Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleProject stage
AECM-84-0107, Requests Addl Delay in Submittal of Inservice Insp Program Until 840801.Justification Provided16 March 1984Dale L
MISSISSIPPI POWER & LIGHT CO.
Requests Addl Delay in Submittal of Inservice Insp Program Until 840801.Justification ProvidedOther
AECM-84-0257, Forwards Sample Plan for Selection of Pipe Supports to Be Subj to 10-yr Inservice Insp Plan,Per ASME Boiler & Pressure Vessel Code,Section Xi.Plan Does Not Encompass Snubbers. Review by 840601 Requested11 May 1984Dale L
MISSISSIPPI POWER & LIGHT CO.
Forwards Sample Plan for Selection of Pipe Supports to Be Subj to 10-yr Inservice Insp Plan,Per ASME Boiler & Pressure Vessel Code,Section Xi.Plan Does Not Encompass Snubbers. Review by 840601 RequestedOther
AECM-84-0335, Forwards Requests for Relief from ASME Section XI Code Requirements for Inservice Insp of 11 Items.Requests Submitted in Accordance W/Requirements of 10CFR50.55a(g)(5)(IV)29 June 1984Dale L
MISSISSIPPI POWER & LIGHT CO.
Forwards Requests for Relief from ASME Section XI Code Requirements for Inservice Insp of 11 Items.Requests Submitted in Accordance W/Requirements of 10CFR50.55a(g)(5)(IV)Other
AECM-84-0371, Forwards 10-yr Inservice Insp Plan for Piping,Welds & Supports,Vols I-III25 July 1984Dale L
MISSISSIPPI POWER & LIGHT CO.
Forwards 10-yr Inservice Insp Plan for Piping,Welds & Supports,Vols I-IIIOther
AECM-84-0470, Forwards Request for Relief from ASME Section XI Code Requirements for Inservice & Preservice Insp of Pressure Retaining Piping Weld.Expeditious Review Requested20 September 1984Dale L
MISSISSIPPI POWER & LIGHT CO.
Forwards Request for Relief from ASME Section XI Code Requirements for Inservice & Preservice Insp of Pressure Retaining Piping Weld.Expeditious Review RequestedRequest
ML20134K49122 August 1985Adensam E
Office of Nuclear Reactor Regulation
Forwards Request for Addl Info Re Proposed Inservice Insp Program & Requests for Relief from Requirements in Section XI of ASME Code Submitted on 840920.Info Needed by 850930RAI
AECM-85-0349, Forwards Response to 850822 Request for Addl Info Re 840725 10-yr Inservice Insp Program & 840920 Request for Exemption from Certain ASME Code Section XI Requirements.Program Approval Requested by 86030231 October 1985Dale L
MISSISSIPPI POWER & LIGHT CO.
Forwards Response to 850822 Request for Addl Info Re 840725 10-yr Inservice Insp Program & 840920 Request for Exemption from Certain ASME Code Section XI Requirements.Program Approval Requested by 860302Request
ML20202J45528 March 1986SCIENCE APPLICATIONS INTERNATIONAL CORP. (FORMERLYFirst Interval Inservice Insp Program,Grand Gulf Nuclear Station, Technical Evaluation ReptOther
AECM-86-0186, Requests Response to Encl Rev to Justification for Relief Request I-00008 Re ASME Section XI Code Requirements for Inservice Insp of CRD & in-core Housing Welds & Flange Bolting,Per ,By 86080114 July 1986Kingsley O
MISSISSIPPI POWER & LIGHT CO.
Requests Response to Encl Rev to Justification for Relief Request I-00008 Re ASME Section XI Code Requirements for Inservice Insp of CRD & in-core Housing Welds & Flange Bolting,Per ,By 860801Request
ML20203G42522 July 1986Butler W
Office of Nuclear Reactor Regulation
Forwards Safety Evaluation Re Inservice Insp Program & Requests for Relief from Certain Inservice Insp Requirements & SAIC-86/1626, First Interval Inservice Insp Program, Technical Evaluation Rept.Plan & Requests AcceptableApproval
ML20203G43622 July 1986Office of Nuclear Reactor RegulationSafety Evaluation Re Inservice Insp Program & Requests for Relief from Certain Inservice Insp Requirements.Inservice Insp Plan Acceptable for ImplementationApproval
AECM-86-0224, Requests NRC Approval of Proposed Change to Inservice Insp Program to Allow Use of Figure Iwb 2500-7(b) from 1983 Edition,Summer 1983 Addenda of ASME Code,Section XI Re Exam Category B-D Weldments.Fee Paid23 July 1986Kingsley O
MISSISSIPPI POWER & LIGHT CO.
Requests NRC Approval of Proposed Change to Inservice Insp Program to Allow Use of Figure Iwb 2500-7(b) from 1983 Edition,Summer 1983 Addenda of ASME Code,Section XI Re Exam Category B-D Weldments.Fee PaidRequest
ML20203J81130 July 1986Office of Nuclear Reactor Regulation
Kintner L
Notifies That 860723 Request to Use Portion of 1983 ASME Boiler & Pressure Vessel Code,Section XI in Plant Inservice Insp Program Should Be Resubmitted,As Request for Relief from 1977 Edition of Code,By 860816Other
AECM-86-0248, Forwards Relief Request I-00013 Seeking NRC Approval for Use of Summer 1983 Addenda of ASME Section Xi,Based on Interpretation of 10CFR50.55(a)(g)(4)(iv), Re Inservice Insp Requirements for Reactor Pressure Vessel Nozzles15 August 1986Kingsley O
MISSISSIPPI POWER & LIGHT CO.
Forwards Relief Request I-00013 Seeking NRC Approval for Use of Summer 1983 Addenda of ASME Section Xi,Based on Interpretation of 10CFR50.55(a)(g)(4)(iv), Re Inservice Insp Requirements for Reactor Pressure Vessel NozzlesRequest
AECM-86-0252, Forwards Fee for 860714 Application Revising Relief Request I-00008,per NRC 860804 Request20 August 1986Kingsley O
MISSISSIPPI POWER & LIGHT CO.
Forwards Fee for 860714 Application Revising Relief Request I-00008,per NRC 860804 RequestRequest
ML20215E7636 October 1986Butler W
Office of Nuclear Reactor Regulation
Forwards Safety Evaluation Supporting Inservice Insp Relief Requests I-00008 & I-00013 Which Request Relief from ASME Code Section XI Requirements for Inservice Control Rod Drive Insp & Approval of 1983 ASME Code Re Inservice Insp ProgramApproval
ML20215E7776 October 1986Office of Nuclear Reactor RegulationSafety Evaluation Re Inservice Insp Program & Requests for Relief from Certain Inservice Insp RequirementsApproval
AECM-87-0068, Documents Conversations Re Postulated Complete through-wall Circumferential Fracture of CRD Housing & Normal Makeup Capacity Available at or Near Cold Shutdown.Crd Pump Can Supply Normal Makeup Inventory Due to Failure.Fee Paid23 July 1987Kingsley O
INC.
SYSTEM ENERGY RESOURCES
Documents Conversations Re Postulated Complete through-wall Circumferential Fracture of CRD Housing & Normal Makeup Capacity Available at or Near Cold Shutdown.Crd Pump Can Supply Normal Makeup Inventory Due to Failure.Fee PaidOther