Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000293/LER-1980-050-01, /01T-0:on 800911,during Mgt Review,Concluded That Operation & Maint on Containment Cooling Sys Had Been Conducted in Less Conservative Manner than Prescribed in Tech Specs.Caused by Sparse & Ambiguous Tech Specs + (ML19332B307)
- 05000312/LER-1980-040-03, /03L-0:on 800812,reactor Protection Sys Channel D Trip Signal Was Received.Caused by Amplifier Failure in Electronic Portion of Transmitter.Transmitter Replaced, Calibr,Leak Tested & Returned to Svc + (ML19332B308)
- ML19332B309 + (ML19332B309)
- 05000293/LER-1980-032, Forwards LER 80-032/01T-0 + (ML19332B311)
- ML19332B312 + (ML19332B312)
- ML19332B315 + (ML19332B315)
- 05000293/LER-1980-032-01, /01T:on 800724,GE SIL 299 Review Revealed Higher Drywell Ambient Temp than Used for Original Safeguard Yarway Calibrs.Caused by High Temp Due to Inadequate Drywell Cooling.Recalibr & Survey of Drywell Ventilation Conducted + (ML19332B317)
- ML19332B318 + (ML19332B318)
- ML19332B319 + (ML19332B319)
- ML19332B320 + (ML19332B320)
- 05000309/LER-1980-018, Forwards LER 80-018/03L-0 + (ML19332B321)
- ML19332B324 + (ML19332B324)
- 05000309/LER-1980-018-03, /03L-0:on 800826,during Steady State Power Operation,W/Diesel generator,DG-1B,being Operated in Surveillance mode,DG-1B Auto Tripped on Overspeed.Caused by Loose Overspeed Trip Switch Actuating Arm.Arm Tightened + (ML19332B325)
- ML19332B326 + (ML19332B326)
- ML19332B330 + (ML19332B330)
- ML19332B331 + (ML19332B331)
- ML19332B332 + (ML19332B332)
- ML19332B333 + (ML19332B333)
- ML19332B334 + (ML19332B334)
- ML19332B335 + (ML19332B335)
- ML19332B336 + (ML19332B336)
- ML19332B337 + (ML19332B337)
- ML19332B338 + (ML19332B338)
- ML19332B340 + (ML19332B340)
- ML19332B342 + (ML19332B342)
- ML19332B343 + (ML19332B343)
- ML19332B344 + (ML19332B344)
- ML19332B345 + (ML19332B345)
- ML19332B347 + (ML19332B347)
- ML19332B348 + (ML19332B348)
- ML19332B349 + (ML19332B349)
- ML19332B350 + (ML19332B350)
- ML19332B351 + (ML19332B351)
- ML19332B352 + (ML19332B352)
- ML19332B353 + (ML19332B353)
- ML19332B354 + (ML19332B354)
- ML19332B356 + (ML19332B356)
- ML19332B358 + (ML19332B358)
- ML19332B359 + (ML19332B359)
- ML19332B360 + (ML19332B360)
- ML19332B363 + (ML19332B363)
- ML19332B364 + (ML19332B364)
- ML19332B367 + (ML19332B367)
- 05000263/LER-1980-027, Forwards LER 80-027/03L-0 + (ML19332B368)
- ML19332B369 + (ML19332B369)
- 05000409/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19332B370)
- ML19332B373 + (ML19332B373)
- 05000409/LER-1980-008-03, /03L-0: 800819,1B High Pressure Svc Water Diesel Did Not Start on Manual Activation.Diesel Did Start Locally from Battery Banks.Caused by Bad Cell in One B Bank Battery. Battery Replaced + (ML19332B374)
- 05000309/LER-1980-017, Forwards LER 80-017/03L-0 + (ML19332B375)
- 05000324/LER-1980-066-01, /01T-0:on 800907,reactor Core Isolation Cooling Turbine Tripped on High Turbine Exhaust Pressure.Caused by Improper Valve Positioning Apparently Due to Personnel Error + (ML19332B377)
- ML19332B378 + (ML19332B378)