- 05000316/LER-1980-028-03, /03L-0:on 800709,testing of Motor Driven Auxiliary Feedwater Pump During Blackout Conditions Showed Two Safety Injection Relay Timers Exceeded Tech Spec Allowed Tolerance.Caused by Instrument Drift + (ML17331A408)
- 05000316/LER-1979-026-03, While Reviewing Axial Power Distribution Monitoring Sys,Two Occasions Were Discovered in Which Only One Detector Scan Was Printed Out. Cause Undetermined.Investigation Closed + (ML17331A409)
- ML17331A410 + (ML17331A410)
- 05000315/LER-1980-015-03, /03L-0:on 800703,in Mode 6,train B Centrifugal Charging Pump Failed While Running Due to Broken Pump Shaft. Cause Unknown.Pump Rebuilt Using New Design Shaft + (ML17331A411)
- ML17331A416 + (ML17331A416)
- ML17331A418 + (ML17331A418)
- ML17331A419 + (ML17331A419)
- ML17331A420 + (ML17331A420)
- 05000315/LER-1980-016-03, /03L-0:on 800720,during Automatic Load Sequence Timing Relay Surveillance Test,Timer for 1E-MDAFP Exceeded Max Allowable Time.Caused by Instrument Drift.Timer Reset & Retested + (ML17331A421)
- 05000316/LER-1980-029, Forwards LER 80-029/03L-0 + (ML17331A422)
- ML17331A423 + (ML17331A423)
- 05000316/LER-1980-029-03, /03L-0:on 800721,while Investigating Frequent Filter Not in Motion Alarms on Containment Apd (R-11),filter Paper Motor Bound Up,Stopping Filter Paper & Rendering R-11 Inoperable.Caused by Bad Bearing on Motor + (ML17331A424)
- ML17331A426 + (ML17331A426)
- 05000315/LER-1980-017, Forwards LER 80-017/03L-0 + (ML17331A427)
- ML17331A428 + (ML17331A428)
- 05000315/LER-1980-017-03, /03L-0:on 800804,during Low Power Physics Test After Refueling,Boron Injection Tank Discovered to Have Boron Concentration Below Required Min.Caused by Inadequate Mixing Due to Low Recirculation Flow + (ML17331A429)
- ML17331A432 + (ML17331A432)
- 05000315/LER-1980-018-03, /03L-0:on 800806,during post-refueling Startup,Rcs Average Temp Fell Below 541 F Contrary to Tech Spec 3.1.1.5. Caused by Unbalance Between Turbine Load & Reactor Power. Turbine Load Reduced + (ML17331A433)
- ML17331A434 + (ML17331A434)
- 05000315/LER-1980-019-03, /03L-0:on 800811,while Performing Surveillance Re Tech Spec 3.8.2.1.1 Requirements for Inoperable Diesel Generator,Requirement 4.8.1.1.1a Was Not Performed.Caused by Inadequate Surveillance Procedures + (ML17331A435)
- ML17331A436 + (ML17331A436)
- ML17331A439 + (ML17331A439)
- ML17331A440 + (ML17331A440)
- ML17331A441 + (ML17331A441)
- 05000315/LER-1980-021, Forwards LER 80-021/03L-0 + (ML17331A443)
- ML17331A444 + (ML17331A444)
- 05000315/LER-1980-021-03, /03L-0:on 800817 During Insp,Two Intermediate Deck Doors Were Found Frozen Shut.Caused by Water from Top Deck Divider Beams.Design Change Submitted to Insulate Divider Beams to Prevent Condensation + (ML17331A446)
- 05000316/LER-1980-030, Forwards LER 80-030/03L-0 + (ML17331A447)
- ML17331A448 + (ML17331A448)
- 05000316/LER-1980-030-03, /03L-0:on 800814,during Normal Operation,Radiation Monitor R11 Alarmed.Investigation Showed R-11 & R-12 Sample Pumps Seized.Caused by Wear.Pump Replaced & Monitors Returned to Svc + (ML17331A449)
- ML17331A451 + (ML17331A451)
- ML17331A456 + (ML17331A456)
- ML17331A458 + (ML17331A458)
- 05000315/LER-1980-020-03, /03L-0:on 800831,during Normal Operation,Unit Trip & Train a Safety Injection & Steam Line Isolation Occurred. Caused by Shorted Diode in Crid 4 Inverter.All Diodes & Oscillator Boards Replaced,Tested & Returned to Svc + (ML17331A460)
- ML17331A461 + (ML17331A461)
- ML17331A462 + (ML17331A462)
- ML17331A464 + (ML17331A464)
- ML17331A465 + (ML17331A465)
- ML17331A466 + (ML17331A466)
- ML17331A467 + (ML17331A467)
- 05000316/LER-1980-031-03, /03L-0:on 800902,bistable for Containment Pressure hi-hi Protection Set II Tripped at 3.1005 Psig,Exceeding Limiting Conditions for Operation.Caused by Instrument Drift.Bistable Adjusted & Returned to Svc + (ML17331A468)
- 05000316/LER-1980-032-03, /03L-0:on 800904,while Returning East RHR Pump to Svc After Maint,Pump Became Unstable & Declared Inoperable. Caused by Air in Sys During Fill & Vent.Procedure Changed & Problem Eliminated + (ML17331A469)
- 05000315/LER-1980-023, Forwards LER 80-023/03L-0 + (ML17331A470)
- ML17331A471 + (ML17331A471)
- L-17-348, Discharge Monitoring Report (NPDES) Permit No. PA0025615 + (ML17331A472)
- 05000315/LER-1980-023-03, /03L-0:on 800916,steam Generator 2 Channel 3 Level Indication Was Found to Be Indicating 6% Lower than Other Channels.Caused by Pinhole Leak in Impulse Line at Socket Weld.Repaired & Returned to Svc + (ML17331A473)
- ML17331A477 + (ML17331A477)
- ML17331A479 + (ML17331A479)
- ML17331A481 + (ML17331A481)
- ML17331A483 + (ML17331A483)
- BSEP 17-0017, Submittal of Request for License Amendment for Performance-Based Fire Protection Alternative for Thermal Insulation Material + (ML17331A484)