Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000327/LER-1981-017, Forwards LER 81-017/03L-0 + (ML19347D216)
- ML19347D217 + (ML19347D217)
- 05000317/LER-1981-009, Forwards LER 81-009/03L-0 + (ML19347D218)
- ML19347D219 + (ML19347D219)
- 05000327/LER-1981-017-03, /03L-0:on 810212,welder Accidentally Blew Pin Hole in Pipe Sleeve,Releasing Low Level Activity Xe-133.Caused by Thin Wall Pipe & Restricted Access.Pin Hole Repaired + (ML19347D220)
- ML19347D221 + (ML19347D221)
- 05000317/LER-1981-009-03, /03L-0:on 810205,reactor Protector Sys Channel D Trip Units Bypassed.Caused by Increase in Temp Detector Resistance,Probably Due to Increased Connection Resistance in Containment.Input Removed from Channel D + (ML19347D222)
- ML19347D223 + (ML19347D223)
- ML19347D225 + (ML19347D225)
- DD-80-34, Informs That Time for Commission to Act to Review Directors Decision DD-80-34 Has Expired.Decision Became Final Agency Action on 810303 + (ML19347D226)
- ML19347D227 + (ML19347D227)
- ML19347D228 + (ML19347D228)
- ML19347D229 + (ML19347D229)
- ML19347D230 + (ML19347D230)
- ML19347D231 + (ML19347D231)
- ML19347D232 + (ML19347D232)
- ML19347D233 + (ML19347D233)
- ML19347D234 + (ML19347D234)
- 05000267/LER-1981-015, Forwards LER 81-015/03L-0.Detailed Event Analysis Encl + (ML19347D235)
- ML19347D236 + (ML19347D236)
- 05000267/LER-1981-015-03, /03L-0:on 810204-0220,plant Operated in Degraded Mode on Nine Occasions.Causes Include Increased Oxidant Outgassing After Power Increase & Moisture Introduced Into Primary Coolant as Part of Approved Test + (ML19347D237)
- 05000327/LER-1981-018, Forwards LER 81-018/03L-0 + (ML19347D238)
- ML19347D239 + (ML19347D239)
- 05000327/LER-1981-018-03, /03L-0:on 810205,discovered That SI-137.2,RCS Water Inventory,Not Performed within 72-h Per Surveillance Requirements.Caused by Steady State Conditions Not Being Established Long Enough for Performance Before Reactor Trip + (ML19347D240)
- ML19347D241 + (ML19347D241)
- ML19347D242 + (ML19347D242)
- ML19347D243 + (ML19347D243)
- ML19347D244 + (ML19347D244)
- ML19347D245 + (ML19347D245)
- ML19347D246 + (ML19347D246)
- ML19347D247 + (ML19347D247)
- ML19347D248 + (ML19347D248)
- 05000278/LER-1981-008, Forwards LER 81-008/01T-0 + (ML19347D249)
- ML19347D251 + (ML19347D251)
- 05000278/LER-1981-008-01, /01T-0:on 810211,main Isolation Valve on Loop B Mistakenly Isolated Instead of Loop a Valve During Installation of Test Connection to 1-inch Containment Atmospheric Dilution Line.Caused by Wrong Valve Designation + (ML19347D252)
- ML19347D253 + (ML19347D253)
- ML19347D254 + (ML19347D254)
- 05000324/LER-1981-025, Forwards LER 81-025/01T-0 + (ML19347D255)
- ML19347D256 + (ML19347D256)
- ML19347D257 + (ML19347D257)
- 05000325/LER-1981-019, Forwards LER 81-019/03L-0 + (ML19347D258)
- IR 05000274/2019201 + (ML19347D259)
- ML19347D260 + (ML19347D260)
- ML19347D261 + (ML19347D261)
- 05000324/LER-1981-025-01, /01T-0:on 810223,per IE Bulletin 79-07 Analysis, 10 Pipe Supports on Control Rod Driveline Vent Line Piping Found Susceptible to Failure in Seismic Event.Caused by as-built Condition.Beams & Plates Added to Supports + (ML19347D262)
- ML19347D264 + (ML19347D264)
- 05000325/LER-1981-019-03, /03L-0:on 810204,isolation Valves to Primary Containment post-accident Radiation monitor,1-CAC-AI-1262, Found Open W/Monitor Photohelic Unit Removed.Caused by Inadequate Maint Procedures.Supplemental Rept to Be Issued + (ML19347D265)
- ML19347D266 + (ML19347D266)
- ML19347D268 + (ML19347D268)
- ML19347D269 + (ML19347D269)
- ML19347D270 + (ML19347D270)