- 05000298/LER-1979-012, Forwards LER 79-012/03L-0 + (ML19224D793)
- ML19224D794 + (ML19224D794)
- ML19224D795 + (ML19224D795)
- 05000321/LER-1979-041, Forwards LER 79-041/03L-0 + (ML19224D796)
- 05000298/LER-1979-012-03, /03L-0 on 790503:vessel Water Temp Increased to 220 F W/Primary Containment Integrity Not Established.Caused by Omission in Operating Procedures.Setpoint of Interlock Verified & Procedures Revised + (ML19224D798)
- ML19224D799 + (ML19224D799)
- 05000348/LER-1979-025-03, /03L-0 on 790623:during Surveillance Test FNP-1-STP-256.11 Both Source Range Channels Inadvertently Were Deenergized. Caused by Procedure Deficiency. Power Restored & Procedure Changed + (ML19224D800)
- 05000321/LER-1979-041-03, /03L-0 on 790624:diesel Generator Tripped While Performing Procedure HNP-1-3801.Cause Not Yet Determined. Procedure Performed Again Successfully.Investigation Is in Progress + (ML19224D801)
- ML19224D804 + (ML19224D804)
- 05000298/LER-1979-013, Forwards LER 79-013/03L-0 + (ML19224D805)
- ML19224D806 + (ML19224D806)
- 05000298/LER-1979-013-03, /03L-0 on 790508:correct Drywell to Suppression Chamber Reading Not Established.Caused by Leaking Inlet Purge Valve.Valve Repaired & Leak Tested + (ML19224D808)
- ML19224D809 + (ML19224D809)
- ML19224D811 + (ML19224D811)
- ML19224D812 + (ML19224D812)
- ML19224D813 + (ML19224D813)
- ML19224D815 + (ML19224D815)
- 05000298/LER-1979-014, Forwards LER 79-014/03L-0 + (ML19224D816)
- ML19224D817 + (ML19224D817)
- ML19224D818 + (ML19224D818)
- 05000298/LER-1979-014-03, /03L-0 on 790509:chamber Vent Valve for Torus Level Transmitter Was Left Closed.Caused by Technician Error.Vent Valve Opened & PC-LT-12 Placed Back Into Svc + (ML19224D819)
- ML19224D822 + (ML19224D822)
- 05000336/LER-1979-015, Forwards LER 79-015/03L-0 + (ML19224D823)
- ML19224D824 + (ML19224D824)
- 05000366/LER-1979-056, Forwards LER 79-056/03L-0 + (ML19224D825)
- ML19224D826 + (ML19224D826)
- 05000336/LER-1979-015-03, /03L-0 on 790610:leak Identified in RCS & Traced to Isolation Valve.Cause Unknown.Isolation Valve Repaired & power-operated Relief Valve Declared Operable + (ML19224D828)
- ML19224D829 + (ML19224D829)
- ML19224D830 + (ML19224D830)
- 05000366/LER-1979-056-03, /03L-0 on 790620:during Startup Test,Reactor Core Isolation Exhaust & RHR Heat Exchanger Vents to Torus Increased Water Level to 150.9 Inches,Exceeding Tech Specs. Drainage Decreased Water Level Below Limit within One Hour + (ML19224D831)
- 05000250/LER-1979-022, Forwards LER 79-022/01T-0 + (ML19224D833)
- ML19224D834 + (ML19224D834)
- 05000366/LER-1979-054, Forwards LER 79-054/03L-0 + (ML19224D835)
- ML19224D836 + (ML19224D836)
- 05000250/LER-1979-022-01, /01T-0 on 790626:loss of 3B 4160 V Bus Would Not Result in Automatic Transfer of Shared D Motor Ctr to Alternative Supply from 4A 4160 V Bus.Operating Procedures Are Being Revised to Correct Situation + (ML19224D837)
- 05000366/LER-1979-054-03, /03L-0 on 790619:drywell Pressure Exceeded Tech Specs Limit Following Shutdown from Load Reject Test.Caused by Loss of Drywell Cooling from Tripped Chillers.Drywell Venting Returned Pressure Below Limit within 15 Minutes + (ML19225A004)
- ML19225A005 + (ML19225A005)
- ML19225A006 + (ML19225A006)
- ML19225A007 + (ML19225A007)
- ML19225A008 + (ML19225A008)
- ML19225A011 + (ML19225A011)
- 05000334/LER-1979-017-03, /03L-0 on 790609:during insp,1B Lhsi Pump Suction Valve from Refueling Water Storage Tank Found Inoperable. Caused by Failure of Motor Operator Torque Switch.Switch Assembly Replaced,Tested & Returned to Svc + (ML19225A012)
- 05000336/LER-1979-016-03, /03L-0 on 790611:pressurizer Pressure Channel for One of Two power-operated Pressurizer Relief Valves Found to Be Reading 250 PSI Lower than Actual Pressure.Caused by Shift at Zero Point.Zero Point Readjusted + (ML19225A013)
- ML19225A021 + (ML19225A021)
- ML19225A023 + (ML19225A023)
- 05000250/LER-1979-021, Forwards LER 79-021/01T-0 + (ML19225A024)
- ML19225A025 + (ML19225A025)
- ML19225A026 + (ML19225A026)