_
80052 00 YM
.d q,
UNITED STATES y \\*s NUCLEAR REGULATORY COMMISSION CL/
2,,[$()l/',c.
- ,E WASHINGTON, D. C. 20555 Qa}
APR 2 21980 Mr. G. F. Helfrich, Director Office of Program Implementation Bureau of Oceans and International Environmental and Scientific Affairs U. S. Department of State Washingten, DC 20520
Dear Mr. Helfrich:
Enclosed please find two applications from KMS Fusion, Inc. for licenses to export tritium as microshell glass pellets to the United Kingdom and to Italy to be used as targets in laser-fusion experiments.
Before taking action on these license applications, we would appreciate your views, in accordance with established procedures and from the overall perspective of the Executive Branch, as to whether the issuance of the requested licenses would be inimical to the interests of the United States, including the conmon defense and security, and whether the proposed exports meets the applicable criteria in the Atomic Energy Act, as amended by the Nuclear Nonproliferation Act'of 1978.
Sincerely,
~
f 0
jA L W VV V Marvin R. Peterson, Acting Assistant Director Export / Import and International Safeguards Office of International Programs
Enclosures:
Appls. dtd 4/10/80 (XB001095 & XB001096) cc w/ enclosures:
Mr. Michael McDonough, DOE Mr. Richard L. Williamson, ACDA/NP/NX THis DOCUMENT CONTAINS Ms. Sheil.a Buckley, 00D P00R QUAUTY PAGES Mrs. Natalie Martin, DOE Ms. Jeanne Nelson, DOC Mr. Robin DeLaBarre, DOS
Pa== r Ec~7 u.5. ATOMIC ENERGY CoMMIS$loN Hoem approved k
10 cP t, 0.40.
Weshingtsn, D.C. 20545 APPLICATION FOR LICENSE TO EXPORT m)O9E BYPRODUCT, SOURCE, OR SPECIAL NUCLEAR MATERIAL I i e t> t o 3 Submit in Triplicate Carefully Read Instructions on Back Aoril l$38b' "
$IN>'l ^[3)_040-AL En$ fen [(U.b.)
"'"^" "
y a N A ME OF A PPLIC A N T 5 ULTlW ATE CONSIGNEE IN FOREIGN COUNTRY KMS Fusion, Inc.
(Nane and address)
Dr. John Reichelt 5'" E" ^oo* E55 Building N56, AWRE 3621 South State Road, P.O. Box 1567 Aldermastnn Civv. sT ATE.
o rip COoE Reading RG7 4 PR Ann Arbor, Michiaan 48106 (313) 769-8500 Unit'ed Kinadom
- 6. IN TERWE DI A TE CON $lGN EE IN FOREIGN COUNTRY (Cite nene 7 IF PURCN ASER IN FOREIGN COUNTRY 15 OTH ER TN AN and sd.2ress.11 same as ultimate consarner, state "Sene. ")
ULT ouATE CON 51GNE E. GIVE N A ME AND ADDRESS.
(11 same, state "Same.")
Same Same p
t fa Cu ANTITY TO BE SHIPPEO (b) COuuCOIT Y DESCRIPTION (include chenscal ard physical form; for special nuclew material mad (See t.:structrons on back) beroduct matersal also specifv isoro$uc content; if un l ets,, id ify the d t
devsce aEout 0.ernce, m"dufactusfer,
10 millicuries tritium
"'d ="d """6". / Microshel glass pel 1 mm iame p
containing a mixture of gaseous deuterium and tritium at approx-imately 10 atm.
Tritium content not to exceed 1 mci per shipment.
[
Pellets are essentially impermeable to hydrogen at room temperature.
(c) sm e
- PING AN O P ACKtHG PROCEDUR Es (Requered for special rxaclew matersal. See instructions on be-k.)
l' See attactied sheet.
? ENe v5E Or CouMoolTIES COVERED BY THIS a PPLIC ATION: (Desenbe fa'ly' stating uhat uell be produced or mamfacrated. uhat service
~
util be veradered, or the nature of the research that usil be performed.) (See instructions on back for special nuclear materia!.)
Pellets are to be used as targets in laser-fusion experiments at the Aldermas' ton i
Laboratory under the supervision of Dr. Reichelt.
j i'
JCopy to m car. ;.~'
y.2.\\-2'o'%a
..l
,.c iG The arrlicant, and any official executing this certificate on behalf of the applicant named in item 4, certify that this application is prepared in conformity with Title 10 Code of Federal Regulations. Parts 30 and 36 (if for byproduct material) or Part 40 (if for source material), or Parg 70 (if for special nuclear material), and Part 71 (for transport of radioactive material, if applicable) snd thzt all information con: Deed.% rein, including any supplements attached hereto, as true and correct to the best of their knowledge snd bqlief.
{. '. ;& C "g E KMS Fusion, Tnc.
. w, N '
e.
t3
'^
(Applicant nened in item 4) b BY:{.c.W1 aman,Radiolog1Caidarer.yutricer For H.J.
Gombera, President
+.. -O (Tstle of certufying officxa! authortzed to act on behalf of the mplica-st) i wening: 18 U.S.c. Section 1001; Act of June 25, 1948: 62 Stot. 749: makes it a criminal offense to make a willfully false state.
ment of representation to ony department or egency of ther united States os to any motter within its lurisdiction h
.Y L[m'
=
s#s#"
(
u
.w_,.
__m.+
u
,g
.m_.
KMS bSion, Inc.
Item 8(c), Application KMSF-0480-AL.
Pellets are individually mounted on a film of nitrocellulose formed in the depression of a microscope slide.
Microscope slides are packaged in plastic mailing box containers which are sealed with parafilm sealing film.
The mailing containers are sealed in a one gallon paint-type can, which is 4
cushion-packed within a 12" x 12" x 12" corrugated cardboard box, which in turn is cushion-packed within the outer 16" x 16" x 16" corrugated cardboarf, i
shipping box.
The quantity to be shipped will be less than 1 mci per shipment tritium I
gas (Transport Group VII) which is an exempt quantity.
1 i
e l
l 1
j 1
=
e f
e1 !
6
.i g
y.
y..>
e i --
T y
t Pec= AECI U.S. ATOMIC ENERGY CoMMI55foN Ferm appeeved 10 c e 40.'
Wshingtan, D.C. 20545 kM"7""" "**
APPLICATION FOR LICENSE TO EXPORT BYPRODUCT, SOURCE, OR SPECIAL NUCLEAR MATERIAL NOO k b
Submit in Trspiscate
\\I Carefully Read Instructions on Back i D ATE OF APPLIC ATION 2 A PPLIC AN T'S REF ERENC E NO-
- 3. COUNTRY OF ULTIM ATE DESTIN ATION April 10,1980
'il""*> KMSF-0480-FR Italy a N AME OF A PPLIC ANT 5 ULTIM ATE CON $1GNEE $N FOREIGN COUNTRY KMS Fusion, Inc.
@""'AY @tIo s
5'"*E
"E55 3621 South State Road, P. O. Box 1567 Laboratori Gas Ionizzati Associazione Euratom-CNEN CiTv. sT ATE ANe rip CODE Ann Arbor, Michigan 48106 (313) 769-8500 Frascati, Rome' Italy f, INTEOwEDI A TE CON 11GN EE IN FOREIGN COUNTRY (Citg= name 7 IF PURCH ASER IN FOREIGN COUNTRY l$ OTH ER TH AN and adderss. If sene as ultimate consigner, state " Sag e. ")
ULTIMATE CON $lGNEE, GIVE N AME AND ADDRESS.
(Il same, state " Sane.")
Same Same t (al CU ANTITY TO 8E $NtPPED (b) COMMODITY DESCR1PTION (include chemxcal and physscal form; for special nucire material ead iSer unstructions on ban!
byprt<tuct m.sterial also specify usatopic content; of an a devrce, identufy the devrce, manufactwer,
""#""d"""'
1 curie tritium Microshell glass pellets, about 0.1 mm diameter, containing mixtures of gaseous deuterium and tritium at approx-imately 10 atm.
Tritium content not to exceed 100 mci per ship-ment.
Pellets are essentially impermeable to hydrogen at room temperature.
(c) sulPPING AN D PACKING PROCEDUR Es (Requirru'for special rauclee maternal. See instructions on back.)
See attached sheet.
1 ENC ust OF COuuOoliICs COVERED EY TNis APPLtC ATlON. (Desenbe fully, statsng uhat usil be omduced or marasfactwed, uhar servic?
unil '~e ie <dered, or tbr nature of the redrarch that unit be pe:rfomed.)
as targets i n l ase(r e instopctsons on bacis for specual nutifusion experiments at thavmEersal.)r Sc Pe lets are to be use e
Laboratory under the supervision of Dr. Caruso.
p CU
, NFt
{
The applicant, and any official'.txtcuting this certificate on behalf of the applicant named in item 4, certify that this application io is perpered in conformity'with 'TitTe f0,, Code' of Federal Regtulations. Parts 30 and 36 (if for byproduct material) or Part 40 (if for srurce material), or Part 70 (if for special nuclear material), and Part 71 (for transport of radioactiee material, if applicable) end th:t all information contained herein, including any supplements strached hereto, is true and correct to the best of their knowledge and belief.
M PJSFr.D3 L'N8 R CM 4mn Tnn
~
~ ' ~ ~ ~ '{ API >laca t named in item 4) cCopy to FDR cad ACC 9' U 40 E,
hd
""J / 'Widman, Radiological Safety Officer f for H.J. Gombera. President-(
(Tutte o/ certsf>sne official authorszed to act on behalf of the mplicant) 5 Weming: 18 U.s.C. Section 10011 Act of June 25, 1948: 62 Stat. 749; makes it a criminal offense to mok e a willfully false state.
ment or representatioti to any deportment or ogency of the United States as to any matter within its jurisdiction 2
?
/
KMS bSIOn,Inc.
Item 8 (c), Application KMSF-0480-FR Pellets are attached to a thin post, which is supported by a polypropylene winged holder. The holders are individually sealed into 20 m1 scintillation vials, which are cushion-packe'd into a 1/2 gallon (1.43 L) paint-type can.
The can is cushion-packed into a 31 cm x 31 cm x 31 cm inner corrugated cardboard box, which in turn is cushion-packed into the outer 41 cm x 41 cm x'41 cm corrugated cardboard box.
The quantity to be shipped will be less than 100 mci per shipment of tritium gas (Transport group VII) which is an exempt quantity.
I 6
s b
t:
%