- L-91-280, Discusses SE Approving Long Term Hed Program.Attachment 2 Provided List of non-safety Significant Heds That Remained to Be Corrected.Remaining Heds Identified in SE Have No Safety Significance & Will Be Tracked & Resolved + (ML17223B276)
- L-91-237, Application for Amends to Licenses DPR-67 & NPF-16,revising Fire Protection TSs to Delete Sections 3/4.3.3.7,3/4.7.11, 3/4.7.12 & 6.2.2.e & to Delete Section 6.5.1.6.n,per Generic Ltrs 86-10 & 88-12 + (ML17223B277)
- ML17223B278 + (ML17223B278)
- ML17223B279 + (ML17223B279)
- ML17223B280 + (ML17223B280)
- L-91-269, Monthly Operating Repts for Sept 1991 for St Lucie Units 1 & 2 + (ML17223B283)
- 05000335/LER-1991-006-01, :on 910918,generator Output Breaker Closed Out of Phase,Resulting in Instantaneous Overcurrent Condition on Control Element Drive Mechanism Bus.Caused by Personnel Error.Individuals Counseled + (ML17223B285)
- ML17223B286 + (ML17223B286)
- ML17223B287 + (ML17223B287)
- L-91-283, Forwards Addl Info Requested in NRC Re Locations of SG Level Instrument Taps + (ML17223B289)
- ML17223B290 + (ML17223B290)
- 05000389/LER-1991-005-03, :on 910924,discovered That Sept Surveillance for Safety Injection Tank Water Level & Monthly Channel Functional Test Not Performed on Due Date of 910920.Caused by Personnel Error.Test Performed + (ML17223B291)
- L-91-286, Submits Emergency Response Data Sys Implementation Program Plan & Provides Info on Computer Sys Configuration & Interfaces Planned + (ML17223B292)
- ML17223B293 + (ML17223B293)
- ML17223B294 + (ML17223B294)
- L-91-291, Responds to Generic Ltr 91-06, Resolution of Generic Issue A-30, Adequacy of Safety-Related DC Power Supplies + (ML17223B295)
- ML17223B297 + (ML17223B297)
- ML17223B299 + (ML17223B299)
- ML17223B300 + (ML17223B300)
- ML17223B302 + (ML17223B302)
- ML17223B303 + (ML17223B303)
- L-91-297, Advises That No Changes or Errors Discovered in ECCS Limiting Transient Models for Period 901017-911016.ECCS Limiting Transient Supplier for Unit 1 Is Advanced Nuclear Fuels & Unit 2 Is C-E + (ML17223B304)
- L-91-300, Advises of Peak Clad Temp (PCT) Calculated for Cycle 11 Which Has Changed by More than 50 Degrees.Calculated PCT Changed from 2092 Degrees F to 1944 Degrees F.Difference Due to Pellet Clad Gap Width & Lower Initial Fuel Stored Energy + (ML17223B305)
- ML17223B306 + (ML17223B306)
- ML17223B307 + (ML17223B307)
- ML17223B308 + (ML17223B308)
- ML17223B309 + (ML17223B309)
- ML17223B310 + (ML17223B310)
- ML17223B311 + (ML17223B311)
- L-91-308, Monthly Operating Repts for Oct 1991 for St Lucie Units 1 & 2 + (ML17223B313)
- ML17223B314 + (ML17223B314)
- ML17223B316 + (ML17223B316)
- ML17223B317 + (ML17223B317)
- IR 05000335/1991017 + (ML17223B319)
- L-91-310, Special Rept:On 911021 & 22,1B EDG Failed During 24 Hr Surveillance Runs.First Failure Caused by Broken Shaft Due to Fatigue at High Stress Location.New Shaft,Of Modified Design,Installed.Run Performed Satisfactorily on 911027 + (ML17223B320)
- ML17223B321 + (ML17223B321)
- ML17223B323 + (ML17223B323)
- L-91-306, Forwards Summary of Objectives for 1992 Emergency Preparedness Evaluated Exercise on 920212.Exercise Will Involve Participation by Local Personnel & Will Be Evaluated by FEMA + (ML17223B330)
- ML17223B334 + (ML17223B334)
- ML17223B335 + (ML17223B335)
- ML17223B336 + (ML17223B336)
- ML17223B338 + (ML17223B338)
- L-91-311, Forwards Responses to NRC Transmitting Safety Evaluation on Station Blackout Rule (10CFR50.63(a)). Commitment for Required Blackout Duration Revised to Target Reliability Level of Equal to or Greater than 0.975 + (ML17223B340)
- ML17223B341 + (ML17223B341)
- IR 05000335/1991201 + (ML17223B343)
- L-91-319, Responds to NRC Request for Review of AEOD Rept, Experience W/Pump Seals Installed in Reactor Coolant Pumps Mfg by Bryon Jackson + (ML17223B346)
- ML17223B348 + (ML17223B348)
- ML17223B350 + (ML17223B350)
- ML17223B351 + (ML17223B351)
- IR 05000335/1991301 + (ML17223B353)
- 05000335/LER-1991-007-01, :on 911104,diesel Generators Administratively Declared Out of Svc Because of Particulate Contamination in Diesel Fuel Oil.Caused by Deficiency in Plant Chemistry Procedure.Procedures Revised + (ML17223B354)