- 05000272/LER-1991-023, :on 910612,two Channels in Single Sys Inoperable.Caused by Equipment Failure.Pump Belts Replaced & & Pump Restored to Svc.Tech Spec Action Statements Exited + (ML18096A124)
- 05000272/LER-1991-022, :on 910606,two ESF Actuations Occurred.Caused by Personnel Error & Inadequate Human Factors Design.Bus Cubicle Design Reviewed to Determine Feasibility for Installation of More Accessible Connections + (ML18096A125)
- ML18096A126 + (ML18096A126)
- ML18096A128 + (ML18096A128)
- ML18096A129 + (ML18096A129)
- ML18096A131 + (ML18096A131)
- ML18096A133 + (ML18096A133)
- IR 05000272/1991009 + (ML18096A134)
- IR 05000272/1991017 + (ML18096A135)
- ML18096A136 + (ML18096A136)
- ML18096A137 + (ML18096A137)
- ML18096A140 + (ML18096A140)
- ML18096A141 + (ML18096A141)
- 05000272/LER-1991-024, :on 910616,reactor Trip from 100% Power Occurred.Caused by Lightning Strike.Engineering Review & Review of Lightning Protection Features Initiated & Damage to Phase B Gsu Transformer Repaired + (ML18096A142)
- ML18096A143 + (ML18096A143)
- ML18096A145 + (ML18096A145)
- ML18096A146 + (ML18096A146)
- ML18096A147 + (ML18096A147)
- ML18096A148 + (ML18096A148)
- ML18096A149 + (ML18096A149)
- ML18096A151 + (ML18096A151)
- ML18096A152 + (ML18096A152)
- ML18096A153 + (ML18096A153)
- ML18096A154 + (ML18096A154)
- ML18096A156 + (ML18096A156)
- ML18096A158 + (ML18096A158)
- ML18096A159 + (ML18096A159)
- ML18096A160 + (ML18096A160)
- ML18096A161 + (ML18096A161)
- ML18096A162 + (ML18096A162)
- ML18096A163 + (ML18096A163)
- ML18096A168 + (ML18096A168)
- IR 05000272/1991020 + (ML18096A170)
- ML18096A171 + (ML18096A171)
- ML18096A173 + (ML18096A173)
- ML18096A174 + (ML18096A174)
- ML18096A175 + (ML18096A175)
- ML18096A176 + (ML18096A176)
- 05000311/LER-1991-009-02, :on 910630,ESF Actuation Occurred as 21 Motor Driven Auxiliary Feedwater Pump Started.Caused by Equipment Failure.Failed Ssps Output Card Replaced & Results of Study Assessed to Determine Preventive Measures + (ML18096A177)