p

~:q.

',y

\\.

s I:

Omaha Public' Power District

+

1623 HARNEY-a.. O M A N A. NEERASKA 68102

  • -TELEPHONE 536 4000 AREA CODE 402 -

September 18,'1980 Mr. M. R. Beebe U.

S.- Nuclear Regulatory Jamission Office of Management and Program Analysis Licensee Operations Evaluation Branch Washington, D. C.

20555

Reference:

Docket No. 50-285

Dear Mr. Beebe:

Omaha Public Power District (0 PPD) received the Comission's letter dated' August 25, 1980, asking for verification of an enclosed draft sumary of Fort Calhoun's radioactive effluent releases. The District has completed a review of the enclosure to your letter.. Four (4) correctio'ns are required. On page 5 of the enclosure for liquid effluents, the Strontium 89 and 90 values-for ::econd quarter continuous and batch modes should be revised accordingly:

Nuclides Mode-2nd Quarter Present Value Corrected Value Sr-89 Continuous 0.00E-00

<7.17E-05 Sr Batch 0.00E-00 2.71E-04 Sr-90 Continuous 0.00E-00

<3.59E-05 Sr-90 Batch 0.00E-00 4.07E-05 i

All other information has been verified to be correct.

Sincerely,

./

f., /,[

q

' z; L ' W'. C/ Jones

,,~

Division _ Manager Production Operations

.WCJ/KJM/TLP:jm cc: LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N. W.

Washington, D. C.

.20036 007 s

iO

s o gg ggg.

l2/

lL-