Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19210E300 + (ML19210E300)
- ML19210E302 + (ML19210E302)
- ML19210E303 + (ML19210E303)
- 05000333/LER-1979-095, Forwards LER 79-095/03X-1 + (ML19210E304)
- ML19210E305 + (ML19210E305)
- 05000338/LER-1979-150, Forwards LER 79-150/03L-0 + (ML19210E306)
- ML19210E307 + (ML19210E307)
- 05000333/LER-1979-095-03, /03X-1:on 791025,drywell-to-suppression Chamber Differential Pressure Transmitter 27-PT-102B Was Found Out of Tolerance.Caused by Improper Testing Procedure.Procedure Corrected & Proper Calibr Verified + (ML19210E308)
- 05000338/LER-1979-150-03, /03L-0;on 791101,during Refueling Shutdown, Discovered Failure to Perform Required Weekly Surveillance of Dc Distribution Sys.Caused by Loss of Administrative Control.Sys Tested & Personnel Notified of Error + (ML19210E309)
- 05000267/LER-1979-057, Forwards LER 79-057/03L-0 + (ML19210E310)
- ML19210E311 + (ML19210E311)
- 05000267/LER-1979-057-03, /03L-0:on 791030,during Surveillance Testing,One of Three Reactor Pressure Transmitters Found Out of Calibr. Instrument Settings Less Conservative than Required.Caused by Instrument Drift.Instrument Recalibr + (ML19210E312)
- 05000309/LER-1979-028, Forwards LER 79-028/03L-0 + (ML19210E313)
- 05000267/LER-1979-052, Forwards LER 79-052/03L-0 + (ML19210E315)
- ML19210E316 + (ML19210E316)
- ML19210E317 + (ML19210E317)
- 05000309/LER-1979-028-03, /03L-0:on 791031,one Set of Relay Contacts on Each of Three Separate Reactor Trip Matrix Relays Were Not Opening Reliably.Cause Not Stated.Three CP Clare,Mercury Wetted Relay Modules,Type HG2X-1011,replaced + (ML19210E319)
- 05000267/LER-1979-052-03, /03L-0:on 791022,at 9% Power B Instrument Air Compressor Found to Have Insufficient Output While a Compressor Out of Svc.Caused by Bent Piston Rod & Worn Valves.Parts Replaced or Rebuilt + (ML19210E320)
- ML19210E321 + (ML19210E321)
- 05000267/LER-1979-053, Forwards LER 79-053/03L-0 + (ML19210E322)
- ML19210E323 + (ML19210E323)
- ML19210E324 + (ML19210E324)
- 05000267/LER-1979-053-03, /03L-0:on 791024,total Primary Coolant Oxidants Exceeded 10 Parts Per Million.Caused by off-gassing of Oxidants Due to Reaction of Moisture W/Core Graphite.Power Decreased to Initiate Maint Shutdown + (ML19210E325)
- ML19210E326 + (ML19210E326)
- 05000267/LER-1979-051, Forwards LER 79-051/03L-0 + (ML19210E327)
- ML19210E328 + (ML19210E328)
- 05000267/LER-1979-051-03, /03L-0:on 791017,at 5% Power,Sys 21 Loop 1 Surge Tank Level Decreased to Low Level Setpoint,Tripping Loop 1 Bearing Water Pumps & Making Circulators Inoperable.Caused by Procedural Inadequacy & Operator Error + (ML19210E329)
- ML19210E330 + (ML19210E330)
- ML19210E331 + (ML19210E331)
- ML19210E333 + (ML19210E333)
- ML19210E334 + (ML19210E334)
- ML19210E335 + (ML19210E335)
- ML19210E337 + (ML19210E337)
- ML19210E338 + (ML19210E338)
- 05000267/LER-1979-055, Forwards LER 79-055/03L-0 + (ML19210E339)
- ML19210E340 + (ML19210E340)
- 05000267/LER-1979-055-03, /03L-0:on 791026,during Surveillance Testing,Check Valve V-22370 Was Stuck Open,Making Fire Water Booster Pumps Inoperable for Helium Circulator Drive.Cause Unknown.Valve to Be Opened & Inspected + (ML19210E341)
- ML19210E342 + (ML19210E342)
- 05000348/LER-1979-053, Forwards LER 79-053/03L-0 + (ML19210E344)
- ML19210E345 + (ML19210E345)
- ML19210E346 + (ML19210E346)
- ML19210E347 + (ML19210E347)
- ML19210E348 + (ML19210E348)
- 05000348/LER-1979-053-03, /03L-0:on 791101,rod K-14 in Control Bank a Declared Inoperable Due to Failure to Move in or Out During Manual Bank Movement.Caused by Open Control Rod Drive Mechanism Cable Making Power Unavailable to K-14 Lift Coil + (ML19210E349)
- ML19210E350 + (ML19210E350)
- ML19210E352 + (ML19210E352)
- 05000309/LER-1979-027, Forwards LER 79-027/03L-0 + (ML19210E353)
- ML19210E355 + (ML19210E355)
- ML19210E359 + (ML19210E359)
- 05000309/LER-1979-027-03, /03L-0:on 791029,leakage Near Safety Injection Tank Discharge Check Valve 1 Exceeded Tech Spec Limits. Caused by O-ring Failure on Bearing Cap of Swing Check valve.O-ring Replaced & Bearing Cap Seal Welded + (ML19210E360)
- 05000278/LER-1979-034-03, /03L-0:on 791101,during Surveillance Testing, Standby Liquid Control Pump Relief Valve Operated Below Tech Spec Limit.Caused by Setpoint Drift on Jmsk Crosby Valve. Valve Readjusted within Tech Spec Limit + (ML19210E362)