- ML19316A407 + (ML19316A407)
- ML19316A408 + (ML19316A408)
- 05000269/LER-1978-006-03, /03L-0:on 780305,Keowee Hydro Unit 2 Failed to Start.Caused by Inoperable Field Flashing Breaker.Breaker Failed on Three Previous Occasions (ROs 269/77-29,269/78- 01 & 269/78-03).Cause Unknown & Under Investigation + (ML19316A409)
- ML19316A410 + (ML19316A410)
- ML19316A411 + (ML19316A411)
- ML19316A412 + (ML19316A412)
- ML19316A413 + (ML19316A413)
- ML19316A414 + (ML19316A414)
- ML19316A415 + (ML19316A415)
- ML19316A416 + (ML19316A416)
- ML19316A417 + (ML19316A417)
- ML19316A418 + (ML19316A418)
- ML19316A419 + (ML19316A419)
- 05000269/LER-1978-029-03, /03L-0:on 780105,Unit 2 Failed to Start on Initiation.Caused by Failure of Breaker DB-26 to Close. Breaker Verified Operable by Subsequent Operation.Insp & Servicing Resulted in No Further Corrective Action + (ML19316A420)
- ML19316A421 + (ML19316A421)
- ML19316A422 + (ML19316A422)
- ML19316A423 + (ML19316A423)
- ML19316A424 + (ML19316A424)
- ML19316A425 + (ML19316A425)
- ML19316A426 + (ML19316A426)
- ML19316A427 + (ML19316A427)
- ML19316A428 + (ML19316A428)
- ML19316A429 + (ML19316A429)
- ML19316A430 + (ML19316A430)
- ML19316A431 + (ML19316A431)
- ML19316A433 + (ML19316A433)
- ML19316A435 + (ML19316A435)
- ML19316A436 + (ML19316A436)
- ML19316A437 + (ML19316A437)
- ML19316A438 + (ML19316A438)
- ML19316A440 + (ML19316A440)
- 05000269/LER-1978-001-03, /03L-01:on 780103,valve 3LP-14 Failed to Cycle Manually.Caused by Unaligned Engaging Collar Slipping While Trying to Cycle.Collar Realigned,Setscrew & Handwheel Tightened + (ML19316A441)
- 05000269/LER-1977-017-03, /03L-01:on 771229,control Rod 4,group 6,dropped Into Core Causing Power Runback to 55%.Caused by Stator R70-046133 Short Due to Moisture Buildup & O-ring Seal Failure.Stator & O-ring Seals Were Replaced + (ML19316A442)
- 05000269/LER-1977-031-03, /03L-01:on 771229,increase in Reactor Coolant Leakage Noted.Caused by Analog Channel 1 WR Transmitter Error Due to Steam from Blown Switch.Transmitter Recalibr. Valving Out Switch Stopped Leak + (ML19316A444)
- ML19316A448 + (ML19316A448)
- ML19316A449 + (ML19316A449)
- ML19316A450 + (ML19316A450)
- 05000269/LER-1978-002-03, /03L-01:on 780118,reactor Protection Sys Channel D Flow Indication Found High.Caused by Transmitter Failure Due to Blown Gasket.Gasket Replaced & Leak Stopped.Transmitter Will Be Replaced Unless It Can Be Recalibr + (ML19316A452)
- ML19316A453 + (ML19316A453)
- ML19316A454 + (ML19316A454)
- ML19316A455 + (ML19316A455)
- ML19316A456 + (ML19316A456)
- ML19316A457 + (ML19316A457)
- ML19316A458 + (ML19316A458)
- ML19316A459 + (ML19316A459)
- ML19316A460 + (ML19316A460)
- ML19316A461 + (ML19316A461)
- ML19316A462 + (ML19316A462)
- ML19316A463 + (ML19316A463)
- ML19316A464 + (ML19316A464)
- ML19316A465 + (ML19316A465)