Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000456/LER-1989-002-01, :on 890416,main Steamline Low Pressure Reactor Trip,Safety Injection & Main Steamline Isolation Occurred. Caused by Mgt & Procedural Deficiencies.Formal Policy on Use of Extra Operator During Startup Developed + (ML19332E641)
- ML19332E642 + (ML19332E642)
- ML19332E644 + (ML19332E644)
- ML19332E646 + (ML19332E646)
- IR 05000424/1989032 + (ML19332E647)
- ML19332E648 + (ML19332E648)
- ML19332E651 + (ML19332E651)
- ML19332E656 + (ML19332E656)
- ML19332E657 + (ML19332E657)
- 05000374/LER-1989-015-05, :on 891030,shift Control Room Engineer Noted That Quarterly Standby Liquid Control Operating Surveillance LOS-SC-Q1 Was Past Critical Date.Caused by Clerical Data Entry Error.Missed Surveillance Performed + (ML19332E658)
- ML19332E659 + (ML19332E659)
- 05000295/LER-1989-021-02, :on 891102,control Switch for Svc Water Pump 1C Taken from Pull to Lock Position to After Trip Position & Pump auto-started.Caused by Personnel Error Due to Poor Communication.Relay Properly Unlatched + (ML19332E660)
- ML19332E667 + (ML19332E667)
- ML19332E668 + (ML19332E668)
- ML19332E669 + (ML19332E669)
- ML19332E670 + (ML19332E670)
- ML19332E674 + (ML19332E674)
- ML19332E676 + (ML19332E676)
- IR 05000160/1989002 + (ML19332E677)
- ML19332E678 + (ML19332E678)
- ML19332E680 + (ML19332E680)
- ML19332E681 + (ML19332E681)
- ML19332E683 + (ML19332E683)
- ML19332E684 + (ML19332E684)
- ML19332E688 + (ML19332E688)
- IR 05000395/1989021 + (ML19332E691)
- PY-CEI-NRR-1106, Responds to Violations Noted in Insp Rept 50-440/89-12 on 890627 & 1023.Corrective Actions:Flange Leakage of Relief Valve Repaired During First Refueling Outage & Design Mods to Enhance Testability of Gasketed Flanges Being Developed + (ML19332E692)
- ML19332E694 + (ML19332E694)
- ML19332E701 + (ML19332E701)
- IR 05000302/1989026 + (ML19332E703)
- ML19332E704 + (ML19332E704)
- IR 05000498/1989043 + (ML19332E706)
- 05000277/LER-1989-028-01, :on 891108,review Determined That Standby Gas Treatment Sys Heater Control Relays Unqualified for post-LOCA Radiation Environ & Declared Inoperable.Cause Undetermined.Radiation Shielding Installed + (ML19332E708)
- ML19332E709 + (ML19332E709)
- ML19332E710 + (ML19332E710)
- ML19332E713 + (ML19332E713)
- ML19332E714 + (ML19332E714)
- 05000295/LER-1989-023-02, :on 891108,discovered That Door from Control Room to Process Computer Room Blocked Open W/No Firewatch. Caused by Personnel Error of Shift Engineer & Security Dept. Firewatch Initiated + (ML19332E716)
- AECM-89-0219, Revised marked-up Tech Specs Re Establishment of New Company Called Eoi,As sys-wide Nuclear Operations Company + (ML19332E717)
- ML19332E718 + (ML19332E718)
- IR 05000382/1989030 + (ML19332E719)
- 05000413/LER-1989-023, :on 890915,Tech Spec 3.0.3 Entered as Result of Both Trains of Control Room Area Ventilation Sys Being Inoperable.Caused by Equipment Malfunctions.Control Room & Area Pressurization Flow Rates Revised + (ML19332E720)
- IR 05000382/1989026 + (ML19332E721)
- 05000266/LER-1989-009, :on 891107,D05 & D06 Station Batteries Declared Inoperable.Caused by Original Design Deficiency.Mod Completed to Restore Battery D05 to Operable Status by Replacing Eight nonsafety-related Breakers + (ML19332E722)
- ML19332E731 + (ML19332E731)
- ML19332E734 + (ML19332E734)
- ML19332E736 + (ML19332E736)
- ML19332E738 + (ML19332E738)
- 05000285/LER-1988-037, :on 881214,one of Two Supply Headers Supplying Fire Suppression Headers in Auxiliary Bldg Isolated.Caused by Lack of Procedural Guidance & Inadequate Procedural Controls.Standing Order G-58 Will Be Revised + (ML19332E743)
- ML19332E744 + (ML19332E744)
- ML19332E746 + (ML19332E746)