LER 80-049/03L-0:on 800904,PCRV Rupture disc,M-11702, Setpoint Set at 826 Psig Rather than 812 Psig.Caused by Drift in Belleville Washer Operating Point.Threaded Ring Adjusted Until Rupture Disc Actuated at Correct Setpoint