Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19305E770 + (ML19305E770)
- ML19305E771 + (ML19305E771)
- ML19305E772 + (ML19305E772)
- ML19305E773 + (ML19305E773)
- ML19305E774 + (ML19305E774)
- ML19305E775 + (ML19305E775)
- ML19305E776 + (ML19305E776)
- ML19305E778 + (ML19305E778)
- ML19305E779 + (ML19305E779)
- ML19305E780 + (ML19305E780)
- ML19305E781 + (ML19305E781)
- ML19305E782 + (ML19305E782)
- ML19305E783 + (ML19305E783)
- ML19305E784 + (ML19305E784)
- ML19305E787 + (ML19305E787)
- ML19305E790 + (ML19305E790)
- 05000318/LER-1980-026, Forwards LER 80-026/03L-0 + (ML19305E791)
- ML19305E792 + (ML19305E792)
- PNO-I-80-064, on 800424,util Notified NRC That 10% company- Wide Reduction in Work Force Is Being Considered.Cause Not Stated.Various Options Will Be Discussed Prior to Implementation + (ML19305E793)
- 05000259/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19305E794)
- ML19305E795 + (ML19305E795)
- PNO-I-80-065, on 800425,plant Employee Left Work Station to See Nurse About Injury.Employee Was Later Found Asleep in Car After Checks to Locate Whereabouts.Individual Was Fired But Refused to Leave Site & Had to Be Escorted + (ML19305E796)
- 05000318/LER-1980-026-03, /03L-0:on 800428,pressurizer Level Control Channels LT-110X & LT-110Y Were Removed from Svc After Erratic Changes in Pressurizer Level Occurred.Caused by Leaking Drain Valves in Transmitter 2-LT-110Y.Valves Shut + (ML19305E797)
- 05000259/LER-1980-033-03, /03L-0:on 800417,during Normal operation,480-volt Reactor Motor Operated Valve Board 1E Tripped & Locked Out on Overcurrent.Caused by Short Circuit on Hot Side of Spare Breaker Compartment 3A.Breaker Changed + (ML19305E798)
- ML19305E799 + (ML19305E799)
- ML19305E800 + (ML19305E800)
- 05000368/LER-1980-015, Forward LER 80-015/99X-0 + (ML19305E801)
- ML19305E802 + (ML19305E802)
- ML19305E803 + (ML19305E803)
- 05000368/LER-1980-015-99, /99X-0:on 800129,during Recovery from Planned Transient,Rcs Depressurized to Min of 1,350 Psia.Caused by Pressurizer Spray Valve 2CV-4651 & Steam Dump & Bypass Valve 2CV-0301 Not Fully Closing on Demand.Valves Modified + (ML19305E804)
- 05000327/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19305E805)
- ML19305E806 + (ML19305E806)
- ML19305E807 + (ML19305E807)
- 05000327/LER-1980-033-03, /03L-0:on 800411,while Core Component Pot 1-A Was Removed from Svc & 1-B Placed in Svc W/Diesel Generator 1B Out of svc,1-B Was Being Powered from Inoperable Shutdown Board.Caused by Not Verifying Generator Operability + (ML19305E808)
- ML19305E809 + (ML19305E809)
- 05000327/LER-1980-036, Forwards LER 80-036/03L-0 + (ML19305E810)
- ML19305E811 + (ML19305E811)
- ML19305E812 + (ML19305E812)
- 05000318/LER-1980-023, Forwards LER 80-023/03L-0 + (ML19305E813)
- ML19305E814 + (ML19305E814)
- 05000327/LER-1980-036-03, /03L-0:on 800413,when Source Range N-31 Was Removed from Svc,Action Statement LCO 3.9.2 Was Initiated Due to Only One Source Range Channel Being in Svc.Caused by Need to Inspect for Possible Water Damage + (ML19305E815)
- PNO-I-80-060, on 800417,Bechtel Advised Util That IE Bulletin 79-01B Pipe Break Analysis for HPCI Turbine Steam Supply Line Showed That Guillotine Break in Either Valve Isolation Rooms Adjacent to Drywell Would Overpressurize Room + (ML19305E816)
- 05000266/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19305E817)
- ML19305E818 + (ML19305E818)
- ML19305E819 + (ML19305E819)
- 05000266/LER-1980-006-03, /03L-0:on 800417,during Analysis of as-built safety-related Piping Sys Per IE Bulletin 79-14,overstressed Condition Discovered in Cooling Sys Piping.Caused by Lack of Support Between Valves Upstream of Juncture + (ML19305E821)
- 05000298/LER-1980-009, Forwards LER 80-009/03L-0 + (ML19305E822)
- ML19305E823 + (ML19305E823)
- ML19305E824 + (ML19305E824)
- 05000298/LER-1980-009-03, /03L-0:on 800329,during Refueling outage,through- Wall Crack Discovered on Upstream Side of Isolation Valve to REC Noncritical Header.Cracked Weld Characteristic of Intergranular Stress Corrosion.Weld Will Be Repaired + (ML19305E825)
- ML19305E826 + (ML19305E826)