ML19350B792 + (ML19350B792)
- ML19350B793 + (ML19350B793)
- ML19350B794 + (ML19350B794)
- 05000366/LER-1980-149, Forwards Updated LER 80-149/03X-1 + (ML19350B795)
- ML19350B796 + (ML19350B796)
- ML19350B797 + (ML19350B797)
- 05000366/LER-1980-139-01, Ae Advised That Drywell Equipment Drain Sump Discharge to Radwaste Piping Not Seismic Beyond Inboard Isolation Valve.Caused by Installation Error on Anchor 2G11-RAD-A90.Restraint Added + (ML19350B798)
- ML19350B799 + (ML19350B799)
- ML19350B800 + (ML19350B800)
- ML19350B801 + (ML19350B801)
- ML19350B802 + (ML19350B802)
- ML19350B806 + (ML19350B806)
- 05000366/LER-1980-149-03, RHR Pump Suction Isolation Valve 2E11-F4B Was Found Leaking.Caused by Scratches on Valve Seat,Probably Due to Valve Closing on Debris.Valve Seat Polished + (ML19350B807)
- ML19350B808 + (ML19350B808)
- ML19350B810 + (ML19350B810)
- AECM-81-109, Interim Deficiency Rept Re Installation of Standby Svc Water Pump,Initially Reported on 810212.Pumps in Basins a & B Inspected for Deficiency & Installation Compared W/Design Drawings.Final Rept to Be Submitted by 810901 + (ML19350B811)
- 05000312/LER-1981-015, Forwards LER 81-015/04T-0.Event Analysis Submitted + (ML19350B812)
- 05000312/LER-1981-015-04, /04T-0:on 810214,review of Feb 1981 Effluent Charts Showed Tech Spec for Plant Effluent Ph Was Exceeded. Caused by Effluent Diversion Setpoint Being Slightly out-of-tolerance.Setpoints Lowered + (ML19350B814)
- ML19350B815 + (ML19350B815)
- ML19350B816 + (ML19350B816)
- ML19350B817 + (ML19350B817)
- ML19350B818 + (ML19350B818)
- 05000366/LER-1981-003, Forwards LER 81-003/03L-0 + (ML19350B819)
- ML19350B820 + (ML19350B820)
- 05000366/LER-1981-003-03, /03L-0:on 810223,core Max Fraction of Limiting Power Density Found to Be Greater than Frtp During Startup. Caused by Time Delays for Adjusting Rods,Running Transient Incore Probe Scans & Processing Time for Computer + (ML19350B821)
- 05000315/LER-1981-003, Forwards LER 81-003/03L-0 + (ML19350B822)
- ML19350B823 + (ML19350B823)
- 05000296/LER-1981-012, Forwards LER 81-012/03L-0 + (ML19350B824)
- ML19350B825 + (ML19350B825)
- ML19350B826 + (ML19350B826)
- 05000296/LER-1981-012-03, /03L-0:on 810224,scram Discharge Level Switch (25 Gallon) Found 0.4% Above Setpoint During Performance of SI 4.1.A-8.Caused by Model SL-305-EI-X Level Switch, 3-LS-85-45E,setpoint Drift.Switch Recalibr + (ML19350B827)
- ML19350B828 + (ML19350B828)
- ML19350B829 + (ML19350B829)
- 05000366/LER-1980-151, Forwards Updated LER 80-151/03X-1 + (ML19350B830)
- ML19350B832 + (ML19350B832)
- ML19350B833 + (ML19350B833)
- 05000366/LER-1980-151-03, Primary Feedwater Isolation Valve 2B21-F010B Leakage Rate Found to Exceed Bypass Path Penetration Tech Spec.Caused by Scratches on Seat of Valve Due to Valve Closing on Debris + (ML19350B834)
- ML19350B835 + (ML19350B835)
- 05000366/LER-1981-015, Forwards LER 81-015/03L-0 + (ML19350B836)
- ML19350B837 + (ML19350B837)
- 05000366/LER-1981-015-03, /03L-0:on 810304,intermediate Range Monitor H (2C51-K601H) Would Not Come on Scale for Overlap Check Between Intermediate & Source Range Monitors During Scram Recovery Procedure HNP-2-1010.Caused by Pushed Back Pins + (ML19350B839)
- ML19350B840 + (ML19350B840)
- ML19350B841 + (ML19350B841)
- ML19350B843 + (ML19350B843)
- ML19350B844 + (ML19350B844)
- ML19350B845 + (ML19350B845)