- ML19344D976 + (ML19344D976)
- 05000366/LER-1980-114-03, /03L-0:on 800726,while Taking Unit to Cold Shutdown,Hpci Sys Failed to Isolate at Greater than or Equal to 100 Psig.Caused by Corrosion of B Isolation Logic Pressure Switch 2E41-N001D.Instrument Replaced + (ML19344D977)
- ML19344D978 + (ML19344D978)
- ML19344D979 + (ML19344D979)
- ML19344D980 + (ML19344D980)
- ML19344D981 + (ML19344D981)
- 05000344/LER-1980-016, Forwards LER 80-016/03L-0 + (ML19344D982)
- ML19344D985 + (ML19344D985)
- 05000344/LER-1980-016-03, /03L-0:on 800719,during Low Power Physics Testing, South Boric Acid Tank Boron Concentration & North Boric Acid Tank Level Exceeded Tech Specs.Caused by Personnel Error + (ML19344D986)
- ML19344D987 + (ML19344D987)
- 05000267/LER-1980-039-03, /03L-0:on 800721,liquid Nitrogen Storage Tank Level Determined Below Tech Specs.Caused by Use of Nitrogen Blanket During Loop Shutdown & Late Delivery of Liquid Nitrogen Shipment.More Liquid Nitrogen Ordered + (ML19344D988)
- ML19344D989 + (ML19344D989)
- 05000293/LER-1980-040, Forwards LER 80-040/03L-0 + (ML19344D990)
- ML19344D991 + (ML19344D991)
- ML19344D992 + (ML19344D992)
- ML19344D993 + (ML19344D993)
- ML19344D994 + (ML19344D994)
- 05000293/LER-1980-040-03, /03L-0:on 800724,standby Gas Treatment Sys Found Inoperable.Caused by Breaker Being Unintentionally Moved to Open Position,Possibly During Daily Operator Tour.Breaker Returned to Normal.Operational Check Satisfactory + (ML19344D995)
- 05000267/LER-1980-042-03, /03L-0:on 800725,plant Was Operated at Approx 47% Thermal Power & 131 Mwe W/Two Inoperable Reserve Shutdown Units in 30 Hopper Subsystem.Caused by Isolation of Bottle for Repair of Leakage at Brass Fitting for Region 15 Hook + (ML19344D996)
- 05000312/LER-1980-038, Forwards LER 80-038/041-0 + (ML19344D997)
- ML19344D999 + (ML19344D999)
- ML19344E000 + (ML19344E000)
- ML19344E001 + (ML19344E001)
- 05000312/LER-1980-038-41, /041-0:on 800729,review of Plant Effluent Data for Jul 1980 Indicated That on 800629 & 30,sample Indicated 0.25 & 0.3 Mg/Liter Chlorine.Second Followup Sample Not Obtained.Caused by Personnel Error.Personnel Reinstructed + (ML19344E002)
- 05000338/LER-1980-063, Forwards LER 80-063/01T-0 + (ML19344E003)
- ML19344E004 + (ML19344E004)
- 05000312/LER-1980-036, Forwards LER 80-036/041-0 + (ML19344E005)
- 05000312/LER-1980-036-41, /041-0:on 800710,review of Jul 1980 Effluent Monitoring Charts Indicated Plant Liquid Effluent Ph in Excess of 8.5 Tech Spec Limit.Cause Unknown.Automatic Diversion Setpoint Lowered to Minimize Recurrence + (ML19344E007)
- ML19344E009 + (ML19344E009)
- 05000338/LER-1980-063-01, /01T-0:on 800808,w/unit at 100% Power,Feedwater Flow Signal to Reactor Trip Sys Determined to Be in Error by Approx 4%.Caused by Venturi Fouling in Lines.Fouling Will Be Monitored by Comparing Feed Flow to Steam Flow + (ML19344E010)
- ML19344E011 + (ML19344E011)
- 05000321/LER-1980-089, Forwards LER 80-089/03L-0 + (ML19344E012)
- ML19344E013 + (ML19344E013)
- 05000317/LER-1980-036, Forwards LER 80-036/03L-0 + (ML19344E014)
- ML19344E015 + (ML19344E015)
- 05000366/LER-1980-121-01, /01T-0:on 800813,w/unit at 2412 MW While Performing HNP-2-3102,pressure Switches Actuated Out of Tolerance.Caused by Setpoint Drift.Switches Recalibr. HNP-2-3102 Performed Satisfactorily + (ML19344E016)
- 05000321/LER-1980-089-03, /03L-0:on 800726,during Normal Operation,Drywell & Torus Temp Recorder lT47-R611 Found Inoperative.Caused by Stripped Gear in Print Drive Mechanism.Gear Replaced.Design Change Initiated to Replace Recorder + (ML19344E017)
- ML19344E018 + (ML19344E018)
- ML19344E019 + (ML19344E019)
- 05000302/LER-1980-030, Forwards LER 80-030/03L-0 + (ML19344E020)
- ML19344E021 + (ML19344E021)
- ML19344E022 + (ML19344E022)
- 05000298/LER-1980-026, Forwards LER 80-026/03L-0 + (ML19344E024)
- ML19344E025 + (ML19344E025)
- ML19344E026 + (ML19344E026)
- 05000302/LER-1980-030-03, /03L-0:on 800731,during Monthly Diesel Generator Surveillance,Emergency Diesel Generator B Tripped as Result of Separation of Turbocharger Discharge Ductwork Due to Sheared Bolts on Mounting Bracket.Caused by Vibration + (ML19344E027)
- 05000321/LER-1980-088, Forwards LER 80-088/03L-0 + (ML19344E028)
- ML19344E030 + (ML19344E030)
- 05000298/LER-1980-026-03, /03L-0:on 800701,during Routine Measurement of Identified Reactor Leakage,Drywell Equipment Drain Sump Flow Instrument Found Inoperable.Caused by Broken Slide Wire in Recorder & Blown Fuse in Power Supply.Fuse & Wire Replace + (ML19344E031)
- ML19344E032 + (ML19344E032)