Browse wiki
Jump to navigation
Jump to search
This 4 and 8 hour notification is being ma … This 4 and 8 hour notification is being made to report that Salem Unit 1 has performed an unplanned manual reactor trip and subsequent Auxiliary Feedwater system actuation. The trip was initiated due to loss of Steam Generator water level (SGWL) following the loss of one of the running SGFPs (#11 Steam Generator Feed Pump). The reactor was manually tripped prior to reaching the automatic SGWL low setpoints. #11/12/13 Aux Feedwater Pumps automatically started following the reactor trip on low Steam Generator water level.</br>Salem Unit 1 is currently in Mode 3. Reactor Coolant system pressure is at 2235 PSIG and temperature is 547 degrees Fahrenheit with decay heat removal via the Main Steam Dumps and Auxiliary Feedwater Systems. Unit 1 has no active shutdown technical specification action statements in effect. All control rods inserted on the reactor trip. All ECCS (Emergency Core Cooling System) and ESF (Engineered Safety Feature) systems functioned as expected.</br>There was no major primary or secondary equipment tagged for maintenance prior to this event. No personnel were injured during this event.</br>The licensee will inform the Lower Alloways Creek Township and the NRC Resident Inspector.k Township and the NRC Resident Inspector. +
01:14:00, 9 April 2014 +
50,012 +
23:13:00, 8 April 2014 +
01:14:00, 9 April 2014 +
This 4 and 8 hour notification is being ma … This 4 and 8 hour notification is being made to report that Salem Unit 1 has performed an unplanned manual reactor trip and subsequent Auxiliary Feedwater system actuation. The trip was initiated due to loss of Steam Generator water level (SGWL) following the loss of one of the running SGFPs (#11 Steam Generator Feed Pump). The reactor was manually tripped prior to reaching the automatic SGWL low setpoints. #11/12/13 Aux Feedwater Pumps automatically started following the reactor trip on low Steam Generator water level.</br>Salem Unit 1 is currently in Mode 3. Reactor Coolant system pressure is at 2235 PSIG and temperature is 547 degrees Fahrenheit with decay heat removal via the Main Steam Dumps and Auxiliary Feedwater Systems. Unit 1 has no active shutdown technical specification action statements in effect. All control rods inserted on the reactor trip. All ECCS (Emergency Core Cooling System) and ESF (Engineered Safety Feature) systems functioned as expected.</br>There was no major primary or secondary equipment tagged for maintenance prior to this event. No personnel were injured during this event.</br>The licensee will inform the Lower Alloways Creek Township and the NRC Resident Inspector.k Township and the NRC Resident Inspector. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 8 April 2014 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:51:09, 2 March 2018 +
23:13:00, 8 April 2014 +
true +
true +
-0.0842 d (-2.02 hours, -0.012 weeks, -0.00277 months) +
01:14:00, 9 April 2014 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.