ML20199E54331 January 1998Rev 3 to WCAP-14720, Vogtle Units 1 & 2 Spent Fuel Rack Criticality Analysis W/Credit for Soluble BoronShutdown Margin
ML20217H91231 August 1997Rev 2 to Vogtle Units 1 & 2 Spent Fuel Rack Criticality Analysis W/Credit for Soluble BoronShutdown Margin
ML20128H02031 August 1996Spent Fuel Rack Criticality Analysis W/Credit for Soluble Boron
ML20065G44028 February 1994Analysis of Capsule Y from Georgia Power Co Vogtle Unit 1 Reactor Vessel Radiation Surveillance Program
ML20065G42528 February 1994Evaluation of PTS for Vogtle Unit 1 Reactor Vessel
ML20101M54130 April 1992Gap Aw Vogtle Unit 2 Reactor Vessel Radiation Surveillance Program
ML20101M53128 February 1992Gap Aw Vogtle Unit 1 Reactor Vessel Radiation Surveillance Program
ML20091F21730 September 1991RHR Sys Autoclosure Interlock Removal Rept for Vogtle Electric Generating Plant,Units 1 & 2 Georgia Power Co. W/Ten Oversize DrawingsBoric Acid
ML20082M58231 August 1991Analysis of Capsule U from Vogtle Electric Generating Plant Unit 2 Reactor Vessel Radiation Surveillance Program
ML20070S34431 March 1991Nonproprietary Rev 1 to WCAP-12789, RTD Bypass Elimination Licensing Rept for Vogtle Electric Generating PlantHydrostatic
Scaffolding
Flow Induced Vibration
ML20012D38131 March 1990Nonproprietary Suppl 2 to WCAP-12219, Supplementary Assessment of Leak-Before-Break for Pressurizer Surge Lines of Vogtle Units 1 & 2.Safe Shutdown Earthquake
ML20005E82631 December 1989Suppl 1 to Supplementary Analysis to Address Thermal Stratification for Vogtle Unit 1 Pressurizer Surge Line.
ML20070H30531 December 1989Nonproprietary Westinghouse Revised Thermal Design Procedure Instrument Uncertainty Methodology for Vogtle 1 & 2 Nuclear Power Station (for RTD Bypass Loop Elimination)
ML20070H30131 December 1989Nonproprietary Westinghouse Revised Thermal Design Procedure Instrument Uncertainty Methodology for Vogtle 1 & 2 Nuclear Power Station (for RTD Bypass Loops)
ML20247E66731 March 1989Evaluation of Thermal Stratification for Vogtle Unit 2 Pressurizer Surge LineSafe Shutdown Earthquake
Finite Element Analysis
ML20235G94531 January 1989Surge Line Stratification Presentation Overheads - Georgia Power/Nrc Meeting 890125Safe Shutdown Earthquake
ML20154J98330 April 1988RCS Flow Anomaly Investigation Rept
ML20147D32831 January 1988LOFTTR2 Analysis for Steam Generator Tube Rupture Event. Related Info Encl
ML20236X83531 October 1987Nonproprietary Rev 0 to WCAP-11665, Westinghouse NSSS Mechanical Equipment Qualification for Georgia Power Co Plant Vogtle-Unit 1Safe Shutdown
Hydrostatic
ML20236C79131 October 1987Nonproprietary Technical Bases for Eliminating RHR Line Rupture from Structural Design Basis for Vogtle Unit 2Finite Element Analysis
Pressure Boundary Leakage
ML20236B41231 October 1987Technical Bases for Eliminating Accumulator Line Rupture as Structural Design Basis for Vogtle Unit 2Finite Element Analysis
Pressure Boundary Leakage
ML20234E99930 September 1987Nonproprietary Version of Addl Info in Support of Elimination of Postulated Pipe Ruptures in Pressurizer Surge Line of Vogtle Unit 2Safe Shutdown Earthquake
ML20237J87131 August 1987Nonproprietary Addendum 1 to Addl Info in Support of Elimination of Postulated Pipe Ruptures in Pressurizer Surge Line of Vogtle Unit 2Pressure Boundary Leakage
ML20235X04131 July 1987Nonproprietary Technical Bases for Eliminating Pressurizer Surge Line Rupture as Structural Design Basis for Vogtle Unit 2Finite Element Analysis
ML20207K94730 November 1986Nonproprietary Rev 1 to Westinghouse Setpoint Methodology for Protection Sys,Vogtle StationAnticipated operational occurrence
ML20215L30030 September 1986Nonproprietary, Main Steam Line Break Info Used for Superheat Study for Vogtle Units 1 & 2
ML20235R4385 September 1986Rev 0 to Design Rept Summary of High Density Spent Fuel Storage Racks for Georgia Power Co Aw Vogtle Unit 1Safe Shutdown Earthquake
Earthquake
Fuel cladding
ML20203N49331 August 1986Westinghouse Setpoint Methodology for Protection Sys - Vogtle StationAnticipated operational occurrence
ML20112F04728 February 1985Rev 1 Tdi Diesel Generator Design Review & Quality Revalidation ReptSafe Shutdown
Liquid penetrant
ML20090K67331 May 1984Nonproprietary Version of Technical Bases for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Aw Vogtle Units 1 & 2Safe Shutdown Earthquake
Pressure boundary leak
ML20084P54629 February 1984Cold Overpressure Mitigating SysBoric Acid
Shutdown Margin
Loop seal
Stroke time