- 05000295/LER-1980-042, Forwards LER 80-042/03L-0 + (ML19340B233)
- 05000338/LER-1980-084, Forwards LER 80-084/01T-0 + (ML19340B235)
- ML19340B236 + (ML19340B236)
- 05000295/LER-1980-042-03, /03L-0:on 800912,area Monitor for Auxiliary Bldg Heating,Ventilation & Air Conditioning Filter Area Found Reading Erratically & Produced Periodic Alarms.Cause Not Determined.Monitor Functionally Tested & Returned to Svc + (ML19340B238)
- 05000327/LER-1980-113, Forwards LER 80-113/01T-0 + (ML19340B239)
- ML19340B240 + (ML19340B240)
- 05000306/LER-1980-027, Forwards LER 80-027/03L-0 + (ML19340B241)
- ML19340B242 + (ML19340B242)
- ML19340B244 + (ML19340B244)
- 05000338/LER-1980-084-01, /01T-0:on 801002,Westinghouse Notified Util That High Steam Line Flow Setpoints Specified in PLS Document Are Less Conservative than Tech Specs Require.Caused by Calculation Assumptions Not Reflecting Installation + (ML19340B245)
- 05000259/LER-1980-073-01, /01T-0:on 800928,during Steady State Operation, River Water Temp Peaked at 5.1 F Temp Difference.Situation Recurred Next Day.Caused by Incorrect River Temp Rise Predictions.Events Are Random Occurrences + (ML19340B246)
- ML19340B248 + (ML19340B248)
- 05000327/LER-1980-113-01, /01T-0:on 800926,while Exiting Containment Through Upper Containment Airlock,Employee Allowed Inner Door to Slam & Bounce Back.Latch Then Closed Blocking Door Ajar. Caused by Improper Adjustments on Door Operating Mechanism + (ML19340B249)
- 05000344/LER-1980-020, Forwards LER 80-020/01T-0 + (ML19340B251)
- 05000306/LER-1980-027-03, /03L-0:on 800919,steam Flow Transmitter 2FT-474 Found Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter. Transmitter Recalibr.Transmitters Scheduled to Be Replaced + (ML19340B255)
- ML19340B257 + (ML19340B257)
- 05000344/LER-1980-020-01, /01T-0:on 801003,following Reactor Trip,Both Trains of Auxiliary Feedwater Pumps Failed to Respond to Automatic Start Signal.Pumps Were Manually Started.Caused by Incorrectly Wired Slave Relay + (ML19340B258)
- ML19340B261 + (ML19340B261)
- ML19340B263 + (ML19340B263)
- 05000293/LER-1980-068, Forwards LER 80-068/03L-0 + (ML19340B264)
- ML19340B265 + (ML19340B265)
- ML19340B266 + (ML19340B266)
- 05000293/LER-1980-067, Forwards LER 80-067/01T-0 + (ML19340B267)
- ML19340B268 + (ML19340B268)
- ML19340B270 + (ML19340B270)
- ML19340B271 + (ML19340B271)
- ML19340B273 + (ML19340B273)
- 05000293/LER-1980-068-03, /03L-0:on 800924,logging of Reactor Protection Sys Motor Generator Set Current & Voltage Was Inadvertently Terminated During Last Refueling Outage.Caused by Inadequate Station Procedures.Procedures 2.1.15 Revised + (ML19340B274)
- 05000293/LER-1980-067-01, /01T-0:on 801002,analytical Reanalysis of B RHR Sys Indicated That as-built Configurations of Sys Would Not Remain Functional During Sse.Caused by Design Error.Seismic Anchor Modified to Meet Criteria + (ML19340B275)
- 05000277/LER-1980-020, Forwards LER 80-020/01T-0 + (ML19340B276)
- ML19340B277 + (ML19340B277)
- 05000348/LER-1980-055-03, /03L-0:on 800910,during Surveillance testing,1A Reactor Coolant Pump Bus Train B Undervoltage Relay Was Declared Inoperable Due to Incorrect Trip Value.Caused by as-left Condition Following Previous Surveillance + (ML19340B278)
- ML19340B279 + (ML19340B279)
- ML19340B280 + (ML19340B280)
- 05000348/LER-1980-056-03, /03L-0:on 800911,svc Water Bldg a Train Battery Sys Was Declared Inoperable Due to Low Battery Cell Specific Gravity.Caused by Close Terminal Post Proximity & Poor Terminal Post Seal Design Which Caused Acid Leakage + (ML19340B281)
- 05000277/LER-1980-020-01, /01T-0:on 800926,breaker Which Supplies Power to B Standby Liquid Control Sys Pump & B Squib Valve Found Open. Caused by Accidental Tripping of Pump Breaker.Breaker Switches of All Sblc Pumps Locked + (ML19340B282)
- ML19340B283 + (ML19340B283)
- ML19340B285 + (ML19340B285)
- ML19340B288 + (ML19340B288)
- ML19340B290 + (ML19340B290)
- ML19340B292 + (ML19340B292)
- 05000254/LER-1980-024, Forwards LER 80-024/03L-0 + (ML19340B293)
- ML19340B294 + (ML19340B294)
- ML19340B295 + (ML19340B295)
- ML19340B296 + (ML19340B296)
- 05000254/LER-1980-024-03, /03L-0:on 800914,during Core Unload,Fuel Bundle Was Removed While Source Range Monitor Was Reading Less than Min Required by Tech Specs.Caused by Misunderstanding of Recent Tech Spec Change + (ML19340B298)
- ML19340B299 + (ML19340B299)
- ML19340B300 + (ML19340B300)
- ML19340B301 + (ML19340B301)
- ML19340B303 + (ML19340B303)
- ML19340B304 + (ML19340B304)