ML19350B837

From kanterella
Jump to navigation Jump to search
Forwards LER 81-015/03L-0
Date released: 12/30/2019 Download: ML19350B837


LER 81-015/03L-0:on 810304,intermediate Range Monitor H (2C51-K601H) Would Not Come on Scale for Overlap Check Between Intermediate & Source Range Monitors During Scram Recovery Procedure HNP-2-1010.Caused by Pushed Back Pins
ML19350B839
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 03/17/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19350B839 (2)
Forwards LER 81-015/03L-0
ML19350B836
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 03/17/1981
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19350B836 (1)