- 05000338/LER-1978-051, Forwards LER 78-051/01X-1 + (ML19289C588)
- ML19289C589 + (ML19289C589)
- 05000338/LER-1978-051-01, /01X-1 on 780614:auxiliary Feedwater Pump start-up Delay Due to Improper Adjustment of Instantaneous Contracts on an Aquastat 2400 Series Relay + (ML19289C590)
- 05000278/LER-1978-024-03, /03L-0 on 781212:reactor Core Isolation Cooling Valve Mo-13-15 Failed to Close During Surveillance Test 6.11.Caused by Cocked Packing Follower Jamming Valve Stem + (ML19289C591)
- AECM-78-104, Findings of Investigation of Normal Reactor Protection Sys Power Supplies Will Be Available by 790301,rather than 790103 as Reported in + (ML19289C592)
- ML19289C593 + (ML19289C593)
- 05000338/LER-1978-130, Forwards LER 78-130/03L-0,78-133/03L-0 & 78-135/03L-0 + (ML19289C594)
- ML19289C595 + (ML19289C595)
- ML19289C596 + (ML19289C596)
- 05000271/LER-1978-020, Forwards LER 78-020/01T-1 + (ML19289C597)
- ML19289C598 + (ML19289C598)
- 05000338/LER-1978-130-03, /03L-0 on 781220:during incore-excore Detector Cross Calibr,Axial Flux Deviated Contrary to Tech Specs. Caused by Personnel Error + (ML19289C599)
- ML19289C600 + (ML19289C600)
- 05000271/LER-1978-020-01, /01T-1 on 780701:growing Crack Was Observed in Torus Shell Adjacent to Weld.Caused by Failure of a Certain Welding Process to Produce the Desired Results in Metallurgical Properties + (ML19289C601)
- 05000338/LER-1978-133-03, /03L-0 on 781226:Loop a Steam Flow Indicator (FI-1474)indicated High W/Re to Its Redundant Indicator. Caused by Reference Leg Flashing Due to Steam Leak on Root Isolation Valve 1-MS-4 + (ML19289C602)
- 05000338/LER-1978-135-03, /03L-0 on 781226:axial Flux Difference Deviated Beyond Tech Spec Limit Due to Power Reduction Caused by Steam Leak in Drain Line of D Moisture Separator + (ML19289C603)
- ML19289C604 + (ML19289C604)
- ML19289C605 + (ML19289C605)
- ML19289C606 + (ML19289C606)
- ML19289C607 + (ML19289C607)
- ML19289C608 + (ML19289C608)
- ML19289C610 + (ML19289C610)
- ML19289C616 + (ML19289C616)
- ML19289C618 + (ML19289C618)
- ML19289C628 + (ML19289C628)
- ML19289C629 + (ML19289C629)
- ML19289C631 + (ML19289C631)
- ML19289C633 + (ML19289C633)
- ML19289C635 + (ML19289C635)
- ML19289C638 + (ML19289C638)
- IR 07200201/1990004 + (ML19289C639)
- ML19289C642 + (ML19289C642)
- ML19289C643 + (ML19289C643)
- ML19289C644 + (ML19289C644)
- ML19289C645 + (ML19289C645)
- ML19289C646 + (ML19289C646)
- ML19289C647 + (ML19289C647)
- 05000321/LER-1978-098, Forwards LER 78-098/03L-0 + (ML19289C649)
- ML19289C650 + (ML19289C650)
- 05000333/LER-1978-108, Forwards LER 78-108/04L-0 + (ML19289C651)
- ML19289C652 + (ML19289C652)
- ML19289C653 + (ML19289C653)
- 05000333/LER-1978-108-04, /04L-0 on 781217:apparent Excessive Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel.Cause Not Stated + (ML19289C654)
- ML19289C655 + (ML19289C655)
- 05000321/LER-1978-098-03, /03L-0 on 781226:during Operation,Discovered Core Spray Sparger Differential Pressure Instrument Check Omitted from HNP-1-1050 Surveillance Check.Caused by Issuance of Revision 9 HNP-1-1050 Which Omitted the Check + (ML19289C656)
- ML19289C657 + (ML19289C657)
- ML19289C658 + (ML19289C658)
- ML19289C659 + (ML19289C659)
- ML19289C661 + (ML19289C661)
- ML19289C663 + (ML19289C663)
- ML19289C664 + (ML19289C664)