Browse wiki
Jump to navigation
Jump to search
ML20212H541 +
10 CFR 50 Appendix R +, 10 CFR 50.73 +, 10 CFR 21 +, 10 CFR 50 Appendix A +, 10 CFR 50 +, 10 CFR 50 Appendix B +, 10 CFR 50.59 +, 10 CFR 73 +, 10 CFR 21.6 +, 10 CFR 2.201 +, 10 CFR 2.205 +, 10 CFR 2 Appendix C +, 10 CFR 19.11 +, 10 CFR 50 Appendix B Criterion V +, 10 CFR 50 Appendix B Criterion XVI +, 10 CFR 50 Appendix B Criterion XI +, 10 CFR 50 Appendix B Criterion II +, 10 CFR 50 Appendix B Criterion III, Design Control +, 10 CFR 19.11#a +, 10 CFR 50.55#e + and 10 CFR 50#b +
U-600672, Advises That Control Logic for Operation of Four 36-inch Isolation Valves Does Not Meet NUREG-0737,Item II.E.4.2 Requirement That Reopening of Containment Isolation Valves Require Deliberate Operator Action.Plant Mod Pending +, RA-11 +, U-600544, Responds to Unresolved Item Noted in Insp Rept 50-461/85-65. Corrective Actions:Procedure 1003.01 Revised & Training Program for Independent Technical Reviewers Instituted. Procedure Revs Will Be Completed by 860515 +, U-600583, Forwards Measures Taken to Control Initial Test Program Activities Deferred Past Fuel Load.Appropriate Reviews & Controls Exist to Prevent Performance of Deferred Activities from Adversely Affecting Other Activities +, U-600533, Provides Addl Commitments Re Div II Remote Shutdown Testing to Resolve SER Outstanding Issue 13 as Required by Nrc.Revs to Procedure 4003.01 Being Implemented to Ensure Proper Circuit Alignments During Jumping & Rewiring of Equipment + and U-600207, Forwards Response to Generic Ltr 85-07 Re Implementation of Integrated Schedules for Plant Mods.Integrated Milestone Schedule & Supporting Detail Schedules Presently Address NRC-initiated Mods & util-sponsored Changes +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 +, ML20212H541 + and ML20212H541 +
March 3, 1987 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:00:44, 4 December 2024 +
5 +
Emergency Plan + and SAP-03 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request +
March 3, 1987 +
Secondary containment +, Service water +, Emergency Diesel Generator +, Main Steam Isolation Valve +, Reactor Core Isolation Cooling +, Shutdown Cooling +, HVAC +, High Pressure Core Spray +, Core Spray +, Residual Heat Removal +, Standby Gas Treatment System +, Standby Liquid Control +, Intermediate Range Monitor +, Remote shutdown +, Emergency Core Cooling System +, Safety Relief Valve + and Main Steam +
Notice of Violation from Insp on 860701-1010 & Proposed Imposition of Civil Penalty in Amount of $75,000.Violations Noted:Design Control Measures Did Not Ensure That Design Bases for Structures & Sys Correctly Translated Into Specs +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.