- ML19330C378 + (ML19330C378)
- 05000321/LER-1980-087, Forwards LER 80-087/01T-0 + (ML19330C379)
- ML19330C380 + (ML19330C380)
- ML19330C381 + (ML19330C381)
- 05000321/LER-1980-086, Forwards LER 80-086/01T-0 + (ML19330C382)
- ML19330C383 + (ML19330C383)
- 05000313/LER-1980-023-03, /03L-0:on 800709,during Test of Steam Driven Emergency Feed Pump P-7A,main Steam Supply Valve CV-2667 to P-7A Did Not Fully Open on Demand.Caused by Valve Operator Torquing Out Early.Torque Switch Given Small Adjustment + (ML19330C384)
- 05000313/LER-1980-024, Forwards LER 80-024/03L-0 + (ML19330C385)
- ML19330C386 + (ML19330C386)
- 05000321/LER-1980-086-01, /01T-0:on 800724,w/Unit 1 in Cold Shutdown,Support P52-F512-H704 Determined Missing on Instrument Air Sys. Caused by Inadequate Small Bore Piping Design.New Hanger Design Supplied & Support Installed + (ML19330C387)
- ML19330C388 + (ML19330C388)
- ML19330C389 + (ML19330C389)
- ML19330C390 + (ML19330C390)
- 05000313/LER-1980-024-03, /03L-0:on 800706,during Start of Emergency Feedwater Pump Turbine Drive Surveillance,Pump Tripped on Overspeed.Caused by Five of Eight Studs Holding Governor Steam Valve to Turbine Being Broken.All Bolts Replaced + (ML19330C391)
- 05000321/LER-1980-087-01, /01T-0:on 800724 W/Unit Shut Down During IE Bulletin 79-14 Review,Ae Found Anchor Inadequately Supported.Caused by Inadequate Design of Original Support. Design Modified & Anchor Replaced + (ML19330C392)
- ML19330C393 + (ML19330C393)
- 05000155/LER-1980-018, Forwards LER 80-018/03L-0 + (ML19330C394)
- ML19330C398 + (ML19330C398)
- 05000155/LER-1980-018-03, /03L-0:on 800710,during Gravity Check,Cells 35 & 54 of Battery Power Supply for Reactor Depressurizing Sys Channel C Found Below Tech Spec Values.Cause Unknown.Cells Failed to Respond to Charge & Channel Removed from Svc + (ML19330C399)
- ML19330C403 + (ML19330C403)
- 05000318/LER-1979-075, Has Been Cancelled + (ML19330C405)
- 05000317/LER-1979-078-01, Has Been Cancelled + (ML19330C406)
- ML19330C407 + (ML19330C407)
- 05000029/LER-1980-005, Has Been Cancelled + (ML19330C408)
- ML19330C409 + (ML19330C409)
- IR 05000178/2038001 + (ML19330C410)
- ML19330C412 + (ML19330C412)
- ML19330C413 + (ML19330C413)
- ML19330C415 + (ML19330C415)
- ML19330C416 + (ML19330C416)
- ML19330C418 + (ML19330C418)
- ML19330C419 + (ML19330C419)
- ML19330C420 + (ML19330C420)
- ML19330C421 + (ML19330C421)
- ML19330C422 + (ML19330C422)
- ML19330C423 + (ML19330C423)
- ML19330C425 + (ML19330C425)
- 05000339/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19330C427)
- ML19330C428 + (ML19330C428)
- ML19330C429 + (ML19330C429)
- ML19330C430 + (ML19330C430)
- 05000339/LER-1980-033-03, /03L-0:on 800710,during Mode 3,greater than 12 Step Disagreement Occurred Between Rod Position Indicator N-7 & Group Demand Indication.Caused by Voltage Drift in Signal Conditioning Card.Indication Realigned + (ML19330C431)
- ML19330C432 + (ML19330C432)
- 05000339/LER-1980-032, Forwards LER 80-032/03L-0 + (ML19330C433)
- ML19330C434 + (ML19330C434)
- ML19330C436 + (ML19330C436)
- 05000338/LER-1980-062, Forwards LER 80-062/03L-0 + (ML19330C437)
- ML19330C438 + (ML19330C438)
- 05000339/LER-1980-035, Forwards LER 80-035/03L-0 + (ML19330C439)
- ML19330C441 + (ML19330C441)
- 05000338/LER-1980-062-03, /03L-0:on 800708,during Leak Test on Equipment Hatch Escape Lock,Air Leaked Past Inner Seals.Caused by Defective Gasket.Strongback Installed & Gasket Replaced + (ML19330C442)