- 05000333/LER-1979-116, Forwards LER 79-116/03L-0 + (ML19257B984)
- ML19257B985 + (ML19257B985)
- 05000366/LER-1979-139, Forwards LER 79-139/03L-0 + (ML19257B986)
- ML19257B987 + (ML19257B987)
- 05000346/LER-1979-133-03, /03L-0:on 791219,calculations by Itt Grinnell Revealed Seismic Support Design High Pressure Injection Line Exceeded Slenderness Design Ratio.Caused by Failure to Correctly Evaluate Slenderness Ratio.Mods Completed 791223 + (ML19257B989)
- 05000333/LER-1979-116-03, /03L-0:on 791227,following Reactor Scram & During Plant Startup,Several Problems Occured w/source-range Monitors.Seven Instances Noted.Followup Rept Describing Corrective Action Will Be Submitted + (ML19257B990)
- 05000321/LER-1980-001, Forwards LER 80-001/01T-0 + (ML19257B991)
- ML19257B992 + (ML19257B992)
- 05000366/LER-1979-139-03, /03L-0:on 791228,while Performing Diesel Generator Manual Start,Diesel Generator 2A Failed to Start within Seven Seconds.Caused by Foreign Object Lodged in Diesel Fuel Supply Line Check Valve.Check Valve Cleaned + (ML19257B993)
- 05000325/LER-1979-113, Forwards LER 79-113/03L-0 + (ML19257B994)
- ML19257B995 + (ML19257B995)
- 05000321/LER-1980-001-01, /01T-0:on 800103,while Performing Maint on RHR LPCI Injection Valve,Clevis Pin Found Missing from Strut on Drywell Penetration Restraint.Caused by Improper Installation.New Clevis Pin Installed + (ML19257B996)
- 05000325/LER-1979-113-03, /03L-0:on 791219,during Reactor Startup,Rhr Torus Suction Valve F004C Found Shut During Shift Turnover,Causing RHR Pump to Be Inoperable.Caused by Failure to Manually Return Valve to Correct Position After Shutdown Cooling + (ML19257B997)
- ML19257B998 + (ML19257B998)
- ML19257B999 + (ML19257B999)
- 05000316/LER-1979-051-03, /03L-0:on 791217,w/reactor in Mode 5,containment Spray Pump Discharge Valve Failed to Open.Caused by Limitorque Switch Binding Operator Mechanism.Torque Switch & Drive Motor Replaced + (ML19257C000)
- ML19257C001 + (ML19257C001)
- 05000338/LER-1980-002, Forwards LER 80-002/01T-0 + (ML19257C002)
- ML19257C003 + (ML19257C003)
- 05000309/LER-1979-031, Forwards LER 79-031/03L-0 + (ML19257C004)
- 05000309/LER-1979-031-03, /03L-0:on 791227,during Special Test of Reactor Protection Sys,One Set of Relay Contacts on Each of Two Trip Matrix Relays Found Not Operating Reliably Upon de-energization of Relay.Caused Not Stated + (ML19257C006)
- ML19257C007 + (ML19257C007)
- 05000282/LER-1980-001, Forwards LER 80-001/01T-0 + (ML19257C008)
- ML19257C009 + (ML19257C009)
- 05000346/LER-1980-001, Forwards LER 80-001/01T-0 + (ML19257C010)
- ML19257C011 + (ML19257C011)
- 05000338/LER-1980-002-01, /01T-0:on 800107,S&W Informed Util That Stress on Vertical Supports RH-R-19 & WS-R-316 & Snubbers SI-HSS-101B,101C & 107A Exceeded Allowable Design Values. Caused by Wrong Valve Weights Used in Design Calculations + (ML19257C012)
- 05000282/LER-1980-001-01, /01T-0:on 800106,Unit 1 Caustic Addition Valves CA-1-2 & CA-1-4 Mistakenly Closed & Secure Cards Attached. Caused by Personnel Error & Procedural Inadequacies. Administrative Procedures Modified + (ML19257C013)
- 05000366/LER-1980-001, Forwards LER 80-001/03L-0 + (ML19257C014)
- ML19257C015 + (ML19257C015)
- ML19257C016 + (ML19257C016)
- 05000366/LER-1980-001-03, /03L-0:on 800102,while Performing Narrow Range Torus Water Level Functional Test & Calibr,Level Transmitter 2T48-N021B Found Out of Tolerance.Caused by Range Drift. Transmitter Recalibr & Returned to Svc + (ML19257C017)
- ML19257C018 + (ML19257C018)
- ML19257C019 + (ML19257C019)
- ML19257C020 + (ML19257C020)
- ML19257C021 + (ML19257C021)
- ML19257C022 + (ML19257C022)
- ML19257C023 + (ML19257C023)
- ML19257C024 + (ML19257C024)
- ML19257C025 + (ML19257C025)
- 05000316/LER-1979-052-03, /03L-0:on 791218,w/reactor in Mode 5,source Range Indication Was Inoperable for 23 Minutes.Caused by Maint Error While Working on Energized Equipment.Workers Reprimanded & Addl Training Held + (ML19257C026)
- ML19257C027 + (ML19257C027)
- ML19257C033 + (ML19257C033)
- ML19257C034 + (ML19257C034)
- ML19257C035 + (ML19257C035)
- ML19257C037 + (ML19257C037)
- ML19257C038 + (ML19257C038)
- ML19257C039 + (ML19257C039)
- ML19257C040 + (ML19257C040)
- ML19257C041 + (ML19257C041)
- ML19257C042 + (ML19257C042)