PNO-I-05-020, A: Supplement - Entergy'S Fitzpatrick Station Shutdown 72 Hrs; Repair Small Crack in Torus Portion of Primary Containment

From kanterella
(Redirected from PNO-I-05-020)
Jump to navigation Jump to search
PNO-I-05-020A: Supplement - Entergy'S Fitzpatrick Station Shutdown 72 Hrs; Repair Small Crack in Torus Portion of Primary Containment
ML051930351
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 07/12/2005
From: Brian Mcdermott
Reactor Projects Branch 2
To:
References
PNO-I-05-020A
Download: ML051930351 (2)


DCS No.: 05000333050630 Date: July 12, 2005 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE -- PNO-I-05-020A This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by the Region I staff on this date.

Facility Entergy Nuclear Northeast Licensee Emergency Classification James A. FitzPatrick Nuclear Power Plant Notification of Unusual Event Lycoming, New York 13093 Alert Site Area Emergency Docket: 50-333 General Emergency License: DPR-059 X Not Applicable

SUBJECT:

SUPPLEMENT - SHUTDOWN TO REPAIR SMALL CRACK IN THE TORUS PORTION OF PRIMARY CONTAINMENT On July 7, a Special Inspection Team was dispatched to inspect and assess corrective actions for cracks in the torus shell and a shutdown cooling (SDC) pipe discovered by the licensee on June 27 and July 4, respectively. The inspection team completed its initial review of the licensee's repair work, preliminary root cause evaluations, extent-of-condition evaluations, and corrective actions prior to restart of the reactor. The special inspection will continue after the plant restart for further assessment, including a review of equipment issues that may constitute potential generic concerns.

Entergy completed a permanent repair of the torus shell in accordance with ASME code requirements and subsequently pressure tested the primary containment. The inspection team reviewed the licensee's repair plans, observed work in the plant, and reviewed the results of post-repair non-destructive examinations.

On July 4, during the plant shutdown for repair of the torus, Entergy identified a crack on the residual heat removal system's shutdown cooling (SDC) suction line. The SDC subsystems were declared inoperable based on the presence of a through-wall defect on an ASME Class 2 pipe. Notwithstanding the TS inoperability, the SDC suction line remained in service and fully capable of providing decay heat removal. Entergy repaired the crack and tested the SDC line in accordance with ASME code requirements, prior to restart of the reactor. While the SDC function is not credited in the FitzPatrick Safety Analyses, the system is designed to remove decay heat from the reactor coolant system. Alternate methods of decay heat removal were available.

The special inspection team's review is projected to be complete in August, and the inspection results will be documented in an inspection report within 45 days of the exit meeting. An NRC press release was issued on July 7 to inform the public that a Special Inspection was initiated for this event. In addition, the State of New York has been updated on current status.

CONTACT: John R. White Brian J. McDermott (610) 337-5114 (610) 337-5233

DISTRIBUTION: (PN Recipient List)

OWFN TWFN LST Chairman Diaz IRO PDR Comm. Merrifield NMSS Comm. Jaczko ACRS Comm. Lyons OIG OIP RES OCA NSIR OGC OPA EDO OE NRR SECY Regional Offices By Fax:

DOT:Trans INPO NSAC RI Resident Office Licensee: Entergy Nuclear Northeast ADAMS Document Accession No.: ML051930351 SISP Review Complete: ___BJM____ (Reviewers Initials)

DOCUMENT NAME: E:\Filenet\ML051930351.wpd After declaring this document An Official Agency Record it will be released to the Public.

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRP RI/ORA RI/PAO RI/DRP NAME BMcDermott RBores DScrenci BHolian DATE 07/12/05 07/12 /05 07/12 /05 07/12 /05 OFFICIAL RECORD COPY Region I Form 83 (Rev. July 2, 2003)