Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17261A124 + (ML17261A124)
- 05000244/LER-1979-011-01, /01T-0 on 790511:notified by Manufacturer of Pressurizer Power Operated Relief Valve That Template Used to Fabricate Valve Internals Not within Specs.Caused by Error in Tracer Lathe Template + (ML17261A125)
- ML17261A126 + (ML17261A126)
- ML17261A128 + (ML17261A128)
- ML17261A129 + (ML17261A129)
- 05000244/LER-1979-012-01, /01X-1 on 790327:several Anchor Bolts Identified as Not Being in Accordance W/Drawing During Inservice Insp. Caused by Inadequate Control of Const Installation.Anchor Bolts Corrected + (ML17261A130)
- 05000244/LER-1979-013-01, /01T-0 on 790707:during Ultrasonic & Radiographic Examination of Steam Generator Feedwater nozzle-to-elbow Welds,Small Linear Indications in Elbows Were Found.Cause Not Identified.Elbows Replaced + (ML17261A131)
- 05000244/LER-1979-014-03, /03L-0 on 790709:during RCS Cooldown,Operator Noted Channel P-452 Overpressurization Alarm Not in Correct State.Caused by Bistable Setpoint Drift.Alarm Unit Replaced + (ML17261A135)
- ML17261A136 + (ML17261A136)
- ML17261A137 + (ML17261A137)
- 05000244/LER-1979-016-01, /01T-0 on 790804:14-h Interval of Reactor Operation Lapsed Prior to Trip During Trip Testing Following Maint Outage & Restoration of Criticality.Caused by Unclear Checkoff procedure.On-shift Training Held + (ML17261A138)
- 05000244/LER-1979-008-03, /03X-1 on 790406:during Maint on Boric Acid Flow Control Valve,Leaks Noted on Valve Outlet 1-inch Nipple. Caused by External Caustic Pitting.Actions to Minimize Caustics & Chlorides Are Being Taken + (ML17261A139)
- ML17261A140 + (ML17261A140)
- 05000244/LER-1979-017-01, /01T-0:on 790831,analysis of Boric Acid Storage Tank Samples Revealed Concentrations Above 13% Limits. Possibly Due to Evaporation,Redissolution of Crystals or Sampling Error.Load Reduction Begun & Levels Restored + (ML17261A141)
- ML17261A142 + (ML17261A142)
- ML17261A144 + (ML17261A144)
- 05000244/LER-1979-019-03, /03L-0:on 790919,loose Nuts on Anchor Bolts Were Found on Pipe Supports & on Svc Water Piping to Standby Auxiliary Feedwater Pump.Caused by Nuts Working Loose During Sys Operation.Nuts Were Torqued to Current Requirement + (ML17261A145)
- 05000244/LER-1979-020-03, /03L-0:on 791009,during Snubber Insp,Snubber in Position MS146 Found W/No Accumulator Level.Caused by Movement of Pipe Resulting in Wear on Accumulator & Eventual Failure of Shaft Seal.Unit Replaced W/Spare + (ML17261A146)
- ML17261A147 + (ML17261A147)
- 05000244/LER-1979-021-03, /03L-0:on 791018,Tech Spec Requirement 4.8.5 Re Stroking Crossover Valves Omitted from Procedure for Testing Standby Auxiliary Feedwater Pumps.Caused by Personnel Error. Test Personnel Briefed & Performed Tests + (ML17261A148)
- ML17261A149 + (ML17261A149)
- ML17261A150 + (ML17261A150)
- ML17261A151 + (ML17261A151)
- ML17261A152 + (ML17261A152)
- ML17261A153 + (ML17261A153)
- ML17261A154 + (ML17261A154)
- ML17261A155 + (ML17261A155)
- 05000244/LER-1979-022, Forwards LER 79-022/01T-0 + (ML17261A156)
- ML17261A157 + (ML17261A157)
- 05000244/LER-1979-022-01, /01T-0:on 791201,during Normal Operations,Found Two Leaking Tubes & Eleven Other Tubes W/Pluggable Defects. Caused by Possible Thermal,Hydraulic & Mechanical Loading in Wedge Area & by Possible Residual Caustics Concentratio + (ML17261A158)
- 05000244/LER-1979-025-03, /03L-0:on 791223,containment Entry Was Made But Personnel Air Lock Not Tested Until 791226,exceeding 48-h Tech Spec Requirement.Caused by Existing Procedural Inadequacy + (ML17261A165)
- ML17261A169 + (ML17261A169)
- ML17261A170 + (ML17261A170)
- ML17261A173 + (ML17261A173)
- 05000244/LER-1979-024-01, Samples of Boric Acid Storage Tank Concentrations Found Below Min Limits.Caused by Backflow of Refueling Water Through Boric Acid Tank Outlet Motor Operated Valve + (ML17261A174)
- 05000244/LER-1980-001-03, /03L-0:on 800118,while Performing PT-12.1, Emergency Generator 1A Would Not Accept Nameplate Steady Load Rating.Caused by Adjusting Governor Setting to Incorrect Value Indicated on Dynotape Sticker Setting Mod + (ML17261A175)
- ML17261A176 + (ML17261A176)
- ML17261A178 + (ML17261A178)
- ML17261A179 + (ML17261A179)
- ML17261A180 + (ML17261A180)
- ML17261A181 + (ML17261A181)
- 05000244/LER-1980-002-03, /03L-0:on 800331,during Review of Special Instructions,Discovered That Time from Previous Boron Concentration Sample Exceeded 75 Days.Caused by Inadequate Guidance for Bimonthly Sampling Schedule.Schedule Changed + (ML17261A182)
- 05000244/LER-1980-003-01, /01T-0:on 800414,during Steam Generator Inservice Insp,One Tube in a Steam Generator & 34 Tubes in B Generator Showed Pluggable Indications.Probably Caused by Concentration of Caustics in Crevices + (ML17261A185)
- ML17261A186 + (ML17261A186)
- ML17261A187 + (ML17261A187)
- 05000244/LER-1980-004-01, /01T-0:on 800506,during post-installation Test of Reactor Vessel Head Vent,Dc Power Switches for Both Trains of Low Temp Overpressurization Protection Found in Off Position W/No RCS Vent Open.Cause Unknown + (ML17261A188)
- NL-17-113, Submission of Steam Generator Tube Inspection Report for the 2017 (3R19) Refueling Outage in Accordance with Technical Specification 5.6.8 + (ML17261A189)
- ML17261A190 + (ML17261A190)
- NL-17-116, Annual 10 CFR 50.46 Emergency Core Cooling System Evaluation Changes Report + (ML17261A191)
- 05000334/LER-1917-002, Regarding Inadequate Emergency Diesel Generator (Eog) Tornado Missile Protection Identified Due to Non-conforming Design Conditions + (ML17261A193)
- L-2017-160, Environmental Protection Plan Report Minor Permit Revision Request for Blowdown Sample Panel Discharge Iww Permit No. FL0002208 + (ML17261A195)