- ML19344D281 + (ML19344D281)
- 05000312/LER-1980-009-03, /03L-0:on 800207,during Function Tests of Relays in 4,160-volt Feeder Breakers,Contacts Sfax (Sfbx) Found Not Wired.Caused by Discrepancy Between Design & Internal Switchgear Wiring Diagrams.No Changes Necessary + (ML19344D282)
- ML19344D284 + (ML19344D284)
- 05000346/LER-1979-046, Forwards Revised LER 79-046/03L-1 + (ML19344D286)
- ML19344D287 + (ML19344D287)
- 05000334/LER-1980-007-01, Er 80-007/01T-0:on 800121,during Reload After Defueling, Main Filter Banks Found Not in Svc.Caused by Procedural Inadequacy Because None of Refueling Checklists Indicated Tech Spec Change That Required Flow + (ML19344D288)
- 05000346/LER-1979-046-03, During Surveillance Testing,Diesel Generator 1-1 Began Making Loud Noises & Was Declared Inoperable.Caused by Bearing Failure in Turbocharger.Turbocharger Replaced + (ML19344D289)
- 05000333/LER-1980-021, Forwards LER 80-021/03L-0 + (ML19344D291)
- ML19344D293 + (ML19344D293)
- 05000333/LER-1980-021-03, /03L-0:on 800207,during Normal Shutdown Operations Intermediate Range Monitor B Was Made Inoperable to Repair Signal Cable Connector.Reactor Protections Sys B Placed in Tripped Condition.Caused by Normal Wear + (ML19344D295)
- 05000334/LER-1980-010-03, /03L-0:on 800131,refueling Team Was Given Go Ahead for Core Alterations.Fifteen Minutes Later,Inservice Boric Acid Transfer Pump CH-P-2B Tripped on Thermal Overload. Probably Caused by Faulty Blender Controls Shifting Speed + (ML19344D296)
- ML19344D297 + (ML19344D297)
- 05000333/LER-1980-022, Forwards LER 80-022/03L-0 + (ML19344D298)
- ML19344D300 + (ML19344D300)
- 05000333/LER-1980-022-03, /03L-0:on 800208,during Normal Startup Operations, Drywell Atmosphere Monitor a Was Made Inoperable While B Was Out of Svc Resulting in Operation in Degraded Mode.Caused by Need to Investigate Noise from Sample Pump + (ML19344D301)
- 05000334/LER-1980-011-03, /03L-0:on 800226,during Boron Injection Flow Path Verification,Operator Stroked MOV-SI-869A Connecting Charge Sys Fill Header to RCS Hot Leg Piping.Valve Opened & Linestarter Tripped.Caused by Burnt Motor in MOV-SI-869A + (ML19344D302)
- ML19344D303 + (ML19344D303)
- ML19344D305 + (ML19344D305)
- ML19344D306 + (ML19344D306)
- ML19344D307 + (ML19344D307)
- ML19344D308 + (ML19344D308)
- ML19344D310 + (ML19344D310)
- ML19344D311 + (ML19344D311)
- ML19344D312 + (ML19344D312)
- ML19344D313 + (ML19344D313)
- ML19344D314 + (ML19344D314)
- ML19344D315 + (ML19344D315)
- 05000302/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19344D316)
- ML19344D317 + (ML19344D317)
- ML19344D318 + (ML19344D318)
- 05000302/LER-1980-008-03, /03L-0:on 800206,during ECCS Pump Operability Demonstration Surveillance SP-340,decay Heat Pump a Discharge Throttle Valve Would Not Control Flow Automatic Phase.Caused by Loose Wires on auto-manual Selector Switch + (ML19344D319)
- 05000324/LER-1980-007, Forwards LER 80-007/03L-0 + (ML19344D320)
- ML19344D321 + (ML19344D321)
- 05000321/LER-1980-019, Forwards LER 80-019/03L-0 + (ML19344D322)
- ML19344D323 + (ML19344D323)
- 05000324/LER-1980-007-03, /03L-0:on 800204,when Plant Batteries Were Placed in Equalize,Steam Leak Detection a Logic Topaz Inverter, Model 125-GW 12560,tripped.Caused by Improper Setting on Inverter High Voltage Trip.Inverter Trips Recalibr + (ML19344D324)
- 05000321/LER-1980-019-03, /03L-0:on 800213,while Performing Reactor Core Isolation Cooling Turbine Exhaust Diaphragm Functional Test & Calibr,Pressure Switches 1E51-N012B & 1E51-N012C Found Outside Tech Spec Limits.Caused by Setpoint Drift + (ML19344D325)
- 05000346/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19344D326)
- ML19344D327 + (ML19344D327)
- 05000346/LER-1980-013-03, /03L-0:on 800208,w/reactor Startup in Progress, Personnel Noted Control Rod 5-11 Absolute Position Indication Was Not Responding.Caused by Blown Fuse F14 in Position Ref Panel + (ML19344D328)
- ML19344D329 + (ML19344D329)
- ML19344D330 + (ML19344D330)
- ML19344D331 + (ML19344D331)
- ML19344D332 + (ML19344D332)
- ML19344D333 + (ML19344D333)
- ML19344D334 + (ML19344D334)
- ML19344D335 + (ML19344D335)
- ML19344D336 + (ML19344D336)
- ML19344D337 + (ML19344D337)
- ML19344D338 + (ML19344D338)
- ML19344D339 + (ML19344D339)