ML19338D749

From kanterella
Jump to navigation Jump to search
Forwards LER 80-063/03L-0
Date released: 12/18/2019 Download: ML19338D749


LER 80-063/03L-0:on 800826,during Testing of Reactor Flow Bias,Three Average Power Range Monitors Were Actuating Out of Spec.Caused by Instrument Drift.Monitors Recalibr & Returned to Svc
ML19338D784
Person / Time
Site: Brunswick 
Issue date: 09/16/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19338D784 (1)
Forwards LER 80-063/03L-0
ML19338D747
Person / Time
Site: Brunswick 
Issue date: 09/16/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19338D747 (1)