 Issue dateTitleTopic
U-603232, Special Rept:On 990531 Lpms Was Declared Inoperable Due to Receipt of High Vibration & Loose Parts Alarm Which Did Not Clear.Lpms Was Restored to Operable Status on 990707 After Alignment & Tension on Recorder Tape Drive Was Adjusted9 July 1999Special Rept:On 990531 Lpms Was Declared Inoperable Due to Receipt of High Vibration & Loose Parts Alarm Which Did Not Clear.Lpms Was Restored to Operable Status on 990707 After Alignment & Tension on Recorder Tape Drive Was Adjusted
U-603101, Special Rept:On 980918,discovered That Triaxial Seismic Accelerometers Had Not Been Properly Calibrated.Caused by Inadequate Calibration Procedure.Calibration to Be Performed off-site28 October 1998Special Rept:On 980918,discovered That Triaxial Seismic Accelerometers Had Not Been Properly Calibrated.Caused by Inadequate Calibration Procedure.Calibration to Be Performed off-siteOffsite Dose Calculation Manual
Safe Shutdown Earthquake
Operating Basis Earthquake
U-603014, Special Rept:On 980512,lightning Struck Primary Meteorological Monitoring Instrumentation Tower Damaging 60- Meter Wind Speed & Associated Transmuter Circuit Card. Surveillance Testing Performed28 May 1998Special Rept:On 980512,lightning Struck Primary Meteorological Monitoring Instrumentation Tower Damaging 60- Meter Wind Speed & Associated Transmuter Circuit Card. Surveillance Testing Performed
U-602940, Ro:On 980213,alert Emergency Classification Was Declared IAW EPIP EC-02, Emergency Classifications. Caused by Tripped Inverter.Rhr a Was Restored at Approx 0945 H & Emergency Terminated at 1004 H Per EPIP EC-04, Alert20 February 1998Ro:On 980213,alert Emergency Classification Was Declared IAW EPIP EC-02, Emergency Classifications. Caused by Tripped Inverter.Rhr a Was Restored at Approx 0945 H & Emergency Terminated at 1004 H Per EPIP EC-04, Alert
U-602921, Special Rept:On 980113,operations Personnel Declared Meteorological Tower Wind Direction Instrumentation Inoperable.Consistent Difference Suspected to Have Been Caused by Rotation of Either or Both of Wind Sensor29 January 1998Special Rept:On 980113,operations Personnel Declared Meteorological Tower Wind Direction Instrumentation Inoperable.Consistent Difference Suspected to Have Been Caused by Rotation of Either or Both of Wind SensorHigh winds
U-602599, Special Rept:On 960516,Loose Parts Monitoring System Declared Inoperable.Caused by Intermittent Alarms.Removed Temporary Mod & Restored Alarm Feature for Channel Three21 June 1996Special Rept:On 960516,Loose Parts Monitoring System Declared Inoperable.Caused by Intermittent Alarms.Removed Temporary Mod & Restored Alarm Feature for Channel ThreeTemporary Modification
U-602534, Special Rept:On 951206,determined Facility May Have Been Operated Above Max Power Level Authorized by License Due to Error in Reactor Heat Balance.Util Will Bias CRD Sys Flow Process Computer Point3 January 1996Special Rept:On 951206,determined Facility May Have Been Operated Above Max Power Level Authorized by License Due to Error in Reactor Heat Balance.Util Will Bias CRD Sys Flow Process Computer PointFuel cladding
U-602527, Special Rept:On 951103,reactor Water Cleanup Sys Flow Rate Computer Valve Substituted W/Value of Zero & Sys Actually Operating.Caused by Lack of Attention.Shift Technical Advisor Immediately Restored Computer5 December 1995Special Rept:On 951103,reactor Water Cleanup Sys Flow Rate Computer Valve Substituted W/Value of Zero & Sys Actually Operating.Caused by Lack of Attention.Shift Technical Advisor Immediately Restored Computer
U-602426, Ro:On 950301,plant Was Operating at Approx 75% Fire Was Reported in a turbine-driven Reactor Feed Pump Room3 March 1995Ro:On 950301,plant Was Operating at Approx 75% Fire Was Reported in a turbine-driven Reactor Feed Pump Room
U-602421, Ro:On 950216,Div 2 125 Volt Dc Electrical Power Sys Declared Inoperable.Caused by Failure of Silicon Controlled Rectifier Firing Board in Div 2 Battery Charger.Battery Charger Repaired22 February 1995Ro:On 950216,Div 2 125 Volt Dc Electrical Power Sys Declared Inoperable.Caused by Failure of Silicon Controlled Rectifier Firing Board in Div 2 Battery Charger.Battery Charger RepairedEnforcement Discretion
U-602348, Special Rept:On 940906,CPS Declared Loose Parts Monitoring Sys Out of Svc.Caused by False Alarms.Util Will Recalibrate Channel Six10 October 1994Special Rept:On 940906,CPS Declared Loose Parts Monitoring Sys Out of Svc.Caused by False Alarms.Util Will Recalibrate Channel SixTemporary Modification
U-602311, Special Rept:On 940624,inoperabilities of Meteorological Monitoring Instrumentation Channels for More than 7 Days Identified.Personnel Worked Expeditiously to Return Meteorological Instrumentation to Operable Status12 July 1994Special Rept:On 940624,inoperabilities of Meteorological Monitoring Instrumentation Channels for More than 7 Days Identified.Personnel Worked Expeditiously to Return Meteorological Instrumentation to Operable Status
U-602308, Special Rept:On 940607,determined Valid Failure of Div 1 EDG Had Occurred Due to Excessive Current.Replaced Failed Relay7 July 1994Special Rept:On 940607,determined Valid Failure of Div 1 EDG Had Occurred Due to Excessive Current.Replaced Failed RelaySafe Shutdown
High winds
Offsite Circuit
U-602193, Special Rept:On 930927,valid Failure of Div II DG Occurred During Surveillance Testing.Caused by Insufficient Contact Pressure Between Contacting Surfaces.Contact Pressure Checks to Improve Component Reliability Implemented12 October 1993Special Rept:On 930927,valid Failure of Div II DG Occurred During Surveillance Testing.Caused by Insufficient Contact Pressure Between Contacting Surfaces.Contact Pressure Checks to Improve Component Reliability Implemented
U-602189, Follow-up Special Rept on Progress of Investigation Into Diesel I DG Test Failures That Occurred on 930623,0721 & 0803.Current Number of Valid Failures in Last 100 Valid Tests of DG1A Is Seven.Testing for DG1A Conducted24 September 1993Follow-up Special Rept on Progress of Investigation Into Diesel I DG Test Failures That Occurred on 930623,0721 & 0803.Current Number of Valid Failures in Last 100 Valid Tests of DG1A Is Seven.Testing for DG1A ConductedSafe Shutdown
High winds
Offsite Circuit
U-602181, Special Rept:On 930812-30,differential Air Temp Instrumentation Inoperable.Caused by Problem W/Power Supply Panel 0EM01J.Replacement Power Supply Unavailable. Engineering Change Request ECN 28103 Processed30 August 1993Special Rept:On 930812-30,differential Air Temp Instrumentation Inoperable.Caused by Problem W/Power Supply Panel 0EM01J.Replacement Power Supply Unavailable. Engineering Change Request ECN 28103 Processed
U-602174, Special Rept:On 930721 & 0803,valid Test Failures of Div I DG Occurred Due to Problem W/Contacts within Breaker Control Switch & Failed Coil in B-C Phase Undervoltage Relay, Respectively.Subj Parts Will Be Replaced During DG Outage20 August 1993Special Rept:On 930721 & 0803,valid Test Failures of Div I DG Occurred Due to Problem W/Contacts within Breaker Control Switch & Failed Coil in B-C Phase Undervoltage Relay, Respectively.Subj Parts Will Be Replaced During DG Outage
U-602163, Special Rept:On 930623,Div I DG (DG1A) Failed to Synchronize W/Associated Safety Bus & Generator Output Breaker Tripped on Reverse Power Signal Due to Faulty Reverse Power Relay. DG1A Reverse Power Relay Replaced W/Newer Model23 July 1993Special Rept:On 930623,Div I DG (DG1A) Failed to Synchronize W/Associated Safety Bus & Generator Output Breaker Tripped on Reverse Power Signal Due to Faulty Reverse Power Relay. DG1A Reverse Power Relay Replaced W/Newer ModelCommercial Grade Dedication
U-602068, Ro:On 921107,ORIX-PR008 Was Declared Inoperable Due to Lo Fail Signal Received for Channel 3 Which Was Unable to Be Reset.Preplanned Alternate Method of Monitoring HVAC Stack Initiated24 November 1992Ro:On 921107,ORIX-PR008 Was Declared Inoperable Due to Lo Fail Signal Received for Channel 3 Which Was Unable to Be Reset.Preplanned Alternate Method of Monitoring HVAC Stack Initiated
U-602057, Special Rept:On 920921,generator Output Breaker Failed to Close on Four Attempts.Caused by Bent Protective Cover Over Auxiliary Switches & anti-pump Coil.Output Breaker Racked to Test Position & Sucessfully Cycled Three Times20 October 1992Special Rept:On 920921,generator Output Breaker Failed to Close on Four Attempts.Caused by Bent Protective Cover Over Auxiliary Switches & anti-pump Coil.Output Breaker Racked to Test Position & Sucessfully Cycled Three Times
U-602049, Ro:On 920922,Control Room Received Notification That Employee Working in Radwaste Sort Tent Had Been Injured & Potentially Contaminated.Ambulance Called to Respond.Hosp Notified Util That Victim Was Not Contaminated28 September 1992Ro:On 920922,Control Room Received Notification That Employee Working in Radwaste Sort Tent Had Been Injured & Potentially Contaminated.Ambulance Called to Respond.Hosp Notified Util That Victim Was Not Contaminated
U-602035, Special Rept:On 920717 & 0807,output Breaker Failed to Close During Periodic Testing of Dg.Caused by Failure of H1 trunk-operated Contact Switch Due to Slight Breaker Movement.Vendor Manual for Switchgear Will Be Reviewed19 August 1992Special Rept:On 920717 & 0807,output Breaker Failed to Close During Periodic Testing of Dg.Caused by Failure of H1 trunk-operated Contact Switch Due to Slight Breaker Movement.Vendor Manual for Switchgear Will Be ReviewedSafe Shutdown
ML20216J2868 August 1992Special Rept:On 920712,determined That Valid Failure of Div 1 EDG Occurred.Caused by B-C Phase CV-2 Relay Telephone Coil Failing Due to Excessive Current.Design Change Mod Initiated.Also Reportable Per Part 21Safe Shutdown
High winds
Enforcement Discretion
Offsite Circuit
U-601991, Ro:On 920522,discovered That External Vessel Surface Was Hot & Chart Recorder Indicated Absorber Bed Temp Greater than 300F.Fire Brigade Was Activated.Sampling Process Established to Monitor Purge Exhaust Composition1 June 1992Ro:On 920522,discovered That External Vessel Surface Was Hot & Chart Recorder Indicated Absorber Bed Temp Greater than 300F.Fire Brigade Was Activated.Sampling Process Established to Monitor Purge Exhaust Composition
U-601970, Special Rept:On 920328,diesel Generator 1B Manually Started But Stabilized Outside TS Range of 60 + or - Hz. Caused by Failure of Power Supply for Electronic Speed Controller.Power Supply Replaced24 April 1992Special Rept:On 920328,diesel Generator 1B Manually Started But Stabilized Outside TS Range of 60 + or - Hz. Caused by Failure of Power Supply for Electronic Speed Controller.Power Supply Replaced
U-601946, Special Rept:On 920302,meteorological Tower Differential Air Temp Instrumentation Declared Inoperable to Facilitate Troubleshooting Re Discrepancy in Meteorological Data. Missing Ducting Tube from Aspirator Installed6 March 1992Special Rept:On 920302,meteorological Tower Differential Air Temp Instrumentation Declared Inoperable to Facilitate Troubleshooting Re Discrepancy in Meteorological Data. Missing Ducting Tube from Aspirator Installed
U-601942, Revised Special Rept Re non-valid Test Failure of Div I DG, Describing Correct Steps Involved in Synchronizing DG W/ Offsite Power.Dg Output Voltage Adjusted Such That It Is Slightly Higher than Offsite Power Voltage2 March 1992Revised Special Rept Re non-valid Test Failure of Div I DG, Describing Correct Steps Involved in Synchronizing DG W/ Offsite Power.Dg Output Voltage Adjusted Such That It Is Slightly Higher than Offsite Power Voltage
U-601931, Special Rept:On 920109,diesel Generator 1A Tripped Due to Reverse Power.Caused by Improper Manual Loading Following Synchronization W/Offsite Power.Dg 1A Manually Started to Demonstrate Operability Per Surveillance Procedure 9080.015 February 1992Special Rept:On 920109,diesel Generator 1A Tripped Due to Reverse Power.Caused by Improper Manual Loading Following Synchronization W/Offsite Power.Dg 1A Manually Started to Demonstrate Operability Per Surveillance Procedure 9080.01
U-601893, Special Rept:On 911001,ORIX-PRO12 Declared Inoperable in Order to Perform Channel Calibr in Accordance W/Ts Surveillance Requirement 4.3.7.5.Calibr Initially Performed by day-shift C&I Crew,Then Backshift Crew17 October 1991Special Rept:On 911001,ORIX-PRO12 Declared Inoperable in Order to Perform Channel Calibr in Accordance W/Ts Surveillance Requirement 4.3.7.5.Calibr Initially Performed by day-shift C&I Crew,Then Backshift Crew
U-601834, Special Rept:On 910404,during Surveillance Diesel Generator 1A Reached Required Voltage & Frequency But Failed to Close & Phase Undervoltage Relay B-C Tripped.Cause Not Determined.Racking Mechanism Will Be Inspected & Lubricated6 May 1991Special Rept:On 910404,during Surveillance Diesel Generator 1A Reached Required Voltage & Frequency But Failed to Close & Phase Undervoltage Relay B-C Tripped.Cause Not Determined.Racking Mechanism Will Be Inspected & Lubricated
U-601788, Special Rept:On 910106,Div II Diesel Generator Failed During Test.Caused by Malfunction of A-3 Relay Tachometer. Preventive Maint Task Will Be Issued to Remove,Inspect & Bench Test A-3 Relay Every Two Yrs5 February 1991Special Rept:On 910106,Div II Diesel Generator Failed During Test.Caused by Malfunction of A-3 Relay Tachometer. Preventive Maint Task Will Be Issued to Remove,Inspect & Bench Test A-3 Relay Every Two Yrs
U-601309, Ro:On 881111,generator Trip W/Reactor Scram Occurred Due to Sudden Pressure Actuation on 1C Main Power Transformer & Fire on Insulator of 1C Main Power Transformer Discovered. Fire Extinguished12 November 1988Ro:On 881111,generator Trip W/Reactor Scram Occurred Due to Sudden Pressure Actuation on 1C Main Power Transformer & Fire on Insulator of 1C Main Power Transformer Discovered. Fire Extinguished
U-601298, Ro:On 881026,Tech Spec 3.0.3 Entered Due to Declaring Control Room Ventilation Train a Inoperable.Caused by Faulty Flow Transmitter.Reactor Power Was Reduced & Calibr on Train a Flow Transmitter Performed27 October 1988Ro:On 881026,Tech Spec 3.0.3 Entered Due to Declaring Control Room Ventilation Train a Inoperable.Caused by Faulty Flow Transmitter.Reactor Power Was Reduced & Calibr on Train a Flow Transmitter Performed
U-601265, Ro:On 880901,HPCS Initiated & Injected Water Into Reactor for 28 During Maint Surveillance Activities on Reactor Water Level Transmitter.Injection Valve & HPCS Pump Secured. Notification of Unusual Event Lasted Approx 10 Minutes2 September 1988Ro:On 880901,HPCS Initiated & Injected Water Into Reactor for 28 During Maint Surveillance Activities on Reactor Water Level Transmitter.Injection Valve & HPCS Pump Secured. Notification of Unusual Event Lasted Approx 10 Minutes
U-601258, Special Rept:On 880803,accident Monitoring Instrumentation for HVAC Stack Declared Inoperable for More That 72 H.Caused by Underway Work to Perform Routine Channel Calibr.Plant Condition Rept Initiated22 August 1988Special Rept:On 880803,accident Monitoring Instrumentation for HVAC Stack Declared Inoperable for More That 72 H.Caused by Underway Work to Perform Routine Channel Calibr.Plant Condition Rept Initiated
U-601219, Ro:On 880623,maint Technician Badly Burned in 762-ft Radwaste Evaporator Vapor Body Room.Caused by Performing Work on Wrong Evaporator.Evaporator Secured & Technician Given Medical Attention24 June 1988Ro:On 880623,maint Technician Badly Burned in 762-ft Radwaste Evaporator Vapor Body Room.Caused by Performing Work on Wrong Evaporator.Evaporator Secured & Technician Given Medical Attention
U-601173, Special Rept:On 880329,discovered Failure of Wind Velocity & Direction Sensors on Facility Meteorological Tower.Caused by Inadvertent Exposure of Sensors to Weather.Sensor Assembly, Including Retaining Device Replaced15 April 1988Special Rept:On 880329,discovered Failure of Wind Velocity & Direction Sensors on Facility Meteorological Tower.Caused by Inadvertent Exposure of Sensors to Weather.Sensor Assembly, Including Retaining Device ReplacedHigh winds
U-601026, Summary Rept:On 870828,notification of Unusual Event Declared Per Emergency Plan Implementing Procedures EC-02. Personnel Informed of Bomb Threat Made Against Util.Security Levels Tightened & Searches Performed.No Explosives Found31 August 1987Summary Rept:On 870828,notification of Unusual Event Declared Per Emergency Plan Implementing Procedures EC-02. Personnel Informed of Bomb Threat Made Against Util.Security Levels Tightened & Searches Performed.No Explosives Found
U-601015, Ro:On 870816,protected Area Intrusion Detection Sys Deactivated Due to Severe Weather.Compensatory Measures in Place.Security Personnel Removed from Post booths.Closed- Circuit Television Observers Posted Until Weather Cleared21 August 1987Ro:On 870816,protected Area Intrusion Detection Sys Deactivated Due to Severe Weather.Compensatory Measures in Place.Security Personnel Removed from Post booths.Closed- Circuit Television Observers Posted Until Weather Cleared
U-601017, Ro:On 870819,bomb Threat Received.Security Levels Tightened. State of Il,Nrc Incident Response Ctr & NRC Resident Inspector Notified.No Explosives Located20 August 1987Ro:On 870819,bomb Threat Received.Security Levels Tightened. State of Il,Nrc Incident Response Ctr & NRC Resident Inspector Notified.No Explosives LocatedStolen
U-601004, Ro:On 870804,notification of Unusual Event Declared Due to Inoperability of Channel 1B21-N697A,LPCS,LPCI & RHR B. Functional Test of Channel Performed & Device,Lpcs & LPCI Declared Operable.Notification of Unusual Event Terminated5 August 1987Ro:On 870804,notification of Unusual Event Declared Due to Inoperability of Channel 1B21-N697A,LPCS,LPCI & RHR B. Functional Test of Channel Performed & Device,Lpcs & LPCI Declared Operable.Notification of Unusual Event Terminated
ML20236B58817 July 1987Special Rept:On 870610,loose Parts Monitoring Sys Channels Went Into Alarm & Could Not Be Reset.Caused by Flow Noise from Reactor Recirculation Sys Flow Control Valve in Throttled Position.Alarm Temporarily DisabledTemporary Modification
U-600977, Ro:On 870704,protected Area Intrusion Detection Sys Deactivated Due to Severe Weather.Compensatory Measures Not Taken Due to Personnel Safety.Util Will Review Area of Formal Communications & Take Corrective Actions11 July 1987Ro:On 870704,protected Area Intrusion Detection Sys Deactivated Due to Severe Weather.Compensatory Measures Not Taken Due to Personnel Safety.Util Will Review Area of Formal Communications & Take Corrective Actions
U-600970, Special Rept:On 870608,plant Failed to Reach Rated Voltage & Rated Speed in Equal to or Less than 12 S.Caused by Linkage Connecting Shaft to Fuel Rack Out of Alignment.Alignment Requirements & Linkage Reworked8 July 1987Special Rept:On 870608,plant Failed to Reach Rated Voltage & Rated Speed in Equal to or Less than 12 S.Caused by Linkage Connecting Shaft to Fuel Rack Out of Alignment.Alignment Requirements & Linkage Reworked
U-600964, Special Rept:On 870610,earthquake Estimated to Be 5.0 on Richter Scale Noted.Walkdowns of Plant Structures & Sys Conducted.No Damage or Abnormal Conditions Observed.Related Info,Including Sargent & Lundy ...Seismic...Rept, Encl19 June 1987Special Rept:On 870610,earthquake Estimated to Be 5.0 on Richter Scale Noted.Walkdowns of Plant Structures & Sys Conducted.No Damage or Abnormal Conditions Observed.Related Info,Including Sargent & Lundy ...Seismic...Rept, EnclEarthquake
U-600956, Final Status of Repair & Anticipated Schedule for Restoration of Remaining Out of Svc Annunciators.One Annunciator Listed in Groups 1 & 2 of Util Remain to Be Repaired11 June 1987Final Status of Repair & Anticipated Schedule for Restoration of Remaining Out of Svc Annunciators.One Annunciator Listed in Groups 1 & 2 of Util Remain to Be Repaired
U-600947, Notification of Unusual Event:On 870524,motor-driven Feed Pump Regulating Valve 1FW-F004 Malfunctioned,Increasing Reactor Water Level.Cause Under Investigation.Valve Shifted to Manual Control W/No Response.Event Terminated Same Day26 May 1987Notification of Unusual Event:On 870524,motor-driven Feed Pump Regulating Valve 1FW-F004 Malfunctioned,Increasing Reactor Water Level.Cause Under Investigation.Valve Shifted to Manual Control W/No Response.Event Terminated Same Day
U-600941, Special Rept:On 870411,operator Discovered No Power to Play Back Pens (All Lights Out) of Playback Unit.Caused by Blown Fuses of Recorder,Playback & Analyzer.Sensor & Portion of Circuit Boards Have Been Replaced21 May 1987Special Rept:On 870411,operator Discovered No Power to Play Back Pens (All Lights Out) of Playback Unit.Caused by Blown Fuses of Recorder,Playback & Analyzer.Sensor & Portion of Circuit Boards Have Been Replaced
U-600928, Ro:On 870506,reactor Manually Scrammed When Reactor Pressure Vessel Level Began to Rise.Caused by Failure of Feedwater Valve Controlling Flow of Water to Reactor to Open.Reactor Shut Down.State of Il & NRC Response Ctr Notified6 May 1987Ro:On 870506,reactor Manually Scrammed When Reactor Pressure Vessel Level Began to Rise.Caused by Failure of Feedwater Valve Controlling Flow of Water to Reactor to Open.Reactor Shut Down.State of Il & NRC Response Ctr Notified
U-600890, Ro:On 870322,containment Isolation Occurred on Instrument Air Sys During Surveillance of ECCS Reactor Water Level Channel Functional Checklist.Cause Not Stated.Reactor Shut Down23 March 1987Ro:On 870322,containment Isolation Occurred on Instrument Air Sys During Surveillance of ECCS Reactor Water Level Channel Functional Checklist.Cause Not Stated.Reactor Shut Down