- 05000133/LER-1980-002-03, /03L-0:on 800310,while in Cold Shutdown for Refueling & Seismic Mods,Fossil Unit Trip Test Was Not Performed within Allowable Interval.Caused by Present Status Being Unresolved.Test Will Be Performed Prior to Startup + (ML19309C349)
- 05000318/LER-1980-013-03, /03L-0:on 800303,channel Zf Pressure Input Signal for Steam Generator Isolation 22 Was Bypassed.Caused by Signal Isolater 2-E/E-1023C Being Out of Calibr Due to Nonlinear Response + (ML19309C350)
- 05000029/LER-1980-009, Forwards LER 80-009/03L-0 + (ML19309C351)
- ML19309C353 + (ML19309C353)
- ML19309C354 + (ML19309C354)
- ML19309C355 + (ML19309C355)
- ML19309C356 + (ML19309C356)
- ML19309C357 + (ML19309C357)
- 05000029/LER-1980-009-03, /03L-0:on 800307,during Maint Outage in Mode 5 While Performing Safety Injection Time Delay Verification procedure,TDC2 Setpoint Found Out of Tech Spec Limit.Caused by Setpoint Drift.Relay Adjusted to within Tech Spec Limit + (ML19309C358)
- ML19309C359 + (ML19309C359)
- ML19309C360 + (ML19309C360)
- ML19309C361 + (ML19309C361)
- 05000317/LER-1980-002, Forwards LER 80-002/04T-0 + (ML19309C362)
- ML19309C363 + (ML19309C363)
- ML19309C364 + (ML19309C364)
- ML19309C365 + (ML19309C365)
- 05000267/LER-1980-011, Forwards LER 80-011/03L-0 + (ML19309C366)
- ML19309C367 + (ML19309C367)
- ML19309C368 + (ML19309C368)
- 05000317/LER-1980-002-04, /04T-0:on 800322,instantaneous Hourly Average for Condenser Temp Rise Observed in Excess of Tech Spec Limit. Caused by Operator Inattention to Temp Rise Across Condenser & Environ Conditions + (ML19309C370)
- ML19309C371 + (ML19309C371)
- ML19309C372 + (ML19309C372)
- ML19309C373 + (ML19309C373)
- 05000267/LER-1980-011-03, /03L-0:on 800306-21,reactor Dewpoint Limiting Conditions for Operation Were Exceeded on One Occasion & Operation in Degraded Mode Occurred on Three Occasions. Caused by Problems W/Buffer Helium Sys + (ML19309C374)
- ML19309C375 + (ML19309C375)
- ML19309C376 + (ML19309C376)
- 05000327/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19309C377)
- ML19309C378 + (ML19309C378)
- ML19309C379 + (ML19309C379)
- ML19309C380 + (ML19309C380)
- 05000327/LER-1980-008-03, /03L-0:on 800303,cooling Tower Blowdown Effluent Line Flow Monitor O-FR-27-175 Was Declared Inoperable.Flow Monitor Consistently Indicated Higher Flowrate than Actually Existed.Cause Unknown.Different Instrument to Be Instal + (ML19309C381)
- 05000338/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19309C382)
- ML19309C384 + (ML19309C384)
- 05000338/LER-1980-033-03, /03L-0:on 800303,during Monthly Verification of Proper Auxiliary Feedwater Sys Valve Lineup,Discovered That Position of Valve MOV-FW100B as Written in Procedure Was Incorrect.Caused by Typographical Error in Procedure + (ML19309C385)
- ML19309C386 + (ML19309C386)
- ML19309C387 + (ML19309C387)
- ML19309C388 + (ML19309C388)
- 05000010/LER-1980-001, Forwards LER 80-001/03L-0 + (ML19309C389)
- ML19309C391 + (ML19309C391)
- ML19309C392 + (ML19309C392)
- 05000348/LER-1980-022-03, /03L-0:on 800303,during Performance of FNP-1-STP-16.7,discharge Valve to Containment Spray Header Did Not Open as Required.Cause Not Determined.Problem Did Not Reoccur W/Testing.Surveillance Test Completed + (ML19309C393)
- ML19309C394 + (ML19309C394)
- ML19309C395 + (ML19309C395)
- 05000010/LER-1980-001-03, /03L-0:on 800303,capacity in Unit 1 Fire Pump Found to Be in Need of Updating in Order to Be Equal to Unit 2/3 Fire Pump.Commitment Made to NRC to Increase Capacity.New Fire Pump Will Be Installed + (ML19309C396)
- ML19309C397 + (ML19309C397)
- ML19309C398 + (ML19309C398)
- 05000348/LER-1980-020-03, /03L-0:on 800303,inaccurate Pressure Signal Noted from PT-494,1C S/G Pressure Transmitter.Caused by Frozen Sensing Line Due to Abnormally Cold Weather & Insufficient Protection.Sensing Line Thawed & Channel Check Performed + (ML19309C399)
- ML19309C400 + (ML19309C400)
- ML19309C402 + (ML19309C402)
- ML19309C403 + (ML19309C403)
- ML19309C404 + (ML19309C404)