- 05000317/LER-1980-045-03, /03L-0:on 800820,computer Indication Failed Except for Control Element Assembly Position Indication.Caused by Loose Wire Connectors at Several Edge Connector Pins for Analog Bus Segmentation Cards.Connectors Soldered in Plac + (ML19338D724)
- ML19338D725 + (ML19338D725)
- ML19338D726 + (ML19338D726)
- ML19338D727 + (ML19338D727)
- ML19338D728 + (ML19338D728)
- 05000304/LER-1980-003-03, /03L-0:on 800816,MSIV Low Pressure Annunciator Alarmed & Oil Pump Would Not Run.Caused by Failed Control Power Transformer.Transformer Replaced + (ML19338D729)
- 05000368/LER-1980-068, Forwards LER 80-068/03L-0 + (ML19338D730)
- ML19338D731 + (ML19338D731)
- 05000259/LER-1980-063, Forwards LER 80-063/03L-0 + (ML19338D732)
- ML19338D733 + (ML19338D733)
- ML19338D735 + (ML19338D735)
- 05000325/LER-1980-067, Forwards LER 80-067/03L-0 + (ML19338D736)
- ML19338D737 + (ML19338D737)
- 05000348/LER-1980-049, Forwards LER 80-049/03L-0 + (ML19338D738)
- ML19338D739 + (ML19338D739)
- ML19338D740 + (ML19338D740)
- 05000368/LER-1980-068-03, /03L-0:on 800823,during Mode 1,leak Was Discovered on B Charging pump,2P36B,discharge Header at Discharge Relief Valve Pipe.Apparent Cause Is Vibration Induced from Positive Displacement Pumps.Mods Made to All Three Pumps + (ML19338D741)
- 05000259/LER-1980-063-03, /03L-0:on 800820,during Normal operation,CAM-1-RH- 90-251 for Turbine Bldg Roof Vent Removed from Svc for Period Exceeding 1-h Due to Failure of Schwitzer Series 325 Model 145473 Vacuum Pump.Pump Replaced + (ML19338D742)
- 05000259/LER-1980-064, Forwards LER 80-064/03L-0 + (ML19338D744)
- ML19338D745 + (ML19338D745)
- 05000325/LER-1980-067-03, /03L-0:on 800822,while Withdrawing Control Rods During Startup,Erroneous Rod Blocks Were Received from Rod Worth Minimizer.Also,Plant Process Computer Printed Notch Errors While None Existed.Cause Not Determined + (ML19338D746)
- 05000325/LER-1980-063, Forwards LER 80-063/03L-0 + (ML19338D747)
- ML19338D749 + (ML19338D749)
- 05000324/LER-1980-050, Forwards LER 80-050/03L-0 + (ML19338D750)
- ML19338D751 + (ML19338D751)
- ML19338D752 + (ML19338D752)
- 05000348/LER-1980-048, Forwards LER 80-048/03L-0 + (ML19338D753)
- ML19338D754 + (ML19338D754)
- ML19338D755 + (ML19338D755)
- ML19338D757 + (ML19338D757)
- 05000324/LER-1980-050-03, /03L-0:on 800821,switch 2 of 2-B21-PIS-N021B, Barton Model 288 Found Out of Calibr.Probably Caused by Accidental Bumping by Personnel During Refueling Outage. Switch & Instrument Recalibr & Returned to Svc + (ML19338D758)
- 05000259/LER-1980-064-03, /03L-0:on 800820,during Normal operation,CAM-1- RM-90-249 for Turbine Bldg Roof Vents Removed from Svc for Period Exceeding 1-h.Caused by Personnel Error.Personnel Cautioned to Observe Time Limit + (ML19338D759)
- 05000348/LER-1980-048-03, /03L-0:on 800817,containment Atmosphere Gaseous & Particulate Radioactivity Monitoring Sys Were Declared Inoperable Due to Pump Failure & Pump Trip on Low Flow. Caused by Pump Burnout & Sys Flow Maladjustment + (ML19338D760)
- ML19338D762 + (ML19338D762)
- 05000293/LER-1980-057, Forwards LER 80-057/03L-0 + (ML19338D764)
- ML19338D765 + (ML19338D765)
- ML19338D766 + (ML19338D766)
- 05000325/LER-1980-066, Forwards LER 80-066/03L-0 + (ML19338D770)
- ML19338D771 + (ML19338D771)
- 05000348/LER-1980-049-03, /03L-0:on 800820,reactor Trip Instrumentation Channel Associated W/Rcs Loop Flow Transmitter 434 Inoperable Due to Loss of Flow Indication.Caused by Defective Transistors on Card C1-242 + (ML19338D772)
- 05000282/LER-1980-025, Forwards LER 80-025/01T-0 + (ML19338D773)
- ML19338D774 + (ML19338D774)
- 05000293/LER-1980-057-03, /03L-0:on 800821,fluid Drive Pump Tripped & Backup & Emergency Oil Pump Did Not Start.Caused by Coil Burnout on 125 Volt DC Agastat Relay Model 2412.Relay Replaced & Design Change Initiated + (ML19338D775)
- 05000325/LER-1980-066-03, /03L-0:on 800824,during Normal Surveillance, Containment Atmospheric Monitor Oxygen Analyzer, 1-CAC-ATH-1259-2,was Observed Indicating Upscale.Caused by Loss of Sample Flow Due to Condensate in Analyzer Air Dryer + (ML19338D776)
- 05000282/LER-1980-025-01, /01T-0:on 800904,during Refueling Shutdown, Ultrasonic Exam of Steam Generator Support Bolts Revealed Crack Indications.Unit 2 Also Inspected.Caused by Environ Assisted Cracking.All Unit 1 Bolts Will Be Replaced + (ML19338D778)