NL-10-097, Registration of Spent Fuel Cask Use

From kanterella
(Redirected from NL-10-097)
Jump to navigation Jump to search
Registration of Spent Fuel Cask Use
ML102670190
Person / Time
Site: Indian Point, Holtec  Entergy icon.png
Issue date: 09/17/2010
From: Robert Walpole
Entergy Nuclear Northeast
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-10-097
Download: ML102670190 (2)


Text

Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB

-Entergy P.O. Box 249 Buchanan, N.Y. 10511-0249 Tel (914) 734-6710 Robert Walpole Manager Licensing Tel (914) 734-6710 NL-10-097 September 17, 2010 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Indian Point Energy Center Registration of Unit 2 Spent Fuel Cask Use Indian Point, Unit 2 Docket Nos. 50-247 & 72-51 License No. DPR-26 Dear Sir or Madam; Entergy Nuclear Operations, Inc. (Entergy) operates the Indian Point Energy Center (IPEC)

Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 10 CFR 72.210. The conditions of 10 CFR 72.212(b)(1)(ii) include the registration of a spent fuel cask within 30 days of using a cask for storage of spent nuclear fuel.

Accordingly, this letter hereby registers the use, on August 20, 2010, of the ninth (9) IPEC Unit 2 dry fuel storage cask. The cask was loaded to Amendment #2 of the Holtec CoC #1014 and the corresponding Holtec CFSAR Revision 4. This cask is the fourteenth (14) IPEC dry fuel storage cask to be added to the IPEC ISFSI pad.

This letter also provides the following registration information associated with the fourteenth Holtec HI-STORM 100 spent fuel cask system that was placed into storage on the IPEC ISFSI pad [Docket No. 72-51]. The fuel contained in this cask is from IPEC Unit 2 Nuclear Power Plant, Reactor License No. DPR-26, Docket No. 50-247.

[Ninth Unit 2 Spent Fuel Cask]

Fourteenth IPEC Spent Fuel Cask System Date placed in use: August 20, 2010 Licensee's Name: Entergy Operations, Inc.

Licensee's Address: Indian Point Energy Center 450 Broadway P.O. Box 249 Buchanan, NY 10511 Cask Model Number: HI-STORM 100 Cask Certificate Number: 1014 MPC Serial Number: 101 HI-STORM Overpack Serial Number: 0376 Number of Fuel Bundles: 32 fuel bundles

Indian Point Unit 2 Docket Nos. 50-247 & 72-51 License No. DPR-26 NL-10-097 Page 2 of 2 Total Cask Systems stored at the IPEC ISFSI pad [Docket No. 72-511:

Fourteen (14) HI-STORM 100 Cask Systems Entergy is making no new commitments in this letter. Should you have any questions regarding this matter, please contact Mr. Timothy J. Salentino, Superintendent Dry Fuels Storage, at Indian Point Energy Center at (914) 734-6421.

Sincerely yours, Robert Walpole Manager, Licensing Indian Point Energy Center cc: NRC Resident Inspector's Office Mr. John Boska, Senior Project Manager, NRC NRR DORL Mr. Theodore Smith, Project Manager, NRC FSME DWMEP Mr. Marc Depas, Acting Regional Administrator, NRC Region 1 Mr. Francis J. Murray, Jr., President and CEO, NYSERDA Mr. Paul Eddy, New York State Dept. of Public Service