Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML20138E593 | 16 October 1985 | Office of Nuclear Reactor Regulation Harold Denton | Forwards Safety Evaluation Re 830825,0511,22 & 840920 Relief Requests from Preservice Insps Required by ASME Code. Imposition of Identified Preservice Insp Requirements Would Result in Hardship or Unusual Difficulties.Relief Granted | Approval |
B11826, Forwards Rev 0 to Emergency Plan,Responses to Comments Re Draft 3 to Rev 0 of Emergency Plan,List of Offsite Medical Facilities & Revised Table 5.1 Re Station Emergency Organization | 31 October 1985 | Opeka J NORTHEAST UTILITIES Bishop R Northeast Nuclear Energy | Forwards Rev 0 to Emergency Plan,Responses to Comments Re Draft 3 to Rev 0 of Emergency Plan,List of Offsite Medical Facilities & Revised Table 5.1 Re Station Emergency Organization | Request |
ML20136G998 | 31 December 1985 | Opeka J NORTHEAST UTILITIES Northeast Nuclear Energy | Provides Schedule Re Submittal Date of Emergency Diesel Generator Inservice Testing Program & Conformance of safety- Related Generator Auxiliary Sys to Program & ASME Section XI Testing Requirements,Per 851031 Request | Other |
A05104, Discusses plant-specific Analysis & Impact on Compliance w/10CFR50.49 Re Environ Qualification of Electrical Equipment.Addl Info Re GE Drywell Temp Analysis & Tables of Drywell Airspace & Wall Temps Encl.Open Item Resolved | 31 December 1985 | Opeka J NORTHEAST UTILITIES Northeast Nuclear Energy | Discusses plant-specific Analysis & Impact on Compliance w/10CFR50.49 Re Environ Qualification of Electrical Equipment.Addl Info Re GE Drywell Temp Analysis & Tables of Drywell Airspace & Wall Temps Encl.Open Item Resolved | Request |
ML20154J007 | 28 February 1986 | Opeka J NORTHEAST UTILITIES Northeast Nuclear Energy | Forwards Addl Info Re Inservice Insp & Testing Program. Addition of Emergency Diesel Generator Auxiliary Sys Into Inservice Insp & Testing Program Will Be Implemented by 860430.Eight Oversize Drawings Encl | Other |
B11984, Proposed Tech Spec 4.6.E.5,clarifying Functional Testing Requirements for Safety/Relief Valve Position Indication Sys | 28 February 1986 | Northeast Nuclear Energy | Proposed Tech Spec 4.6.E.5,clarifying Functional Testing Requirements for Safety/Relief Valve Position Indication Sys | Request |
ML20199D776 | 17 March 1986 | Thadani A Office of Nuclear Reactor Regulation | Requests Assistance in Conducting Review of Encl Util 860228 Submittal Re Placement of safety-related Emergency Diesel Generator Auxiliary Sys Under Inservice Testing Program.Srp & STS Should Be Used in Determining Acceptance Criteria | Approval |
ML20204A175 | 6 May 1986 | Thadani A Office of Nuclear Reactor Regulation | Grants Relief Requested in from Inservice Testing Requirements of ASME Code,Based on Preliminary Review.Relief Granted Until Detailed Review Completed or Until 6 Months from Ltr Date | Approval |
ML20214M303 | 29 August 1986 | Opeka J NORTHEAST UTILITIES Northeast Nuclear Energy | Forwards Addl Info Re Inservice Testing of Emergency Diesel Generator Auxiliary Sys Revised Relief Request & Pump/Valve Tables,In Support of Review of Inservice Testing Program. Response to NRC 860723 Questions Also Encl | Request |
B12232, Forwards Addl Info Re Inservice Testing of Emergency Diesel Generator Auxiliary Sys Revised Relief Request & Pump/Valve Tables,In Support of Review of Inservice Testing Program. Response to NRC 860723 Questions Also Encl | 29 August 1986 | Opeka J NORTHEAST UTILITIES Northeast Nuclear Energy | Forwards Addl Info Re Inservice Testing of Emergency Diesel Generator Auxiliary Sys Revised Relief Request & Pump/Valve Tables,In Support of Review of Inservice Testing Program. Response to NRC 860723 Questions Also Encl | Request |
A05353, Forwards Revised Relief Request P-5 to Specify Greater Detail Re Inservice Testing of Clean Oil Pumps.Each Pump Will Be Operated Independently During Diesel Generator Testing | 17 September 1986 | Opeka J NORTHEAST UTILITIES Sears C Northeast Nuclear Energy | Forwards Revised Relief Request P-5 to Specify Greater Detail Re Inservice Testing of Clean Oil Pumps.Each Pump Will Be Operated Independently During Diesel Generator Testing | Request |
ML20213G269 | 3 November 1986 | Office of Nuclear Reactor Regulation | Supplemental Safety Evaluation Supporting Util 860228 Request for Relief from ASME Code Requirements for Inservice Testing of Pumps & Valves Associated W/Emergency Diesel Generators | Approval |
ML20213G261 | 3 November 1986 | Thadani A Office of Nuclear Reactor Regulation | Forwards Supplemental Safety Evaluation,Supporting Util 860228 Request for Relief from ASME Code Requirements for Inservice Testing of Pumps & Valves Associated W/Emergency Diesel Generators | Approval |