Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CC01PA Equipment Class: (5) Horizontal Pumps Equipment
Description:
2A COMPONENT COOLING WTR PUMP ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
DrawingM-1220 Sheet 4 Revision V
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-89
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CC01PA Equipment Class: (5) Horizontal Pumps Equipment
Description:
2A COMPONENT COOLING WTR PUMP ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Level glass is well-secured so there are no seismic/structuralissues Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/20/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-90
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: [-1 N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CC01PA Equipment Class: (5) Horizontal Pumps Equipment
Description:
2A COMPONENT COOLING WTR PUMP ASMBLY z~utuirt-A yron 1 at z jz-z 2CC01PA Byron 1 & 2 8-20-12 056 C-91
Byron Generating Station Unit 2 12Q0108:20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID'No.: 2CC9412A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
CC FROM RH HX 2A OUTLET ISOL ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-92
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CC9412A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
CC FROM RH HX 2A OUTLET ISOL ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic Walkdown Team M. Delaney & P. Gazda 8/20/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-93
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CC9412A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
CC FROM RH HX 2A OUTLET ISOL ASMBLY Photos C-94
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: E N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV01PA Equipment Class: (5) Horizontal Pumps Equipment
Description:
PUMP,2A CENTRIFUGAL CHARGING ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing M-1220 Sheet 2 Revision AB
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-95
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV01PA Equipment Class: (5) Horizontal Pumps Equipment
Description:
'PUMP,2A CENTRIFUGAL CHARGING ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on equipment.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/20/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-96
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV01PA Equipment Class: (5) Horizontal Pumps Equipment
Description:
PUMP,2A CENTRIFUGAL CHARGING ASMBLY Photos C-97
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV112E Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
RWST TO CHG PMPS SUCT VLV C/S AT 2PM05J ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-98
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: T] N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV112E Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
RWST TO CHG PMPS SUCT VLV C/S AT 2PM05J ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic Walkdown Team M. Delaney & P. Gazda 8/21/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-99
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV1 12E Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
RWST TO CHG PMPS SUCT VLV C/S AT 2PM05J ASMBLY Photos Photos C-100
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV8105 Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
CHG LINE CNMT ISOL VLV C/S AT 2PM05J ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 375.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-101
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV8105 Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
CHG LINE CNMT ISOL VLV C/S AT 2PM05J ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic Walkdown Team M. Delaney & P. Gazda 8/21/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-102
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV8105 Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
CHG LINE CNMT ISOL VLV C/S AT 2PMO5J ASMBLY Photos zLuvtiuo byron 1 & z ts-z1-iz uzi C-103
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: Mi N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV8804A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
RH HX 2A TO CV PMP SUCT ISOL VLV; C/S AT 2PM06J ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchoracqe
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-104
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV8804A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
RH HX 2A TO CV PMP SUCT ISOL VLV; C/S AT 2PM06J ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismic issues Comments Seismic Walkdown Team M. Delaney & P. Gazda 8/21/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-105
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2CV8804A Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
RH HX 2A TO CV PMP SUCT ISOL VLV; C/S AT 2PM06J ASMBLY Photos 2CV8804A Byron 1 & 2 8-21-12 012 C-106
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC02E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC BATT 212 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchoraae
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-3391A Y Revision B
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-107
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC02E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC BATT 212 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Chain hung lights appearto have closed S-hooks. IR 1399385 written since all S-hooks cannotbe seen from the floor and may be open. Lights would not impact equipment based on that they are double chained.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safetyfunctions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-108
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC02E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC BATT 212 Photos C-109
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC02E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC BATT 212 C-110
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC03E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
BATTERY CHARGER 211 DIV. 21 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 if, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchoraae
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes Adjacent small crack (northwest comer) - not a structural/seismicissue
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-339 IC Revision BE
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-111
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC03E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
BATTERY CHARGER 211 DIV. 21 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment.or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Nearby masonry wall is seismic and would not collapse on equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
2DCO3E is not bolted to adjacentpanel 2DCO5E. Per Operations,no relays or other electrical components whose position could change during a seismic event are contained in either cabinet.
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am, 8/8/12am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-112
Byron Generating Station Unit 2 12Q01 08.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC03E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
BATTERY CHARGER 211 DIV. 21 Photos zuLuwt- tyron 1 z u014 C-1 13
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: IN U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC04E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
BATTERY CHARGER 212 DIV. 22 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchoracqe
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-3391C Revision BE
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-114
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC04E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
BATTERY CHARGER 212 DIV. 22 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Adjacent cabinet 2DCO6Eis not bolted to 2DCO4E however per Operations, no relays or other electricalcomponents whose position could change during a seismic ~v,.~nt *r* cnntin*.d in v.ith*.r c.*hin*tt Other Adverse Conditions
..11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am, 8/8/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-115
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC04E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
BATTERY CHARGER 212 DIV. 22 Photos C-116
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC04E Equipment Class: (16) Battery Chargers and Inverters EauiDment DescriDtion: BATTERY CHARGER 212 DIV. 22 C-117
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC05E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 211 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 452.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchora-ge
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes Only mild corrosion - not a structural/seismicissue since anchorage configurationis maintained.
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies ifthe item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-3391C Revision BE Weld exceeds drawing specified weld detail
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-118
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC05E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 211 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Adjacent cabinets 2DCO3Eand 2DCO5E do not appearto be bolted together however per Operations,no relays or other electricalcomponents whose position could change duringa seismic event are contained in either cabinet.
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am, 8/8/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-119
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC05E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 211 Photos rn~
I 2DC05E Byron 1 & 2 011 C-120
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC05E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 211 C-121
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 212 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-3391C Revision BE Weld exceeds drawing requirements
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-122
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 212 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on equipment
- 9. Do attached-lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Adjacent panel 2DCO4E is not bolted to 2DCO6E. Per operationsneither cabinet contains relays therefore this is acceptable.
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am, 8/8/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-123
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 212 Photos C-124
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06E Equipment Class: (15) Batteries on Racks Equipment
Description:
125V DC ESF DIST CENTER 212 C-125
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06EA Equipment Class: . (14) Distribution Panels Equipment
Description:
125V DC ESF DIST PNL 212 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies ifthe item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-339 1C Revision BE Part of 2DCO6E .
Weld exceeds drawing requirements
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-126
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06EA Equipment Class: (14) Distribution Panels Equipment
Description:
125V DC ESF DIST PNL 212 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-127
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC06EA Equipment Class: (14) Distribution Panels Equipment
Description:
125V DC ESF DIST PNL 212 Photos Byron 1 & 2 029 2DC06EA C-128
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: E N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC10J Equipment Class: (14) Distribution Panels Equipment
Description:
125V DC FUSE PANEL - DIV. 21 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may. be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-339 1E Revision AT Panel is well-anchored. Anchor spacing varies from drawing but anchorsize of 5/8" requiresa minimum spacing of 7 1/2" per DCS 24.1.2 Revision 1, the as-builtspacing of 9" is greaterthan the minimum spacing and is acceptable.
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-129
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC1OJ Equipment Class: (14) Distribution Panels Equipment
Description:
125V DC FUSE PANEL - DIV. 21 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Other miscellaneous issues:
Cable tray riser- cables are contained at base and at top with grips. Riser is well-supported at top and bottom - not a structural/seismicissue and is acceptable.
Small, hairlinecracks are not a structural/seismicissue.
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am, 8/8/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-130
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC1OJ Equipment Class: (14) Distribution Panels Equipment
Description:
125V DC FUSE PANEL - DIV. 21 Photos 2DC10J (Q 1 & 2 020 C-131
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DC1OJ Equipment Class: (14) Distribution Panels Equipment
Description:
125V DC FUSE PANEL - DIV. 21 C-132
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: iI N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DG01KA Equipment Class: (17) Engine-Generators Equipment
Description:
2A DIESEL GENERATOR SKID Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
DrawingM-1222 Sheet 8 Revision J
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-133
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DG01KA Equipment Class: (17) Engine-Generators Equipment
Description:
2A DIESEL GENERATOR SKID Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Small oil leaks - not a structural/seismicissue Comments Seismic walkdown team M. Delaney & P. Gazda 8/7/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-134
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. I Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DGOIKA Equipment Class: (17) Engine-Generators Equipment
Description:
2A DIESEL GENERATOR SKID Photos C-135
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DG01KA Equipment Class: (17) Engine-Generators Eauioment Descriotion: 2A DIESEL GENERATOR SKID C-136
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DO01TA Equipment Class: (21) Tanks and Heat Exchangers Equipment
Description:
DIESEL OIL STORAGE TANK Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 373.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes Very minor cracks in grout wash does not penetrate into grout or base slab.
Not a structural/seismicissue.
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing M-1214 Sheet 3 Revision W
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-137
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DO01TA Equipment Class: (21) Tanks and Heat Exchangers Equipment
Description:
DIESEL OIL STORAGE TANK Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-138
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: F N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2DOO1TA Equipment Class: (21) Tanks and Heat Exchangers Equipment
Description:
DIESEL OIL STORAGE TANK Photos None.
C-139
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC004A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX TUBE SIDE VENT VALVE Project: Byron 2 SWEL Location (Bidg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchora-ae
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-140
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: Mi N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC004A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX TUBE SIDE VENT VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and will not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-141
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC004A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX TUBE SIDE VENT VALVE Photos Zt-L;UU4A byron 1i6, z ti-to-1z LXS C-1 42
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC004B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX SHELL SIDE VENT Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-143
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC004B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX SHELL SIDE VENT Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-144
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC004B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX SHELL SIDE VENT Photos 2FC004B Byron 1 & 2 8-9-12 049 C-145
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC005 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP CASING DRN VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Waikdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies ifthe item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-146
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC005 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP CASING DRN VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 A 4 Philip Gazda 10/5/2012 C-147
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC005 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP CASING DRN VALVE Photos zt-uuuo byron i ot /- ts-viz u-ju C-148
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC006 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP CASING VENT VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-149
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC006 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP CASING VENT VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-150
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC006 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP CASING VENT VALVE zr-Uuuo byron 1 & z t-v-lz uaz C-151
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC011 Equipment Class: (0) Other Equipment
Description:
SFP FLT DEMIN LOOP RTRN TO U-2 REFUEL CAV CNMT ISOL VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-152
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: Mf N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC011 Equipment Class: (0) Other Equipment
Description:
SFP FLT DEMIN LOOP RTRN TO U-2 REFUEL CAV CNMT ISOL VALVE Interaction Effects 7' Are soft targets free from impact by nearby equipment or structures? Yes Handrailmodified to provide clearance for valve and to prevent spatial interaction issues. Clearancesare relatively large for potentialpipe movements during a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Valve is weIl-supported at penetrationand downstream.
Comments Seismic walkdown team M. Delaney & P. Gazda 8/21/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-153
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC011 Equipment Class: (0) Other Equipment
Description:
SFP FLT DEMIN LOOP RTRN TO U-2 REFUEL CAV CNMT ISOL VALVE Photos C-154
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC01A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HEAT EXCHANGER Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchoracqe
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
DrawingM-1219 Sheet 3 Revision AH
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-155
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC01A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HEAT EXCHANGER Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-156
Byron Generating Station Unit 2 1200108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC01A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HEAT EXCHANGER Photos ztruui#A iyron 1 & z ij-w-1e uoi C-157
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC01P Equipment Class: (5) Horizontal Pumps Equipment
Description:
PUMP,SPENT FUEL PIT 12X14-14 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing M-1219 Sheet 3 Revision AH
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-158
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC01P Equipment Class: (5) Horizontal Pumps Equipment
Description:
, PUMP,SPENT FUEL PIT 12X14-14 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-159
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC01P Equipment Class: (5) Horizontal Pumps Equipment
Description:
PUMP,SPENT FUEL PIT 12X14-14 Photos 2FC01 P Byron 1 & 2 8-9-12 026 C-160
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FCOIP Equipment Class: (5) Horizontal Pumps Eauioment
Description:
PUMP.SPENT FUEL PIT 12X14-14 zmui t- byron -i dt z ts-u--iz uzo C-161
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet I of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC022 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCT INST ISOL TO 2PI-633 VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchoracqe
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-1 62
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: [T N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC022 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCT INST ISOL TO 2PI-633 VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacent equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012
(* */ "Philip Gazda 10/5/2012 C-163
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC022 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCT INST ISOL TO 2PI-633 VALVE 2PUL;22 byron 1 & 2 d-U-12 Ub4 C-164
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: MI N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8756 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCTION VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-165
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8756 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCTION VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked.for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-166
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8756 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCTION VALVE Photos C-167
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: F N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8757 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCT INST ROOT TO 2PI-633 VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-168
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8757 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCT INST ROOT TO 2PI-633 VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismicinteraction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-169
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8757 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP SUCT INST ROOT TO 2PI-633 VALVE Photos C-170
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-1 2-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8758 Equipment Class: (0) Other Equipment
Description:
REFUELING WTR PURIF PMP SUCT FROM U-2 RWST Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-171
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8758 Equipment Class: (0) Other Equipment
Description:
REFUELING WTR PURIF PMP SUCT FROM U-2 RWST Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/21/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-172
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8758 Equipment Class: (0) Other Equipment
Description:
REFUELING WTR PURIF PMP SUCT FROM U-2 RWST Photos C-173
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8762A Equipment Class: (21) Tanks and Heat Exchangers Equipment
Description:
SPENT FUEL PIT HX INLET VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies ifthe item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-174
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8762A Equipment Class: (21) Tanks and Heat Exchangers Equipment
Description:
SPENT FUEL PIT HX INLET VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacent equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Boron leak IR tag attachedto valve. Leak not active. Not a structural/seismic issue.
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-175
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: Y N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8762A Equipment Class: (21) Tanks and Heat Exchangers Equipment
Description:
SPENT FUEL PIT HX INLET VALVE Photos 21- LXI 16ZA b~yron 1 & z ts-9-12zu~i C-1 76
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8762B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX OUTLET VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? -Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-177
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8762B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX OUTLET VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not'likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacent equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 6 ' */*4"
- Philip Gazda 10/5/2012 C-178
Byron Generating Station Unit 2 12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8762B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX OUTLET VALVE Photos None.
C-179
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8792A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX TUBE SIDE DRN VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-180
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: F N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8792A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX TUBE SIDE DRN VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacent equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-181
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: FTN U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8792A Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX TUBE SIDE DRN VALVE 2FC8792A Byron 1 & 2 8-9-12 043 C-182
12Q0108.20-R-002 Rev. I Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8792B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX SHELL SIDE DRN VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-183
12Q-108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8792B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX SHELL SIDE DRN VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluatedby: Marlene Delaney Date: 10/5/2012 62 *
- Philip Gazda 1015/2012 C-184
1200108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: MI- N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8792B Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT HX SHELL SIDE DRN VALVE Photos zi-u15ThJm uyron 1 & z a5-9-1z u45 C-185
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8793 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP DISCH CHECK VALVE Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): FH, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No
. of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-186
12Q-108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8793 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP DISCH CHECK VALVE Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacent equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/9/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-187
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FC8793 Equipment Class: (0) Other Equipment
Description:
SPENT FUEL PIT PMP DISCH CHECK VALVE Photos zt-U~ts$(V byron 1 & Z U-9-1 Z U34 C-188
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: MI- N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FT-AF012 Equipment Class: (18) Instruments on Racks Equipment
Description:
AF TO SG 2A FLOW TRANSMITTER Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
Instrument is securely attached to Rack 2PL84JB which is well-braced and anchored.
C-189
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FT-AF012 Equipment Class: (18) Instruments on Racks Equipment
Description:
AF TO SG 2A FLOW TRANSMITTER Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/20/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-190
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2FT-AF012 Equipment Class: (18) Instruments on Racks Equipment
Description:
AF TO SG 2A FLOW TRANSMITTER Photos 2FT-AF012 Byron 1 & 2 8-20-12 069 C-191
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P02E Equipment Class: (4) Transformers Equipment
Description:
INSTRUMENT BUS 212 TRANSFORMER - DIV. 22 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-192
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P02E Equipment Class: (4) Transformers Equipment
Description:
INSTRUMENT BUS 212 TRANSFORMER - DIV. 22 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacent equipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-193
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P02E Equipment Class: (4) Tran isformers Equipment
Description:
INSTRLJMENT BUS 212 TRANSFORMER - DIV. 22 Photos C-1 94
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P05E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
INSTRUMENT BUS 211 INVERTER - DIV. 21 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-3391C Revision BE
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-195
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P05E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
INSTRUMENT BUS 211 INVERTER - DIV. 21 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-196
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P05E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
INSTRUMENT BUS 211 INVERTER - DIV. 21 Photos None.
C-197
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P06E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
INSTRUMENT BUS 212 INVERTER - DIV. 22 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
Drawing 6E-0-3391C Revision BE (anchorage visible through panel at base of equipment)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-198
12Q-108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: E-i N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P06E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
INSTRUMENT BUS 212 INVERTER - DIV. 22 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Masonry walls are seismic and would not collapse on adjacentequipment
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-199
1200108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: MI- N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21P06E Equipment Class: (16) Battery Chargers and Inverters Equipment
Description:
INSTRUMENT BUS 212 INVERTER - DIV. 22 Photos C-200
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21Y-0606 Equipment Class: (18) Instruments on Racks Equipment
Description:
RH HX 2A OUT I/P TRANSDUCER Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 364.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
Instrument is securely attached to Rack 2PL86J which is well-braced and anchored.
C-201
12Qo108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: F] N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21Y-0606 Equipment Class: (18) Instruments on Racks Equipment
Description:
RH HX 2A OUT I/P TRANSDUCER Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/20/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 6711 Philip Gazda 10/5/2012 C-202
12001 08.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 21Y-0606 Equipment Class: (18) Instruments on Racks Equipment
Description:
RH HX 2A OUT I/P TRANSDUCER Photos C-203
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS001C Equipment Class: (7) Fluid-Operated Valves Equipment
Description:
MS ISOL VLV LOOP 2C ASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 377.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-204
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: L-] N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS001C Equipment Class: (7) Fluid-Operated Valves Equipment
Description:
MS ISOL VLV LOOP 2C ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
One bolt missing at accumulator(top of valve), typical for all valves of this type. Station personnelcontacted and missing bolts are acceptable since they are only used for rigging. Not a seismic/structuralissue.
Degradationat expansionjoint with containment wall (at ceiling)- not a structural/seismicissue. The joints in question are made up of some sort of compressible/flexible material. Since the containment structure is a standalonestructure and is analyzed and designed that way there is a gap between it and an adjacentstructure (like the MSIV rooms). The gap is sized to allow seismic movements of each structure and is filled with the flexible material. The material is only there to close the opening and has no structural or seismic significance.
Comments Seismic walkdown team M. Delaney & P. Gazda 8/7/12 am C-205
1200108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: MI- N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MSI001 Equipment Class: (7) Fluid-Operated Valves Equipment
Description:
MS ISOL VLV LOOP 2C ASMBLY Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 Photos C-206
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: [M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS001 C Equipment Class: (7)Fluid-Operated Valves Fnminm.nt Dnpqrintinn: MS ISOL VLV LOOP 2C ASMBLY C-207
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet I of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS018C Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
S/G 2C PORV Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 404.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? NotApplicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-208
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS018C Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
S/G 2C PORV Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
No structural/seismicissues Comments Seismic walkdown team M. Delaney & P. Gazda 8/7/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-209
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS018C Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
S/G 2C PORV Photos C-2 10
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: T N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS018D Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
S/G 2D PORVASMBLY Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 401.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
C-21 1
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: V N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS018D Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
S/G 2D PORV ASMBLY Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to co!lapse onto the equipment?
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/7/12 am Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-212
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2MS018D Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
S/G 2D PORV ASMBLY Photos C-213
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 4 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA01J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 1 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-214
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 4 Status: T N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA01J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 1 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted together to eliminate spatial interactionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-215
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 4 Status: [-v N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA01J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 1 0-3373B AB2 Photos C-216
-I2Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 4 of 4 Status: N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA01J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 1 0-3373B AB2 C-217
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA02J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 2 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-218
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA02J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 2 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted together to eliminate spatialinteractionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengaged in a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-219
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA02J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 2 0-3373B AB2 Photos C-220
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet I of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA03J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 3 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-221
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA03J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 3 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinetsare bolted togetherto eliminate spatialinteractionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-222
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA03J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 3 0-3373B AB2 zt--u~jj byron 1 & z u~o C-223
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA04J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 4 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussionin Section 5 of report to addresscove molding at anchorage detail. Anchorage is judged to be acceptable.
C-224
12Q1 08.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA04J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 4 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted togetherto eliminate spatialinteractionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-225
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: MI- N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA04J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK PROT CH 4 0-3373B AB2 Photos C-226
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA06J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 2 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to addresscove molding at anchorage detail. Anchorage is judged to be acceptable.
C-227
12Q-108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: FT N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA06J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 2 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted together to eliminate spatialinteractionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengaged in a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found' no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-228
12Q0108.20-R-002 Rev. I Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M-I N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA06J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 2 0-3373B AB2 Photos C-229
12Q0108.20-R-002 Rev. I Correspondence No.: RS-12-161 Sheet I of 3 Status: F N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA07J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 3 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-230
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA07J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 3 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted together to eliminate spatial interaction during a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengaged in a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 C . Philip Gazda 10/5/2012 C-231
12Q01 08.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA07J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 3 0-3373B AB2 Photos C-232
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: LIII N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA08J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 4 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-233
1200108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M-N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA08J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 4 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Bolted to adjacentpanel 2PAO7J. Adjacent cabinets are bolted together to eliminate spatial interactionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-234
I 2Q01 08.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA08J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROC I+C RACK CONT GRP 4 0-3373B AB2 Photos C-235
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA09J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROT SYST SOL ST RX/ESF TRN A 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This. checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-236
1200108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA09J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROT SYST SOL ST RX/ESF TRN A 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Externally bolted to adjacentPanel2PA 11J in back of paneL Interiorbolting present at front to 2PA 11J and both sides to 2PA33J. Adjacent cabinets are bolted together to eliminate spatialinteraction during a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengaged in a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 43rý Philip Gazda 10/5/2012 C-237
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA09J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROT SYST SOL ST RX/ESF TRN A 0-3373B AB2 Photos C-238
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA10J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROT SYST SOL ST RX/ESF TRN B 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary,, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-239
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA10J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROT SYST SOL ST RX/ESF TRN B 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted together to eliminate spatial interactionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block Walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could, Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-240
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3of 3 Status: T N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA1 OJ Equipment Class: (20) Insrumentation and Control Panels and Cabinets Equipment
Description:
CAB PROT SYST SOL ST RX/ESF TRN B 0-3373B AB32
,Photos C-241
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA11J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB TEST SAFEGUARD TRN A 0-3373B AB3 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of reportto address cove molding at anchorage detail. Anchorage isjudged to be acceptable.
C-242
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA11J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB TEST SAFEGUARD TRN A 0-3373B AB3 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Bolted to adjacent Panel2PAO9J externally on back of panel and on through the interiorsides on the front of the panel. (Panelwas opened) Adjacent cabinets are bolted together to eliminate spatial interactionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-243
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA11J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB TEST SAFEGUARD TRN A 0-3373B AB3 Photos C-244
120Q108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA12J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB TEST SAFEGUARD TRN B 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-245
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA12J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB TEST SAFEGUARD TRN B 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted togetherto eliminate spatialinteractionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 816112 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-246
12Q0108.20-R-002 Rev. I Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA12J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB TEST SAFEGUARD TRN B 0-3373B AB2 Photos C-247
12Q-10820-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: iTI N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA13J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB ESF SEQ/ACT TRN A 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-248
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: F N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA13J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB ESF SEQ/ACT TRN A 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted togetherto eliminate spatialinteractionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-249
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA13J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB ESF SEQ/ACT TRN A 0-3373B AB2 Photos C-250
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA14J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB ESF SEQ/ACT TRN B 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-251
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA14J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB ESF SEQ/ACT TRN B 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted togetherto eliminate spatialinteraction during a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. lR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-252
12QO0108.*2R-002 Rev.
Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA14J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB ESF SEQ/ACT TRN B 0-3373B AB2 Photos C-253
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: V N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA27J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB RELAY AUX SAFEGUARD TRN A 0-3373B AB2 Project: . Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-254
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA27J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB RELAY AUX SAFEGUARD TRN A 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted togetherto eliminate spatial interactionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-255
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: FTN U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA27J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB RELAY AUX SAFEGUARD TRN A 0-3373B AB2 Photos z tAzUt tyron -i a, z u (
C-256
12QO108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 1 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA28J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB RELAY AUX SAFEGUARD TRN B 0-3373B AB2 Project: Byron 2 SWEL Location (Bldg, Elev, Room/Area): Auxiliary, 451.00 ft, ALL Manufacturer/Model:
Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.
Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2. Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3. Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5. Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6. Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?
See discussion in Section 5 of report to address cove molding at anchorage detail. Anchorage is judged to be acceptable.
C-257
12Q-108.20-R-002 Rev. I Correspondence No.: RS-12-161 Sheet 2 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA28J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB RELAY AUX SAFEGUARD TRN B 0-3373B AB2 Interaction Effects
- 7. Are soft targets free from impact by nearby equipment or structures? Yes Adjacent cabinets are bolted together to eliminate spatial interactionduring a seismic event.
- 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
Partiallyopen S-hooks on lights. IR 1397694 was written to inspect and close S-hooks. S-hooks are not likely to become disengagedin a seismic event since they are not fully open and are therefore acceptable.
- 9. Do attached lines have adequate flexibility to avoid damage? Yes
- 10. Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects?
Other Adverse Conditions
- 11. Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?
Comments Seismic walkdown team M. Delaney & P. Gazda 8/6/12 pm Evaluated by: Marlene Delaney Date: 10/5/2012 Philip Gazda 10/5/2012 C-258
12Q0108.20-R-002 Rev. 1 Correspondence No.: RS-12-161 Sheet 3 of 3 Status: M N U Seismic Walkdown Checklist (SWC)
Equipment ID No.: 2PA28J Equipment Class: (20) Instrumentation and Control Panels and Cabinets Equipment
Description:
CAB RELAY AUX SAFEGUARD TRN B 0-3373B AB2 Photos C-259