 Issue dateTitleTopic
ML17264A93810 July 1997Deficiency Rept Re Potential Safety Hazard Associated w/FM-Alco 251 Engin,High Pressure Fuel tube-catalog: 4401031-2 in Which Dual Failure Mode Exists.Caused by Incorrect Forming Process
ML20094M62521 November 1995Final Part 21 Rept of Investigation & Analysis of Suspect Fasteners Event 29257.B&G-Cardinal Discontinued Using Heat Treatment Equipment at Cardinal Facility Until Such Time That Satisfactory Mods Made to Hardware & Procedures
ML20126J59631 December 1992Part 21 Rept Re Potential Loss of RHR Cooling During Nozzle Dam Removal.Nozzle Dams May Create Trapped Air Column Behind Cold Leg Nozzle Dam.Mod to Nozzle Dams Currently Underway. Ltrs to Affected Utils EnclHydrostatic
ML20214M3184 September 1986Potential Part 21 Rept Re Contromatics Actuator W/Jackscrew/ Handwheel Emergency Override Operator.Jackscrew/Handwheel Should Be Used for Emergency Manual Operation Only.Encl Ltr Also Sent to Listed Utils/Ae Firms
DCL-85-282, Potential Part 21 Problem Re Pipe Clamps Mfg by Natl Valve & Mfg Co Reported to NRC on 850620 by Pacific Scientific Co. Facility Unaffected.No Class 1 Pipe Clamps Mfg by Natl Valve & Mfg Co Used29 August 1985Potential Part 21 Problem Re Pipe Clamps Mfg by Natl Valve & Mfg Co Reported to NRC on 850620 by Pacific Scientific Co. Facility Unaffected.No Class 1 Pipe Clamps Mfg by Natl Valve & Mfg Co Used
DCL-85-074, Final Deficiency Rept Re Cracks in Welds on Pipe Rupture Restraints Made by Pullman Power Products.Unacceptable Welds Repaired or Modified22 February 1985Final Deficiency Rept Re Cracks in Welds on Pipe Rupture Restraints Made by Pullman Power Products.Unacceptable Welds Repaired or Modified
ML20092K11925 June 1984Part 21 Rept Adivising of Util Search of Records to Determine If Bahnson Co of Winston-Salem,NC Svcs Used by Util,Per Re Bahnson Co HVAC Equipment
ML20092D97115 June 1984Part 21 Rept Re Thermal Nonrepeatability & Other Calibr Errors in Barton Lot 1 Transmitters.Initially Reported on 840615.Transmitter Defects Identified & Expected Error Deviations Calculated.Utils Notified
DCL-84-086, Final Deficiency Rept Re Malfunction of Valve Operator Mfg by Limitorque.Initially Reported on 830627.Existing Screws Will Be Replaced on Affected Valves Prior to Fuel Load.Maint Procedures Modified1 March 1984Final Deficiency Rept Re Malfunction of Valve Operator Mfg by Limitorque.Initially Reported on 830627.Existing Screws Will Be Replaced on Affected Valves Prior to Fuel Load.Maint Procedures Modified
DCL-84-007, Final Deficiency Rept Re Containment Spray Initiation Timing.Timer Setting for Starting of Containment Spray Pump Changed from Original FSAR Table 8.3-4 Value to Value of 26 & 22 for Pumps 1 & 2,respectively9 January 1984Final Deficiency Rept Re Containment Spray Initiation Timing.Timer Setting for Starting of Containment Spray Pump Changed from Original FSAR Table 8.3-4 Value to Value of 26 & 22 for Pumps 1 & 2,respectively
ML20082N64329 November 1983Part 21 Rept Re Detection of Deficiences in Quality Resulting from Fraudulent Actions by Suppliers.Util QA Dept Designed to Aggressively Monitor Supplier Activities
ML20082E65810 November 1983Final Deficiency Rept Re Capstan Spring Tang Cracks in Pacific Scientific Model PSA-3 Snubbers.Three Snubbers Will Be Replaced Prior to Fuel Load
ML20081H33328 October 1983Interim Deficiency Rept Re Three Potentially Defective Pacific Scientific Model PSA-3 Snubbers.Initially Reported on 831012.Next Rept Will Be Submitted in 30 Days
ML20072N9898 July 1983Interim Part 21 Rept Confirming 830705 Telcon Re Anomalies in Artificially Aged Apparatus (Using Ahrrenius Methodology W/Elevated Temp Aging).Deficiency Found During Qualification Testing for IEEE 323-1974.Draft Notices Encl
ML20024C39327 June 1983Interim Deficiency Rept Re Malfunction of Limitorque Valve Operator.Initially Reported on 830526.Investigation Continuing to Confirm Extent of Problem & Determine Corrective Action.Final Rept to Be Submitted by Fuel Load
ML20067B1818 November 1982Final Deficiency Rept Re Water Hammer Phenomenon in Auxiliary Saltwater Sys.Initially Reported on 821008. Isolable Vacuum Breaker Added to Auxiliary Saltwater Sys to Eliminate Water Hammer Effect.Design Change Forthcoming
ML20042A56116 March 1982Interim Deficiency Rept Re Inadequate Design of Sys Contained in Annulus Area of Containment Bldg,Initially Reported 811105.Further Info of Progress Is Identified in Suppls to LER 81-002
ML20039E94122 December 1981Final Deficiency Rept Re Containment Spray Sys Pipe Supports,Initially Reported 810918.Supports Reviewed, Qualified & Redesigned Per Corrected Support Loads.Changes to Be Completed Prior to Power Ascension
ML20038A6875 November 1981Deficiency Rept Re Design of Sys Contained in Annulus Area of Unit 2 Containment Bldg.Reviewing Affected Areas & Making Necessary Mods
ML20010F84527 August 1981Final Deficiency Rept Re Reactor Protection & Control Equipment,Initially Reported 810728.Addl Instructions Given to Personnel Re Requirements for Authorization of Work & Need for Review of Work Affecting Seismic Qualification
ML20004F58012 June 1981Interim Deficiency Rept Re 120 Volt Ac Vital Power Boards, Originally Reported 810514.Design of Neutral Block Attachments Will Be Modified.Final Rept by 810815
ML20004F75712 June 1981Interim Deficiency Rept,Originally Reported on 810514,re Design Deficiency in 120 Volt Ac Vital Power Panelboards. Design of Neutral Block Attachment Screws Modified.Final Rept by 810815
ML20086D02315 January 1975Final Deficiency Rept Re Steam Generator Primary Nozzle safe-ends.Initially Reported on 740329.Indications Removed by Grinding.Cracks Resulted from Intergranular Attack by Corrosive Environ.Corrective Steps ListedLiquid penetrant
ML20086D02828 August 1974Interim Deficiency Rept Re Exterior Surfaces of Unit 1 Steam Generator Nozzles.Initially Reported on 740424.Final Rept Submission Contingent on Conclusion of Repair Work,Presently Stalled by Series of Strikes
ML20086D04624 April 1974First Deficiency Rept Re Steam Generator Nozzle safe-end Cracking.Program of Exam & Investigation Begun.Cracking Is Superficial Surface Cracking Caused by Corrosive Attack Due to Exposure to Marine Environ.Final Rept Due 740601
ML20086D07514 February 1974Final Deficiency Rept Re NSSS Primary Loop Piping Welding Discrepancies.Initially Reported on 731024.Unauthorized Departure from Approved Procedures Corrected.Full Insp Revealed No Detrimental EffectsHydrostatic
Liquid penetrant
ML20086D10024 October 1973Preliminary Deficiency Rept Re NSSS Primary Loop Pipe Welding.Discrepant Conditions Discovered on 730920.Welding Halted Until Faulty Conditions Corrected.Wismer & Becker & Westinghouse Conducting InvestigationsNon-Destructive Examination
Liquid penetrant
ML20086D18321 August 1973Deficiency Rept Re Failure of Valves Important to Safety to Meet Min Wall Thickness Requirements.Valve Verification Program Underway.Of 97 Valves tested,37 Set Aside for Further Testing.Results of Tests Forthcoming
ML20086D13431 May 1973Deficiency Rept Re Integrity of Thermoplastic Insulation Jacket on 4.16-kV Metalclad Switchgear Bus Bars,Nonvital 12- Kv Metalclad Switchgear Buses & Related Bus Ducts.Insulation Sys Approved for Repairs Meets ANSI Std C-37.20
ML20086D15520 November 1972Deficiency Rept Re Reinforced Concrete Compartment Walls of Intake Structure.Design of Auxiliary Salt Water Pump Compartments Reviewed for Tsunami Loading.Design SatisfactoryHydrostatic