- 05000366/LER-1980-010-03, /03L-0:on 800131,during Reactor Startup,At 58% Power,Max Total Peaking Factor Was Calculated at 3.0 Compared to Design Value of 2.38.Caused by Lower than Normal Xenon Distribution During Startup + (ML19294A972)
- ML19294A974 + (ML19294A974)
- ML19294A976 + (ML19294A976)
- ML19294A978 + (ML19294A978)
- ML19294A980 + (ML19294A980)
- 05000155/LER-1980-002-03, /03L-0:on 800124,during Monthly Specific Gravity Checks,Cell 14 of Battery for Channel C of Reactor Depressurizing Sys Read Below Tech Spec.Cause Not Stated. Channel Removed from Svc to Replace Defective Cell + (ML19294A981)
- ML19294A982 + (ML19294A982)
- ML19294A983 + (ML19294A983)
- 05000155/LER-1980-003-03, /03L-0:on 800123,following Automatic Test Circuit Alarm Indication,Channel D of Reactor Depressurizing Sys Removed from Svc for Troubleshooting.Caused by Automatic Test Circuit Component Failure + (ML19294A986)
- ML19294A989 + (ML19294A989)
- 05000325/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19294A991)
- ML19294A992 + (ML19294A992)
- ML19294A993 + (ML19294A993)
- 05000325/LER-1980-013-03, /03L-0:on 800125,while Performing Reactor Low Water Level 2 & 3 Channel Calibr & Functional Check,Low Pressure Switch 1B21-LITS-N031A-2 Failed to Actuate.Caused by Instrument Drift.Instruments to Be Replaced + (ML19294A995)
- ML19294A996 + (ML19294A996)
- 05000302/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19294A997)
- ML19294A998 + (ML19294A998)
- ML19294A999 + (ML19294A999)
- 05000302/LER-1980-006-03, /03L-0:on 800123,during Routine Surveillance, Reactor Bldg Charcoal Filter Bank Efficiency Was Less than 99%.Caused by Natural End of Life for Filter.Filters Replaced + (ML19294B001)
- ML19294B002 + (ML19294B002)
- 05000282/LER-1980-005, Forwards LER 80-005/03L-0 + (ML19294B003)
- ML19294B004 + (ML19294B004)
- ML19294B005 + (ML19294B005)
- 05000282/LER-1980-005-03, /03L-0:on 800121,during Surveillance Test of D1 Diesel Generator,Lockout Occurred While Engine Was Being Prelubed.Caused by Abnormally Cold Generator Room.Caution Will Be Added to Procedure to Monitor Lube Oil Pressure + (ML19294B007)
- ML19294B008 + (ML19294B008)
- 05000366/LER-1980-016, Forwards LER 80-016/03L-0 + (ML19294B009)
- ML19294B010 + (ML19294B010)
- 05000285/LER-1980-003, Forwards LER 80-003/03L-0 + (ML19294B011)
- ML19294B012 + (ML19294B012)
- 05000285/LER-1980-003-03, /03L-0:on 800122,during Special 24-h Diesel Generator Test,While Attempting to Load Generator,Generator Field Went to Max Excitation.Caused by Faulty Zener Diode & Corresponding Draft in A-C Regulator Panel + (ML19294B014)
- ML19294B016 + (ML19294B016)
- ML19294B017 + (ML19294B017)
- 05000366/LER-1980-016-03, /03L-0:on 800130,w/reactor in Run Mode,Auxiliary Oil Pump Feeder Breaker Tripped While HPCI Auxiliary Oil Pump Was Running to Obtain Oil Sample.Caused by Failure of Coil of Time Delay Relay.Coil Was Replaced + (ML19294B018)
- ML19294B021 + (ML19294B021)
- ML19294B022 + (ML19294B022)
- ML19294B024 + (ML19294B024)
- ML19294B025 + (ML19294B025)
- ML19294B027 + (ML19294B027)
- ML19294B028 + (ML19294B028)
- ML19294B030 + (ML19294B030)
- ML19294B031 + (ML19294B031)
- ML19294B032 + (ML19294B032)
- ML19294B033 + (ML19294B033)
- ML19294B034 + (ML19294B034)
- ML19294B036 + (ML19294B036)
- ML19294B037 + (ML19294B037)
- ML19294B038 + (ML19294B038)
- ML19294B040 + (ML19294B040)
- ML19294B042 + (ML19294B042)
- ML19294B043 + (ML19294B043)
- ML19294B044 + (ML19294B044)