ATTACHMENT 2 James A. FitzPatrick Nuclear Power Plant Renewed Facility Operating License No. DPR-59 NRC Docket No. 50-333 Response to Request for Additional Information - Non-Proprietary

Response to Request for Additional Information Page 1 of 5 Fuel Handling Accident Analysis Docket No. 50-333 By letter dated August 3, 2023 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML23215A012), Constellation Energy Generation, LLC (CEG) submitted to the U.S. Nuclear Regulatory Commission (NRC) a license amendment request (LAR) to update the Technical Specification Bases to change the fuel handling accident analysis.

Additional information is needed for the NRC staff to continue its review of this LAR.

The NRC staff is reviewing the LAR using the following regulations and guidance:

Title 10 of the Code of Federal Regulations (10 CFR), Part 50.67(b) states, in part, the following:

[a] licensee who seeks to revise its current accident source term in design basis radiological consequence analyses shall apply for a license amendment under § 50.90. The application shall contain an evaluation of the consequences of applicable design basis accidents previously analyzed in the safety analysis report.

Regulatory Analysis Basis

1. Section 10 CFR Part 50.67, Accident Source Term, allows licensees seeking to revise their current accident source term in design basis radiological consequence analyses to apply for a license amendment under § 50.90. The application shall contain an evaluation of the consequences of applicable design basis accidents previously analyzed in the safety analysis report. Section 50.67(b)(2) requires that the licensee's analysis demonstrates with reasonable assurance that:

(iv)

An individual located at any point on the boundary of the exclusion area for any 2-hour period following the onset of the postulated fission product release, would not receive a radiation dose in excess of 0.25 Sv (25 rem) total effective dose equivalent (TEDE).

(v)

An individual located at any point on the outer boundary of the low population zone, who is exposed to the radioactive cloud resulting from the postulated fission product release (during the entire period of its passage), would not receive a radiation dose in excess of 0.25 Sv (25 rem) TEDE.

(vi)

Adequate radiation protection is provided to permit access to and occupancy of the control room under accident conditions without personnel receiving radiation exposures in excess of 0.05 Sv (5 rem) TEDE for the duration of the accident.

2. Section 10 CFR Part 50, Appendix A, General Design Criterion (GDC) for Nuclear Power Plants: GDC 19, requires that a control room be provided from which actions can be taken to operate the nuclear power unit safely under normal conditions and to maintain it in a safe condition under accident conditions, including loss-of-coolant accidents. It also states that adequate radiation protection is provided to permit access and occupancy of the control room under accident conditions without personnel receiving radiation exposures in excess of 5 rem whole body, or its equivalent to any part of the body, for the duration of the accident.

Response to Request for Additional Information Page 2 of 5 Fuel Handling Accident Analysis Docket No. 50-333

3. NUREG-0800, Standard Review Plan (SRP) Section 6.4, Control Room Habitability System, Revision 3, March 2007; Section 6.5.2, Containment Spray as a Fission Product Cleanup System, Revision 4, March 2007; and Section 15.0.1, Radiological Consequences Analyses Using Alternative Source Terms, Revision 0, July 2000.
4. NRC Regulatory Guide (RG) 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors, July 2000 (ADAMS Accession No. ML003716792).

RAI ARCB #1

Background:

In section 1.0 Purpose, of the document CALCULATION NO. JAF-CALC-RAD-04410 as provided in Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis Dated August 31, 2023, three time frames are described for fuel handling accident analysis. The shortest timeframe for analysis of a fuel handling accident is 0 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. In the current licensing basis, a minimum of 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> is identified as the minimum amount of decay time required before fuel can be removed from the core.

Question:

Throughout the application and the supplement there is no minimum decay time after reactor shutdown that is identified before fuel handling can commence. Please provide information as to what the minimum decay time will be for commencement of fuel handling, or where this information can be identified.

Response to RAI ARCB #1:

In the original AST licensing basis approved with ML022350228, the only case assumed a minimum of 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> before fuel handling could commence. However, shortly after that, the licensing basis was updated by 10 CFR 50.59 and currently outlined in the UFSAR to contain two cases based on total decay time. There is an initial case assuming no decay time but with an isolated and operable secondary containment. The second case assumes 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> of decay but inoperable secondary containment. This change to the licensing basis was justified as being acceptable via 10 CFR 50.59 because the no decay time case with secondary containment operable was significantly less than the 96-hour decay time case (FSAR-02-075, dated September 25th, 2002).

With this licensing amendment, the analysis will be changed to cover three distinct time frames covering all times post reactor shutdown, down to 0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />. If irradiated fuel were to be moved with <24 hours of decay, the 0 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> case which includes an operable secondary containment would apply. Then at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> out to 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br />, the 24 to 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> case with an inoperable secondary containment but an operable Control Room Emergency Ventilation Air Supply (CREVAS) would apply. Lastly, after 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br />, the >104 hours case with an inoperable secondary containment and an inoperable CREVAS would apply.

Response to Request for Additional Information Page 3 of 5 Fuel Handling Accident Analysis Docket No. 50-333 RAI ARCB #2

Background:

In Regulatory Guide 1.183 Appendix B, Assumptions for Evaluation the Radiological Consequences of a Fuel Handling Accident, Section 1 Source Term it states:

The number of fuel rods damaged during the accident should be based on a conservative analysis that considers the most limiting case. This analysis should consider parameters such as the weight of the dropped heavy load or the weight of a dropped fuel assembly (plus any attached handling grapples), the height of the drop, and the compression, torsion, and shear stresses on the irradiated fuel rods. Damage to adjacent fuel assemblies, if applicable (e.g., events over the reactor vessel), should be considered.

In section 2.1, Source Term of the document CALCULATION NO. JAF-CALC-RAD-04410 as provided in Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis Dated August 31, 2023, it is stated:

The fraction of the core fuel damaged for GNF2, a 10x10 bundle design with 85.6 equivalent full length rods, and GNF3, also a 10x10 bundle design but with 88.32 equivalent full length rods, are based on 172 damaged fuel rods in a GNF2 fuel assembly with the NF-500 mast and 169 ruptured fuel rods in a GNF3 fuel assembly with the NF-500 mast (Reference 29).

Question:

Please provide further information associated with the source term for this accident analysis.

Specifically, please describe the number of assemblies damaged in the postulated accident including any impacted and/or adjacent assemblies, and the number of fuel rods damaged in each fuel assembly. Please provide any necessary discussion of the items included in RG 1.183 Appendix B, Section 1.

Response to RAI ARCB #2:

Based on the General Electric Hitachi (GEH) document 002N5644, Rev. 1, the following amount of fuel damage would occur during the bounding accident of a Fuel Handling Accident over the reactor vessel at FitzPatrick:

Fuel Type Dropped Fuel Impacted Fuel Total Failed Fuel GNF2

((

))

(( ))

((

))

GNF3

((

))

(( ))

((

))

Response to Request for Additional Information Page 4 of 5 Fuel Handling Accident Analysis Docket No. 50-333

((

))

RAI ARCB #3

Background:

In Regulatory Guide 1.183 Appendix B, Assumptions for Evaluation the Radiological Consequences of a Fuel Handling Accident Section 2 Water Depth, a minimum water level of 23 feet is required to assume a DF of 200. If the depth of water is not 23 feet, the decontamination factor will have to be determined on a case-by-case method.

In section 2.3 Pool Decontamination Factor (DF) Model of the document CALCULATION NO.

JAF-CALC-RAD-04410 as provided in Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis Dated August 31, 2023, it is stated that the spent fuel pool water level is normally maintained at about 21 feet 7 inches over the top of irradiated fuel assemblies seated in the spent fuel pool storage rack. It is also stated that an effective DF of 200 is used in this analysis.

Current licensing basis provides a drop height of 2 feet before being stopped by the stored assemblies, and 81 fuel rods being damaged. The assumption of 81 rods being damaged over the SFP as opposed to the 125 damaged fuel rods over the reactor vessel is based upon drop height. Current licensing basis allows an assumed increase in DF, from a calculated 172.75 with 21 feet 7 inches of water, to a DF of 200 with the assumption of 35% less fuel rods being damaged in an event in the SFP.

The discussion for SFP DF in Section 2.3 Pool Decontamination Factor (DF) Model, points to Assumption 4.2 in the LAR. This assumption does not address number of fuel rods damaged in an accident in the SFP.

Question:

Please provide on the docket the justification for utilizing a DF of 200 for a fuel handling accident in the SFP. Specifically, please justify the use of a DF of 200 since the assumed number of fuel rods damaged has changed from CLB. Include in the discussion the drop height with the new mast, and the change in fuel rods damaged in this analysis (as opposed to the current licensing basis). Please modify application to note that the assumed SFP height of 21 feet 7 inches is the minimum SFP height according to technical specification 3.7.7 as opposed to normal SFP height.

Response to Request for Additional Information Page 5 of 5 Fuel Handling Accident Analysis Docket No. 50-333 Response to RAI ARCB #3 FitzPatricks Technical Specification 3.7.7 outlines that the spent fuel storage pool water level must be maintained greater than 21 ft and 7 inches. The utilization of a DF of 200 with 21 feet and 7 inches of water was first employed during FitzPatricks initial licensing implementation of AST in the FHA (ML021620506 from June 7, 2002) and acknowledged in the associated SER (ML022350228 from September 12, 2002). In that letter, it is discussed that the calculated DF for 21 feet 7 inches of water is 172.75. However, an assembly dropped in the spent fuel pool travels a distance of only 2 feet before being stopped by the stored assemblies. The reduced energy of impact would result in less fuel rods being damaged. Therefore, the reduced source term from less damaged fuel rods would more than offset the increased halogen release from the water surface from this lower DF.

For this submittal, the same argument and justification is being employed. Based on the information provided in the GEH proprietary report 002N5644, Rev. 1, a GNF2 fuel bundle with the NF500 fuel mast experiencing a drop of 2 feet would damage ((

)). Similarly, a GNF3 fuel bundle with the NF500 fuel mast experiencing a drop of 2 feet would damage ((

)). Based on the far greater reduction in fuel damage then whats gained by increasing the DF to 200, it is conservative to maintain the assumption of a DF of 200 with no reduction to the FHA source term