SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-1 2.3 METEOROLOGY 2.3.1 REGIONAL CLIMATOLOGY 2.3.1.1 General Climate The climate of east central Pennsylvania is on the border of Koeppens' "snow forest" and temperate rainy climate (Ref. 2.3-1). There is considerable snow during the winter and relatively hot humid summers with precipitation distributed evenly throughout the year.

This region is repeatedly affected by interactions between warm, moist maritime tropical air masses and cool, dry continental polar air masses. The polar air masses are the dominant influence in the winter while tropical air masses predominate in the summer. Maritime polar air masses are also common in a highly modified form from the Pacific or directly from the North Atlantic. The North Atlantic air masses which are cool and humid are usually associated with approaching warm fronts and "back door" cold fronts.

The weather systems which affect east central Pennsylvania are generally of non-tropical origin.

The storm tracks of less than 7% of all North Atlantic tropical cyclones enter Pennsylvania T:\SSES810\Nuclear Regulatory Affairs\Licensing Documents\# LDCNs Ready for Review\LDCN 5717 (Ref. 2.3-2). Systems which produce precipitation are divided into 3 groups. Cold fronts, trailing from cyclones passing to the north, occurring throughout the year, are the primary source of summer precipitation in the region. A second type of disturbance that produces precipitation in this area is the coastal low, originating in the Gulf of Mexico or in the Cape Hatteras region, which moves NNE along the coast. The greatest snowfalls in east central Pennsylvania are associated with this type of system. Major extra-tropical cyclones originating in the Gulf of Mexico, Texas Panhandle, or the lee of the Rockies which move northeast or east frequently give the region light or moderate snowfalls and rain. Tropical cyclones occasionally affect the region but very rarely retain hurricane force so far inland. Record rainfalls are often associated with decaying tropical cyclones.

Tornadoes seldom occur in Pennsylvania and those which cause severe damage or loss of life are rare.

The monthly average winds are westerly (Ref. 2.3-3). The wind in the region is constrained by the general direction (ENE-WSW) of the ridge and valley topography. Wind speeds in the region are light to moderate with monthly averages less than 10 mph.

Average temperatures range between 72oF in the summer and 25oF in the winter with extremes of 101oF and -21oF. Relative humidity is usually greater than 50%, often greater than 85%

(Ref. 2.3-3a).

The Wilkes-Barre Scranton Airport at Avoca, Pennsylvania approximately 45 km northeast of the site, is the nearest National Weather Service Station. Based upon "STAR" summaries for the years 1971-1975 neutral stability conditions predominate at Avoca with Class C, D, and E occurring approximately 9, 59, and 13 percent of the time, respectively (Ref. 2.3-4).

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-2 The diffusion climatology of the region is generally good due to the prevalence of moderate wind speeds at most times. Occasional stagnant situations occur during the late summer and autumn when anticyclones stall over the northeastern U.S. It should also be noted that the plants location in the Susquehanna Valley can cause different stability conditions than those found concurrently at the top of the surrounding mountains or plateaus.

2.3.1.2 Regional Meteorological Conditions for Design and Operating Bases 2.3.1.2.1 Hurricanes Hurricane winds seldom affect the area because of the rough terrain and the distance of the region from the ocean. Recently, Hurricane Agnes (June 1972) resulted in the worst natural disaster to hit the region because of the excessive precipitation it produced. Record flooding was recorded along the Susquehanna River. At Wilkes-Barre, 25 miles upstream from the site, the river crested on June 24 at a height of 40.91 feet, almost 8 feet above the previous record. Rainfall at Avoca, Pennsylvania for the period of Hurricane Agnes (June 21-22) was 3.10 inches. On August 18-19, 1955 the rainfall associated with Hurricane Diane was 4.58 inches (Ref. 2.3-3).

A tabulation of North Atlantic tropical cyclones with centers passing within 75 and 150 nautical miles of the Susquehanna site is presented in Table 2.3-1. The significance of these two distances is that points that lie within 75 to 150 nautical miles from the center of a hurricane may receive some heavy rainfall whereas points that lie between 0 and 75 nautical miles from the center of a hurricane are very likely to receive heavy rainfall. The frequency and recurrence interval of hurricane centers passing within 75 and 150 nautical miles is, respectively, 0.08 per year with an interval of 12 years, and 0.20 per year with an interval of 5 years (Ref. 2.3-2).

2.3.1.2.2 Tornadoes The incidence of tornadoes in the site area is very low. Between the years 1950 and 1973 only 38 tornadoes were reported within 50 miles of the site. Tornado activity is at a maximum during the summer months with most tornadoes occurring in the late afternoon or evening. Figure 2.3-1 is a histogram for the years 1953-1962 showing tornado frequency by month, hour, and intensity within a 3° by 3° square which is centered on the site. The intensity categories are based on the Fujita tornado intensity classification (Ref. 2.3-5). From Figure 2.3-1 it can be seen that maximum tornado occurrence is in the summer. Diurnally, tornado frequency reaches a maximum during late afternoon, shortly after the period of greatest instability. For the period from 1950-1997, there were 5 tornadoes officially reported in Columbia County and 13 tornadoes officially reported in Luzerne County (Ref. 2.3-5a).

2.3.1.2.3 Thunderstorms Thunderstorms in the area are usually of brief duration and concentrated in the warm months.

They are responsible for most of the summertime rainfall which normally averages around 3.7 inches per month at Avoca, Pennsylvania. Based on a 19-year average at Avoca the mean number of "days with thunder heard" is 30 (Ref. 2.3-3). A monthly breakdown of the mean number of thunderstorm days that is representative of the site is shown in Table 2.3-2.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-3 2.3.1.2.4 Lightning There is neither documentation nor direct measurement of the occurrence of lightning other than the observation of associated thunder. Local climatological data tabulated by the National Weather Service (Ref. 2.3-3) does not provide information regarding the incidence, severity, or frequency of lightning occurrences. A thunderstorm can usually be heard unless the lightning causing the thunder is more than 15 miles away; therefore, thunder incidence can presumably be used to confirm the presence of some lightning.

The number of lightning strikes per square mile per year has been established by Uman (Ref. 2.3-6). The combined results of several studies summarized by Uman indicate that the number of flashes to the ground per square mile per year is between.05 and.80 times the number of thunderstorm days per year. The mean number of days with thunderstorms probably overestimates the actual occurrence of cloud-to-ground lightning since some thunderstorms probably contain only cloud-to-cloud lightning. Therefore, if the annual thunderstorm frequency at Avoca is used (30 days), the number of ground lightning strikes is between 2 and 24.

2.3.1.2.5 Hail Hail in the site region sometimes falls from severe thunderstorms. Because hail falls in narrow swaths, only a small fraction of occurrences is recorded at regular reporting stations. The average annual number of days with hail at a point in the area is 23 (Ref. 2.3-7). The occurrence of large hail (greater than 3/4 inch diameter) averages 1 or 2 occurrences annually. According to Pautz (Ref. 2.3-7) the number of hailstorms with hail 3/4 inch and greater by 1-degree longitude-latitude squares was about 5 in the vicinity of the site for the period 1955-1967. For Avoca, Pennsylvania from 1973-75 there was one hailstorm each June, and one each in July of 1973 and 1974. In 1975 there was also one hailstorm in August and one in October. There were no occurrences of hail recorded in 1976 at Avoca (Ref. 2.3-3).

2.3.1.2.6 Extreme Winds Strong winds occur in Pennsylvania as a result of the remnants or outer fringes of tropical systems, occasional hurricanes, thunderstorms, and tornadoes. The following is the fastest mile of wind and its associated direction, by month, at Avoca, Pennsylvania (1955-1976) (Ref. 2.3-3).

FASTEST MILE OF WIND Month mph Direction Month mph Direction January 43 SE July 42 NW February 60 W

August 50 NE March 49 S

September 38 SW April 47 NW October 38 E

May 40 NW November 45 S

June 43 W

December 47 SW The 50-year and 100-year mean fastest mile wind speeds for the site area are 75 miles per hour and 80 miles per hour, respectively (Ref. 2.3-8). According to Pautz, there were 8 windstorms 50 knots and greater for the 1 degree latitude-longitude square that includes the Susquehanna site for the period 1955-1967 (Ref. 2.3-7).

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-4 The gust factor was calculated as 1.3 from the following equation (Ref. 2.3-9).

)

V 00256

(.

K G

G 2

z f

F=

Where GF is the gust factor to be applied to the fastest mile wind speed at 10 m above the ground.

KZ is the velocity pressure coefficient at 10 m (.52).

V is the speed of the 100 year return period fastest mile wind (80 mph).

Gf is the velocity pressure (11.5).

2.3.1.2.7 Freezing Rain Freezing rain can occur in the late fall, winter, and early spring. During the 50 years from 1919-1969 there were 4 occurrences of ice accumulation of 1 inch. The probability of an ice storm accumulating at least 1 inch in any year in the Northeast region of the U.S. is.24 (Ref. 2.3-10). At Avoca, Pennsylvania from 1973-1976 there were 57 days with freezing rain, 21 in January and 18 in February. There were nine occurrences each in March and December during that period. The duration of these phenomenon never exceeded 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and was usually less than 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> (Ref. 2.3-11).

2.3.1.2.8 Duststorms Because the soil in Pennsylvania is usually moist all year the likelihood of a duststorm is small (Ref. 2.3-12). There were no recorded duststorms for the period 1972-1976 at Avoca, Pennsylvania (Ref. 2.3-11).

2.3.1.2.9 High Air Pollution Potential The meteorological conditions that are generally conducive to high air pollution potential are light winds, stable boundary layers, and near surface based inversions. Holzworth (Ref. 2.3-13) studied the episodic occurrence of several limited dispersion conditions at each of 62 upper air stations in the United States. He considered episode durations of at least 2 days and at least 5 days. Twelve different limited dispersion conditions were used to define each episode. Each condition was defined by a different combination of mixing height and wind speed. Intermediate limiting conditions of mixing heights less than or equal to 1500 m and wind speeds 4.0 m sec-1 or less with no significant precipitation during episodes lasting at least 2 days are of interest because such criteria have been used as criteria by the National Pollution Potential Forecasting Program (Ref.

2.3-13). The approximate number of episode-days at the site area is 25 in 5 years. This is much less than in the western half of the country and less than most of the East. Table 2.3-3 presents a summary of the data at stations presented by Holzworth which are closest to the site. Days with high air pollution correlate to days with minimum low level atmospheric mixing and dispersion.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-5 2.3.1.2.10 Snowpacks Severe snowstorms are not frequent in the area. Snowfall averages between 40 and 50 inches a year in the site region. At Avoca, Pennsylvania the extreme 24-hour snowfall was 20.5 inches in November, 1971 but the greatest snowfall of record was 21.1 inches over a 29 hour3.356481e-4 days <br />0.00806 hours <br />4.794974e-5 weeks <br />1.10345e-5 months <br /> period in January, 1964. The extreme seasonal snowfall was 76.8 inches in 1969-1970 (Ref. 2.3-3).

The 100 year mean recurrence interval snow load on the ground is 122.02 kgm-2 (25 lbs ft-2)

(Ref. 2.3-9). The 100 year mean recurrence snow depth for Avoca, Pennsylvania is 28.6 inches (Ref. 2.3-15).

Assuming the maximum probable winter precipitation falls on top of the 100 year mean recurrence interval snowload yields a conservative estimate of the maximum probable combined snowload.

Assuming that the 100 year mean recurrence interval snowload occurs during January, which has the lowest average monthly temperature and the greatest snowfall of record, the weight of the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> probable maximum winter precipitation for January must be added to it. The weight of the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> probable maximum winter precipitation for January is 287.0 kg m-2 (59 lbs ft-2)

(Ref. 2.3-14). Thus, the weight of the probable maximum combined snowload at ground level is 409.02 kg m-2 (84 lbs ft-2).

2.3.1.2.11 Design Basis Tornado The development of a Design Basis Tornado (DBT) follows the premise that the probability of occurrence of a tornado exceeding the DBT should be on the order of 10-7 per year (Ref. 2.3-16).

The 10-7 per year design tornado was determined for a 3o latitude by 3o longitude area encompassing the site. The tornado path lengths and widths in the area of interest were used in the probable calculation.

The first step in the procedure is the computation of the geometric probability which is given by the following equation:

)

A

/

a

(

n P s =

(Eq. 2.3-1) where Ps is the mean annual probability of a tornado striking a point, n is the mean number of tornadoes occurring within the area A per year, and "a" is the mean path area determined from the log-normal distribution.

The design basis wind speed is one which satisfies the condition PsPi < 10-7 yr-1 where Pi is the acceptable intensity probability and is determined from the plot of cumulative F-scale intensity frequencies on log-probability paper. The F-scale is an estimate of tornadic wind speed range based upon damage inspection and has been compiled for the years of 1971 and 1972 (Ref. 2.3-17).

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-6 The average rate of pressure drop within the radius of maximum winds is determined by:

(Ref. 2.3-19) r 2

pT

=

dt dp m

(Eq. 2.3-2)

Where:

p

=

pressure change t

=

time T

=

translational speed rm

=

radius rotational wind speed = 150' The total pressure drop, p, is determined by the application of the cyclostrophic wind equation:

dr r

m V

A 2

=

dr r

m 2

r o

r o

(Eq. 2.3-3) where Vm is maximum rotational wind speed and is the density of air (1 x 10-3 gm/cm3).

The region from which tornado path length and width statistics were selected was between 75o to 78o longitude and 40o to 43o latitude; approximately centered on the site location. Of the 63 tornadic events thirty four values of path length and width were found for the period 1950-1973 based upon the National Severe Storms Forecast Center's tornado tape.

The geometric probability is calculated by substituting the following parameters into Equation 2.3-1:

Where, a

=

0.388 mi2 A

=

32,265 mi2 n

=

63/24yr = 2.625 yr-1 Ps

=

3.157 x 10-5 yr-1 and Pi

=

3.168 x 10-3 yr-1 This results in a design wind speed of 260 mph for a probability of 10-7 yr-1 (Ref. 2.3-19). The value of "a" is conservative in comparison with a value of.26 mi2 for the combined states of Pennsylvania and West Virginia and.37 mi2 for New York state for the period 1953-1972 (Ref. 2.3-18). Although the value of "a" was based on only 34 of the 63 tornadoes it was conservatively assumed that all 63 tornadoes had a mean path area of 0.388 mi2. In this region, the highest tornadic intensity was F 2 or 157 mph. Thus, the 260 mph design wind speed is conservative with respect to the local historical record.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-7 The rate of pressure drop and the total pressure drop are determined directly from Equations 2.3-2 and 2.3-3, respectively. The maximum translational wind speed was interpolated from the Region II and Region III values (Ref. 2.3-16). The design basis parameters calculated for the Susquehanna Steam Electric Station are (Ref. 2.3-19):

Total Rotational Maximum Maximum Wind Translational Wind Speed Speed Speed 260 205 55 Minimum Total Rate of Translational Pressure Pressure Speed Drop Drop 5 mph 1.9 psi 0.9 psi/sec The actual design basis parameters that were used for the Susquehanna design are presented in Section 3.3.

2.3.1.2.12 Ultimate Heat Sink An analysis of the ultimate heat sink is presented in Section 9.2 of the FSAR.

This analysis is based on 11 years of meteorological data collected on site as well as 34 years of meteorological data collected at Avoca Airport near Scranton, Pennsylvania.

A computer-aided search was done for both data bases to determine two periods of time for use as the Ultimate Heat Sink design meteorology. One was chosen such that the ability to cool sprayed water is minimized (minimum heat transfer case). The other was chosen such that the potential for water loss is maximized (maximum water loss case). The selection of this meteorology is discussed further in Subsections 9.2.7.3.5 and 9.2.7.3.7.

2.3.2 LOCAL METEOROLOGY 2.3.2.1 Normal and Extreme Values of Meteorological Parameters 2.3.2.1.1 Wind The following data sources were used as the basis of this section: long-term data from Wilkes-Barre Scranton Airport at Avoca, Pennsylvania (Ref. 2.3-3), four years of data (1973-1976) collected at the 31.5 and 300 feet levels and five years of data (1999-2003) collected at the 10 m and 60 m levels of the Susquehanna meteorological tower located at the site.

The Avoca station is located about 30 miles northeast of the Susquehanna site. It is reasonably representative of the site due to their close proximity to one another and similar topography.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-8 Table 2.3-6 is a summary of long-term wind data for Avoca (Ref. 2.3-3). It shows the annual average speed is 8.4 miles per hour and the prevailing direction is southwest. The monthly average wind speeds are greatest in the spring (9.6 mph in April) and lowest in the late summer (7.2 mph in August). The prevailing wind direction is SW or WSW for every month except March when it is NW. Table 2.3-7 is a similar summary for the on-site data.

Lower level (31.5 feet) data from the Susquehanna site for the 4 year period show an average wind speed of 4.45 mph (1.99 m/sec). The prevalent direction over the 4 years was the WSW closely followed by W. The ENE direction presents a secondary maximum in frequency of occurrence.

Tables 2.3-8 through 2.3-16 provide wind persistence data for the Susquehanna site on an annual basis, at the lower level, for each stability class, all classes combined, and all stable classes.

The joint frequencies of wind speed, direction, and stability at both the lower and upper levels were updated in 2005 to use the 5 year period (1999 - 2003) are found in Tables 2.3-75 through 2.3-91.

The overall southwest to northeast orientation of topographic ridge lines in the SSES vicinity has a profound influence on the low level winds. At Avoca, PA, the mean annual wind direction is from the southwest. At the SSES site, the predominant wind directions measured at the 10-meter level are from the east-northeast and from the southwest. The Susquehanna River Valley orientation effectively funnels a localized, low level wind flow up or down the valley. The river valley environment is also favorable for stable meteorological conditions in the lowermost portion of the atmosphere characterized by little to no wind and the presence of fog. This is most prevalent during the overnight hours. The river valley influence on atmospheric stability at the SSES site makes stability conditions unique and often quite different when compared to stability conditions at Aroca.

2.3.2.1.2 Temperature and Atmospheric Water Vapor Table 2.3-17 presents the long-term monthly average and extreme temperatures for Avoca, Pennsylvania. July is the warmest month with a long-term average maximum temperature of 82.2oF, an average minimum temperature of 61.8oF, and a mean of 72.0oF. The coolest month is January, having an average temperature range of 32.3oF to 17.7oF and a mean temperature of 25.0°F. The average annual diurnal variation is 18.1oF (Ref. 2.3-3a).

East Central Pennsylvania experiences the temperature extremes associated with mid-latitude traveling low pressure disturbances. The temperature extremes at Avoca, Pennsylvania are 101oF in July of 1966 and -21oF in January, 1994. Average Avoca, Pennsylvania dewpoint and relative humidity data are contained in Table 2.3-18 (Ref. 2.3-3a).

At the Susquehanna site during the period 1973-1976 dry bulb temperatures ranged from a high of 34.3oC (94oF) to a low of -20.9oC (-6oF). The average temperature was 9.3oC (49oF). July had the highest average temperature 20.3oC (69oF) while January had the lowest with -2.1°C (28oF). The average wet bulb temperature was 6.9oC (44oF) with the months of July and August averaging 17.7oC (64oF). The average relative humidity was 70% with the month of August averaging 82%.

A summary of the site data is presented in Tables 2.3-19 through 2.3-32.

For the period of 1981-1996, the maximum SSES average hourly temperature of 37.8°C (100°F) occurred on July 16, 1996. The minimum average hourly temperature at SSES for this period was

-30.8°C (-23.1°F) on January 21, 1994.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-9 2.3.2.1.3 Precipitation The region surrounding the Susquehanna site has a moderately moist climate averaging just over 36 inches of rainfall per year spread quite evenly over all months of the year. There is a slight maximum during the summer when there is a greater effect of tropical air masses and thunderstorms. The average monthly and maximum 24-hour precipitation for Avoca, Pennsylvania are given in Table 2.3-33. The greatest 24-hour rainfall amount reported at Avoca, Pennsylvania was 6.52 inches in September 1985, associated with the remnants of Hurricane Gloria. The greatest 24-hour snowfall, 20.5 inches occurred with the Thanksgiving Day storm of November 24-25, 1971, but the greatest snowfall of record was 21.1 inches over a 29 hour3.356481e-4 days <br />0.00806 hours <br />4.794974e-5 weeks <br />1.10345e-5 months <br /> period on January 12-13, 1964 (Ref. 2.3-3).

Table 2.3-34 presents the expected rainfall by duration and recurrence intervals for the area around the Susquehanna site as compiled by the National Weather Service (Ref. 2.3-20). The probable maximum precipitation for various rainfall duration in East Central Pennsylvania by area size is presented in Table 2.3-35. Assuming 10 square miles is most representative of the power plant site, the probable maximum rainfall ranges from 25 1/2 inches in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to 36 1/2 inches in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (Ref. 2.3-21). The rainfall rate distribution curves are presented for Scranton, Pennsylvania in Figure 2.3-2. The 100 year return period rainfall rate is 2.5 inches for a 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> period.

Table 2.3-36 presents the summary of on-site precipitation data for the 4 year period. The site averaged a total of 47.83 inches annually with the greatest occurring in September (7.54 inches) and the minimum in December (2.21 inches). Data on the rainfall frequency, and duration of precipitation for the Susquehanna site are presented in Tables 2.3-37 through 2.3-49 by month and for the 4 year period. Precipitation wind roses are presented by month and for the total period in Tables 2.3-50 through 2.3-62.

2.3.2.1.4 Fog and Smog At Avoca, Pennsylvania between the years of 1973-1976 there was an average of 86 days of haze and smoke reported. Most of the days were in the summer months. Over the same period, the three hourly observations of fog averaged 250 for a year. Fog was usually observed with rain or snow and most often in the early fall months. The average number of days with heavy fog for the period was 21. Table 2.3-63 presents the heavy fog occurrences at Avoca, Pennsylvania for recent years. Based on National Weather Service data from Avoca, Pennsylvania from a 22 year period, heavy fog (visibility 1/4 mile or less) occurs 24 times per year. No on-site data on fog, or haze, is available.

2.3.2.1.5 Stability Atmospheric stability at the Wilkes-Barre Scranton airport based on STAR data for the period 1971-1975. The STAR data for the period 1971-1975 were selected because they represented the most recent five year period which was available at the time and the fact that a five year period of record is generally regarded as being representative of long-term meteorological conditions. The 1971-1975 period also shows the prevailing direction to be from the SW at an average speed of 8.5 mph. STAR data for the fire year period 1960-1964 also show that the prevailing wind direction is from the SW at an average speed of 6.7 mph. For a 22-year period of record the prevailing wind

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-10 direction was SW at an average speed of 8.4 mph. The relative stability distribution of these two five-year periods are:

Pasquill Stability Class 1960-64 1971-75 A

0.41 0.32 B

5.27 4.84 C

10.04 8.92 D

54.27 58.64 E

12.36 13.09 F

13.05 11.16 G

4.60 3.01 The seasonal occurrence of E and F stabilities are given below for the 1971-75 period:

SEASONAL OCCURRENCE (%) OF E AND F STABILITIES Winter Spring Summer Autumn E

12.3 12.0 14.9 12.9 F

8.5 8.9 14.0 13.0 Tables 2.3-64 to 2.3-71 are annual stability summaries by wind speed and direction from Avoca, Pennsylvania data for the years 1971 through 1975 (Ref. 2.3-4). The analytical technique for classifying stability is based upon three hourly observations and is dependent primarily upon net solar radiation and wind speed. For the entire period neutral and sightly stable most often occur.

The on-site stability summaries by wind speed and direction are presented in Tables 2.3-75 through 2.3-91.

Studies by Holzworth (Ref. 2.3-33) indicate that for Northeastern Pennsylvania unstable conditions (A, B, C) occur 16-25 percent of the time while neutral (D) conditions prevail 46-55 percent of the time and stable conditions (E, F, G) occur 26-35 percent of the time. For the 4 year period 1973-1976 the on-site data showed the following stability frequencies: Pasquill class A-16 percent, B-7.6 percent, C-4.2 percent, D-30.8 percent, E-26.2 percent, F-10.5 percent, G-4.5 percent. This indicates that the site is prone toward stable conditions (41.2%) rather than neutral conditions (30.8%).

Representative mixing heights on a seasonal and diurnal basis obtained by averaging data from Albany, and New York, New York; Pittsburgh, Pennsylvania; and Washington, D.C. (Ref. 2.3-13) are presented in Table 2.3-72.

Low level atmospheric stability is influenced by insolation. The relatively high latitude of the SSES site (approximately 41° North) has a profound impact on the length of daylight. At the winter solstice (around December 21), the time elapsed between sunrise and sunset is 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />, 11minutes. At the summer solstice (around June 21), the time elapsed between sunrise and sunset is 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />, 10 minutes, or a difference of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> (Ref. 2.3-13a).

2.3.2.2 Potential Influence of the Plant and its Facilities on Local Meteorology The expected characteristics and effects of water vapor plumes entering the atmosphere arising from the operation of two natural draft cooling towers have been evaluated.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-11 The characteristics and effects associated with cooling tower operation were determined in terms of:

a)

Monthly and annual frequency distributions of plume length with respect to distance and direction out to 20,000 ft.

b)

Monthly and annual frequency distributions of ground level plumes (fogging) with respect to distance and direction.

c)

Monthly and annual frequency distributions of ground level plumes accompanied by subfreezing temperatures (icing) by distance and direction.

d)

Monthly and annual frequency distribution of increases in relative humidity and temperature with respect to distance and direction.

Simulations were obtained from a computerized diffusion model that simulates vapor plume length and the occurrence of ground level fogging or icing. The Gaussian plume theory distribution is assumed with buoyancy approximated by a dry plume rise equation. The computer program utilizes cooling tower performance data and on-site meteorological observations for 1976 (ambient temperature, dew point, wet bulb temperature, wind velocity, and atmospheric stability) to determine the downwind dispersion of water vapor at plume centerline and ground level.

The year 1976 was selected because it was the most conservative year with respect to atmospheric dispersion conditions of the four years of on-site data. It is also conservative with respect to long-term atmospheric conditions.

The model used was developed by Dames & Moore and has been used in previous submittals to NRC. The model was presented by Bowman, W. Alan and Biggs, W. Gale in their paper entitled "Meteorological Aspects of Large Cooling Towers" presented at a APCA Conference in Miami, Florida in June, 1972. The height at which each meteorological measurement input to the model was taken is given below:

Wind Speed..........................................300 ft.

Wind Direction......................................300 ft.

Temperature.........................................31.5 ft.

Relative Humidity.................................31.5 ft.

Stability.................................................300 ft. - 31.5 ft.

Generally, the longer plume lengths occur more frequently in the winter months in the early morning hours when the relative humidities are high. The visible plumes were computed to extend laterally beyond 20,000 feet (4 miles) approximately 30 percent of the time in the sectors of maximum occurrence (NE and ENE) and 70 percent for all sectors. Visible plumes occurred least frequently in the WNW through NNW sectors with computed plume lengths beyond 4 miles occurring with a frequency of 2.1 percent to 2.5 percent annually. There were no computed occurrences of ground fogging. Relative humidity increases of 2.5 percent above ambient did not occur.

No occurrences of icing were computed. Likewise, no computed increases in surface temperature of 0.5oC or greater were projected in the study sample.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-12 In conclusion, the frequent (70%) long visible plumes are the primary meteorological effects to be experienced from the operation of the Susquehanna cooling towers. There is no fogging or icing expected. The inducement of other weather modification effects such as rainfall augmentation is unlikely due to the small percentage increase in atmospheric moisture introduced into the already moisture laden environment.

Further details of this analysis are provided in Subsection 5.1.4 of the Environmental Report.

The topography surrounding the site consists of ridges and valleys. Figure 2.2-21 shows the topography within a 5 mile radius of the site. The cross-sections of elevation centered on the plant along the 16 cardinal directions to a distance of 50 miles are shown in Figures 2.3-4-1, 2.3-4-2, 2.3-4-3, 2.3-4-4, 2.3-4-5, 2.3-4-6, 2.3-4-7, and 2.3-4-8.

2.3.2.3 Local Meteorological Conditions for Design and Operating Bases All local meteorological and air quality conditions used for design and operating basis considerations and their bases, except for those conditions referred to in Subsections 2.3.4 and 2.3.5, are provided in Subsections 2.3.1.2.1 through 2.3.1.2.11. Current site meteorological information is documented on a regular basis in the SSES Annual Effluent and Waste Disposal report.

2.3.3 ON-SITE METEOROLOGICAL MEASUREMENTS PROGRAM The on-site meteorological program is designed to provide a complete climatology of the site area, but most importantly to provide dispersion climatology for use in safety planning of radioactive effluent releases and as a means of determining the appropriately conservative meteorological parameters to be used in estimating the potential consequences of hypothetical accidents.

Analysis of collected meteorological data permits an assessment of the diffusion parameters characteristic of the site.

2.3.3.1 Location and Description of the Tower Site The site is about 8 km (5 mi.) ENE of Berwick, Pennsylvania. The primary meteorological tower, commonly referred to as the Primary Meteorological Tower, a 200 foot steel framed tower, is located about 340 m to the southeast of the cooling towers. The area is generally level, increasing slightly in elevation to the north and west. South and east of the tower the topography slopes down towards the Susquehanna River. Vegetation in the immediate vicinity is low weeds with some deciduous trees in a gully to the south. The deciduous trees are approximately 40 feet in height and are approximately 100 feet from the tower. In 1994, an ash facility was placed approximately 185 feet north of the Primary Meteorological Tower. The maximum height of this structure is approximately 30 feet.

In November 1972 three meteorological instrumentation platforms were constructed. The primary tower was erected on the Susquehanna nuclear power station site at the same altitude as the station (approximately 650' msl) between the station and the Susquehanna River. The purpose of the primary tower is to estimate the stability and movement of the air layer into which the effluent from the facility could be released as required by NRC Regulatory Guide 1.23 (Ref. 2.3-22). In addition to the primary tower, 75 foot and 10 foot instrumented poles were erected at site vicinity.

The 75 foot tower was at 1115' msl on a hill to the NW of the station and the 10 foot tower was below the station towards the river at 500' msl. The purpose of the 75 foot pole was to provide

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-13 sensing of wind, temperature, and humidity parameters at an elevation comparable to the elevations of the cooling tower plumes. The 75 foot tower was removed on January 14, 1974 due to construction requirements. The data from the primary meteorological tower provides sufficient information for the cooling tower analysis. The 10 foot tower in the valley below the station, was removed on November 14, 1975, after three years of data had been collected. Figure 2.3-5 presents a schematic of the sites and the instrumentation.

In compliance with the requirements of NUREG-0654 a backup meteorological tower was erected in 1982. This tower is commonly referred to as the Backup Tower. The tower is a 30-foot instrumented utility pole located northeast of the station and across from the Training Center. The purpose of the backup tower is to provide sensing of wind parameters at the 10-meter level.

Additionally, in 1985 two supplemental towers were installed in the river valley near the station to provide additional data to more accurately model the effects of surrounding terrain on atmospheric dispersion and transport. One tower is located UPRIVER approximately 1.2 miles NNE of the station off Route 11 towards Shickshinny; the second tower is located DOWNRIVER approximately 3.6 miles SW of the station off Route 93 just east of Nescopeck. Meteorological validation of the UPRIVER supplemental tower data was terminated on October 1, 1994 and the UPRIVER supplemental tower equipment was abandoned in place at that time.

Both The DOWNRIVER tower measures wind speed, wind direction and sigma theta at the 10 meter level. The DOWNRIVER tower also measures temperature at a height of approximately 6.6 feet.

The meteorological data collected from the DOWNRIVER tower continues to be validated and is used only to support assessment and restoration efforts in the event there is an accidental release of radioactive material from SSES.

2.3.3.2 Types of Measurements Made The parameters which are monitored for conformance to NRC Regulatory Guide 1.23 (Ref. 2.3-22) commitments are wind speed, wind direction, temperature, delta temperature, dewpoint temperature and precipitation. Delta temperature accuracy criteria is monitored for conformance to AEC Safety Guide 123 (Ref. 2.3-22a). The parameter, heights, and number of sensors installed at the Susquehanna site are listed in Table 2.3-73.

2.3.3.3 Description of Instruments The wind sensor consists of a 3 cup anemometer and coupled drive shaft that responds to wind and rotates a multi-section light beam chopper. Rotation of the chopper alternately masks and exposes a phototransistor to a miniature light source. The phototransistor responds to the light passing through the chopper wheel and generates an electrical output which has a frequency proportional to wind velocity. This signal is then sent to a translator for further conversion. The accuracy required for the wind speed measurement is +/-0.5 mph for speeds less than 5 mph and

+/-10% for speeds above 5 mph. This requirement is met by the instrumentation used on the primary tower.

The wind direction sensor is comprised of a counterbalanced lightweight vane coupled to a precision potentiometer assembly by the drive shaft, causing the potentiometer wiper to directly follow movements of the wind vane. The position of the vane is sensed by the potentiometer and is sent to a translator as a DC voltage. The accuracy requirement for the wind direction

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-14 measurement is +/-5° of azimuth with a starting threshold of less than 1 mph. This requirement is met by the instrumentation used on the primary tower.

On the primary tower the temperature measuring system consists of multiple thermistor composite sensors. Two sensors are mounted in motor aspirated radiation shields at each of the 10 meter and 60 meter levels. The thermistor sensors are connected in a resistive network and powered by a D.C. voltage to produce a voltage that varies approximately linearly with temperature as a translator output. Each translator produces two channels of output; one channel of one translator provides the ambient temperature output for 10 meters and a second, comparator channel provides differential temperature output derived from one 10 meter sensor input and one 60 meter sensor input. The two separate sets of 10 meter and 60 meter sensors provide one 10 meter ambient temperature measurement and two difference temperature measurements between the 10 meter and 60 meter levels.

Accuracy required for the ambient temperature measurement is +/-0.5°C. This requirement is met by the instrumentation used at the primary tower.

Accuracy required for the temperature difference measurement is +/-0.1°C/50m. This requirement is met by the instrumentation used on the primary tower.

The dewpoint temperature is measured on the primary tower with bifilar wire electrodes wound on a cloth sleeve which covers a hollow tube or bobbin. The bifilar electrodes are not interconnected, but depend on conductivity of the atmospherically moistened lithium chloride treated bobbin for current flow. As the moisture content in the air increases, the lithium chloride absorbs water vapor and becomes conductive. Current then begins to flow between the electrodes energized by low AC voltage, and heats the bobbin. Some of the moisture is thereby evaporated until an equilibrium temperature is reached on the bobbin. The equilibrium temperature is related to the dewpoint temperature of the air. A thermistor sensor is mounted inside the bobbin to measure the cavity temperature which is converted in analog outputs, representing dewpoint temperature by a electronic temperature translator. The accuracy required for the dewpoint temperature measurement is +/-1.5°C. This requirement is met by the instrumentation used on the primary tower.

On the 10 meter level of the primary tower a motor aspirated temperature and dewpoint shield houses two thermistor sensors, and the dewpoint sensor. At the 60 meter level two motor aspirated temperature shields each houses a thermistor sensor.

Precipitation is measured in a Tipping Bucket Rain Gauge at the primary tower site. This is a remote reading gauge which produces a signal proportional to total rainfall. Precipitation is collected in a collection opening and is funneled to the two buckets of the tipping mechanism. As one bucket fills with water, the weight causes it to lower, tip, and empty while the bucket on the opposite side is simultaneously raised to receive additional water. Each tipping phase causes a momentary switch closure. This closure actuates a digital counter directly proportional to accumulated rainfall. The required accuracy for the rainfall measurement is +/-10% of the total accumulated catch for amounts in excess of 0.2 in. This requirement is met by the instrumentation used on the primary tower.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-15 Vertical diffusion coefficients are computed from the vertical temperature differences. Wind sigma standard deviation of wind direction is measured at the 10 and 60 meter levels and used to compute horizontal diffusion coefficients. Sigma theta calculations based on wind direction measurements are used as a backup to temperature readings to monitor atmospheric stability.

The outputs of all sensors are handled by a modular translator system designed to convert the sensor outputs into a standardized voltage/current output. Each input channel is allotted one circuit designed for a particular sensor, such as wind speed, wind direction, or temperature, etc. The necessary signal processing and scaling is contained in each circuit to provide an electrical output of uniform range. There are two outputs from each circuit. One low voltage output is directed to a data logger accessible via telephone modem and a second low voltage output to a telemetry transmitting system which directs a specific frequency/parameter signal to telemetry receiving device in the control room which converts this signal to a 4 to 20 ma output which then inputs to an appropriate recorder in the main control room.

Each translator circuit has internal zero and full scale calibration facilities. Each calibrator switch has a "normal" position which allows normal recording of data. When depressed the calibrator switch provides a signal to the individual translator circuit producing a zero or full scale signal to the recorders. The indicated output in meteorological units for each position of the calibrator is given below.

Parameter Zero Full Scale Type of Calibration Wind Speed 0 mph 100 mph Calibrated Voltage Wind Direction 0° 540° Calibrated Voltage Temperature

-20°F

+100°F Precision Resistance Dewpoint

-40°F

+100°F Precision Resistance Delta temp

-5°F

+5°F Calibrated Voltage Precipitation 0 in 1 in.

Calibrated Voltage 2.3.3.4 Data Recording Systems The primary data recording system used for the Susquehanna sites primary tower is a digital data acquisition system. The system is an integrated data conversion and recording station which scans up to 16 analog signal outputs, converts each 0 to 1 V DC input to a digital code which is stored and retrieved via modem interface.

The secondary recording system is the Control Room recorders.

It is estimated that approximately 10% of the data used at the Susquehanna site was obtained from strip chard records.

Spot checks were made to compare the strip chart and digital data. Although no formal records of these comparisons were prepared, it is estimated that the average differences between strip chart and digital data were as follows:

Temperature 1°F Wind Speed 1 mph Wind Direction 5 degrees Dewpoint 1°F

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-16 Temperature 0.5°F Precipitation

.05 inches All telemetry transmitters, translators, and the data logger are housed in a weatherproof cinderblock building. This building has thermostatically controlled heating and air conditioning.

2.3.3.5 Calibration and Maintenance of the System All calibration and maintenance is performed at least semi-annually in accordance with the frequencies and procedures prescribed in the manufacturer's operating and maintenance manual.

2.3.3.6 Data Analysis The analog recording system provides a back-up in case of digital system failure, so that a high data recovery rate can be maintained. Table 2.3-74 gives the recovery rates for each year.

An hourly average for each parameter is computed. Data validity, range of hourly averages, and the number of valid observations contributing to the averages are tabulated to assist in the determination of data reliability. Comparisons between the analog and digital data are performed when the review of the digital data reveals questionable or invalid data.

Temperature and dewpoint hourly averages are computed using the following scalar equation:

where:

ji j

n i

j B

r n

B

=

=1 1

j B

=

the average hourly value for the variable (in physical units) n

=

the total number of minute observations during the hour (normally 60), but if n is less than 15 for that hour, data are considered to be missing; Bji

=

the ith minute observation on the jth variable (millivolts);

r

=

the conversion factor to change the jth variable from millivolts into physical units.

After wind speed (WS) and wind direction (WD) are converted from millivolts they are related in the following manner:

If WS is invalid (999) then WD is marked invalid (999) and vice versa If WS > threshold (non-calm) and WD = 0 (implying calm) then WD is set to 360° (North)

If WS < threshold (calm) and WD > 0 (implying non-calm) then WD is set to 0° (calm)

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-17 Hourly averages are computed as scalars for wind speed. Wind direction averages are determined by vector analysis for all non-calm wind distribution of the lowest non-calm wind speed class by stability class.

If the associated average WS is less than.36 mps then average WD is set to 0° (calm) and average WS is set to 0 mps (calm).

NRC Regulatory Guide 1.23 (Ref. 2.3-22) suggests that data be averaged over a period of at least 15 minutes once each hour. Hours containing less than 15 minutes of valid data are invalidated.

The hourly averaged data are reviewed for validity, completeness, and reliability. Periods containing problems are then replaced by analog data.

Data analysis for diffusion characteristics for the site requires three basic atmospheric variables.

These three variables, together with the primary and secondary (back-up) measurements for each, are as follow:

Horizontal wind speed primary-10 m wind speed; secondary-60 m wind speed Horizontal wind direction primary-10 m wind direction; secondary-60 m wind direction Temperature difference (T) primary-delta T's from 10 m to 60 m; secondary-T from 10 m to 60 m If the 10 m wind speed is unavailable the 60 m wind speed is reduced to the equivalent 10 m value as follows:

H 10 V

=

V j

S j

10 where:

Hj

=

sensor height, meters V10

=

the equivalent 10 m wind speed Vj

=

the 60 m wind speed S

=

0.25 for Pasquill classes A, B, C, and D 0.50 for Pasquill classes E, F, and G The percentage of data recovery for the 10 m wind sensor indicates the extent of this substitution for the data period.

Temperature difference values are used to determine Pasquill stability classes. Atmospheric dispersion coefficients are assigned according to stability class and downwind travel distance.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-18 The hourly values of the meteorological parameters are then processed to obtain the following:

a.

joint frequency distributions of wind speed and stability for lower and upper levels (Tables 2.3-75 through 2.3-91)

b.

wind direction persistence summaries by stability class

c.

maximum, minimum and diurnal variation of temperature, and humidity

d.

annual average values of relative concentration with direction and distance

e.

frequency distribution of concentrations for the 0-2 hour, 0-8 hour, 8-24 hour, 1-4 day and 4-30 day time periods 2.3.4 SHORT-TERM (ACCIDENT) DIFFUSION ESTIMATES Atmospheric diffusion conditions (expressed as values of /Q) developed for use in evaluating accidents hypothesized in Chapter 15 are discussed in this section for various periods after an accident. This includes /Q estimates based on the methods described in Regulatory Guide 1.145. (Reference 2.3-34) All estimates use vertical temperature difference to determine stability classification. Tables 2.3-75 through 2.3-82 and 2.3-84 through 2.3-91 give the joint frequency distribution of temperature difference categories used to summarize 5 years of SSES data into Pasquill groups for use in computing y and z in the diffusion equations. Results are based on evaluation of a recent 5-year period of onsite meteorological data (1999-2003). A description of the site meteorological program is given in Section 2.3.3.

Methods used to estimate diffusion conditions for evaluating short-term accident releases are discussed in Section 2.3.4.1, and methods for assessing the consequences of longer term accident releases (up to 30 days) are discussed in Section 2.3.4.2.

2.3.4.1 Short-Term (0-2 hours) Releases The methodology for determining the atmospheric dispersion that exists for short-term releases involves direction-dependent and direction-independent calculations as described in Regulatory Guide 1.145. Both methods include the effects of plume meander as discussed below.

2.3.4.1.1 Direction-Independent Calculations The direction-independent approach involves computing /Q values for each hour of the period of SSES records used and then counting all of the hours that had /Q values equal to or greater than a selected value regardless of direction. The number of hours so obtained was then divided by the number of hours in the total period of record to obtain the probability that the selected /Q value would be equaled or exceeded. The resulting probabilities are independent of wind direction. A plot of cumulative centerline /Q values as a function of probability of occurrence was constructed using the SSES hourly data for all 5 years combined as shown in Figure 2.3-6. Equations 2.3-4, 2.3-5 and 2.3-6 in Section 2.3.4.4 were used to compute values of /Q. The distance to the site boundary (exclusion area boundary referred to as the EAB )

was assumed to be a circle with a radius of 0.34 miles (549 meters).

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-19 2.3.4.1.2 Direction-Dependent Calculations The direction-dependent calculations outlined in Regulatory Guide 1.145 require the /Q values to be calculated using the equations given in Section 2.3.4.4; however, the results are treated separately for each direction. A 5-year composite direction-dependent probability distribution was plotted by combining the frequency of occurrence of selected /Q values for each direction at the EAB as shown in Figure 2.3-7.

2.3.4.1.3 Determining Appropriate Short-Term Dispersion In accordance with Regulatory Guide 1.145, the two cumulative probability distributions shown in Figures 2.3-6 and 2.3-7 are used to determine the appropriate /Q value at the EAB distance.

The peak 5% value read from Figure 2.3-6 is 6.5E-4 s/m3. For the direction-dependent case, the 0.5% /Q is determined from Figure 2.3-7 to be 8.3e-4 s/m3. The highest of the two (/Q =

8.3E-4 s/m3) is to be used in accident dose calculations and is shown in Table 2.3-92 for the 1-hour case at the EAB. Tables 2.3-93 through 2.3-98 show the direction dependent results for each of the separate years plus the total for all five years at the EAB. For realistic dose calculations the 50% direction independent value is also shown in Table 2.3-92.

Similar calculations for short-term dispersion were made at the LPZ distance of 3 miles (4827 meters). Tables 2.3-99 through 2.3-104 give the direction-dependent /Q probability distributions for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> for each of the 5 years and the weighted 5 year average at the LPZ.

2.3.4.2 Long-Term Releases For releases that occur over a longer period, it is appropriate to incorporate wind direction changes in the model used to estimate concentration at any given point. Using the same 5-year period of data from SSES, the probability that any particular average diffusion condition (or poorer one) would exist during a selected interval of time (greater than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />) was determined.

The procedure for determining longer term-/Q values is also taken from Regulatory Guide 1.145. The calculation is made using the 5-year data set. The highest 0.5% direction-dependent short-term (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />) /Q value was used because it is greater than the 5% direction-independent at the LPZ. These /Q values are plotted on Figures 2.3-8 and 2.3-9 as a function of averaging time. Only the 1-hour values are used in the Reg. Guide 1.145 interpolation method. The long-term 0.5% /Q values for defined averaging times are determined by a log-log interpolation between the maximum direction dependent annual average and the maximum 0.5% direction dependent 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> value used at the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> averaging time. The long term 50%

values are determined by interpolating (log-log) between the 50% direction independent 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> value at the 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> averaging time and the direction independent annual average (see Figure 2.3-10). The interpolated values are summarized in Table 2.3-105. For the 50%

probable case the direction independent values were used because they are higher than the direction dependent values.

2.3.4.3 Analytical Methods for Dispersion Computations During neutral (D) or stable (E, F, or G) atmospheric stability conditions when the wind speed at the 10 meter level is less than 6 meters per second, horizontal plume meander is taken into

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-20 account. /Q values are determined through selective use of the following set of equations for ground level relative concentrations at the plume centerline:

(

)2

/

A U

1 Q

/

z y

10

+

=

2.3-4

(

)

z y

10 3 U

1 Q

/

=

2.3-5 z

y 10 U

1 Q

/

=

2.3-6 Where

/Q is relative concentration, in sec/m3 is 3.14159 10 U

is wind speed at 10 meters above plant grade, in m/sec y

is lateral plume spread, in m, a function of atmospheric stability and distance z

is vertical plume spread, in m, a function of atmospheric stability and distance y

is lateral spread with meander and building wake effects, in m, a function of atmospheric stability, wind speed U10 and distance [for distances of 800 meters or less, y = My, where M is a function of the atmospheric stability and wind speed; for distances greater than 800 meters, y = (M - 1) y800m + y].

A is the smallest vertical-plane cross-sectional area of the reactor building in m2.

/Q values are calculated using Equations 2.3-4, 2.3-5 and 2.3-6. The values from Equations 2.3-4 and 2.3-5 are compared and the higher values selected. This value is compared with the value from Equations 2.3-6 and the lower value of these two is selected as the appropriate /Q value.

The /Q value used in accident consequence analysis is selected from the maximum sector /Q values which is exceeded 0.5% of the time.

2.3.5 LONG-TERM (ROUTINE) DIFFUSION ESTIMATES The long-term diffusion characteristics for the Susquehanna SSES were estimated in accordance with the criteria set forth in NRC Regulatory Guide 1.111 (1977). The analysis was performed using the onsite meteorological data recorded at the primary tower for January 1999 through December 2003 and for data recorded at the primary tower for January 2017 through December 2021.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-21 2.3.5.1 Atmospheric Diffusion Models 2.3.5.1.1 Straight Line Airflow Model A ground level release model based on meteorological data and plant parameters was used to calculate the annual average atmospheric relative concentration (/Q) values. Depletion factors are computed directly from depletion curves as the relative deposition rates. For long-term, ground level relative concentrations, the plume is assumed to diffuse evenly over a 22.5-degree sector.

The hourly relative concentration values are calculated in the sector defined by the wind direction using the following equation:

x u

2.032

/Q z

=

(5)

Where

/Q

=

ground level relative concentration (sec/m3) z

=

vertical standard deviation of the plume (m) u

=

average wind speed (m/sec) x

=

distance from the source (m)

However, with consideration of the turbulent wake effect, Equation 5 is revised as follows:

/

cV

2.032

/Q 2

2 z +

=

ux

(6)

Where c

=

building shape factor V

=

vertical height of the highest adjacent building The wake factor (cV2/) is limited, close to the source, to a factor of 2z2.

If

V c

3 2

2 z

z

+

, the equation is x

u

3 2.032

/Q z

=

(7)

(i.e., /Q is calculated to be the larger of Equations 6 and 7). The total relative concentration at each sector and distance is then divided by the total number of hours in the database.

_t

=------1

_f t

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-22 2.3.5.1.2 Terrain/Recirculation Correction Factors The straight-line trajectory, Gaussian diffusion model assumes that a constant mean wind transports and diffuses plume effluents in the direction of airflow at the release point within the entire region of interest. In other words, the wind speed and atmospheric stability at the release point are assumed to determine the atmospheric dispersion characteristics in the direction of the mean wind at all distances. In areas of more complex terrain recirculation of the plume over longer time periods may occur. To account for this effect the results of a comparison of the PAM (Puff Advection Model) with the straight line model was made from which adjustment factors for the site region were determined. These correction factors were applied to the results of the straight line model by multiplying the /Q values by the correction factors found in Table 2.3-106.

2.3.5.1.3 Deposition and Depleted X/Qs As radioactive effluent in a plume travels downwind, it is subject to several removal mechanisms, including radioactive decay, dry deposition, and wet deposition (during precipitation). Corrections for radioactive decay of 2.26 days for undepleted /Q and 8 days of depleted /Q are shown in the dispersion estimates reported in this subsection.

Dry deposition, which results in depletion of halogen and particulate isotopes from the plume, is calculated using Figures 2 through 5 in Regulatory Guide 1.111. Depletion factors in these curves are a function of release height and distance. All releases at the SSES are at ground level. Therefore, elevated curves were not used. Each /Q is multiplied by the depletion correction factor to estimate the depleted /Q value.

To determine relative deposition rate as a function of distance and stability, the curves given in Regulatory Guide 1.111 are used in a computerized table look-up routine. Values from the curves are divided by the sector cross-width (arc) at the point of calculation to give units m-2.

2.3.5.1.4 Results of Long-Term Diffusion Estimates Long-term diffusion estimates are provided for two on-site meteorological data recording times:

(1) data recorded at the primary tower for January 1999 through December 2003, and (2) data recorded at the primary tower for January 2017 through December 2021.

Long Term Diffusion Estimates: Meteorological Data January 1999 - December 2003 Tables 2.3-107 through 2.3-118 present the annual and five year average /Q, decayed and depleted

/Q and deposition values at the site boundary and exclusion area boundary for each of the 16 cardinal directions. Tables 2.3-119 through 2.3-136 show similar information for the nearest residence, vegetable garden, meat and dairy animal location and selected special receptor locations around the plant. Tables 2.3-137 through 2.3-140 present the five year average /Q, decayed and depleted /Q and deposition values for the sixteen directions out to a distance of 80.5 kilometers (50 miles) from the plant.

Long Term Diffusion Estimates: Meteorological Data January 2017 - December 2021 As a result of changes to the site boundary, the location of residences within the site boundary and the addition of receiver locations outside the site boundary requiring dose evaluations, long term diffusion estimates are evaluated for meteorological data recorded January 2017 through

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-23 December 2021. These diffusion estimates are based on the 2021 Land Use Census.

Table 2.3-141 presents the annual average relative concentration and deposition estimates at the site boundary. Table 2.3-142 presents atmospheric dispersion estimates at selected locations. Tables 2.3-143 through 2.3-146 present the five year average /Q, decayed and depleted /Q, and deposition values at the nearest residence, vegetable garden, meat, and dairy animal locations.

2.

3.6 REFERENCES

2.3-1 Critchfield, Howard J., General Climatoloy, England Cliffs, New Jersey: Prentice Hall Inc., (1966) p.446.

2.3-2 U.S. Department of Commerce, Tropical Cyclones of the North Atlantic Ocean, Technical Report 55, (1965).

2.3-3 U.S. Department of Commerce, Local Climatological Data; Annual Summary with Comparative Data; Wilkes-Barre/Scranton Airport, Avoca, Pennsylvania (1993).

2.3-3a National Oceanic and Atmospheric Administration, Cooperative Institute for Research in Environmental Sciences, Climate Diagnostic Center, World Wide Web Internet Site, United States Climate Page, Monthly Values for 1961-1996, URL address http://www.cdc.noaa.gov.

2.3-4 U.S. Department of Commerce, Monthly and Annual Wind Distribution of Pasquill Stability Classes (7) Star Program, Wilkes-Barre Scranton, Pennsylvania Period 1/71-12/75. Environmental Data Service, National Climatic Center: Asheville, N.C.

(May, 1976).

2.3-5 Fujita, T.T. Characterization of Hurricanes and Tornadoes by Area and Intensity SMRP No. 92 (1971).

2.3-5a Knight, Paul, Pennsylvania State Climatologist, World Wide Web internet Site, State Data Miscellaneous Information Page, Tornado Data. URL address http://www.ems.psu.edu/PA-Climatologist.

2.3-6 Uman, M., Understanding Lightning; Carnegie, Pennsylvania: Beek Technical Publications, (1971).

2.3-7 Pautz, M.E. Severe Local Storm Occurrences, 1955-1967.

2.3-8 Thom, C.S., New Distributions of Extreme Winds in the United States, Journal of Structural Division Proceedings of the American Society of Civil Engineers, (July 1968) pp. 787-1801.

2.3-9 American National Standards Institute, Inc., Building Code Requirements for Minimum Design Loads In Buildings and Other Structures, A581-1972, (1972).

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-24 2.3-10 Tattelman, Paul and Gringorten, Irving I., Estimated Glaze Ice and Wind Loads at the Earth's Surface for the Contiguous United States. Air Force Cambridge Research Laboratories, Bedford, Mass., (1973).

2.3-11 U.S. Dept of Commerce, Local Climatological Data; Monthly summaries; Avoca, Pennsylvania, Wilkes-Barre Scranton Airport, (1973-1976).

2.3-12 Ohman, Howard L., Viletto, John, Jr., Ackerson, Kenneth T., and Miller, Le Forrest, Potential Sand and Dust Source Area, Report ETL-SR-771-1, (August, 1972).

2.3-13 Holzworth, G., "Mixing Heights, Wind Speeds and Potential for Urban Air Pollution Throughout the Contiguous United States," Preliminary Document, Environmental Protection Agency, (1971).

2.3-13a U.S. Naval Observatory, Astronomical Applications Department, World Wide Web Internet Site, DATA SERVICES, COMPLETE SUN AND MOON DATA FOR ONE DAY, URL address http://aa.usno.navy.mil/AA.

2.3-14 U.S. Dept. of Commerce, Seasonal Variation of the Probable Maximum Precipitation East of the 105th Meridian for Areas from 10 to 1000 Square Miles and Duration of 6, 12, 24, and 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />. U.S. Dept. of Army Corps of Engineers; Hydrometeorological Report No. 33. Wash., D.C.(April, 1956).

2.3-15 Dunlap, D.V., Probabilities of Extreme Snowfalls and Snow Depths; Bulletin 821; New Jersey Agricultural Experiment Station; Rutgers University, New Brunswick, New Jersey (1970).

2.3-16 U.S. Nuclear Regulatory Commission Regulatory Guide 1.76. Design Basis Tornado for Nuclear Power Plants. Directorate of Regulatory Standards (April, 1974).

2.3-17 Thom, H.C.S., "Tornado Probabilities," Monthly Weather Review, (October-December, 1963) pp.730-736.

2.3-18 Howe, G.M., "Tornado Path Sizes," Journal of Applied Meteorology, (3) pp.343-347, (April, 1974).

2.3-19 Dames & Moore, Tornado Evaluation for the Susquehanna Steam Electric Station, (1974).

2.3-20 Hershfield, David M., Technical Paper #40, Rainfall Frequency Atlas of the United States for Duration from 30 minutes to 24 Hours and Return Periods From 1 to 100 Years; U.S. Department of Commerce, Washington, D.C., (1974).

2.3-21 Riedel, John T., Personal communication NOAA Office of Hydrology about soon to be released revision of Hydromet. Report #33 (February, 1977).

2.3-22

-U.S. Nuclear Regulatory Commission, Second Proposed Revision 1 to Regulatory Guide 1.23, Meteorological Measurement Program for Nuclear Power Plants, April 1986.

SSES-FSAR Text Rev. 62 FSAR Rev. 71 2.3-25 2.3-22a Atomic Energy Commission, Safety Guide 23 (Regulatory Guide 1.23 Rev. 0),

Onsite Meteorological Programs. Office of Standards Development, February 1972.

2.3-23 Not Used.

2.3-24 Not Used.

2.3-25 Not Used.

2.3-26 U.S. Nuclear Regulatory Commission, Regulatory Guide 1.111. Methods for estimating atmospheric transport and dispersion of gaseous effluents in routine release from light-water-cooled reactors. Office of Standards Development, (July, 1977).

2.3-27 Not Used.

2.3-28 Not Used.

2.3-29 Not Used.

2.3-30 Not Used.

2.3-31 Not Used.

2.3-32 Not Used.

2.3-33 Doty, Stephen R, Wallace, Brian L., Holzworth, George C. A Climatological Analysis of Pasquill Stability Categories Based On "Star" Summaries National Climatic Center (April, 1976), p.51.

2.3-34 U. S. Nuclear Regulatory Commission, Regulatory Guide 1.145. Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants, Reissued February, 1983.

SSES - FSAR TABLE 2. 3-1 HURRICANES WITHIN 75 AND 150 NAUTICAL MILES OF THE SUSQUEHANNA SITE PERIOD OF RECORD 1871 to 1969 TRACJ<S TRACKS TOTAL WITHIN WITHIN NORTH 75 NM*

150 NM*

ATLANTIC STORMS TIME PERIOD Prior to 8

18 1900 After 1900 0

2 1871 TO 1969 8

20 489 Occurrence by Month June 0

1 July 0

0 August 2

3 September 4

10 October 2

6 Totals 8

20

  • NM represents nautical miles.

Rev. 48, 12/94

January February March April May June July August September October November December SSES -

FSAR TABLE 2.3-2 THUNDERSTORM DAYS FOR AVOCA, PENNSYLVANIA WILKES-BARRE SCRANTON AIRPORT PERIOD OF RECORD 1956 TO 1974 VALUES ARE EXPRESSED IN DAYS (Ref. 2,3-3)

MONTH THUNDERSTORM DAYS (to the nearest whole day) 1 2

4 6

8 5

3 1

Annual Average 30

  • Less than one-half Rev. 48, 12/94

SSES -

FSAR TABLE 2.3-3 TOTAL NUMBER OF DAYS IN 5 YEARS MIXING HEIGHTS< 1500m WIND SPEEDS < 4. 0 sec*1 and NO SIGNIFICANT PRECIPITATION FOR EPISODES LASTING AT LEAST 2 DAYS Season of Greatest# of station Episodes Episode-days Episode Days Pittsburgh, PA 16 39 Autumn New York, N.Y.

4 9

Autumn Albany, N.Y.

7 23 Autumn Rev. 48, 12/94

SSES -

FSAR TABLE 2.3-5 MEAN MONTHLY VALUES:

SUSQUEHANNA SITE (1973-1976)

Wind Speed Dry Bulb Wet Bulb Month (m/sec)

(C)

(C)

January 2.3

-2.1

-3.6 February 2.0

-1.4

-3.4 March 2.7 3.6 1.1 April 2.8 8.8 5.2 May 2.0 13.8 10.6 June 1.7 18.8 16.1 July 1.5 20.3 17.7 August 1.4 20.0 17.7 September 1.6 15.0 12.9 October 1.9 9.9 7.6 Novetnber 2.1 4.9 2.6 December 2.1

-0.9

-2.6 Annual 2.0 9.3 6.9 Rev. 48, 12/94

SSES - FSAR TABLE 2.3-6 LONG-TERM AVERAGE WIND SPEED AND PREVAILING DIRECTION AT WILKES-BARRE SCRANTON AIRPORT Period of Record:

1956-1974 Average Prevailing Month Speed (mph)

Direction January 8.9 SW February 9.3 SW March 9.3 NW April 9.6 SW May 8.8 WSW June 7.9 SW July 7.4 WSW August 7.2 SW Septelllber 7.4 SW October 7.9 WSW November 8.7 WSW December 8.9 SW Annual 8.4 SW Rev. 48, 12/94

Month January February March April May June July August September October November December Annual Rev. 48, 12/94 TABLE 2. 3-7 AVERAGE WIND SPEED AND PREVAILING DIRECTION AT THE SUSQUEHANNA SITE Period of Record (1973-1976)

Average Speed (mph) 5.1 4.5 6.0 6.3 4.5 3.8 3.4 3.1 3.6 4.3 4.7 4.7 4.5 Prevailing Direction WSW SSW w

w w and E WSW WSW ENE ENE E

w w

WSW

TABLE 2.3-8 WIND DIRECTION PERSISTENCE -

PASQUILL A (1973 -

1976) 1CONSECUTlvE HOU~S SECTOR 2

J 4

t, 1

8 CJ 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

>24 NNE

~l

'j 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 NE 12 5

J (i

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 ENE.

17 4

3 0

0 0

0 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

E 19 2

1 0

0 l

V 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ESE 10 3

0 0

u 0

0 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

s~~

11 s

0 1

l 0

u 0

I) 0 0

0 0

0 0

0 0

0 0

0 0

0 0

8 12 t,

2 1

0 u

0 u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

s 4t, le 8

2 0

0 0

u u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

SSW 49 l ':>

ll J

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SW 80 2b 10 9

1 l

1 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

WSW 123 5'>

20 13 l

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 102 I>~

29 17 10 3

3 l

l u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

WNW N

lb 8

)

()

0 1

0 u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

NW b

l 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

NNw l t, 2

3 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 N

16 s

7 1

c 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 AVENAGt WINU S~EE.O

(~/Sl:.Cl CONSECUTlVE HOV~S SECTOR z

4 5

6 7

8 9

lU 11 12 13 lit 15 lb 17 18 19 20 21 22 23 24

>Zit NNE

~.64 3.15 2.56 o.

o.
o.

8:

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NE

.38 2-'.:>8 2.87 J.09 o.

o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

V>

ENE 2.41 2odb 2.8b O.

o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

I E

2.s1 1.1,5 J,t,2 o.

o.

J.44 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

ESE.

2,29 2ob'.:>

O

o.
o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

E SE l.b~ z.2~ g*

f-0~ ~-~So.

o.
o.
v.
o.
o.

8:

o.
o.
o.
o.
o.

8:

o.
o.
o.
o.
o.
o.

SSE 2.Z 2.02

.2tl

.1:1c,

.ZJ o.

ll *

o.

I).

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

s z.13 2.~'+ 3.44 '+.d~ J.1s o.

o.
o.
v.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.

SSW 2.&6 2o1l J,b4 4.02 ~.Ol O.

6.7t, O.

v.

Oe

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SW 2.37 2.6~ Z.'.:>8 2.d4 j.29 l.OO J.b4 0,

v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

WSW

~.~4 2aY7 J.20 J.l~ J.Y4 4o2£ 2.Jl o.

c.4~ O.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

. s1 J.61 J.b7 4.J4 J.b3 ~-~u J.b~ 6,33 J.04 o.

o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.

8:

o.

WNW 4.JJ 4ol:IJ 4.150 5.4J ~.~l Oo

\lo 4a4Y Oo Oo

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N'°"

J.23 4.54 4.3~ s.~~ o.

o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NNW 3.59 4.37 ~.53 4.bti 6.45 O.

u.

O.

~.

Oo

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N 3.2~ 3ab4 3o2b 3.1~ 3,66 Vo

o.
o.
v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

TOTAL NO. OF 08St~VATIO~S = 35064 Rev. 35, 07/84

c,,

I l"I N

IO

°'

ri

> u

~

Ill z 0 u 0000000000000000 N

A 4

0000000000000000

~ 0000000000000000 1\1 0000000000000000

.,. 0000000000000000 N

0 0000000000000000 1\,1

~ 0000000000000000 m 0000000000000000

,._ 0000000000000000

~ 0000000000000000

~ 0000000000000000 0000000000000000 M 0000000000000000 N 0000000000000000 0

0000000000000000

~ 0000000000000000

~ 0000000000000000 Ir 0

l&Jl&Jl&J'.,JIIJW,.;1/lJtJt:SJIJtJtJt Z 1-z~z 111111vi v,v,111 zzz U

Z W

W Ill Ill > > Z w

Ill u...,

Ill I

SS!S - PSAA 1\,1 0000000000000000 1\1 0000000000000000 0

IV 0000000000000000 0,..

.,. 0000000000000000 G)

.,. 0000000000000000 0000000000000000

-0

.,. 0000000000000000

.,. 0000000000000000

.,. 0000000000000000

>000000000000000 N

0000000000000000

.,. 0000000000000000 ooooooo.;100000000 (1-J)

"'l 0000000000000000 0000000000000000

0 0

~

NJ'I

.fJ 00~.fJ~OOOOOOO~OO~

OC"OOO=> *:>-:J:>O.::>':>:>::>OO MMO~oo-M.fJ,C~N~-oN

~~nooe--~~-n~~~~

~;~~~;gj$~~~!~

N'\/'\l-NN.-.'\/,.._,-,,..,,J\,tNMN

-Nll'i,-~,:o,C,,_l\i,.._,-. MOO"'lC7'

~,-.,e,eo~o,t~~,t~i,-,-.N~

NN-NN.-.NNNMM,tMMMN Ill z

C >

.l'...,

VI

.J) 0 0 z

.J C

l-o Q) 0 If)

M

TABLE 2.3-10 WIND OIRECTION PI:PSISTENCE -

PASOUILL C (1973 -

1976)

CONSlCUTivE HOU~S SECTOR 2

3 4

~

t, 7

8 9

10 11 12 l.J 14 lS 16 17 18 19 20 Zl 22 23 24

>24 NNE 6

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

C, NE 7

0 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8 0

0 8 8 0

0 ENE 4

l 0

0 0

0 0

0 0

\)

0 0

0 0

0 0

0 0

0 0

(,

ES~

l 0

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 8

0 0

8 0

ti l

0 0

0 0

0 (J

0 0

0 0

0 0

0 I) 0 0

0 0

8 0

C, SE.

l l

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

(;

SSE 3

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

(,

s 14 1

0 0

1 0

0 0

0 I) 0 0

0 0

0 0

0 0

0 0

0 0

0

{,

SSW 10 0

l y

0 0

0 1

0 0

0 0

0 0

0 0

0 0

8 0

0 0

0 C,

s*

l3 s

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8 0

8 0

0

(/

WSW 15 J

l 0

0 0

0 0

0

\)

0 0

0 0

0 0

0 0

0 0

0

(,

w 11 J

1 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 C,

lfNW 3

2 0

0 0

0

\)

0 u

\)

0 0

0 0

8 0

0 0

0 0

0 0

0

(,

NW 5

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8 0

8 0

0 NNW 7

1 l

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

(,

Ill 10 2

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

(,

AVENAtil WINO S~EEO CONSlCVllyE "OURS (M/St::CI SECTOR 2

J 4

5 t,

7

~

9 lo 11 12 13 14 15 16 17 18 19 20 21 22 ZJ 24

>Z*..

8:

NNE 2.os 2.49 o.

o.
o.
u.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NE

~=~~ o.

J.tH o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

Q.

I ENf.

2.44 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
f.

3.05 1.Jo o.

o.

4.93 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

8:

o.
o.
o.
o.

e,.

ESE f:~J o.

o.
o.
o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.

8:

8:

o.

8:

o.
o.
o.
o.

t s§~

l

  • OJ o.
o.
o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

Q.

  • 39 l o4t\ o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

o *

o.

s 3.75 J.8J o.

o.

~.~S u.

o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

e,.

SSW 3.e,3 o.

2.15 o.

o.
o.
o.

4o63 u.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SW

~.JS S.1 7 o.

.).67 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

8:

o.
o.

WSW

  • 75... os... 02 o.
o.
o.
u.
o.

o.

o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

(I.

w

... 09 4.l:19 l. 60 S.S9 o.

o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.

8:

o.
o.
o.

WNW j.n S.45 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NW'

... 6 o.

o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N1,jW

).45 l.tis 4.t,9 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N 3.14..

  • t6 3.11 o.
o.
o.
o.
o.
u.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

c,.

TOUL NO. OF' OBStWVATIONS = JSOt.4 Rev. 35, 07/84

TABLE 2. 3-11 WINO DIRECTION PERSISTENCE -

PASOUILL D (1973 -

1976)

CONSt.CUTlvE. HOURS SECTOR

  • 2 J

4 s

0 7

ti 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

>24 NNE 79 2':>

4 3

l 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Nl 90 2l 17 t!.

2 0

1 c'

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 ENE.

60 17 5

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

t:

53 10 b

J 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 ESE 33 l iJ 6

(J j

0 0

0 (J

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SE 24 (I

2 t!.

(I 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SSE 33 16 4

1 2

0 0

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 s

62 t!.4 7

7 4

4 2

0 1

V 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SSW 74 JO 4

2 0

j 0

1 0

V 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SW 101 Jt!.

I<

J 0

2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 WSW 134 f:>0 23 9

7 2

J l

V 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

w 102

<+ l 2t>

21 lJ t!.

l l

t!.

u 0

l 0

l 0

0 0

0 0

0 0

0 0

0 WNw 68 2b l ':>

t!

.J 4

2 0

t!.

0 0

0 0

0 0

0 0

0 8

0 0

0 0

0 NW 63 2'1 7

3 0

0 0

0 0

V 0

0 0

0 0

0 0

0 0

0 0

0 0

NN'W 45 21 5

3 l

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 N

47 u

b 1

2 0

0 l

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

AVERAC,t Ill I NI) SPEt.O

("'/St.Cl COIIISlCUllvt P,,Uu~S

'SECTOR 2

J b

7 t!

~

lo 11 12 13 14 15 16 17 18 19 20 21 22 23 24

>24 I"'

NN£.

1.98 2.11 2.37 3. IS 4.38 o.

2. ti l o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

Mc 1.9a t!.-32 ;>

  • l J 2.bS 2o6b J.4'!:I o.

2.7J.:::

  • Jc o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

I ENE 2.1 O c'.J) l.be 2.00 o.

4.00 o.

o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

£ 1

  • 79 1.t12 2.21:l 2.52 o.
o.
o.
o.

tJ.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

ESE 1.55 c:'.Ju l.tll o.

,!_.i,9 o.

o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

t s~~

1.t11 l.4tl I)*

3.7S t!..,::7 o.

o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

1.48 l.9i, 2.62 l * 'lh 1.es u.

o.

2.67 "*

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

s

2. l 0 c'.40 2.':>7 l od'il i:.'.oOd t.J'I J.03 o.

.J. 79 o.

o.
o.

IJ.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSW 2.05 l. 7':> I.2i:.'. s.c1 IJ

  • c'.4.J u.

4oS4 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SW

l. N 2 *. H 1.77 l. 1 S o.

c:' *..,~ o.

o.
v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

WSW 2.49 c.73 3.03 2.~2 2.~2 t.l/... oA J.7~ v.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

w J.19 3.':>b 3.'lt> 4.20 3.11 4

  • 5d s.s~ 5.50 ". 71 o.
o.

4.25 o.

J.29 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.

WNW

3. 71 J.t>O 4.01 ) * "7 ':,.J',I ~.41 4.t>.. o.

~.to o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N"'

3.06 3.0':, 3.1:lJ 3.M:, o.

o.
o.
o.

ll.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

Nfl/W 2.77 2.*n 3.93 3.40 c,.47 v.

o.
o.
u.
o.
o.
o.
o.

o..

4.7) o.

o.
o.
o.
o.
o.
o.
o.
o.

N 2.33 J.a 2-~7 l *"".J.b4 o.

C,.

t>. i,13 v.

o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

TOTAL NO. OF' O~Sl~VATIOl'wS = 3'.,064 Rev.

3 5, 0 7 / 8 4

TABLE 2.3-12 WINO DIRECTION PERSl~T!':NCT. -

PASQUILL E (1973 - 1976)

CO~SECVllyE HOUPS SECTOR:

2 3

4 s

b 7

8 y

10 11 12 13 14 15 16 17 18 19 20 21 Z2 ZJ 24

>Z,.

NNE 47 20 4

2 l

l 0

l 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 E~f 98

£1 4

4 J

0 0

0 0

0 0

0 l

~

0 0

0 0

0 0

0 0

0 0

103 31 21 1

u 0

2 0

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 E

89 33 8

11 l

0 l

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ESE 38 s

5 2

0 u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

SE 23 3

l 0

t 0

0 0

I) u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SSE 19 y

1 l

0 0

0 (I

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 s

34 lJ 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ss..

44 6

6 3

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

SW bl 2ti 10 4

0 1

0 0

u 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

ws""'

b4 33 12 10 3

3 3

0 u

I) 0 0

0 0

0 0

0 0

0 0

0 0

0 0

w 61 22 11 2

l i!

0 1

I) 0 0

0 0

l 0

0 0

0 0

0 0

0 0

0 WNW 32 10 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 NW

~~

4 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 NNW z

3 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Ill 37 lY 4

0 0

0 0

0 u

0 (I

0 0

0 0

0 0

0 0

0 0

0 0

0 AVERAbl WINO snEO CM/SlCl CONSECuTlvE hOUPS

, SECTOR c

)

4

~

b 7

9 lu 11 12 13 14 15 16 17 18 19 20 Zl 22 Z3 2ft

>24-f/1 NNE 1.55 l.~6 2.39 1.59 loll l.Y~ o.

1.10 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NE 1.47 l.J.,. l.62 2.26 l.':>7 o.

o.
o.
o.
o.
o.
o.

1.89 o.

o.
o.
o.
o.
o.

8:

o.
o.
o.
o.

I ENE 1.34 1.03 1.46 1.12 o.

o.

.Hl o.

1.02 o.

o.
o.
o.
  • 98 o.

o.

o.
o.
o.
o.

o.-

o.
o.

E l.ll 1.12 1.30 1.00 l. l 2 J.47 o.

l. 04 o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

ESE l.l)

  • 113 l.!:12 1.45 o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

t s~f 1.11

  • 'H
  • BY o.
11.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

1.12 2.us 2 'H 1.~t,.i'..38 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

s 1.sa 1*63 2.37 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSW 1.2a 1... u 1.52 1.ll 2.21 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SW 1.47 1.35 1.10 1,3} o.

£,0',I o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

ltS'-

l,Yl lo29 2.4 7 2.3 t.71 2.6'-J J.t,5 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

w 2.':>9 2.':>7 J.':,',I 3.5~ J... o 2.su o.

s.e.2 o.

o.
o.
o.
o.

5.11 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.

WNW 2.32 i.ot. c.7b o.

o.
o.
u.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

Nli

2. 7 l.i,o 2.74 g:oJ o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

(j.

NNW l:1~ t.66 2.3..

o.
o.

(I.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N 1 049 1.6,! o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

TOTAL NO. OF OBStWVA TIONS :: 3506'-

Rev. 3 5, 0 7 / 8 4

TABLE 2.3-13 WIND DIRECTION ~?.RSISTENCE -

PASQUILL F (1'73 -

1976)

CONS~CUTIVE HOU~S SECTOR 2

3 5

t, 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

>24 NNE lit t,

2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

NE 36 l

l 0

i) 0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ENE 89 z~

13 11 7

l l

0 (J

0 0

1 0

0 0

0 0

0 0

0 0

0 0

0 E

85 Jl 14 t,

3 1

l v

0 0

0 0

0 0

0 0

0 0

0 0

0 0

ESE.

20 l

l 0

0 0

0

\)

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SE 0

0 0

0 0

0 0

u u

0 0

0 0

0 0

0 8

0 0

0 0

8 0

0 ss§ 2

0 u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 u

0 0

0 0

0 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

SSW 2

0 0

0 0

0 0

0 u

0 0

0 0

0 0

0 0

0 o

  • 0 0

0 0

SW t,

c 0

0 0

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8

-,sw 5

l 0

0 0

0 0

0 I) 0 0

0 0

0 0

0 0

0 0

0 0

0 w

~

l l

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

g 0

0 WNW 4

0 0

0 0

0 0

0 u

u 0

0 0

0 0

0 0

0 0

0 0

0 0

NW s

0 0

0 u

0 0

0 0

0 0

0 0

0 8

0 0

0 0

0 0

0 0

0 NNW 3

l 0

0 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

N 12 2

l l

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 AVE~AGt. WINO SPlll>

(""/SE.Cl

'\

CONSECUTIVE 1-1ov~s SECTOR 2

3 4

5 6

7 I!

9 l II 11 ll lJ 14 15 16 17 18 19 20 21 22 23 Zit

>2'-

a, NNE

.88...,, 1.01 o.

o.
o.
o.
o.
u.
o.
o.
o.
o.

o.

o.
o.
o.
o.

8:

o.
o.
o.
o.
o.

NE

  • 91

.12

  • '54
  • 91\ o.
o.
o.
o.

o *

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

o.

ENE

  • 97 1
  • 13 l.c!U }.40 l. OS 1.9/ 1.56 u.
o.
o.
o.

1.34 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

E.

l. 06 1-~s 1.ou lo24 l
  • l 7 I..::>
  • 1,(/

.9l. l*bc o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

ESE

.92 1.1e 1.13

  • '-J3 8:
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

8:

o.

8:

o.

SE

o.
o.
o.
o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSE.

  • 71 o.
o.
o.

v *

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

s

  • 86 o.
o.
o.
o.

1,1.

o.
o.
v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSW l.J8

.10 o.

o.
o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SW l,12

.':>3 0,

o.
o.

2.01 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

WSW l.98 ob'l

.93 o.

o.
u.

o.

o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

w

  • l:l,

.64

.76

  • &4 o.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

WNl,j

.79 o.

o.
o.
o.
o.

u *

o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NW

  • t1S o.
o.
o.
o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NNw

.9.-,..tl9 o.

o.
o.
o.
u.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

"I 1,14 1.':>3

.t19 l. l4 I* 36 o.

u.
o.
v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

TOTAL NO. or o~st.~VAT)O~S = 3':>064 Rev. 35, 07/84

TABLE 2. 3-14 WIND DIRECTION PERSISTENCE -

PASQUILL G (1973 -

1976)

CONSECUTIVE nouus SECTOR 2

3 s

6 7

t, 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

>24 NNE 5

l g

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 8

0 0

0 0

0 E~~

2~

'I l

0 0

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 so l !l 12 l

l

.)

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 E

36

21) 13 7

0 2

l 0

u 0

0 0

0 0

0 0

0 0

0 0

0 8

0 0

ESE 9

4 0

0 u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

8 0

SE l

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

SSE.

0 1

0 0

0 0

(/

0 0

0 0

0 0

0 0

0 0

o*

0 0

0 0

0 0

s 0

0 0

0 0

0 0

0 0

V 0

0 0

0 0

0 0

0 0

0 0

0 0

0 SSW 2

0 0

0 u

0 0

0 0

0 0

0 0

0

(/

0 0

0 0

0 0

0 0

0 Sll l

0 0

0 0

0

()

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 IIISW J

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 w

2 u

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

WNll 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 NW 0

0 0

0 0

0 0

0 0

0 0

0 0

8 0

0 0

8 8

0 0

0 0

0 NNW 0

0 0

u 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 N

6 3

0 l

2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

AVE.RAG~ WINO SPEED (M/S~CI CONSECUTIVE ~OURS

\ SECTOR 2

J

~

b 7

~

"I 10 11 12 13 14 15 16

!7 18 19 20 21 22 23 24

>24

.c NNE.
  • 98 1.01 o.
o.
o.
o.
o.
o.
o.
o.
u.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.

-.r.

NE.

I.04 1.os 1.1s

.73 o.

o.

1.01 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

ENE 1.03 l. 02 1.a 1.47 1. 33 I.6 7 1.~s 1.76 u.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

E 1.02 1.01 1.2<.' 1.l) o.

t.Sb l.,D o.

u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
.c ESt
  • 99

.111 o.

o.
o.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

~

SE

  • 69 o.
o.
o.
o.
o.
o.
o.
v.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSE

o.
  • 63 o.
o.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

s

o.
o.
o.
o.
o.

I).

o.
o.
v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSW

  • 69 o.
o.
o.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

Sw

  • 94 o.
o.
o.
11.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

WSW

  • 76 o.
v.
o.

I).

v.
o.
o.
v.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

w 1.08 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

IIINW

  • 8', o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

~"'

o.
o.
o.
o.
v.

ll.

o.
o.
v.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

8:

8:

o.
o.

NN\11

  • 92 o.
o.
o.
o.
v.
o.
o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N l *'- 7

.~5 o.

1.48 l... o u.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

TOTAL NO. OF' Ot,<;t."1\fA TIONS = 350!>..

Rev. 35, 07 /84

TABJ..E 2.3-15 WIND DIRECTION PERSISTENCE -

PASQUILL ALL (1973 -

1976)

CONSt.CUTIVE !-'OURS SECTOR '

2 3

s 6

7 1:1 9

10 ll 12 13 14 15 16 17 18 19 20 21 22 23 24

>24 NNE 21!

81 26 l';:,

4 J

3 2

0 u

0 l

0 0

0 0

8 Q

0 Q

0 0

0 0

NE Jl 107 bO

?2 11 7

1 3

0 l

0 1

0 0

0 0

0 0

0 0

0 0

ENt:

328 121:1 79

)4 l ':>

9

'I l

l 0

2 2

0 0

0 0

0 0

0 0

0 0

E 271

<;'I

6) 3':>

21 17 9

'I 4

l l

0 l

0 0

0 0

0 0

0 0

0 0

0 E~t 140 44 15 9

J 2

0 0

l 0

0 0

0 8

0 0

0 0

0 0

0 0

0 0

90 11 7

l 2

0 C,

1 I/

0 0

0 0

0 0

0 0

0 0

0 0

0 SSE

',IQ 3d 13 11 7

0 l

l l

l 0

0 1

0 0

0 0

0 0

0 0

0 0

0 s

lSS bo 29 14 l,.

0 J

s l

l 1

0 l

1 0

0 0

0 l

0 0

0 0

SSW 184 di 33 11

~

7 J

l J

z 0

0 l

0 0

0 0

0 0

0 0

0 0

Sit' JOS 114

'>4 20 1..

12 7

1

~

l 0

0 0

0 l

0 0

0 0

0 0

0 0

0 WSw 373 lbb

\IJ Sb 23 13 lb J

l 1

1 2

0 0

0 l

0 0

0 0

0 0

0 w

309 l 2'1 93 63

,!4 l'>

20 2

0 z

0 0

l 8

0 0

1 0

0 0

WNW lt>J O'.:>

ti 1..

ll 7

ts 2

J (I

0 u

0 l

1 0

0 0

0 D

0 0

0 NIii 121:1 5!,I ti 4

0 u

0 l

0 0

0 0

0 0

0 0

0 y

0 0

0 0

NNw 123 4t, 21 13 10 0

~

0 0

(J 0

0 0

0 0

0 l

l 0

0 0

0 0

N lSS t,t!

JO lo 1:1

~

1 l

u l

0 0

0 0

l 0

0 0

0 0

0 0

0 lV[HAC,t:.

1i111'jo S1-'HO lM/St:.CI CONSECUTIV( HUURS "SECTOR 2

J 4

t, 7

1:1 9

10 It 12 13 14 15 lb 17 18 19 20 Zl 22 23 24

>24 Ii'> "'

!'I NNI::

1.77 l.94 2.2'"1 2.31 3.79 J.O'.:> t.Ot, l.4S o.

o.
o.

...45 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

V, NE.

1.54 I.1:10 c'.Ul z.2'j 1. 99 2. J.. 1 *t,IJ 2.13.:..74 u.

... 11 o.

l.89 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

I (NE.

1.40 l

  • _,,. 1.5.. l.'+3 l. 18 :c.u 1.':>O l
  • Oo,....., 1.01 1.01 o.

t.<+4 1.08 o.

o.
o.
o.
o.
o.
o.
o.
o.
o...

E l.37 l.21 l.21::-

1.17 l.J2 1... '

l * '14 2.00 1.27 2.12 3.lS o.

1.49 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o. t ES£ l *" 3 l.St> 1.37 l
  • o, 7
.6 l o2b o.
o.

c'o'IO u.

o.
o.
o.
o.

8:

o.
o.
o.
o.
o.
o.
o.
o.
o.

SE.

1.03 l.':>~ 1.8b 3.20 l

  • t, l
  • t!':> \J.
o.

.:.t>7 \).

o.
o.
o.
o.
o.
o.
o.

8:

o.
o.
o.
o.
o.

SSE.

l.t,) l Od l ti'- 2.ou c' * (it, v.

i-4t> 2o67 c'obt! 3.-,,c, o.

o.

1.95 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.

s l

  • 71 2.13 2o64 2.l7 <:
  • 14 2.10 c. t> l 2.*-11 0oC4 J.3<! 4.6S 3.99 o.

S.26 4.06 8:

o.
o.
o.

4.89 o.

o.
o.
o.

SSW 1.*,IJ ~.11 2.51 2...., J.11:1 ~-u~ I * '11... s.. ~.16... o~ 4.09 o *

o.

4.94 o.

o.
o.
o.
o.
o.
o.
o.
o.

511' 1.~1 l.-,1',l l. ',llo 2.2b 2.<+~.J.2J 1

  • 7 7. 3... l t!.o2t! t!.'<~ 3:36 o.
o.
o.

5,.11 o.

o.
o.

o *

o.
o.
o.
o.
o.

WS'II 2.4J ;> *'- 7 2.77 2oiil" J. l..; Jdl J.t>i, J.7b.J.2~... vJ Z.3~ 2.dl o.

o.

o.

3.69 o.

o.
o.
o.
o.
o.
o.
2. 19 J.0t, 3.<+'> 3.6':i J. t:!4.3. ':,' J.78 '-*"' "*"".. s. u,... so 5.23 o.

...~o o.

o.

4.44 o.

o.

o.

51.58 o.

o.
  • o.

WNW 2.'IO.3 * '> l 3.t, 7 3.Y7 4.J.. C,.':>l... ';,',l '>*lo ~-20 o.

o.
o.
o.
s. 8 S.45 o.
o.
o.
o.
o.
o.
o.
o.
o.

Nii

2. 70 3.0t! 3 *'> l 4.U7 J.os I).
o.

(J.

J.,, o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NN'W 2 *" I J.01 J.U J... l 3.'J) o.

~-62 o.

u.
o.
o.
o.
o.
o.
o.
o.

1.86... 12 o.

  • z-o.

o.

o.
o.

Ill l * '17 2.zi, 2.,u 2.Jt! 2.1::,0 lo4t!. l

  • 7 3 I.2tt.... ~~ o.

...21 o.

o.
o.
o.

6.2lt o.

o.
o.
o.
o.
o.
o.
o.

TOTAL "40. OF" OSSH<VAT !Qt,jS = J':>064 Rev. 35, 07/84 7

TABLE 2. 3-16 WIND DIRECTION PERSISTENCE -

PASQUILL E, F, & G (1973 -

1976)

CONSECUTIVE MOUWS SECTOR 2

3 4

~

b 7

8 9

10 11 12 13 1-.

15 16 17 18 19 20 21 22 23 24

>24 NNE 77 29 7

4 0

2 0

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 NE 183

.. t, 17 7

4 l

2 0

0

\I 0

0 l

0 0

0 0

8 0

0 0

0 0

0

It.

235 9..

'::,4 21 lS t,

lo 2

b 0

l 0

2 2

0 0

0 0

0 0

0 0

0 ES~

1 77 7t, 46 30 l/

1..

1 6

l 0

0 l

0 0

0 0

0 0

0 0

0 0

0 74 16 5

l 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

SE 3'::,

l 0

IJ 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

SSE 26 1J 4

1 I

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 s

44 12 3

l 0

0 0

0 u

0 0

0 0

0 0

0 '

0 0

0 0

0 0

0 0

SSW 4/l lJ 9

3 I

0

(>

0 u

I) 0

' (l 0

0 0

0 0

0 0

0 0

0 0

0 Sw 60 31 I~

s 0

1 l

l V

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 WSW 61 3'-1 It>

3 4

j 0

u V

0

  • o 0

0 0

0 0

0 0

0 0

0 0

0 w

86 29 12 2

l 2

c 1

u 0

0 0

0 l

0 0

0 0

0 0

0 0

0 WNW

,.9 12

'j u

0 0

u 0

0 C,

0 0

0 0

0 0

0 0

0 0

0 0

0 0

NW 38 4

2 0

0 0

0 0

0 u

\J 0

0 0

0 0

0 0

0 u

0 0

0 0

NNW 41 t,

3 2

I) 0

()

0 C,

0 0

0 0

0 0

0 0

0 0

0 0

0 0

C, N

63 30 8

l 2

3 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 AVERAGt. WINO s.-Et.0 (M/St:Cl CONSt.CUT 1 V~ HUU~S

\

10 17 18 19 20 21 22 23 24 Cl>

SECTOR 2

J 4

5 0

7 9

11 12 13 14 15 16

>24

<n NNE 1.26 I o4S 2.oJ l.60 o.

2.0l o.

1.10 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

V, NE 1.26 1.17 l... tl 1. '>9 l,44 l. Ob

.'19 o.

o.
o.
o.
o.

l.89 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

I ENE 1.13 1

  • 04 1.21 1.10 l, 12 l. vt> ).43

,99 l... 0 o.

l. t> l o.

1.44 1.08 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.

t 1.05 1.06 1.03 }.Ob 1,21 l,JJ I,lb 1.07 l ov'-J loltl o.

o.

1.49 o.

o.
o.
o.
o.
o.
o.

8:

o.
o.
o.

Cl>

ESE.

1.06

,t19 1.s2 1

  • l 7

,'-12 u.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

t 5£ 1.57

  • ',IQ
  • tl',I o *
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

8:

8:

8:

o.
o.
o.

SSE 1.55 2.02 1.63 1.86 2.)8 o.

u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

s 1.39 l

  • 1 3 l.46 2.v,. o.
o.
o.
o.
11.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SSW 1.22 l,23 l.61 1

  • 11 2.21 o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

SIii 1.46 l. 35 l.63 l o'+b u.

2.0'1

.92 2.03 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

WSW 1.93 2.10 2.21 2.JJ 2.11 J.,!(J J.65 o.

u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

w 2.22 2.Jtl 3.'::,J 3.S~ 3.40 2.50

  • 17 S.62 u.
o.
o.
o.
o.

s.11 o.

o.
o.
o.
o.
o.
o.
o.
o.
o.

WNW 1.80 2.06,:'.t:! 1 o.

c,.

u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

N\ot 1.94 1.tl 0 2. 1.. o.

o.
o.
o.
o.
u.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

NNW 1.57 l... 5 2.3.. 3.0J o.

u.
o.
o.

(J.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

I.SJ l *'- 7 1.13 1. JI I.36 l

  • l ',I o.

l.26 o.

o.
o.
o.
o.

o.

o.
o.
o.
o.
o.
o.
o.
o.
o.
o.

TOTAL NO. Of" Qtj5t.WVAT IONS = 350'>4 Rev. 35, 07 /84

1 2

TABLE 2.3-17 LONG TERM TEMPERATURE {°F) AT WILKES-BARRE SCRANTON AIRPORT I

3 4

5 6

Averages Extreme Daily Daily Month Max.

Min.

Mean Highest January 32.3 17.7 25.0 67 February 34.7 19.0 26.9 71 March 45.4 28.1 36.8 83 April 58.1 38.1 48.1 92 May 69.6 48.3 58.9 91 June 77.8 56.8 67.3 97 July 82.2 61.8 72.0 101 August 80.1 60.2 70.1 95 September 72.2 52.6 62.4 95*

October 61.1 41.9 51.5 83 November 48.8 33.8 41.3 80 December 36.8 23.5 30.2 67 Annual 58.3 40.2 49.2 101 Temperature averages are based on a 36-year climatological period from 1961-1996.

Temperature extremes are for the 43 year period from 1954-1995.

Sources:

Pennsylvania State Climatologist (Ref. 2.3-5a)

Lowest

-21

-16

-4

-+14

+27

+34

+43

+38

-+30

+19

+9

.g

-21 National Oceanic and Atmospheric Administration Cooperative Institute for Research in Environmental Sciences, Climate Diagnostic Center (Ref. 2.3-3a) (NOANCIRES/CDC)

Rev. 54, 10/99 Page 1 of 1

Month January February March April May June July August September October November December Annual SSES -

FSAR TABLE 2.3-18 MEAN MONTHLY TEMPERATURE, DEW POINT*

TEMPERATURE, AND RELATIVE HUMIDITY WILKES-BARRE SCRANTON AIRPORT (Ref. 2.3-3)

Period of Records:

1956-1974 Temperature *F Dew Point "F 26 18 27 18 36 26 49 37 59 47 68 58 72 62 70 61 63 55 53 44 41 33 29 21 49 40 RH (%)

70 69 67 62 64 70 70 73 76 72 72 73 70

  • Dew point temperatures computed from temperature and relative humidity measurements.

Rev. 48, 12/94

Month January February March April May June July August September October November December Annual Rev. 48, 12/94 SSES - FSAR TABLE 2. 3-19 TEMPERATURE AND MOISTURE DATA FOR THE SUSQUEHANNA SITE Period of Record:

1973-1976 Dry Bulb c *c)

Average Average Max Min Wet Bulb

(

  • C)

-2.1 18.5

-20.9

-3.6

-1.4 18.7

-18.5

-3.4 3.6 22.2

-11.2 1.1 8.8 32.5

-6.l 5.2 13.8 30.6

-1.9 10.6 18.8 31.9 5,6 16.1 20,3 31.7 7,8 17.7 20.0 34.3 4.8 17.7 15.0 31.8

-0.8 12.9 9.9 27.8

-6.4 7.6 4.9 23.1

-14,0 2.6

-0,9 17.8

-19.0

-2.6 9.3 34.3

-20.9 6.9 R.H.

66 61 62 60 70 76 79 82 Bl 72 67 66 70

SSES -

FSAR Pagel of 2 TABLE 2.3-20 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JANUARY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

67.9

-4.2

-2.8 2

68.5

-4.4

-3.l 3

68.8

-4.5

-3.2 4

68.9

-4.7

-3.4 5

68.7

-4.8

-3.6 6

68.4

-5.1

-3.8 7

68.8

-5.3

-4.1 8

69.2

-5.4

-4.2 9

69.6

-5.1

-4.0 10 68.8

-4.3

-3.0 11 66.3

-3.5

-2.0 12 63.6

-2.8

-1.1 13 61.7

-2.3

-.4 14 60.6

-1.9

.1 15 60.0

-1.6

.5 16 59.6

-1.6

.6 17 60.l

-1.9

.2 18 61.7

-2.3

-.4 19 63.6

-2.7

-1.0 20 64.8

-3.1

-1.5 21 65.5

-3.4

-1.9 22 65.7

-3.8

-2.2 23 65.9

-4.0

-2.6 24 66.6

-4.3

-2.9 Rev. 48, 12/94

SSES - FSAR Page 2 of 2 TABLE 2.3-20 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JANUARY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOWTE MAX 98.5 16.4 18.5 AVG DAILY MAX 78.3

-.2 1.9 MEAN 65.6

-3.6

-2.1 CLIMATIC MEAN 65.1

-3.7

-2.2 AVG DAILY MIN 52.0

-7.3

-6.2 ABSOLUTE MIN 3.2

-21.6

-20.9 STANDARD DEV 17.9 6.0 6.2 VALID OBS 2975 2975 2975 I

INVALID OBS l

1 1

TOTAL OBS 2976 2976 2976 DATA RECOVERY 100.0 100.0 100.0 Rev. 48, 12/94

SSES - FSAR Page 1 of 2 TABLE 2.3-21 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

FEBRUARY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

64.8

-4.4

-2.9 2

65.2

-4.6

-3.l 3

65.4

-4.9

-3.4 4

66.3

-5.1

-3.7 5

66.5

-5.4

-4.0 6

66.8

-5.5

-4.2 7

66.8

-5.7

-4.4 8

67.4

-5.6

-4.4 9

67.3

-s.o

-3.6 10 64.0

-4.0

-2.4 11 60.0

-3.0

-1.0 12 57.4

-2.2

.2 13 54.7

-1. 7 1.0 14 53.2

-1.2 1.7 15 53.1

-.9 2.1 16 52.6

-.8 2.2 17 53.0

-.9 2.0 18 54.4

-1.4 1.4 19 56.7

-2.0

.5 20 59.2

-2.5

-.3 21 61.2

-2.9

-.9 22 62.8

-3.2

-1.4 23 64.1

-3.6

-1.9 24 65.1

-3.9

-2.4 Rev. 48, 12/94

SSES.. FSAR Page 2 of 2 TABLE 2.3-21 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

FEBRUARY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOLUTE MAX 100.0 14.2

18. 7 AVG DAILY MAX 76.9

.3 3.2 MEAN 61.2

-3.4

-1.4 CLIMATIC MEAN 61.5

-3.6

-1.s AVG DAILY MIN 46.0

-7.4

-6.2 ABSOLUTE MIN 13.7

-18.9

-18.5 STANDARD DEV 17.0 5.9 6.5 VALID OBS 2712 2712 2712 INVALID OBS 0

0 0

TOTAL OBS 2712 2712 2712 DATA RECOVERY 100.0 100.0 100.0 Rev. 48, 12/94

SSES -

FSAR Page 1 of 2 TABLE 2.3-22 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

MARCH 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

66.1

-.1 1.9 2

66.7

-.3 1.6 3

67.4

-.5 1.3 4

67.9

-.7 1.1 5

68.3

-.9

.9 6

68.6

-1.0

.7 7

69.2

-1.0

.6 8

69.3

-.7

.9 9

66.9

-.1 1.8 10 63.4

.8 3.0 11 60.5 1.5 4.1 12 57.8 2.2 5.2 13 55.9 2.7 6.0 14

  • 54. 7 3.1 6.6 15 54.2 3.5 7.2 16 54.3 3.6 7.3 17 54.0 3.5 7.2 18 54.8 3.1 6.6 19 56.7 2.5 5.8 20 59.1 1.9 4.8 21 60.9 1.4 4.0 22 62.3

.9 3.3 23 63.9

.s 2.8 24 65.1

.2 2.3 Rev. 48, 12/94

SSES - FSAR Page 2 of 2 TABLE 2.3-22 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

MARCH 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOLUTE MAX 100.0 20.8 22.2 AVG DAILY MAX 77.7 4.6 8.3 MEAN 62.0 1.1 J.6 CLIMATIC MEAN 62.3 1.0 3.6 AVG DAILY MIN 47.0

-2.6

-1.0 ABSOLUTE MIN 18.8

-12.2

-11.2 STANDARD DEV 18.1 5.2 5.8 VALID OBS 2925 2925 2925 INVALID OBS 51 51 51 TOTAL OBS 2976 2976 2976 DATA RECOVERY 98.3 98.3 98.3 Rev. 48, 12/94

SSES -

FSAR Pagel of 2 TABLE 2.3-23 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

APRIL 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

66.7 3.7 6.1 2

68.l 3.3 5.6 3

69.5 3.0 5.1 4

70.8 2.7 4.7 5

71.9 2.4 4.2 6

72.8 2.2 4.0 7

72.5 2.5 4.4 8

69.6 3.6 5.8 9

63.9 4.7 7.5 10 58.7 5.4 9.0 11 55.6 6.2 10.3 12 52.9 6.7 11.3 13 51.4 7.2 12.l 14 49.9 7.6 12.7 15 49.4 7.8 13.1 16 49.0 7.9 13.3 17 49.1 7.8 13.2 18 49.5 7.5 12,7 19 50.9 7.0 11.8 20 53.9 6.4 10.7 21 56.8 5.8 9.6 22 59.8 5.2 8.5 23

62. 2 4.7 7.7 24 64.7 4.2 6.9 Rev. 48, 12/94

SSES -

FSAR Page 2 of 2 TABLE 2.3-23 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

APRIL 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOLUTE MAX 97.9 20.0 32.5 AVG DAILY MAX 77.9 8.7 14.2 MEAN 60.0 5.2 8.8 CLIMATIC MEAN 60.7 4.9 8.6 AVG DAILY MIN 43.6 1.0 2.9 ABSOWTE MIN 10.0

-7.8

-6.1 STANDARD DEV 18.6 5.8 7.1 VALID OBS 2878 2878 2878 INVALID OBS 2

2 2

TOTAL OBS 2880 2880 2880 DATA RECOVERY 99.9 99.9 99.9 Rev. 48, 12/94

SSES - FSAR Page 1 of 2 TABLE 2.3-24 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

MAY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

76.5 9.1 11.2 2

77.6 8.7 10.6 3

78.4.

8.3 10.2 4

79.4 8.1 9.8 5

80.0 7.8 9.5 6

81.l 7.7 9.3 7

81.0 8.1 9.7 8

78.4 9.1 11.0 9

73.4 10.2 12.7 10 69.3 11.0 14.1 11 65.7 11.7 15.3 12 63.3 12.2 16.2 13 60.6 12.6 17.1 14 58.9 13.0 17.8 15 57.6 13.2 18.2 16 57.5 13.2 18.2 17 58.2 13.0 17.9 18 59.5 12.7 17.4 19 61.3 12.4 16.7 20 63.7 11.8 15.7 21 67.2 11.3 14.6 22 70.7 10.7 13.5 23 73.4 10.1 12.6 24 75.2 9.7 11.9 Rev. 48, 12/94

SSES -

FSAR Page 2 of 2 TABLE 2.3-24 STATISTICS ANO DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

MAY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

ABSOWTE MAX 100.0 30.6 30.6 AVG DAILY MAX 85.8 14.0 19.2 MEAN 69.5 10.6 13.8 CLIMATIC MEAN 69.0 10.3 13.7 AVG DAILY MIN 52.l 6.6 8.1 ABSOWTE MIN 20.7

-3.3

-1.9 STANDARD DEV 18.l 5.1 5.9 VALID OBS 2964 2964 2964 INVALID OBS 12 12 12 TOTAL OBS 2976 2976 2976 DATA RECOVERY 99.6 99.6 99.6 Rev. 48, 12/94

SSES -

FSAR Pagel of 2 TABLE 2.3-25 STATISTICAL AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JUNE 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

85.1 14.4 15.8 2

85.9 14.0 15.4 3

86.5 13.8 15.l 4

86.8 13.5 14.8 5

87.1 13.3 14.6 6

88.0 13.4 14.6 7

87.6 14.0 15.2 8

85.4 15.0 16.4 9

80.8 15.9 18.0 10 75.4 16.7 19.5 11 70.9 17.4 20.9 12 67.7 17.8 21.8 13 64.9 18.0 22.6 14 64.0 18.2 22.9 15 63.6 18.4 23.2 16 63.2 18.4 23.3 17 63.4 18.3 23.2 18 64.8 18.0 22.6 19 67.5 17.6 21.7 20 71.3 17.0 20.5 21 76.6 16.4 19.0 22 80.4 15.7 17.9 23 83.0 15.3 17.0 24 84.0 14.8 16.4 Rev. 48, 12/94

SSES -

FSAR Page 2 of 2 TABLE 2.3-25 STATISTICAL AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JUNE 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY lWMID BULB BULB ABSOLUTE MAX 100.0 27.2 31.9 AVG DAILY MAX 90.5 19.0 24.0 MEAN 76.4 16.l 18.8 CLIMATIC MEAN 74.7 15.8 18.9 AVG DAILY MIN 58.8 12.6 13.9 ABSOLUTE MIN 17.3 3.9 5.6 STANDARD DEV 15.8 4.0 4.7 VALID OBS 2876 2876 2876 INVALID OBS 4

4 4

TOTAL OBS 2880 2880 2880 DATA RECOVERY 99.9 99.9 99.9 Rev. 48, 12/94

SSES - FSAR Pagel of 2 TABLE 2.3-26 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JULY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C l

88.9 15.9 17.l 2

89.5 15.6 16.6 3

89.6 15.3 16.3 4

89.7 15.0 16.0 5

90.2 14.7 15.7 6

90.8 14.7 15.7 7

90.8 15.3 16.2 8

88.6 16.3 17.5 9

84.0 17.4 19.2 10 77.6 18.4

21. 0 11 72.9 19.0 22.4 12 69.4 19.5 23.4 13 66.7 19.8 24.2 14 64.3 20.0 24.8 15 63.3 20.1 25.2 16 63.2 20.2 25.3 17 64.0 20.1 25.0 18 66.1 19.9 24.5 19 69.6 19.7 23.7 20 74.9 19.0 22.1 21 81.0 18.l 20.3 22 84.4 17.5 19.2 23 86.3 16.9 18.4 24 87.6 16.4 17.7 Rev. 48, 12/94

SSE$ - FSAR Page 2 of 2 TABLE 2.3-26 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JULY 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET.

DRY HUMID BULB BULB ABSOWTE MAX 100.0 25.7 31.7 AVG DAILY MAX 94.0 20.8 26.0 MEAN 78.9 17.7 20.3 CLIMATIC MEAN 76.9 17.5 20.5 AVG DAILY MIN 59.9 14.1 15.l ABSOWTE MIN 30.9 6.9 7.8 STANDARD DEV 14.9 3.5 4.5 VALID OBS 2970 2970 2975 INVALID OBS 6

6 1

TOTAL OBS 2976 2976 2976 DATA RECOVERY 99.8 99.8 100.0 Rev. 48, 12/94

SSES - FSAR Pagel of 2 TABLE 2.3-27 STATISTICS ANO DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

AUGUST 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C l

91.4 16.2 17.l 2

91.7 15.8 16.7 3

92.0 15.5 16.3 4

92.5 15.3 16.l 5

92.5 15.1 15.9 6

92.9 15.0 15.7 7

93.2 15.2 15.9 8

92.4 16.l 16.8 9

88.2 17.2

~

18.5 10 81.6 18.3 20.4 11 75.6 19.2 22.1 12 70.5 19.7 23.5 13 67.3 20.0 24.4 14 65.5 20.3 24.9 15 65.0 20.3 25.0 16 65.2 20.2 24.9 17 66.3 20.0 24.6 18 68.9 19.8 23.9 19 73.6 19.4 22.7 20 80.5 18.7 20.9 21 85.3 17.9 19.6 22 87.8 17.4 18.7 23 89.5 16.8 17.9 24 90.7 16.5 17.4 Rev. 48, 12/94

SSES -

FSAR Page 2 of 2 TABLE 2.3-27 STATISTICS ANO DIURNAL VARIATION OF.METEOROLOGICAL PARAMETERS DATA PERIOD:

AUGUST 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOLUTE MAX 100.0 26.8 34.3 AVG DAILY MAX 95.0 20.8 25.8 MEAN 81.7 17.7 20.0 CLIMATIC MEAN 78.2 17.6 20.4 AVG DAILY MIN 61.4 14.3 15.1 ABSOLUTE MIN 28.l 3.9 4.8 STANDARD DEV 14.6 3.7 4.7 VALID OBS 2970 2970 2972 INVALID OBS 6

6 4

TOTAL OBS 2976 2976 2976 DATA RECOVERY 99.8 99.8 99.9 Rev. 48, 12/94

SSES - FSAR Pagel of 2 TABLE 2.3-28 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

SEPTEMBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET ORY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

88.6 11.4 12.5 2

88.9 11.2 12.1 3

89.5 10.9 11.8 4

89.5 10.7 11.6 5

89.6 10.5 11.4 6

90.0 10.4 11.3 7

90.6 10.4 11.2 8

90.6 11.0 11.8 9

88.2

12. 0 13.1 10 82.7 13.l 14.8 11 76.3 14.1 16.6 12 70.9 14.8 18.1 13 67.2 15.2 19.0 14 65.3 15.4 19.6 15 64.2 15.5 19.8 16 64.4 15.5 19.8 17 65.7 15.3 19.4 18 69.2 14.9 18.5 19 75.2 14.3 16.9 20 80.5 13.6 15.5 21 84.2 13.0
14. 5 22 85.6 12.4 13.8 23 87.l 12.0 13.2 24 88.1 11.6 12.7 Rev. 48, 12/94

SSES -

FSAR Page 2 of 2 TABLE 2.3-28 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

SEPTEMBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DR'i HUMID BULB BULB ABSOLUTE MAX 99.0 25.7 31.8 AVG DAILY MAX 93.3 16.3 20.S MEAN 80.5 12.9 15.0 CLIMATIC MEAN 77.3 12.6 15.2 AVG DAILY MIN 61.3 9.0 9.8 ABSOLUTE MIN 28.4

-1.2

-.8 STANDARD DEV 14.9 4.6 5.3 VALID OBS 2875 2875 2875 INVALID OBS 5

5 5

TOTAL OBS 2880 2880 2880 DATA RECOVERY 99.8 99.8 99.8 Rev. 48, 12/94

SSES -

FSAR Page 1 of 2 TABLE 2.3-29 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

OCTOBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

79.6 6.2 7.7 2

80.2 5.9 7.2 3

80.5 5.6 6.9 4

80.9 5.3 6.5 5

80.9 5.1 6.3 6

81.3 4.9 6.1 7

82.0 4.8 5.8 8

82.6 5.2 6.3 9

80.5 6.3 7.7 10 75.0 7.7 9.6 11 69.1 8.7 11.4 12 64.7 9.5 12.9 13 61.9 9.9 13.8 14 59.7 10.4 14.6 15 58.5 10.5 14.9 16 58.3 10.5 15.0 17 59.5 10.2 14.4 18 62.3 9.6 13.3 19 66.5 8.9 11.9 20 70.8 8.2 10.7 21 73.9 7.7 9.8 22

75. 7 7.2 9.0 23 76.9 6.8 8.6 24 78.6 6.4 8.0 Rev. 48, 12/94

SSES -

FSAR Page 2 of 2 TABLE 2.3.. 29 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

OCTOBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOLUTE MAX 100.0 20.7 27.8 AVG DAILY MAX 86.2 ll.3 15.5 MEAN 72.4 7.6 9.9 CLIMATIC MEAN 70.8 7.5 10.1 AVG DAILY MIN 55.4 3.6 4.7 ABSOLUTE MIN 22.9

-7.9

-6.4 STANDARD DEV 17.4 5.6 6.0 VALID OBS 2706 2706 2975 INVALID OBS 270 270 1

TOTAL OBS 2976 2976 2976 DATA RECOVERY 90.9 90.9 100.0 Rev. 48, 12/94

ssts - FSAR Page 1 of 2 TABLE 2. 3-30 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

NOVEMBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

70.2 1.6 3.5 2

71.0 1.4 3.2 3

71.2 1.2 2.9 4

71.6 1.0 2.6 5

72.0

.8 2.4 6

72.2

.6 2.2 7

72.6

.5 2.0 8

73.4

.5 2.0 9

73.2 l.2 2.8 10 71.0 2.3 4.2 11 67.0 3.4 5.8 12 63.5 4.2 7.0 13 60.5 4.7 7.9 14 58.9 5.0 8.4 15 57.7 5.1 8.7 16 57.4 5.1 8.6 17 58.4 4.7 8.0 18 59.9 4.1 7.1 19 62.3 3.5 6.3 20 64.6 3.0 5.4 21 66.1 2.5 4.8 22 67.l 2.2 4.3 23 68.0 1.9 4.0 24 68.8 l.7 3.6 Rev. 48, 12/94

SSES - FSAR Page 2 of 2 TABLE 2.3-30 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

NOVEMBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOWTE MAX 100.0 19.4 23.l AVG DAILY MAX 79.0 6.1 9.4 MEAN 66.6 2.6 4.9 CLIMATIC MEAN 65.9 2.5 4.9 AVG DAILY MIN 52.8

-1.l

.5 ABSOWTE MIN 21.1

-15.4

-14.0 STANDARD DEV 17.7 6.0 6.3 VALID OBS 2873 2873 2880 INVALID OBS 7

7 7

TOTAL OBS 2880 2880 2880 DATA RECOVERY 99.8 99.8 100.0 Rev. 48, 12/94

SSES -

FSAR Page 1 of 2 TABLE 2.3-31 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

DECEMBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C l

68.4

-3.2

-1.8 2

68.8

-3.3

-1.9 3

68.9

-3.4

-2.1 4

68.8

-3.5

-2.2 5

68.7

-3.6

-2.3 6

68.8

-3.7

-2.4 7

68.9

-3.9

-2.6 8

68.5

-4.0

-2.7 9

68.5

-3.9

-2.5 10 68.3

-3.1

-1.6 11 66.3

-2.2

-.6 12 63.9

-1.6

  • 3 13 62.5

-1.1 1.0 14 60.7

-.9 1.4 15 59.6

-.6 1.8 16 59.4

-.8 1.6 17 59.7

-1.2 1.1 18 61.2

-1.6

.4 19 63.0

-2.0

-.l 20 64.9

-2.3

-.6 21 66.1

-2.6

-1.0 22 66.9

-2.e

-1.3 23 67.6

-3.0

-1.5 24 68.2

-3.2

-1.8 Rev. 48, 12/94

SSES - FSAR Page 2 of 2 TABLE 2.3-31 STATISTICS ANO DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

DECEMBER 1973-1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY JWMID BULB BULB ABSOWTE MAX 100.0 16.4 17.8 AVG DAILY MAX 79,2

.8 2,9 MEAN 65,7

-2.6

-.9 CLIMATIC MEAN 66.1

-2.7

-1.0 AVG DAILY MIN 52.9

-6.l

-4.8 ABSOLUTE MIN 7.9

-20.2

-19.0 STANDARD DEV 18.8 5.4 5.4 VALID OBS 2849 2849 2853 INVALID OBS 127 127 123 TOTAL OBS 2976 2976 2976 DATA RECOVERY 95.7 95.7 95.9 Rev. 48, 12/94

SSES -

FSAR Page 1 of 2 TABLE 2.3-32 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JANUARY 1973 -

DECEMBER 1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB 9.61 9.61 9.61 HOUR PCT DEG C DEG C 1

76.3 5.6 7.2 2

76.9 5.4 6.8 3

77.4 5.1 6.5 4

77.8 4.9 6.2 5

78.1 4.7 6.0 6

78.5 4.5 5.8 7

78.7 4.7 5.9 8

78.0 5.2 6.5 9

75.4 6.0 7.7 10 71.3 6.9 9.2 11 67.2 7.8 10.5 12 63.8 8.4 11.6 13 61.3 8.9 12.5 14 59.7 9.2 13.l 15 58.9 9.4 13.4 16 58.7 9.4 13.4 17 59.3 9.2 13.1 18 61.1 8.8 12.4 19 64.0 8.3 11.5 20 67.4 7.7 10.4 21 70.5 7.2 9.5 22 72.5 6.7 8.7 23 74.1 6.3 8.1 24 75.3 5.9 7.6 Rev. 48, 12/94

L SSES - FSAR Page 2 of 2 TABLE 2.3-32 STATISTICS AND DIURNAL VARIATION OF METEOROLOGICAL PARAMETERS DATA PERIOD:

JANUARY 1973 -

DECEMBER 1976 METEOROLOGICAL PARAMETERS (HEIGHTS IN METERS)

REL WET DRY HUMID BULB BULB ABSOLUTE MAX 100.0 30.6 34.3 AVG DAILY MAX 84.5 10.3 14.3 MEAN 70.l 6.9 9.3 CLIMATIC MEAN 69.l 6.7 9.4 AVG DAILY MIN 53.6 3.1 4.4 ABSOLUTE MIN 3.2

-21.6

-20.9 STANDARD DEV 18.6 9.4 9.9 VALID OBS 34573 34573 34860 INVALID OBS 491 491 204 TOTAL OBS 35064 35064 35064 DATA RECOVERY 98.6 98.6 99.4 Rev. 48, 12/94

SSES-FSAR TABLE 2.3-33 LONG TERM MONTHLY PRECIPITATION DATA (LIQUID EQUIVALENT, IN INCHES)

FOR THE WILKES-BARRE SCRANTON AIRPORT AT AVOCA. PA.

MONTH MEAN GREATEST 24-HOUR January 2.23 1.89 February 2.01 3.11 March 2.60 3.02 April 3.15 3.80 May 3.50 2.58 June 3.70 3.61 July 3.70 2.45 August 3.27 3.18 September 3.40 6.52 October 2.89 3.27 November 3.20 2.91 December 2.58 2.86 Annual 36.23 Precipitation means are based on a 36 year climatological period from 1961-1996. Greatest 24-hour rainfall amounts are for a 38 year period from 1953-1990.

Sources:

National Oceanic Atmospheric Administration, Cooperative Institute for Research in Environmental Science, Climate Diagnostic Center (NO44/CIRES/CDC) Ref. 2.3-3a National Oceanic and Atmospheric Administration, Local Climatological Data, Annual Summary with Comparitive Data, Avoca, PA (Ref. 2.3-3)

Rev. 54, 10/99 Page 1 of 1 I

SSES -

FSAR TABLE 2. 3-34 EXPECTED RAINFALL BY DURATION AND RECURRENCE INTERVAL FOR VICINITY OF SUSQUEHANNA SITE (Ref. 2.3-20) (INCHES)

RECURRENCE INTERVAL 100 DURATION l YR 2 YR 5 YR 10 YR 25 YR 50 YR YR 1 Hour 1.1 l.4 1.6 2.0 2.2 2.s 2.8 2 Hour 1.4 1.6 2.1 2.5 2.8 3.2 3.5 J Hour l.4 1.8 2.3 2.7 3.1 3.5 3.8 6 Hour 1.8 2.2 2.8 3.3 3.9 4.2 4.8 12 Hour 2.2 2.7 3.4 4.0 4.7 5.0 5.8 24 Hour 2.5 3.0 4.0 4.7 5.3 6.0 6.8 Rev. 48, 12/94

SSES -

FSAR TABLE 2.3-35 PROBABLE MAXIMUM PRECIPITATION FOR VARYING RAINFALL DURATIONS AND AREAS (Ref. 2.3-21) (INCHES)

AREA DURATION (HOURS)

(Mi2) 6 12 24 48 72 10 25.5 29.5 31.0 35.0 36.5 200 17.0 20.s 23.0 26.0 27.0 Rev. 48, 12/94

January February March April May June July August September October November December Annual SSES - FSAR TABLE 2.3-36 PRECIPITATION DATA FOR THE SUSQUEHANNA SITE (Inches of Water)

(1973-1976)

KON'l'B TOTAL 3.68 2.53 3.67 3.73 4.19 4.82 4.73 3.59 7.54 4.40 2.76 2.21 47.83 Rev. 48, 12/94

TABLE 2.3-37 FREQUENCY DISTRIBUTION OF PRECEIPITATION DATA PERIOD: JANUARY 1973-1976 PRECIPITATION FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY CLASS INTERVAL DISTRIBITION OF DISTRIBITION OF Dl$TRIBIT1ON OF DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF (INCHES)

PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRE;:CIPITATION PRECIPITATION 1 HOUR DURATION 2 HOUR DURATION 3 HOUR DURATION 6 HOUR DURATION 12 HOUR DURATION 24 HOUR DURATION

.0 TO

.1 190 89.20 34 45.95 0

0.00 0

0.00 0

0.00 0

0.00

.1 TO

.2 15 7.04 33 44.59 28 75.68 0

0.00 0

0.00 0

0.00

.2 TO

.3 3

1.,41 2

2.70 5

13.51 3

27.27 0

0.00 0

0.00 3

TO

.4 2

.94 2

2.70 2

5.41 6

54.55 0

0.00 0

0.00

.4 TO

.5 1

.47 0

0.00 1

2.70 0

0.00 0

0.00 0

0.00

.5 TO

.6 0

0.00 1

1.35 1

2.70 1

9.09 0

0.00 0

0.00

.6 TO

.7 1

.47 0

0.00 0

0.00 0

0.00 0

. 0.00 0

0.00

.7 TO

.8 0

0.00 0

0.00 0

0.00 0

0.00 0

  • o.oo 0

o.oo

.8 TO

.9 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00

.9 TO 1.0 1

.47 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.0 TO 1.1 0

0.00 1

1.35 0

0.00 0

0.00 0

000 0

000 1.1 TO 1.2 0

0.00 0

0.00 0

0.00 0

0.00 1

50.00 0

0.00 1.2 TO 1.3 0

0.00 1

1.35 0

0.00 0

0.00 0

0.00 0

0.00 1.3 TO 1.4 0

0.00

. o 0.00 0

000 0

0.00 0

0.00 0

0.00 1.4 TO 1.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.5 TO 1.6 0

0.00 0

0.00 0

0.00 0

0.09....,

0 0.00 0

0.00 1.6 TO 1.7 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.7 TO 1.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.8 TO 1.9 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 1.9 TO 2.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.0 TO 2.2 0

0.00 0

0.00 0

0.00 0

0,00 0

0.00 0

0.00 2.2 TO 2.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.4 TO 2.6 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 0

0.00 2.6 TO 2.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.8 TO 3.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.0 TO 3.2 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.2 TO 3.4 0

0.00 0

o.oo 0

0.00 0

0.00 0

0.00 0

0.00 3.4 TO 3.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.6 TO 3.8 0

0.00 0

0.00 0

0.00 0

0.00 0

000 0

0.00 3.8 TO 4.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.0 TO 4.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.5 TO 5.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.0 TO 5.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.5 TO 6.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

000 6.0 TO 6.S 0

0.00 0

0.00 0

0.00 0

0.00 0

000 0

0.00 6.5 TO 7.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 7.0 TO 7.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.0 7.5 TO 8.0 0

0.00 0

0.00 0

0.00 0

0.00-...

0 0.00 0

000 8.0 TO 90 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 9.0 TO 10.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 10.0 TO 11.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 11.0 TO 12.0 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 0

0.00 GT 12.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 TOTAL 21 3 100.00 74 100.00 37 100.00 11 100,00 2

100.00 o

000 MAXIMUM AMT.

.91 1 30

.60

.76 1.12 0.00 TOTAL PRECIPITATION FOR DATA PERIOD 14.71 INCHES NO.

PCT.

NO.

PCT.

OBSERVATIONS WITH NO PRECIPITATION 2763 92.84 VALID OBSERVATIONS 2976 100.00 OBSERVATIONS WITH PRECIPITATION GE O 01NCH

?.1 3 7.16 INVALID OBSERVATIONS o

0.00 TOTAL VALID OBSERVATIONS 2976 100.00 TOTAL OBSERVATIONS 2976 100.00 Rev. 35, 07/84

TABLE 2.3-38 PR!!)QOEMCY DISTRIBUTION OP PRZCIPITATIOR DATA PERIOD:

FEBRUARY 1973-1976 PRECIPITATION FREOWfNCY FREQUENCY FREQUENCY FR£0~NCY FREQUENCY F'REfflNCY fb~liVAl i DllT eyrJro Of" 01irR1yvrlro or BlSTRifVTJON Of" BU~1itvn~Of" Bi1~1i,vnrONOf" B.\l~1iY¥nr°"°'

PR CIPI A ON PR CIP A ON Rf:CIP A ION f lNCHESI l HrfR 2 HOYA 3 HOUR O~R~ON 12 ~

Z4 ~

OURAT ON OURAT ON OVRATION OURAf ON OURAT ON eO TO NO.

Per.

NO.

PCT.

NOO PCT.

NOO PCT.

HOO PCT.

NO.

PCTe

.1 155 88.07 37 60.66 o.oo o.oo o.oo 0

o.oo

1 l8 :J 19 10.80 19 Jl.15 Zit 81.76 g

8:g8 8

8:88 8

8:88 2

l

  • l 1t 2

J.28 1

.45

.3 TO 0

o.oo J

4.92 J

1 *.)4 t

60. 0 0

o.oo 0

.oo

.It TO

.s 0

o.oo 0

o.oo 0

o.oo o.oo 0

o.go 0

o.oo

.s TO

.6 0

o.og 0

o.oo l

3.45 l

10.00 0

o. 8 8

8.oo

.6 TO

.1 0

o.o 0

o.oo 0

o.oo l

o.oo 0

o.o

-10

.7 TO

.a 0

o.og 0

o.oo 0

8:88 g

8.oo 8

8.oo 0

3: 8 8 TO

.9 0

o.o 0

o.oo 0

.oo

.oo 0

e9 TO HI 0

o.oo 0

o.oo 0

o.oo 0

8:g8 f

o.g!

8 8:88 l*g TO 0

o.oo 0

o.oo 0

o.oo 0

108:8 TO 0

8:88 0

g.oo 0

8.oo 0

8. 0 0

8:88 TO 0

0

.oo 0

.oo 0

.oo 0

l.J T8 l.4 0

o.oo 0

o.oo 8

8:88 8

g.oo 8

8.oo 8

8:88

  • '- T

.s 0

o.oo 0

o.oo

.oo

.oo l.5 TO 1.,

0 8:88 0

o.oo 8

8.oo 8

8:88 8

8:88 8

8:88

.6 TO

1.

0 0

o.oo

.oo 1

.7 JO l.e 0

8:88 0

o.oo 0

8:88 8

8:88 I ur I

8:88

, :~ t8

.9 0

0 g.oo 0

j 0

o.go 0

.og 0

8:8° g

8:H l:H -

IJ TO 0

o. 0 0

o:g 8

0.08 1

.4 0

o.oo 0

.4 T8

.6 0

o.oo 0

o. 0 0

8.oo 0

o.oo 0.01 0

o.oo 6 T

.e 0

o.og 8

o.go 8

88 8

8:88 8

o.o 8

8:88

.e TO

.o 0

o.o

o. 0 o.oo e

):! f8 1

.2 0

8:88 8

8:°I 0

i~H 8

i~H g

i~H 8

&:88 0

0

.6 18

.6 0

o.go 0

o.8 0

8 g

8 3:8&

.a 0

o. 0 0

0 J.8. TO **i 0

o.oo 0

o.oo 0

o.oo 8 !.oo 0

o.oo 0

g.oo

    • i TO...

8 8:88 0

o.oo 0

o.oo

.og 0

o.oi 0

.og Tg i:~

0 8:88 0

8.oo 0

o:8 g

8:8 8:0 s.3 T 8

8.oo 0

0

.go 0

oJo

5.

T 6.0

.oo 0

0

o. 0 0

o.oo o.o t*g TO '.s 8

8:38 8

8:88 I 1

88 0 1:8!

I 1:88 i 1

\11 ro

.o 0

J*~ TO 7.S 8

0.08 0

o.og

88 8
88

.go T§ t*O 8:8 0

g.o

08 8.0 T

.O 0

0

.oo 0

q.8 l io.g 8

8:88 0

o.go 8

8:88 0

8:8f I l~H

=11 lo.

o 1i*

0

o. 0 0

1.0 TV

.o 0

o.og 0

o.og 8

8:88 0

o.o 8

G 1.O 0

o.o 0

o.o 0

o.oo

  • 0 TOTAL 116 100.00 61 100.00 29 100.00 5

100.00 1

100.00 0

o.oo MAXIMUM AMT.

.18

.40

.S2

.64 1.16 o.oo TOTAL PAtC!PITATION FOR DATA P[RIOO l0el2 INCi'$

m PCT'

,'!i PCT miAV*'l~ VJ'" :hmflPITATI~

.,.5 J5¥!t*tlH:ff*

r'CI oru:vAT ~

TATION 0.01 INCH :t, 10.oo Rev. 35, 07/84

' TABLP.! 2.3-39 PR!!QUBRCY DISTRIBUTION 01' PRECIPITATION DATA PEJUOO:

MARCH 1973-1976 PR!ClPifATlON FRE:O~NCY FREO~ENCY f'REfflNCY f'REQ~NCY n,Eo~NCT f'AEMNCY

~:av*L :

OijT lBUTION Of" OltT I,VTION Of" 01ST 18¥TfON Of' our YVTJOM Of' mi1 rvnrONOf' uii,,vnrONOF P ClPIUTJON PR CIPl ATlON PkEClPl A ION P CIP A ION CIMCH£S) t Mm 2 HOYR

~ffi'RON 6ffiA A~ffl"'ON

~ffl"'OM DUAAT Oltf OUAAT ON OURAT ON

~,

PCJ N~t PCT.

NO.

PCTI NOg PCTO flfOg PCTO flf06 PCT.

.o TO

.1 84 *.)

46.38 0

o.o o.o o.o o.oo

  • i TO

.2 33 14.~

16.ZJ 11 40.74 g

o.oo 0

o.oo 0

8:8°

  • '8

.J

.4 e

~.59 8

rs9:tl o.oo g s:H 8

T

.4 o.o 4

.,o 1

o.oo i:g3 YO

.s 0

o.oo 0

o. 0

.41 z

40.00

.08

.5 TO

.6 0

o.oo 0

o.oo 1

J.1g A

zg.oo 8

8.oo g

.6 TO

.1 0

o.oo 0

o.oo 0

o.o

.oo

.oo

.og

.1 T8

.e 8

o.oo 0

o.oo 0

8.oo 2

48:88 8

8:88 8

8.o

.8 T

.9 o.oo 0

o.oo 0

.oo 0

.oo

.9 TO !:?

0 o.go 8

o.oo 0

&:88 0

8:11 0

UH 0

i;H l*J TO 0

o. ~

o.oo 0

0 8

0 T8 l:i l

0 o.go 0

8:88 I

8:8 8

T 0

o.oo 0

o. 0 0

l

.J T8 1.4 0

i~H 0

o.oo 0

HH 8:88 i

8:81 i l~H

  • '- T l.s 0

0 8:88 0

.s TO

=~

8 0

0 8

8:83 8.o

.6 TO 0

o.oo 0

.o 1

.7 T§ l

.8 0

o.oo 0

o.oo 0

g.oo 0

UH 0

u11 i i:og

  • S,

.9 0

o.oo 0

o.oo 0

8:88 s

8 T

j g

g.oo 8

8:88 0

  • is

.o TO

.oo 0

0.08 o: 0

{Ill 1.2 TO I..,.

0 o.oo 0

o.oo 0

0 8

=

.4 TO

=~

0 g.oo 0

o.oo 0

o.oo 0

8.oo

g. 0 o.oo 2:i 18 0

.oo 0

o.oo 0

8.oo 0

.oo 8

g Z:38 I

1.0 0

o.oo 0

o.oo 0

.oo 0

o.oo j*j TO 3.2 0

o.oo 0

o.go 0

g.oo 8

-8:88 8 i:88 8 i:88 E TO j.4 0

o.oo 0

o. 0 0

.oo

  • '- TO

.6 0

0.80 0

8:88 0

8:88 8

8:88 8

88 8
88

.6 TO

.8 0

o. 0 0

0 J.8 TO '"*~

0 o.oo 0

o.oo 0

g.oo 0

8:88 0

o.,o 8

l!P

    • 3 TO '"*

0 o.oo 0

o.oo 0

.oo 0

0 I.

0 T§

~=~

8 g.oo 0

o.oo 8

~:88 8

8:g8

8 I 5*i T

.oo 0

o.og

s. T 6.o 0

o.oo 0

o.o 0

.oo 0

o. 0
i 6*~ TO,.s 0

o.og 0

8:88 8

8:88 8 1:88 8

TO

.o 0

o.o 0

o:fog

  • ~ TO 7.S 0

o.oo 0

o.oo 0

o.oo 0

.oo

88
1. rg e.o 0

g.oo 0

8: 08 0

8:88 0

8:18 8

I: g t*g T 9.8 0

  • go 8

8 0

g

  • 0 o.go 8:88 0

8: 8 0

8.oo 0

l.oo 10: l8 lY:o

o. 0 0
o. 0 0

0 0

.oo 0

.oo 11

  • 0 lV H:8 8

8:88 0

8:88 8

8:88 0

8:88 g

8:88 g

8:13 0

0 TOTAi.

222 100.00 69 100.00 27 100.00 5

100.00 0

o.oo 0

o.oo MAXIMUM AMf.

I.HI

.32

.52

.12 o.oo o.oo TOTAi. fttttCJ~ITATION f'OA OATA P£RIOO 14.66 lffCHES 2~f PCT.

~;

PCT 08~AYATIOWS *uH NO Pll£CIPITATIOt,I

~.54 lauo oefHAnrlrs 99.9}

?Si ~YATI~ W H ~~PITATION GE o.ol INCH 21,~

... 6 tf~18e v:lt I

" 100:80

~ VAL 0 OB AVAT S

1,0.00 Rev. 35, 07/84

TABIZ 2.l-40 FREQUENCY DISTRIBUTION OF PRECIPITATION DATA PERIOD:

APRXL 1973-1976 PM;CIPITATION FAEOUENCY FAEOUEHCY f'AEOUENCY f'REffiNCY FR!:OUENCY F'REfflNCY CLASS Ol~TA18VTION Of' OISTRJB¥TION OF Ol~TR 1eynON Of" OISTA eynON Of' Ul!?itvx,~"°'

01ST If¥TJOH Of' INTERVAL PA CIPI ATJON PR~ClPl ATION PA CI Pl ATION PAECIPI ATION PAECIP A ION (INCHE:SI J HOYA 2 HOYA l +:JiR o~ffiAON 12 "ffl z- ~

OVA.AT ON OURAT ON OURAT ON OURAT ON DURA ON NOe PCT.

~7 PCT.

NO.

PCT.

NO.

PCT.

NOO PCT.

"°o PCTe

.o TO

  • l 198 88.39 46.25 0

o.oo 0

o.oo o.oo o.oo

  • } TO

.z 16 7.14 31 38.7S 2..

U:U 1 l~:H 0

8.oo 8

8:j8

. rg

.)

6 2.68 4

s.oo 4

8

.oo

.J T

.4 3

1.34 3

1.75

~

8:i?t 8:88 8 I.

8 o4 TO

.s 0

o.oo 2

.so z

ztoo

.s TO

.6 0

o.oo z

2.so 3

e.~J 0

o.oo 1

100.00 0

~n

  • ~ TO

.7 0

o.oo 0

o.io 2

s. 6 0

~.oo 0

8:88 0

  • rg

.a l

.45 l

l. 5 0

8:88 i

2.oo 0

g

.8 T

.9 0

o.oo 0

o.oo 0

o.oo 0

.9 TO 1.0 0

o.oo 0

o.oo 0

o.oo 0

8.oo 0

o.oo 0

o.oo l:Y iO 1.1 0

o.oo 0

o.oo 0

o.go 0

.oo 0

o.oo 0

8:88

-2 18 l :~

0 0 00 0

o.oo 0

o. 0 0

.oo 0

o.oo 0

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 1 3 TO 1 *'-

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 1.4 TO l.s 0

o.oo 0

o.oo 0

8.oo 0

8.oo 0

o.oo 0

0.80

.s T

t g

8.oo 0

o.oo 8

-go 0

88 8

8:88 8

8: 8

-.6 18

.oo 0

o.oo

  • 0 0
      • 1,1 TO 1.8 0

o.oo 0

o.oo 0

o.oo 0

o.oo g

o.oo 0

o.go

  • -- loB Tl 1.9 0

o.oo 0

o.oo 0

o.oo 0

o.oo o.oo 0

o. 0 t

.9~y l:L 0

o.go 0

8:88 0

8:88 0

8:88 8

8:go 8 1:88 -

. :r~o 0

o. 0 0

0 0

o. g 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

0

.oo

~

1.4 TO

a 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo

.oo 06 TO 0

o.oo 0

o.oo 0

8:88 0

8:88 0

o.og 8:88

.8 TO

.o 0

o.oo 0

o.oo 0

0 0

8.o i

i:j +o i

.2 0

o.io 0

o.oo 8

g.oo 0

l~H I

.oo 0 l:°8 8

o. 0 0

8:88 8:H 8

!:H 0

.4 Tg

.6

o. 0 0

0 g

.So

.6 T

.8 0

o. 0 0

o.oo o*

J.e Tg... ~

0 o.oo 0

o.oo 8

8:88 8

8:88 8

8:§8 8

l:H 4o~ T It.

0 o.oo 0

o.oo

4.

TO s.o 0

o.oo 0

o.oo 0

o.go 0

o.oo 0

o. 0 0

5-~ TO s.s 0

o.oo 0

o.oo 0

o. 0 0

o.oo 0

o.oo 0

o.oo S.

TO 6.~

0 o.oo 0

8:88 0

0.08 0

!:H I

8:8° 0

8:08 6:~ ~8 t:o 0

o.oo 0

8 8.o 0

o.18 8

8:8°

~.OTO 0

o.oo 0

o.oo

.o 0

7,S 0

8.oo 0

o.go 0

o.oo 0

0.80 0

8. 0 0 1

.08 7.5 T8 e.g 0

.oo 0

o. 0 g

8:88 0

o. 0 0
8 0
9.

0

.oo 0

o.oo 0

o. 0 0

0

Sf

.OT 11*0 0

o.oo 0

o.oo 0

8.oo 0

8.oo 0

o.oo 0

10.0 TO

.o 0

o.oo 0

o.oo 0

.oo 0

.oo 0

o.oo 0

.o u.o i? l :&

0 g.oo 0

8:88 g

8:88 8

8:88 g

8:88 8

8:U 0

.oo 0

TOTAL 224 100.00 80 100.00 36 100.00 8

100.00 l

100.00 0

o.oo MAU MUM ANT*

.71

.79

.64

  • 72 o5l
    • oo TOTA~ ~ClPITATIOH ~OR OATA Pf~IOO 14o9Z INCHES HO' PCT
n PCT 085£AVAu; WITH mPAECjlPIJATIOH 260 9f 04 VA~IO oeg;ATI.

98.1&

~~YO 0soiu::v:T SI.: TAT ON GE OeOl INCH ziit

.9A

  • ~¥~18e :n aoA:08 100.0 Rev. 35, 07/84

TABLE 2.3-41 FR!QUENCY DISTRIBUTION OP PRECIPITATION DATE PERIOD:

MAY 1973-1976

~ECIPITATION Cl.ASS INTERVAL '

CINCHES>

1

.o TO

.1

.1 TO

.z

.z TO o3

  • .J TO

.4

.4 TO

.5

.5 TO

.6

.6 TO

.7

.1 Tg

.e

.8 T

.9

.9 TO 1.*1

'*I TO l* TO J.

TO le 1

.3 TO

}.4

.4 Tg l o5 eS T 1.6

.6 TO l.7 l

.7 TO J*8

I rn 2:i oO TO 2e2 e2 TO 2.4 2o4 TO 2.6 2e6 TO 2.8 2.8 TO 3.o 1.0 TO 3.2

.z TO 3.4

.4 TO 3.6 306 TO J.8 3.8 TO 4.0

... o Tg 4.5 T 5.0 SoO TO 5.5 5.5 TO 6.0 t:~ ~g t*'>

7.0 TO 1:~

1.s TO e.o e.g TO 9.o 9e TO lOoO 10*0 TO 11.0 11

  • 0 JV l~:8 TOTAL f'REOUENCY O1STR1BUTION OF' PRECIPITATION l HOUR OUR.AT ION NO 18, 29 3

4 2

1 0 8 0 l 0

0 0 g 0

0 g 0 0 0 g 0

0 0

0 8 0

0 0

0 0 8 0

0 0 8 PCTo 81.98 13.06 1.JS l.80

.90

.45 o.oo o.oo o.oo o.oo

.45 o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo 8:88 o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.og o.o o.oo 8:88 222 100.00 F'REOUENCY 01STR18UT10N Of' PRECIPITATION

~R:vr()N

"'g, s:~h 24 32.43 fl 4.05

2. 70 1.JS 5

6.76 0

o.oo 1

1.35 0

o.oo i

Y:~~

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo o

0.80 0

o. 0 0
o. 0 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo o

o.og s

8:88 g

8:88 00 o.oo o.oo o

o.o~

8 8:80 0

o.oo 0

o.oo 0

o.oo 00 o.oo o.oo 8

8:88 74 100.00 FREQUENCY

~l~ltirvnro.. 0,-

~~0N N06

~~h 19 55.88 10 29.41 0

o.oo l

2.94 0

o.oo l

2.94 l

2.94 1

2.94 0

o.oo 0

o.oo l

2.94 0

o.oo 0

o.oo 08 8:88 o.oo 0

o.oo 8

8:88 0

o.oo 0

o.oo 8

8:88 0

o.oo 0

o.oo 0

o.oo 8

8:88 0

0 0

0 0

0 8 0

0 0

0 8 8.oo

.oo o.oo o.oo 0:28 8.oo 8:88 o.oo o.oo o.oo 8:8&

34 100.00 MAXIMUM AMT.

1.06 TOTAi. PRECIPITATION f'OR DATA PERIOO 1.10 1.,.

16. 75 INCHES 08S[AYATIONS WITH HO PRE:CIPITATIO't 08SE:RVATIONS -,lTH PQ[CIPITATIOH GE. O.Ol INCH TOT"'- VAl..1O 08SCRYAT10NS Rev. 35, 07/84 PCT.

92.S-100.00 F'REOUlNCY 01 TR T ON Of" PRlc1 fVAJ10N 6 HOUR DURATION N03 r

0 1 0 r A 8 0 g 0 8 0

0 0 8 0 g 8 8 0

0 0

0 0 8 0 j PCT.1.

o.ou d:H o.oo 20.00 o.oo 28:88 20.og o.o o.oo

. o.oo o.oo 8:88 o.og 8:io 0*08 8:oo o.oo o.oo o.oo o.oo 8:88 8:88 0:81 8.o o.o o.oo o.oo o.oo 8:og 0.80 8:83 5

100.00 f'REmNCY 01ST 8¥T!ON Of' PA£Cl I AT10N 12 HOUR OUAAT!ON

"°&

~:Xa 00 o.oo o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 8

8:88 0

o.oo 0

o.oo 00 o.oo o.oo 0

o.oo 8

8:88 0

o.oo o0 g.oo o

g:og 8

0:80 Oo o.go

o. 0 0

o.oo o

g.oo 0

.oo 8

8:88 0

o.oo 0

o.oo 8

8:88 Oo 8*00

.oo 0

o.oo 8

o.oo o.oo 0

o.oo 88 8:88 8:88 0

o.oo o.oo YALIO 09DAYATI~

lNYAL.10

~RYATl TOTAi. 09 AVATI f'REfflNCY BUl tPY¥Il?NON Of" t~~ON NOt PCT 1 V

0.0u 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo o

g.oo 0

.oo 00 o.oo o.oo 8

0.80

o. 0 0
o. 0 0

o.oo g

8:88 0

0:88 8

8.08 o

8.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 2

o.oo o

8:88 8

8:38 80 8:88 o.oo 0

o.oo o

o.go I 8:d o

~.oo 0

o.oo 8

8:88 0

o.oo o.oo PCT lOf.00 100:!8 CII NI "'

TABLE 2.3-42 FREQUENCY DISTRIBUTION OF PRECEIPITATION DATA PERIOD: JUNE 1973-1976 PRECIPIT AT10N FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY CLASS INTERVAL OISTRIBITION OF DISTRIBITION OF DISTRIBITION OF OISTRIBITION OF DISTRIBITION OF DISTRIBITION OF (INCHES)

PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION 1 HOUR DURATION 2 HOUR DURA TJON 3 HOUR DURATION 6 HOUR DURATION 12 HOUR DURATION 24 HOUR DURATION

.0 TO

.1 180 78.60 44 58.67 0

0.00 0

0.00 0

0.00 0

0.00

.1 TO

.2 33 14.41 16 21.33 22 68.75 0

0.00 0

0.00 0

0.00

.2 TO

.3 5

2.18 5

6.67 5

15.63 4

57.14 0

0.00 0

0.00 3

TO

.4 4

1.75 4

5.33 1

3.13 1

14.29 0

0.00 0

0.0D

.4 TO

.5 2

.87 2

2.67 1

3.13 0

0.00 0

0.00 0

0.00

.5 TO

.6 3

1.31 2

2.67 0

0.00 2

28.57 0

0.00 0

0.00

.6 TO

.7 2

.87 1

1.33 2

6.25 0

0.00 0

0.00 0

0.00

.7 TO

.8 0

0.00 1

1.33 1

2.94 0

D.00 0

0.00 0

0.00

.8 TO

.9 0

o.oo 0

0.00 1

2.94 1

20.00 0

0.00 0

0.00

.9 TO 1.0 0

0.00 0

0.00 0

0.00 1

20.00 0

0.0D 0

0.00 1.0 TO 1.1 1

.45 1

1.35 0

0.00 0

0.00 0

0.00 0

o.oo 1.1 TO 1.2 0

0.00 0

0.00 1

2.94 0

0.00 0

0.00 0

0.00 1.2 TO 1.3 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00

. 0 0.00 1.3 TO 1.4 0

000 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.4 TO 1.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.5 TO 1.6 0

0.00 0

000 0

0.00 0

0.00 0

0.00 0

0.00 1.6 TO 1.7 0

0.00 0

0.00 0

0.00 0

000 0

0.00 0

0.00 1.7 TO 1.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.8 TO 1.9 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 1.9 TO 2.0 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

o.oo 2.0 TO 2.2 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 0

0.00 2.2 TO 2.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.4 TO 2.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.6 TO 2.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.8 TO 3.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.0 TO 32 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.2 TO 3.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.4 TO 3.6 0

0.00 0

0.00

.0 0.00 0

0.00 0

0.00 0

0.00 3.6 TO 3.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.8 TO 4.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.0 ro 4.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 4.5 TO 5.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 5.0 TO 5.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.5 TO 6.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.0 TO 6.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.5 TO 7.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

o.oo 7.0 TO 7.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.0 7.5 TO 8.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 8.0 TO 9.0 0

0.00 0

0.00 0

0.00 0

000 0

0.00 0

0.00 9.0 TO 10.0 0

000 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 10.0 TO 11.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00

  • 0 0.00 11.0 TO 12.0 0

0.00 0

o.oo 0

0.00 0

000 0

0.00 0

o.oo GT 12.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 TOTAL 229 100.00 75 100.00 32 100.00 7

100.00 0.00 0

0.00 MAXIMUM AMT.

.67

. 71

.99

.60

.48 0.00 TOTAL PRECIPITATION FOR DATA PERIOD 19.29 INCHES NO.

PCT.

NO.

PCT.

OBSERVATIONS WITH NO PRECIPITATION 2651 92.05 VALID OBSERVATIONS 2880 100.00 OBSERVATIONS WtTH PRECIPITATION GE 0.01NUI 229 7.95 INVALID OS SERVA TIONS 0

0.00 TOTAL VALID OBSERVATIONS 2880 100.00 TOTAL OBSERVATIONS 2880 100.00 Rev. 35. 07/84

TABLE 2.3-43 FREQUENCY DISTRIBUTION OF PRECEIPITATION OAT A PERIOD: JULY 1973-1976 PRECIPITATION FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY CLASS INTERVAL DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF OISTRIBITION OF DISTRIBITION OF OISTRIBITION OF (INCHES)

PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION 1 HOUR DURATION 2 HOUR DURATION 3 HOUR DURATION 6 HOUR DURATION 12 HOUR DURATION 24 HOUR DURATION

.o TO

.1 128 7?..73 14 33.33 0

0.00 0

0.00 0

0.00 0

0.00

.1 TO

.2 34 19.32 15 35.71 8

40.00 0

0.00 0

0.00 0

0.00

.2 TO

.3 3

1.70 3

7.14 4

20.00 1

33.33 0

0.00 0

0.00 3

TO

.4 3

1.70 6

14.29 4

20.00 1

14.29 0

0.00 0

0.00

.4 TO

.5 1

,57 0

0.00 1

5.00 0

0.00 0

0.00 0

0.00

.5 TO

.6 2

1.14 0

0.00 0

0.00 1

33.33 0

0.00 0

0.00

.6 TO

.7 1

.57 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00

.7 TO

.8 1

.57 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00

.8 TO

.9 1

.57 1

2.38 0

0.00 0

0.00 0

0.00 0

0.00

.9 TO 10 0

0.00 1

2.38 0

0.00 0

0.00 0

0.00 0

0.00 1.0 TO 1.1 1

.57 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.1 TO 1.2 0

0.00 1

2.38 2

10.00 0

0.00 0

0.00 0

0.00 1.2 TO 1.3 0

0.00 1

2.38 0

0.00 0

0.00 0

000 0

0.00 1.3 TO 1,4 0

0.00 0

0.00 1.

5.00 0

0.00 0

0.00 0

0.00 1.4 TO 1.5 0

0.00 0

0.00 0

0.00 1

33.33 0

0.00 0

0.00 1.5 TO 1.6 0

0.00 0

0.00 0

0.00 0

0.00 0

000 0

0.00 1.6 TO 1.7 1

.57 0

o.oo 0

0.00 0

0.00 0

0.00 0

0.00 1.7 TO 1.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.8 TO 1.9 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.9 TO 2.0 0

0.00 0

000 0

0.00 0

o.oo 0

0.00 0

0.00 2.0 TO 22 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.2 TO 2.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.4 TO 2.6 0

0.00 0

000 0

0.00 0

0.00 0

0.00 0

0.00 2.6 TO 2.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.8 TO 3.0 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 3.0 TO 3.2 0

0.00 0

0.00 0

0.00 0

o.oo 0

0.00 0

0.00 3.2 TO 3.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.4 TO 3.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 36 TO 3.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.8 TO 40 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.0 TO 4.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.5 TO 5.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.0 TO 5.5 0

o.oo 0

0.00 0

0.00 0

0.00 0

0.00 0

000 5.5 TO 6.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.0 TO 6.5 0

0.00 0

0.00 0

0.00 0

0.00 0

000 0

0.00 6.5 TO 7.0 0

0.00 0

0.00 0

0.00 0

0.00 0

000 0

0.00 7.0 TO 7.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.0 7.5 TO 8.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

000 8.0 TO 9.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 9.0 TO 10.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

000 10.0 TO 11.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 11.0 TO 12.0 0

0.00 0

0.00 0

0,00 0

0.00 0

0.00 0

0.00 GT 12.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 TOTAL 176 100.00 42 100.00 20 100.00 3

100.00 0

0.00 0

0 00 MAXIMUM AMT.

1 61 1.22 1.38 1.46 0 00 0.00 TOTAL PRECIPITATION FOR DATA PERIOD 18.90 INCHES NO.

PCT.

NO PCT.

OBSERVATIONS WITH NO PRECIPITATION 2799 94.08 VALID OBSERVATIONS 297'..i 99.97 OBSERVATIONS WITH PRECIPITATION GE 0.01NCH 176 5.92 INVALID OBSERVATIONS 1

.03 TOTAL VALID OBSERVATIONS 2975 100.00 TOTAL OBSERVATIONS 2976 100.00 Rev. 35, 07/84

TABLE 2.3-44 PRZOOERCY D:tSTIUBOTION OP PRECIPITATION M'l'A PERIOD:

AUGUST 1973-1976 PRECIPITATION F'RE:Q~NCY fREO~ENC'r F'REOKiNCY F'REO~NCY F'Ai0¥11'K:Y f"RimNCY iLAfS Bill 1yyuro OF'

~lST 1eynON OF' 01ST f¥TIYN Of

~,~I,vnro,.cw 8.\ h YVIJ~W uh,vn~ON°'"

NT RYAl R CIP AT 0,..

RECIPI Alla..

PREClP AT ON CINCHES) 1 "°'ro Z HOUR l HOro

~Rffi"ON 12 "°YR Z4 HOro OUAAT ON OURATION DURAT ON OURAT ON OURAT ON

.o TO NO.

PCT.

NO.

PCT.

HO.

PCTO NOO PCTO NOO PCTI HOO PCl:il

.1 152 83.06 Z9 se.oo 0

o.o o.o o.o

  • i TO
i 19 10.1a 7

14.go li? io.oo 0

o.og 0

g:88 i

TO

~

1. 8

e. o

't 6.67 2

so.o 0

  • 3 TO o't

.64 5

10.0*

't 6.6 7 0

o.oo 0

.oo

.go

.4 TO

.s 1

.ss 1

.2.00 u

o.oo 0

o.oo 0

o.oo

  • 0

.5 TO

.6 u

o.oo 2

4.00 0

o.oo l

~,~n 0

i~H 0

o.oo

1 TO

.1 1

.ss 0

o.oo f

i:J~

l 8

0 g.ot

  • rg

.e 0

a.go 8

8:88 8

g

88

.e T

.9 0

o. 0 e9 TO 1-*

o.**

l 2.00 A

4.l~

0 o.oo 0

o.oo 8

i~H l*i TO l:~

l

.ss 0

l.oo o.oo 0

o.oo 8

o.oo l* TO 8:88 1

  • go 0

f:Y9 8

8:i8 8:88 g

TO

.J 0

0

o. 0 1

1.J TO 1 **

8 o.go 0

o.oo 0

&:88 0

8:88 8

o.go g

8:88 1.4 TO l.s

o. 0 0

o.oo 0

0

g. 0

}*5 TO

.6 0

o.oo 0

8:88 0

8:88 8

o.go

.go g

8:83

.6 TO

.1 0

o.oo 0

0

o. 0
o. 0 1

.7 T§ 1.8 0

o.oo 8

o.oo 0

o.oo 8 l:H i i:H 0

1~18

.8 T l.9 8

o:8g 8:88 8 !:go 8

.9 T

i oO TO 0

8.o 0

o.oo

.08 0

o.. oo o.oo 0

o. I...

1

  • 2 TO 1.4 g

o.oo 0

o.oo 0

0.80 0

o.oo 0

o.oo 0

t,I

  • .,. T8

.6 8:88 0

8:8g 8 I. 8 0

8:88 8

o.oo 0

06 T

.8 0

0 o.uo 0

8: 0 I

  • 8 TO J.o 0

o.oo 0

o.o 0

oo 0

o.oo 0

o.oo 0

I:J f§ I.z 0 i:88 0

o.oo 0

o.go 8

i~H 8

o.oo 8

o.oo 0

0 o.oo 0

o.go f.oo

    • T
t 0

.oo 0

o.go 0

8:08 0

0

o. 0 0

.oo 06 T 0

.oo 0

o. 0 0

o.oo 0

0 o.oo 0

.oo J.8 TO --~

0 g.oo 0

o.oo 0

o.oo 0

!.oo 0

8:88 8

f:H 4*~ TO **

0

..og 0

o.oo 0

o.oo 0

88 8

TO s.o 0

o.o 0

o.oo 0

o.oo 0

0

.o rg s.s 0

o.oo 0

o.oo 0

o.oo 0

i:H 0

g.oo 0 l

8f oS T 6.~

g 8.oo*

0 o.og 0

8:U 8

0

.oo 0

6.~ T8 t*

.oo 0

o.o 0

0 0.10 0

88 T
  • 3 0

8:88 0

g.oo 0

8:88 8

8:18 8

8: 8 8

  • i TO
7.

0 0

.oo 0

7.

T8 ~*8 0

8:88 8

8:88 8

8:88 0

8: !

8 2:83 I

88 floO T 0

0 9.0 T 10.0 0

o.oo 0

o.oo 0

0-1*

0

o.

0 o.oo

.oo lf :8 ~g l}:g0 0

o:g8 0

0.80 g

o. 0 i

8:88 8

g:88

H 0
8. 0 0
o. 8
g. 0 8

GT l

  • 0 0
o.

.oo

.oo TOUl 193 101>.oo 50 100.00 24 100.00 4

100.00 0

o.oo o.oo MAJl lNUM AMT*

1.06 1.14 I.JO

.61 o.oo o.oo TOTAL PM:CIPlfATION FOR DATA PE:AIOO l4.J1 INCHES l~.l PCT PCT ffffRVATf~ WfTH :1tmfIPIJATtgr 9l:8t lAUO ce*TI~

110.01

~VAT W TH

~

TAT OH OeOl INCH

-~fl NJM.I A I a.,1 o.g M. VAL O 08SE'l°'AJ too.Ao 0 M.

VA IQN lff Rev. 35, 07/84

TABLE 2.3-45 FREQUENCY DISTRl8UTION OF PRECEIPITATION DATA PERIOD: SEPTEMBER 1973-1976 PRE.ClPITATION FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY CLASS INTERVAL DISTRIBITION OF OISTRIBITION OF DISTRIBITION OF DISTRIBITION OF OISTRIBITION OF DISTRIBITION OF (INCHES)

PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION 1 HOUR DURATION 2 HOUR DURATION 3 HOUR DURATION 6 HOUR DURATION 12 HOUR DURATION 24 HOUR DURATION

.0 TO

.1 225 76.01 47 41.59 0

0.00 0

0.00 0

0.00 0

0.00

.1 TO

.2 37 12.50 31 27.43 27 49.09 0

0.00 0

0.00 0

0.00

.2 TO

.3 14 4.73 7

6.19 4

12.73 1

6.25 0

0.00 0

0.00 3

TO

.4 8

2.70 10 8.85 4

7.27 3

18.75 0

0.00 0

0.00

.4 TO

.5 6

2.03 5

4.42 0

1.82 1

6.25 0

0.00 0

0.00

.5 TO

.6 4

1.35 5

4.42 0

10.91 1

6.25 1

33.33 0

0.00

.6 TO

.7 0

0.00 2

1.77 0

3.64 2

12.50 0

0.00 o

0.00

.7 TO

.8 1

.34 3

2.65 2

7.27 1

6.25 0

0.00 o

0.00

.6 TO

.9 0

0.00 1

.88 0

5.45 1

6.25 0

0.00 0

0.00

.9 TO 1.0 0

o.oo 0

0.00 1

0.00 1

25.00 0

0.00 0

0.00 1.0 TO 1.1 0

.34 1

.88 0

0.00 4

6.25 0

0.00 0

0.00 1.1 TO 1.2 0

0.00 0

0.00 0

0.00 1

0.00 0

0.00 0

0.00 1.2 TO 1.3 a

0.00 0

0.00 1

1.82 0

0.00 0

0.00 0

0.00 1.3 TO 1.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.4 TO 1.5 0

0.00 0

0.00 0

0.00 0

0.00 a

0.00 0

o.oo 1.5 TO 1.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.6 TO 1.7 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.7 TO 1.8 0

0.00 0

0.00 a

0.00 0

0.00 0

0.00 0

0.00 1.8 TO 1.9 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.9 TO 2.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.0 TO 2.2 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.2 TO 2.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.4 TO 2.6 1

.34 1

.88 0

0.00 0

0.00 0

0.00 0

0.00 2.6 TO 2.8 0

o.oo 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.8 TO 3.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.0 TO 3.2 0

0.00 0

0.00 0

0.00 a

0.00 0

0.00 0

0.00 3.2 TO 3.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.4 TO 3.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.6 TO 3.8 a

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.8 TO 4.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.0 TO 4.5 a

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.5 TO 5.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.0 TO 5.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.5 TO 6.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.0 TO 6.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.5 TO 7.0 0

0.00 0

0.00 o

0.00 0

0.00 0

0.00 0

0.00 7.0 TO 7.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.0 7.5 TO 8.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 8.0 TO 9.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 9.0 TO 10.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 10.0 TO 11.0 0

0.00 0

0.00

  • 0 0.00 0

0.00 0

0.00 0

0.00 11.Q lO 12.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 GT 12.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 TOTAl 296 100.00 113 100.00 55 100.00 16 100.00 3

0.00 0

0.00 MAXIMUM AMT.

2.56 2.60 1.27 1.11 2.19 0.00 TOTAL PREC1PITATlON FOR DATA PERIOD 30.17 INCHES NO.

PCT.

NO.

PCT.

OBSERVAl IONS WITH NO PRECIPITATION 2578 89.70 VALID OBSERVATIONS 2874 99.79 O8SERVATIONS WITH PRECIPITATION GE 0.01NCH 296 10.30 INVALID OBSERVATIONS 6

.21 TOTAL VALID OBSERVATIONS 2874 100.00 TOTAL OBSERVATIONS 2800 100.00 Rev. 35. 07/84

TABLE 2.3-46 PREQOEMCY DISTRIBUTIOR OF PRECIPITATION O.ATA PFRIOO:

OCTOBER 1973-1976 PREC IP lT A TION f"R0UENCY f'~tOUE~CY FREUUE,..CY f"REQUENCY f'REO~NCY FREQ~NCY l

LASS OllTRl~vuoi-. OF'

~ IST~l8VTION Of OlSTRieynoN Of

~1lrR1evr,oN or BIST 8VTfOH Of'

~ lST 1yv1,ro OF NTERVAl* !

PR CIPl ATJON

~t.ClPI TATION t>HECIP l ATlON R ClPI A ION RECIPl A ION H~C(P A

ON

CINCHES, 1 HOUR 2 HOUR J HOUR 6 HOVA 12 HOVR 24 HOUR OU~AllOl'i OUNATION DURATlON OURAllON DURATION OURATION NO.

PCT.

NO.

PCT*

NO.

PCT.

NO.

PCT.

NO.

PCT.

HO.

?CT.

.o TO

  • 1 187 e2.02 37 47.44 0

o.oo 0

o.oo 0

o.oo 0

o.oo

=~

TO

.2 29 12.72 27 34.6l 21 16.76 0

o.yo 0

8:88 0

o.oo TO

.3 J

l.32 3

J.~5 0.81 1

11. 1 0

0 o.oo

.J TO

.4 4

l

  • 75 4

$.lJ 6

H,.22 f

2i.22 0

o.oo 0

o.oo

... TO

.s 2

.88 3

3.8':>

2 5.41 l.11 0

o.oo 0

o.oo

.s TO

.6 2

.ea 3

3.8S l

z.10 0

o.oo 0

o.oo 0

o.oo

.6 TO

.7 0

o.oo 0

o.oo l

z.10 l

11.11 0

o.oo 0

o.oo

.1 TO

.8 0

o.oo 8

o.oo 0

o.oo 0

2~:,~

0 o.oo 8

8:88

.a TO

.9 1

.44 o.oo 1

2.10 2

0 o.oo

.9 TO 1.0 0

o.oo 0

o.oo 0

o.oo l

11.11 0

o.oo 0

o.oo 1.0 TO 1

  • 1 0

o.oo 0

o.oo 0

o.oo 0

o.oo 1

50.00 0

o.oo 1

.1 TO 1.2 0

o.oo 0

o.oo 8

o.oo 8

8:88 8

8:88 8

8:88

.2 TO 1.3 0

o.oo 1

1.28 o.oo 1.3 TO l.4 0

o.oo u

o.oo 0

o.oo 0

o.oo 0

o.oo 0 i

.oo l

.4 TO 1.s 0

o.oo 0

o.oo l

z.10 0

o.oo 0

o.oo 0

.oo

.s TO 1.6 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.go 0

.oo

.b TO 1.1 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o. 0 0

.oo 1.7 TO 1.e 0

o.oo 0

o.oo 0

o.oo 0

1Y:Y~

0 o.oo 0

o.oo

'i:i TO l.9 0

o.oo 0

o.oo 0

g.oo 1

0 o.oo 0

o.oo TO

~.o 8

o.oo 0

o.oo 8

.oo 0

8:88 8

8:88 0

8:88 OI cO TO

.2 o.oo 0

o.oo

.oo 0

0 tn r:,o

.2 TO 2.4 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo (I) z.4 TO 2.6 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo

~.6 TO i.e 0

o.oo 0

8:88 0

8:88 0

0.00 l

sg.oo 0

8:88

.8 TO

.o 0

o.oo 0

0 0

o.oo 0

.oo 0

"1111 en 3.0 TO 3.2 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo t

3

.z TO 3.4 0

o.oo 0

8:88 0

o.oo 0

o.oo 8

8:88 8

o.oo

.4 rn j.6 0

o.oo 0

0 o.oo 0

o.oo 8:88

.6

.s 0

o.oo 0

.oo 0

o.oo 0

o.oo 0

.oo 0

J.8 TO 4.~

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

8.oo

'-*~ TO

4.

0 o.oo 0

o.oo 0

.o.go 0

o.oo 0

o.oo 0

.oo TO s.o 0

o.oo 0

o.oo 0

o. 0 0

8.oo 0

o.oo 0

o.oo

~.o TO 5.5 0

o.oo 0

o.oo 0

o.oo 0

.oo 0

o.oo 0

o.oo

.s TO 6.~

0 o.oo 0

o.oo 0

o.oo 0

o.oo 8

o.oo 0

1:88 6.~ TO

6.

8 o.oo 0

o.oo 0

o.oo 0

o.oo o.oo 0

TO 1.0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

.oo 9:o TO 7.5 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 7.5 TO e.o 0

o.oo 0

o.oo 0

o.oo 0

o.go 0

o.oo 0

o.oo R.g TO 9.0 0

o.oo 0

o.oo 0

o.oo 0

o. 0 0

8.oo 0

g.oo

9.

TO 10.0 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

.oo 0

.oo 10.0 TO ll.O 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.go 11.0 TO li.O 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o. 0 GT l.o 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo TOTAl l28 100.00 78 100.00 37 100.00 9

100.00 2

100.00 0

o.oo MAXI..._,... AMT.

.83 1.26 1.50 1.90 2.7..

o.oo TOTA~ PP£CIPITATIO~ ~OR OATA PERIOO 11.59 lNCl't(S HOe PCT.

PCT 08~RYATIONS VfTH NO PRt<clPlTATION 2741:S 9,.3..

l ALIO 08iaiATIONS 100.01 VS RVATlroS V TH PQi~p TATI~ G£ O.Ol INCH 2~~:

.6f>

NfAt..18e AlATl~ n,l 3.o AL V-L O 08SE~YAT S

100.00 0 Al A ION 10.o Rev. 35. 07/84

TABLE 2.J.47 FREQUENCY DISTRIBUTION OF PRECEIPITATION DATA PERIOD: NOVEMBER 1973-1976 PRECIPITATION FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY CLASS INTERVAL DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF (INCHES)

PRECIPITATION PRECIPITATION PRECIPITATION PRE Cf PlT ATION PRECIPITATION PRECIPITATION 1 HOUR DURATION 2 HOUR DURATION 3 HOUR DURATION 6 HOUR DURATION 12 HOUR DURATION 24 HOUR DURATION

.0 TO

.1 156 86.67 34 58.62 0

0.00 0

0.00 0

0.00 0

0.00

.1 TO

.2 19 10.56 15 25.86 18 75.00 0

0.00 0

0.00 0

0.00

.2 TO

.3 4

2.22 6

10.34 0

0.00 J

42.86 0

0.00 0

0.00 3

TO

.4 1

.56 3

5.17 5

20.83 1

14.29 0

0.00 0

0.00

.4 TO

,5 0

0.00 0

0.00 1

4.17 0

0.00 0

0.00 0

0.00

.5 TO

.6 0

0.00 0

0.00 0

0.00 1

14.29 0

50,0 0

0.00

.6 TO

,7 0

0.00 0

0.00 0

0.00 1

14.29 0

0.00 0

0.00

.7 TO

.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00

.8 TO

.9 0

0.00 0

0.00 0

0.00 1

14.29 0

0.00 0

0.00

.9 TO 1.0 0

0.00 0

0.00 0

0.00 0

0,00 0

0.00 0

0.00 1.0 TO 1.1 0

0.00 0

0.00 0

0.00 0

0.00 1

50.00 0

0.00 1.1 TO 1.2 0

0,00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.2 TO 1.3 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.3 TO 1.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1,4 TO 1.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.5 TO 1.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0,00 1.6 TO 1.7 0

0.00 0

0.00 0

0,00 0

0.00 0

0.00 0

0.00 1.7 TO 1.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.8 TO 1.9 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.9 TO 2.0 0

0.00 0

000 0

0.00 0

0.00 0

0.00 0

0,00 2.0 TO 2.2 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0,00 2.2 TO 2.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.4 TO 2.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.6 TO 2.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.8 TO 3.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0,00 3.0 TO 3.2 0

0.00 o

  • 0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.2 TO 3.4 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.4 TO 3,6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

000 3.6 TO 3.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3.8 TO 4.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.0 TO 4.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.5 TO 5.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.0 TO 5.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.5 TO 6.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.0 TO 6.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 D

0.00 6.5 TO 7.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 7.0 TO 7,5 0

0,00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 7.5 TO 8,0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 8,0 TO 90 0

0.00 0

0.00 0

000 0

0.00 0

0 00 0

0.00 9.0 TO 10.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 10.0 TO 11.0 0

0,00 0

0.00 0

0.00 0

0,00 0

0.00 0

0.00 11.0 TO 12.0 0

0.00 0

0.00 0

000 0

0.00 0

0 00 0

0.00 GT 12.0 0

000 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 TOTAL 180 100.00 58 10000 24 100.00 7

100.00 2

0.00 0

0.00 MAXIMUM AMT.

.35

.40

.48 84 0.00 0.00 TOTAL PRECIPITATION FOR DATA PERIOD 11.03 INCHES NO.

PCT.

NO.

PCT.

OBSERVATIONS WITH NO PRECIPITATION 2700 93.75 VALID OBSERVATIONS 2880 100.00 OBSERVATIONS WITH PRECIPITATION GE 0.01NCH 180 6.25 INVALID OBSERVATIONS 0

0.00 TOTAL VALID OBSERVATIONS 2880 100.00 TOTAL OOSERVATIONS 2880 100.00 Rev. 35, 07/84

TABLE 2.3-48 FREQUENCY DIS'l'RIBUTION OP P~IPITATION DATA PERIOD:

DECEMBER 1973-1976 PRECIPITATION fREOUENCY f'REOuENCY FREQUENCY f"REOUf:NCY F'REOUENCY fREO~ENCY i~~~iYAL 01lr,uyuuON o, OlSHHayuoN Of' OlSHHfVTION OF OISTRlfVTJro OF' OISTRl8VTION OF 01ST 1yvTJYN OF PR CIP TATlON PRt:ClPl ATION PRECIP ATION PRECIP A

ON PRECIPI ATION PAEClP A ON CINCHES>

1 MOVR 2 HOUR J HOUR 6 HOYR 12 HOUR 24 HOUR OURAT ON DURATION DURATION OURAT ON DURATION OVRATION

~~j PCT.

NO.

PCT.

NOe PCT.

NO.

PCT.

NO

NO.

PCT

. o TO

.1 68.83 3

12.50 0

o.oo 0

o.oo 0

o.oo 0

o.oo

=~

TO

.2 15 19.48 12 50.00 5

?8.oo 0

o.oo 0

o.go 0

o.oo TO

.J 3

3.c;,o 6

2i:?1 l

.oo 0

o.oo 0

o. 0 0

o.oo

.J TO

.4 l

1.30 l

3 30 00 0

o.oo 8

o.og 8

o.oo

.4 TO

.5 2

2.60 0

o.oo 0

o.oo 0

o.oo o.o o.oo

.5 TO

.6 0

o.oo 0

o.o~

(I o.oo 3

100.00 0

o.oo 0

o.oo 6 TO

.1 l

l. Jo l

4.1 0

o.oo 0

o.oo 0

o.og 0

o.oo

.7 TO

i 2

~.60 1

'"* 17 0

8:88 8

8:88 8

8:80 0

8:88 8 TO 0

.oo 0

o.oo 0

0 9 TO 1.y 0

o.oo 0

o.go 0

8.oo 0

o.oo 0

o.oo 0

o.og l*f TO l:i 0

o.oo 0

o. 0 0

.oo 0

o.oo 0

o.oo 0

o.o l

TO 0

o.oo 0

o.oo l

10.00 0

o.oo 1

100.00 8

o.go 1.2 TO l

  • 0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo

o. 0 l.J TO l.4 0

o.oo 0

o.oo 0

o.og 0

o.io 0

o.oo 8

8.oo

.4 T8

.s 0

o.oo 0

o.oo 0

o.o 0

o. 0 0

o.oo

.oo

.5 T 1.6 8

8:88 0

8:88 8

8:88 8

8. 0 8

8:88 8

8:88 J.6 T

.1 0

  • 0 1.7 TO l.8 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo

.e TO 1.9 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

8.oo

.9 TO ~:j 0

o.oo 0

o.oo 0

8:88 0

8:88 8

8:88 8

88 0,

z.o TO 0

o.oo 0

o.oo 0

0 l>I z.z rg 2.4 0

o.oo 0

8.oo 0

o.oo 0

o.oo 0

o.go 0

o.oo z.4 T 1.6 0

o.oo 0

.oo 0

o.oo 0

o.oo 0

o. 0 0

o.oo I

i.6 TO

.8 0

o.oo 0

o.oo 0

o.oo 0

8.oo 8

o.go 0

o.oo

. e TO

.o 0

o.oo 0

o.oo 0

o.oo 0

.oo

o. 0 0

8:88 E

3.j TO J.2 I

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.go 0

3:4 18

~*'"

o.oo 0

o.oo 0

8:88 8 8:08 8

o. 0 g l:H

.6 8.oo 0

0.30 0

8:88

.6 TO

.8

.oo 0

o. 0 0

.3o 0

3.8 TO 4.0 0

o.oo 0

o.oo 0

o.oo 8

g.oo 0

8.oo 8

8:88 4.0 TO 4.5 0

8:88 0

8:88 0

8:88

.go 8

.go 4 5 TO s.o 0

0 0

0

  • 0
o. 0 0

5.~ TO 5.5 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 5

TO 6.~

0 o.oo 0

o.oo 0

o.oo 0

0.08 I

0.80 0

i~i8 6.~ T8,:~

8 8:88 0

o.go 0

8:8g g

o.o

o. 8 0
6.

T 0

o. 0 0

o.o

o.

8 7.0 TO

7.

0 o.oo 0

o.oo 0

o.o 0

o.oo o.oo 8:88 7.5 TO 8.0 0

o.oo 0

o.oo 0

o.oo 8

8:88 0

8:88 8

e.o TO 9 0 0

o.oo 0

o.oo 0

o.oo 0

9.0 TO 10.0 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

i~H 10.0 TO 1~.o 0

o.oo 0

o.oo 0

o.oo 0

0.08 g

g.oo ll O TO J *8 8

o.og 0

8.oo 8

o.go 8

8.o

.go Gl 12.

o.o 0

.oo

o. 0

.o

  • 0 TOTAi.

11 100.00 24 100.00 10 100.00 l

100.00 1

lGO.OO o.oo MAXIMUM AMT.

.75

.79 1.18

.60 1.12 o.oo TOTAl. PRECIPITATIO.. FOR DATA PERIOO 8.82 INCHES NO.

PCT im PCh

?§SfAYATI~ WITH~ PRE:ilPITATIOflf lflfCH 164~

9'>.51 lAUO C!~ATl'r/~

~,.

l RVAT SW T" P~~P TATI~ GE 0 01 11

~¥:t' 0 v:nol. s

..,.i*

0 A~ VAL O 08SERYAT S

172.:!

100.ou 10

  • 0 Do,r

".\ i;.

0"7/R4

~ *---

TABLE 2.3-49 FREQUENCY OISTRIBUTION OF PRECEIPITATION OATA PERIOD: JANUARY 1973 - DECEMBER 1976 PRECIPITATION FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY FREQUENCY CLASS INTERVAL DISTRIBITION OF DISTRIBITION OF OISTRIBITION OF DISTRIBITION OF DISTRIBITION OF DISTRIBITION OF (INCHES)

PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION PRECIPITATION 1 HOUR DURATION 2 HOUR DURATION 3 HOUR DURATION 6 HOUR DURATION 12 HOUR DURATION 24 HOUR OURA TION

.o TO

.1 1993 82.15 385 48.25 0

0.00 0

0.00 0

0.00 0

0.00

.1 TO

.2 298 12.28 255 31.95 220 60.11 0

o.oo 0

0.00 0

0.00

.2 TO

.3 53 2.18 53 6.64 54 14.75 19 22.89 0

0.00 0

0.00 3

TO

.4 33 1.36 47 5.89 38 10.38 18 21.69 0

0.00 0

0.00

.4 TO

.5 17

.70 14 1.75 11 3.01 6

7.23 1

7,69 0

0.00

.s TO

.6 12

.49 20 2.51 13 3.55 13 15.66 3

23.08 0

0.00

.6 TO

.7 6

.25 4

.50 8

2.19 7

8.43 o

0.00 0

0.00

.7 TO

.B 5

.21 7

.BB 7

1.91 5

6.02 1

7.69 o

0.00

.8 TO

.9 2

.OB 2

.25 5

1.37 5

6.02 0

0.00 0

0.00

.9 TO 1.0 1

.04 2

.25 2

55 3

3.61 0

0.00 0

0.00 1.0 TO u

3

.12 3

.38 0

0.00 4

4.82 0

0.00 0

0.00 1.1 TO 1.2 1

.04 2

.25 4

1.09 1

1.20 4

30.77 0

0.00 1.2 TO 1.3 0

0.00

3.

.38 2

.55 0

0.00 0

0.00 0

0.00 1.3 TO 1.4 0

0.00 0

0.00 1

.27 0

0.00 0

0.00 0

o.oo 1.4 TO 1.5 0

0.00 0

0.00 1

.27 1

1.20 0

0.00 0

0.00 1.5 TO 1.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 1.6 TO 1.7 1

.04 0

0.00 0

0.00 0

0.00 1

7.69 o

0.00 1.7 TO 1.8 0

0.00 0

0.00 0

0.00 0

0.00 0

0,00 0

0.00 1.8 TO 1.9 0

0,00 0

0.00 0

0.00 1

1.20 0

0.00 0

o.oo 1.9 TO 2.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 2.0 TO 2.2 0

0.00 0

0.00 0

0.00 0

0.00 1

7.69 0

0.00 n

TO 2.4 0

0.00 0

0.00 0

000 0

0.00 0

0,00 0

0.00 2.4 TO 2.6 1

.04 1

.13 0

0.00 0

0.00 0

0.00 0

0.00 2.6 TO 2.8 0

0.00 0

0.00 0

0.00 0

0.00 1

7.69 0

0.00 2.8 TO 3.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 3,0 TO 3.2 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 3.2 TO 3.4 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 J.4 TO 3.6 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

  • 0.00 3.6 TO 3.8 0

0.00 0

0.00 0

0.00 o

0.00 0

0,00 0

0.00 3.8 TO 4.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.0 TO 4.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 4.5 TO 5.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5.0 TO 5.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0,00 0

0.00 5.5

  • ro 6.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.0 TO 6.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 6.5 TO 7.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 7.0 TO 7.5 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 7.5 TO 8.0 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 8.0 TO 9.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 9.0 TO 10.0 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 0

000 10,0 TO 11.0 0

000 0

0.00 0

0.00 0

0.00 o

0.00 0

0.00 11.0 TO 12.0 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 GT 12.0 0

0.00 0

0.00 0

000 0

0.00 0

0.00 0

0.00 TOTAL 2426 100,00 798 100.00 366 100.00 83 100.00 13 100.00 0

0.00 MAXIMUM AMT.

2.56 2.60 1.50 1.90 2.74 0.00 TOTAL PRECIPITATION FOR DATA PERIOD 191.33 INCHF.S NO.

PCT.

NO.

PCT.

OBSERVATIONS WITH NO PRECIPITATION 31 326 92.81 VALID OBSERVATIONS 33752 96.26 OBSERVATIONS WITH PRECIPITATION GE 0.01NCH 2426 7.19 INVALLID OBSERVATIONS 1312 3.74 TOTAL VALID OBSERVATIONS 33752 100.00 TOTAL OBSERVATIONS 35064 100.00 Rev. 35. 07/84

TABLZ 2.3-50 Pn<:IPITATION WI1'D ROSE JANUARY 1973 -

1976 WJNO WINO sP£ED CATEGOftIESCMETERS PER SECONOI MEAN l

SECTOR o.o-~.s 1.s-J.o 3.o-s.o s.0-1.s 1.!>-10.0

>10.0 fOUl SPEEO NNE l.111 8

0.08 0.08 0.08 0.08 1.n 1.53 J.88 NE 7

6 0

0 0

0 6.u l.56 3.40 2.91 o.oo o.oo o.oo o.oo EN£ 6

4 o.o&

0.08 0.08 0.08

.J~

1.44 2.9) t.94 E

J 6

0 0

0 0

9 2.09 le46 2.cu o.oo o.oo o.oo o.oo

... 37 ESE

... ~

8

.9~

J.88 0.08 0.08 0.08 9.n 1.10 SE 4

4 0.08

.9, 0

0.08

  • .13 z.Ja 1.9,.

o.oo SSE 1

5 1

I 0

0 6.1~

J.89 J *.-o 2.43

... 9

.49 o.oo o.oo

~

s 7

s J

0 0

0 15 z.oJ 3.40 2.43 1.46 o.oo o.oo o.oo 7.28 5

SSW 4

z 4

0 0

1.H 3.69 1.94

.97 Z.43 o.oo o.oo en.,.

en sw 4

4 J

0 0

0.08 s.ll 2.05 J.94 1.94 J.46 o.oo o.oo e

J 4

4

.. ~

0 0

6.u J.n 1.46 1.94 1.94 o.oo o.oo 0

16 2.10 9

0 4

J 0

4.37 o.oo 1.94 1.46 o.oo o.oo 1.11 6

2 0

l 0

0.08 9

1.eJ 2.91

.91 o.oo

.49 o.oo 4.37 NV IO t

0 0

0 0

s.ll 1.25 4.85

.49 o.oo o.oo o.oo o.oo

.'I;*

... w 7

0 I

0 0

0 J.el leJZ J.40 o.oo

... 9 o.oo o.oo o.oo N

1 l

0 0

0 0

6J; 1.s1 J.40 J.40 o.oo o.oo o.oo o.oo CAI.N

.9, CAI.N TOTAL 104lt 50.49 66 32.04 11.n 6.H 0.08 0.08 100!8!

2.0, ffil" I VM.18 CIRVATfONS "f TH PRtSAPITATlOft fij 6.9, ~T*

R,HJAl.

~AT He" THOUt ECIPITATION 2 70.9 T.

R 0, NY!l8e R¥AT 1 S

1H:hA J:

Q

~1

~6

_, AMOUNT lPITATI

,-OA OATA P(RIOO 1... oe 1NOs tit£Y JUUl ='tfflR 0/F ~NCES JUlJl P R NT 0C S

Rev. 35. 07/84

TABLE 2.J-51 PRECIPITATION wnm ROSI!:

FEBRUARY 1973 - 1976 I

WINO WINO ~PEED CATEGORJES<METERS P£R SECONOI

~

AH SECTOR 0.0-1.s 1.s-J.o J.o-s.o

~.0-1.s 1.s-10.0

>10.0 TOTAi.

S EEO NN[

7J~

s 0.08 0

0.08 0.08 10.U 1.32 J.12 o.oo NE 2

0 0

0 0

6 1.111 1.zs 2.so o.oo o.oo o.oo o.oo J.75 ENE J.rt 5

2 u

0.08 0

1J 1.96 3.12 l.zs o.oo o.oo 8.12 E

z 3

0 0

0 9

2.10 2.'50 1.2s 1.,n o.oo o.oo o.oo S.62 ESE J.11 z

0 0

0.08 0

7 1.26 I.lS o.oo o.oo o.oo 4.37 SE J.1) 3.7; 1

l 0.08 0.08 e.H 2.05

.62 e62 SSE 1

z 0

0 0.08 e.U 2.os 4.37 1.2s 2.so o.oo 0,00 s

2 1

6 z

0 lS

  • . ss 1.2s z.so

.62 3.75 1.2s o.oo 9.37 SSW 1.el

.61 J.7t 0.08 0.08 eJ~

4.37 z.so (II

~

SW 1.e1 0

0.08 0.08 0.08 0

1.e1

.83 o.oo o.oo e

WSW 1.2(

2 0

0.08 0

s.08 2.06 2.50 1.zs o.oo o.oo w

1 0

2 I

0 0

4 J.87

-62 o.oo 1.zs e62 o.oo o.oo 2.so WNW 1.111 6

.6}

0 0

0 6J3 l.9S 3.75 o.oo o.oo o.oo 1.2~

9

.6) 0 0.08 0.08 1.U z.u 5.62 o.oo NNW

.6}

1.2(

.6) 0 0

0 4

z.n o.oo o.oo o.oo z.so 9

J 0

0 0

0 12 1.21 5.62 1.87 o.oo o.oo o.oo o.oo 1.so CALN 0

o.oo 0.08 CALM TOTAL 69 lJ.U 13J{

eJt

.. ~

0 168 z.JJ

.,.12 o.oo 100.0

~

A f ¥ALf8 oe;*vATf~ "I'" PM.~PITATf°"

4to S.90 ~T*

=J:J~~- Is: ~:TA ~

THOUT CIPl AJION I !

7.94 P,.

~

-. ~

0¥1~

z9Y 1d:tt t:

TOT~ AMOUNT OF PR£ClPIT,UJOfil,-OR DATA ptAlOO

e. 2 INCHtS KEY al*,mf* o, ~~~~s XXX PR NT 0(

E E

TABLE 2.3-52 PRECIPITATION WINO ROSE FEBRUARY 1973

  • 1976 WIND WIND SPEED CATEGORIES (METERS PER SECOND)

MEAN SECTOR 0.0-1.5 1.5-3.0 3.0-5.0 5.0-7.5 7.5-10.0

>10.0 TOTAL SPEED NNE 3

6 0

0 0

0 9

1.92 1.36 2.71 0.00 0.00 0.00 0.00 4.07 NE 2

12 2

3 0

0 22 2.71 2.26 5.43

.90 1.36 0.00 0.00 9.95 ENE 3

11 6

1 0

0 21 2.70 1.36 4.98 2.71

.45 0.00 0.00 9.50 E

7 8

9 2

0 0

26 2.92 3.17 3.62 4.07

.90 0.00 0.00 11.76 ESE 3

4 4

0 0

0 11 2.41 1.36 1.81 1.81 0.00 o.oo 0.00 4.98 SE 3

6 3

0 0

0 12 2.14 1.36 2.71 1.36 0.00 0.00 0.00 5.43 SSE 3

2 0

1 0

0 6

1.97 1.36

.90 0.00

.45 0.00 0.00 2.71 s

5 4

2 2

0 0

13 2.53 2.26 1.81

.90

.90 0.00 0.00 5.88 SSW 7

2 3

1 0

0 13 2.23 3.17

.90 1.36

.45 0.00 0.00 5.88 SW 5

4 0

1 0

0 10 1.92 2.26 1.61 0.00

.45 0.00 0.00 4.52 WSW 3

5 2

5 0

0 15 3.21 1 36 2.26

.90 226 0.00 0.00 6.79 w

8 2

7 7

0 0

24 3.43 3.62

.90 3.17 3.17 0.00 0.00 10.86 WNW 4

0 1

4 1

0 10 4.20 1.81 0.00

.45 1.81

.45 0.00 4.52 NW 5

0 2

0 0

0 7

1.60

~r ;:,e 0.00

.90 0.00 0.00 0.00 3.17 NNW 2

6 1

1 0

0 10 2.62

.90 2.71

.45

.45 0.00 0.00 4.52 N

2 3

1 4

0 0

10 3.73

.90 1.36

.45 1.81 0.00 0.00 4.52 CALM 2

2 CALM

.90

.90 TOTAL 70 75 43 32 1

0 221 2.72 31.67 33.94 19.46 14.48

.45 0.00 100.00 NUMBER OF VALID OBSEHVATIONS WITH PRECIPITATION 221 7.43 PCT.

NUMBER OF VALID OBSERVATIONS WITHOUT PRECIPITATION 2730 91.73 PCT NUMBER OF INVALID OBSERVATIONS 25

.84 PCT.

TOTAL NUMBER OF OBSER.VA TIONS 2979 100.00 PCT.

TOTAL AMOUNT OF PRECIPI I A llON FOR DATA PERIOD 14.62 INCHES KEY XXX NUMBER OF OCCURRENCES xx,, PERCENT OCCURRENCES Rev. 35. 07/84

TABLE 2.3-53 PRECIPITATION WIND ROSE APRIL 1973 - 1976 WIND WIND SPEED CATEGORIES (METERS PER SECOND)

MEAN SECTOR 0 0-1.5 1.5-3.0 3.0-5.0 5.0-7.5 7.5-10.0

>10.0 TOTAL SPEED NNE 4

14 8

0 0

0 26 253 1.79 6.25 3.57 0.00 0.00 0.00 11.161 NE 4

10 32 0

0 0

46 3.25 1.79 4.46 14.29 0.00 0.00 0.00 20.54 ENE 3

5 4

3 0

0 15 3.23 1.34 2.23 1.79 1.34 0.00 0.00 6.70 E

4 4

4 0

0 0

12 2.26 1.79 1.79 1.79 0.00 0.00 0.00 5.36 ESE 4

1 1

0 0

0 6

1.83 1.79

.45

.45 000 0.00 0.00 2.68 SE 2

0 0

0 0

0 2

.80

.89 0.00 0.00 0.00 0.00 0.00

.89 SSE 6

2 0

1 0

0 9

1.81 2.68

.89 0.00

.45 0.00 0.00 4.02 s

7 1

3 1

0 0

12 2.29 3.12

.,45 1.34

.45 0.00 0.00 5.36 SSW 5

1 2

0 0

0 8

1.85 223

.45

.89 0.00 0.00 0.00 3.57 SW 7

4 1

o 0

0 12 1.51 3.12 1.79

.45 0.00 0.00 0.00 5.36 WSW 4

16 5

2 0

0 27 2.70 1.79 7.14 2.23

.89 o.oo 0.00 12.05 w

4 4

8 1

0 0

17 3.02 1.79 1.79 3.57

.45 0.00 0.00 7.59 WNW 0

2 7

3 0

0 12 4.34 0.00

.89 3.12 1.34 0.00 0.00 5.36 NW 1

0 4

1 0

0 6

3.42

.45 0.00 1.79

.45 0.00 0.00 2.68 NNW 1

2 3

2 D

0 8

3.69

.45

.89 1.34

.89 0.00 0.00 3.57 N

2 2

1 0

0 0

5 1.98

.89

.89

.45 0.00 0.00 0.00 2.23 CALM 1

1 CALM

.45

.45 TOTAL 59 68 83 14 0

0 224 2.75 26.34 30.36 37,05 6.25 0.00 0.00 100.00 NUMBER OF VALID OBSERVATIONS WITH PRECIPITATION 224 7.76 PCT.

NUMBER OF VALID OBSERVATIONS WITHOUT PRECIPITATION 2604 90.42 PCT.

NUMBER OF INVALID OBSERVATIONS 52 1.81 PCT.

TOTAL NUMBER OF OBSERVATIONS 2880 100.00PCT.

TOTAL AMOUNT OF PRECIPITATION FOR DATA PERIOD 14.92 INCHES KEY XXX NUMBER OF OCCURRENCES XXX PERCENT OCCURRENCES Rev. 35. 07/84

Rev. 35r 07/84 TABLE 2.3-54 PRECIPITATION WIND ROSE MAY 1973 - 1976 Wl!W SECTOR

  • lND SPEED CATEGO~IEStMETERS PER SECONO) 0.0-1.s 1-s-J.o J.o-s.o s.0-1.s 1.s-10.0 NNE N£ ENE E

ESE SE SSE s

ssv sv WNV NNW N

CALM TOTAL 4

5 0

0 0

l.80 2.25 o.oo o.oo o.oo S

10 1

0 0

2.2s 4.so

.*s o.oo o.oo 10 7

0 0

0 4o50 3.15 0.00 OoOO OoOO 7

3.15 5

2.2s s

2.2s 9

4.05 8

3.60 8

J.60 8

J.60 4

1,80 8

3,60 6

2.10 J

I.JS s

2.2s 5

2.25 s

2.25 J

1.35 1

.45 10 4.50 4

1.eo 2

.90

,.Jg 8

J.60 13 5.86 3

1.JS 4

1.eo J

1.JS 4

1.eo 92 41...,.

0 o.oo 0

o.oo 0

o.oo 4

1.80 4

1.80 2

.90 0

o.oo J

1.35 6

2.10 z

.90 0

o.oo

.. ~

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo

'5 2.2s 0

o.oo 0

o.oo

.. ~

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo IA! VAlf8 fUAVATfONS WfTH PAtClPITATlON 222 R.!JAL RVAT OHS w THOUT PNECIPITATION 270S R

N'IA\.I SERVATlONS 49 AL R Of' S RVAT IONS

l97t, TOTAL AM()IJHT Of' PAE.ClPJTATlON f'OQ DAU P[RlOO KEY XXX NUN8£R OF OCCURRENCES JIU PERCENT OCCVW~f."IC(S

>10.0 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0.08 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0.08 0

o.oo 0

o.oo 0

o.oo 0.08 0

o.oo 0.08 TOTAL 9

  • . os 1.U 17 7.66 12 5.41 8

3.60 6

z.10 23 10.36 16 1.21 12 5.41 18 e.11 15 6.76 32 14.41 11 4.95 7

3.1s 9.89 PT.

7.46 P~T*

10!.oo Pr.

16.?5 INCHCS MEAN SPEED 1.58 1.90 1.sz 1.11 2.00 2.08 1.66 1.67

TABU 2.3-55 PUCIPITATION WlMO ROSE JUNE 1973 -

1976 VINO WINO SPEEO CATEGOQIES(METERS PER SE~ONO>

ME:AN SECTOR 0.0-1.s 1.s-J.0 J.o-s.o s.0-1.s

.s-10.0

>10.0 TOTAL sPEEO NNE 7

4 0

0 0

0.08 5JA 1.43 J.18 1.e2 o.oo o.oo o.oo NE 19 9

3 0

0.08 0

1-Ji le62 8.6't 4.09 1.36 o.oo o.oo E!!E 11 12 l

0 0

0 24 1.11 5.00 5.45

.45 o.oo o.oo o.oo I0.91 E

11 10 l

0 0

0 28 le47 7.73 4.55

.45 o.oo o.oo o.oo 12.73 ESE 4

4 0

0 0

9 1.89 1.az 1.e2 o.oo o.oo o.oo 4e09 SE

.* i 8

0.08 0

0 0

9 1.e1 J.64 o.oo o.oo o.oo

4 0

0 0

0 s.U I.JO J.te 1.e2 o.oo o.oo o.oo o.oo s

e z

z 0

0 0

12 1.ss J.64

.91

.91 o.oo o.oo o.oo 5.45 SSW 1.Ji 0.08 0.08 0.08 0.08 3.11 1.59 1.82 sv sJ~

2.21 0

0 0

0.08 1J9 1.48 o.oo o.oo o.oo 1111S11 8

3.64 8

2 3.64

.91 0

0.08 0.08 o.oo a.ti 1.68 g

w 9

9 J

0 0

0 21 1.95 4.09 4.09 1.36 o.oo o.oo o.oo

  • -ss WNW 4

2 1

0 0

0 1

1.86 J.82

.91

.45 o.oo o.oo o.oo 3.18 NV 3

.. ~

0 0

0 0

4 1.1s 1.J6 o.oo o.oo o.oo o.oo 1.e2 NNV s

z 0

0 0

0 1

1.29 2.21

.91 o.oo o.oo o.oo o.oo J.18 N

2 l

1 0

0 0

4...,

.91

.45

.45 o.oo o.oo o.oo s.ez CAlM

--~

CAI.M TOTAL 1i1 84 l'S 0

0 0

10o!H 1.62 515. 0 J8.18 6.82 o.oo o.oo o.oo

~A~ VALJ8 PDAVATfS::L"IT" PAESAP!JATIOH Z~J A,!JAL

~AT W THOVT E

P!YATlON 24 R OF NY~I AVAtl S

ii8 R

09 YloTlON~

2 0

TOTAL AlleOUNT 0~ PAECJPITATl FOR DATA PEAIOO 8 -

It PT.

~*n pi'*

1.

p,.

100.oS PT.

18.49 INCHl(S

{ev. 35, 07/84

-.;[y UX ~It OF ~C=~ES

.llllll A

~T 0C \}fl £

(

.f

~ev. 35, 07/84 WINO SECTOR NJ,jE NE l

ESE SE SSE s

SSW SW WSW NW NNW N

CALM TOTAL TABLE 2.3-56 PRECIPITATION WINO ROSE JULY 1973 -

1976 Wl~D SPEED CATEGORIES<METERS PER SECOND) 0.0-1.s 1.s-J.o J.o-s.o s.0-1.s 1.5-10.0 6

3.41 11 6.25 8

4.55 11 6.25 2

lol4 2

1.14 1

.57 3

1.10 9

s.11 9

s.11 1

3.98 6

3;,41 11 6.25 3

1.10 5

2.84 3

1.10 6

3.41 4

2.21 2

1.14 3

l. 70 1

.57 1

.57 4

2.21 5

2.a..

3 1.10 4

2.21 s

2.84 0

o.oo 1

.57 1

.51 l

.57 0

o.oo 0

o.oo 0

o.oo 0

o.oo l

.57 I) o.oo 0

o.oo 0

o.oo 4

2.21 9

Soll 4

2.21 4

2.21 J

1.10 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 1

.S7 0

o.oo 0

o.oo

.5J 0

o.oo 2

1....

0 o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo NUMBER or YAl.1O OBSERVATIONS WITH PRECIPITATION NV148ER gr YALIO OBSERVATIONS WJTHOVT P~iCI~ITATlON NVM8(R F

NVALlO OAS[RVATl~S TOTAL NVM8[R OF 08S(RVAllONS 17'1 2798 2

297()

TOTAL A.-OUNT or PA(ClPlTATION FOW OATA PEWIOO KEV

>10.0 0

o.oo MEAN TOTAL SPEEO 8

1.35 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 0

o.oo 4.55 18 10.23 12 6.82 13 7.39 5

Z.84 J

1.10 J

1. 70 7

3.98 14 7.95 12 6.82 eJ) 21 11.93 15 e.s2 8

4.55 6J~

9 s.11

.sl 176 100.00 5.91 PCT.

9,..02 PCT.

.07 PCT.

100.00 PCT.

1a.qo INCHES 1.48 l

  • 19 1.10 2.01 1.)6 1.37 2.13 2086 1.63 CALN t.79 t'II "' '

"Ill "'

~

TABLE 2.3-57 PRECIPITATION WIND ROS.I'!

AUGUST 1973 -

1976 WJNO WINO SPEEO CATEGORlES~METERS PER SECONO)

MEAN SECT<m 0.0-1.s 1.s-J.o 3.o-s.o s.0-1.s 1.s-10.0

>10.0 TOTAL SPEED NNE 7

10 1

0 0

0 18 1.79 J.83 5.46

.ss o.oo o.oo o.oo 9.84 NE 4.39 6Ji 4

0 0

0 24 1.98 2.19 o.oo o.oo o.oo

13. 11 tNE 9

2 2

0 0

0.08 1.15 1.s1 4.92 1.09 1.09 o.oo o.oo E

8

)

0 0

0 0

11 1.11 4.37 1.64 o.oo o.oo o.oo o.oo 6.01 ESE 15 3

0 0

0 0

9.ll 1.11 e.20 l.64 o.oo o.oo o.oo o.oo SE 4

0 0

0 0

0 4

.9z 2.19 o.oo o.oo o.oo o.oo o.oo 2.19 SSE 0

0 0

0 0

0 0.08 o.oo o.oo o.oo o.oo o.oo o.oo o.oo s

3 0

0 0

0 0

3

.10 1.64 o.oo o.oo o.oo o.oo o.oo lo64 SSW 7

.s!

0 0

0 0

e 1.10 3.83 o.oo o.oo o.oo o.oo 4.37 r,,

SW 12 6.M 0

0 0

0 12Jl 1.ss 6.56 o.oo o.oo o.oo o.oo

~

WSW 1.0~

11 1.0~

0 0

0 eJ~

z. 17 11:i 6.01 o.oo o.oo o.oo 7

10 3

0 0

0 20 2.12 J.83 5.46 t.64 o.oo o.oo o.oo 10.93 7

1 1

0 0

0 9

1.20 3.83

.ss

.ss o.oo o.oo o.oo 4.92 NW

.s!

2 0

0 0

0 J

l.63 1.09 o.oo o.oo o.oo o.oo 1.64 NNW 2

z 0

0 0

0 4

1.37 1.09 1.09 o.oo o.oo o.oo o.oo 2.19 N

1 1

1 0

0 0

9 1.49 3.83

.ss

.55 o.oo o.oo o.oo 4.92 CALI'!

.s~

.si CALM TOTAL 100 69 14 0

0 0

183 lo60 54.64 37.70 7.65 o.oo o.oo o.oo 100.00 HUMeER or VAL[O O~SEPVAT[ONS WITM PRECIPITATION 183 6.~s PCT.

NU"8fR OF lALIO o~~~RVATlON&wlTNOVT PNECJµlYATION Z791

'ill3. 8 PCT.

"8"8 R or NVAl8 SER¥ATI s

2

.01 P~T*

T TA~ NVM9 RO 8lERiA IONS 2976 100.~~ Pr.

TOTAL AMOUNT 0* PR Cl ITATlON FOR OATA PERIOO l4.

lNCHES Rev. 35, 07/84 ICEY AAA ~M~fA OF OC£~Rf~ES XXX PR NT OCCV lN ES

Rev. 35, 07/84 TABLE 2.3-58 PRECIPITATION WIND ROSE SEPTEMBER 1973 - 1976 WIND WIND SPEED CATEGORIES (METERS PER SECOND)

MEAN SECTOR 0.0-1.5 1.5-3.0 3.0-5.0 5.0-7.5 7.5-10.0

>10.0 TOTAL SPEED NNE 18 6.08 18 6.08 2

.68 1

.34 0

0.00 0

0.00 39 13.18 1.77 NE 22 7.43 30 10.14 8

2.70 0

0.00 0

0.00 0

0.00 60 20.27 1.98 ENE 16 5.41 15 5.07 11 3.72 0

0.00 0

0.00 0

0.00 42 14.19 2.13 E

13 4.39 9

3.04 5

1.69 1

.34 0

0.00 0

0.00 28 9.46 1.93 ESE 6

2.03 3

1.01 0

0.00 0

0.00 0

0.00 0

0.00 9

3.04 1.38 SE 4

1.35 1

.34 0

0.00 0

0.00 0

0.00 0

0.00 5

1.69 1.00 SSE 8

2.70 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 8

2.70

.96 S

5 1.69 1

.34 0

0.00 0

0.00 0

0.00 0

0.00 6

2.03

.88 SSW 11 3.72 3

1.01 1

.34 0

0.00 0

0.00 0

0.00 15 5.07 1.13 SW 8

2.70 10 3.38 2

.68 0

0.00 0

0.00 0

0.00 20 6.76 1.82 WSW 3

1.10 10 3.38 2

.68 0

0.00 0

0.00 0

0.00 15 5.07 2.05 W

4 1.35 8

2.70 3

1.01 0

0.00 0

0.00 0

0.00 15 5.07 2.15 WNW 3

1.01 3

1.01 0

0.00 0

0.00 0

0.00 0

0.00 6

2.03 1.68 NW 4

1.35 2

.68 0

0.00 0.

0.00 0

0.00 0

0.00 6

2.03 1.17 NNW 5

1.69 0

0.00 0

0.00 0

0.00 0

0.00 0

0.00 5

1.69 1.12 N

5 1.69 5

1.69 0

0.00 0

0.00 0

0.00 0

0.00 10 3.38 1.48 CALM 7

2.36 7

2.36 CALM TOTAL 142 47.97 118 39.86 34 11.49 2

.68 0

0.00 0

0.00 296 100.00 1.74 NUMBER OF VALID OBSERVATIONS WITH PRECIPITATION 296 10.28 PCT.

NUMBER OF VALID OBSERVATIONS WITHOUT PRECIPITATION 2574 89.28 PCT.

NUMBER OF INVALID OBSERVATIONS 10

.35 PCT.

TOTAL NUMBER OF OBSERVATIONS 2880 100.00 PCT.

TOTAL AMOUNT OF PRECIPITATION FOR DATA PERIOD 30.17 INCHES KEY XXX NUMBER OF OCCURRENCES XXX PERCENT OCCURRENCES

TABLE 2.3-59 PRECIPITATION WIND ROSE OCTOBER 1973 -

1976 WIND Wll>fD ~PEED CATEGO~IES(METERS PER SECOND I M~AN SECTOR 0.0-1.s 1.s-J.o 3.o-s.o s.0-1.s 1.s-10.0

>10.0 TOUl.

S EEO NNE II 19 4

0 0

0 31 2.18 J.52 8.37 1.76 o.oo o.oo o.oo 13.66 NE 12 26 14 0

0 0

52 2.31 5.29 11.4~

6. 1 7 o.oo o.oo o.oo 22.91 ENE 10 15 3

l 0

0 12J:

2.08 4.41 f>.61 1.Jz

.44 o.oo o.oo E

13 4

0 6

0 0

23 2.64 5.73 l

  • 7(,

o.oo Z.64 o.oo o.oo 10.13 E~E 4

0 0

0 0

0 4

.81 1.76 o.oo o.oo o.oo o.oo o.oo 1.76 SE 2

0 0

0 0.08 0

.el 1.os

.88 o.oo o.oo o.oo o.oo SSE 2

0 0

0 0

0 2

.80

.ea o.oo o.oo o.oo o.oo o.oo a88 s

5 l

0 0

0 0

6 1.03

\

2.20

.44 o.oo o.oo o.oo o.oo 2.64 SSW 7

2 0

0 0

0 9

1.36 V,

J.oa e88 o.oo o.oo o.oo o.oo 3.96 SW 3

3 0

0 0

0 1.63 6

J.32 1.32 o.oo o.oo o.oo o.oo 2e64 WSW 1

4 7

3 0

0 21 2.97

~

3.08 lo76 3.0tl 1.32 o.oo o.oo 9.25

~

w z

1 2

2 0

0 7

J.16

.88 044

.88

.118 o.oo o.oo J.08 lfNIII 5

3 0

l 0

0 10 2.20 2.20 1.32 o.oo

.88 o.oo o.oo 4.41 NW 0

J 1

0 0

0 2.62 o.oo 1.32

  • 44 o.oo o.oo o.oo 1.76 NNW 1

l 0

0 0

6 1.57 1.76 a44 o.oo o.ou o.oo 2.64 N

7 3

4 0

0 0

14 2.11 J.01:1 1.32 1.76 o.oo o.oo o.oo 6.17 CAlM 1

1 CAt.M

.44

.44 TOTAi.

,.oJi 115

)6

)4 0

0 227 2.20 37 _,.,.

15.86 6.17 o.oo o.oo 100.00 NUMBiQ o, VAlIO gss~RYATIONS WITM P~EClPlTATlON

~27 7.6~ PCT.

NUM8 R OF !At.IO s6 RYATIONS WITMOUT PMECl~ITATION 2 3,2 91.tl PCT.

N~M8 R or N~A~lO ASERVATIONS z9lZ

.57 PCT.

T TAL NVf48 RO 08$t:RVAT10NS 100.00 PCT.

TOTAi. AMOUNT OF PRECIPlTAtlON FOR OATA PERIOO 11.ss INCHES Rev. 35, 07/84 IC[Y XXX m~ER OF O~~RENCES XXX P RC(NT OCC (NC(S

  • - - -~-

J TABLE 2.3-60 PRECIPITATION WIND ROSE NOI/F.MBER 1973 -

197~

I WINO

._l.. D ~PEED CATEGO~lESIMETEHS PER SECONOJ MEAN SECTOR 0.0-1.s l*S-J.O J.o-s.o s.0-1.s 1.s-10.0

>10.0 TOTAl SPEED NNE s

4 0

0 0

0 9

l.&4 z.91 Z.JJ o.oo o.oo o.oo o.oo 5.23 NE 4

4 l

0 0

0 9

1. 74 2.n 2.33

.sa o.oo o.oo o.oo 5.23 ENE

~

4 0

0 0

0 12 1.21 4.65 2.33 o.oo o.oo o.oo o.oo 6.98 E

l 0

0 0

0 5

.96 z.33

.56 o.oo o.oo o.oo o.oo 2 91 ESE 0

0.08 0

0 0

0 0.08 o.oo o.oo o.oo o.oo o.oo o.oo SE J

0 0

0 0.08 0

1.11

.73 lo 74 o.oo o.oo o.oo o.oo SSE 6

2 0

0 0

0 4.6~

1.2i J.49 1.16 o.oo o.oo o.oo o.oo s

7 12 2

2 0

0 23 2.33

\

... 01 6.fl~

1.16 1.16 o.oo o.oo 13.37 SSW 5

2 0

0 0

12 l.91 2.91 2.91

1. 16 o.oo o.oo o.oo 6.98

(J)

SW 9

4 0

0 0.08 0

13 I

'::,.23 2.33 o.oo o.oo o.oo 7.56 WSW ti 8

14 1

0 37 3.33 Cl>

0

?:;

4.65 4.65

e. l'+

4.07 o.oo o.oo 21.s1 7

3 10 0

0 0

20 2o46 4.07

].74

5. !:!l o.oo o.oo o.oo 11.63 WNli' 1

0 2

0 0

0 J

3.53 Sb o.oo 1.16 o.oo o.oo o.oo 1.74 NW 0

0 l

0 0

0 1

J.80 o.oo n.oo

.St!

o.oo o.oo o.oo

.sa NNW 1

2 0

0 0

0 3

t.93

.St!

].16 o.oo o.oo o.oo o.oo

1. 74 N

9 2

0 0

0 0

11 l.zo s.ZJ 1.16 o.oo o.oo o.oo o.oo 6.40 CALM J

J CAlM 1.1..

l. 74 TOTAL so
,gJ~

32 9

0 0

17Z loll 46.51 ld.60 5.2J o.oo o.oo 100.00 NUM81R OF VALl8 OBSEW~ATIONS WITH ~RECJPITATION

~1Z 1.97 PfT*

NUM8 R gr V~LI O~SijWVATlO~S WIT"OUT PWECIPITATION 2 Sl fl 06! PT.

NMM8 Q F lN~A,10 0 S[WVATIONS lS.6

~.4 P~T.

T TAL NUM8(Q O 08SEWVAT10NS 21!~0 100.00 PT.

TOTAL A~OVNT 0~ PWlCIPJTATION FOW OATA PERIOO l0.6) lNCH!S Rev. 35, 07/84 KEV XXX ~"~fq or OCC~RRENCES XXX p we NT OCCUP lNCtS I

TABLE 2.3-61 PR!lCIPITATION 'lnND ROSE DECEMBER 1973 - 1976 1

WlNO

._IND SPEED CATEGORIEStMET~RS PER SECONO>

MEAN SHTOA 0.0-1.s 1.s-J.o 3.o-s.o s.0-1.s 1.s-10.0

>10.0 TOTAL SPEEO NNE 1

3 l

o.o&

0 0

5 l.96 l.Jo 3.90 1.Jo o.oo o.oo 6.49 NE 0

l4 z

0 0

0 20Jt 2.37 o.oo 1 e. 1e Z.60 o.oo o.oo o.oo ENE 0

z 1

0 0

0 3

2.ttJ o.oo 2.60 l.JO o.oo o.oo o.oo J.9o E

1 0

0 0

0 0

l 1.10 l

  • 30 o.oo o.oo o.oo o.oo o.oo 1.Jo ESE 2

0 0

1 0

0 3

2.40 2.60 o.oo o.oo I.JO o.oo o.oo Jo90 SE 1

0 1

0.08 0

0 2-6~

2.95 1.30 o.oo 1.30 o.oo o.oo SSE 0

0 0

0 0

0 0

o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo s

4 6

0 0

0 0

10 1.88

'5.19 7.79 o.oo c,.oo o.oo o.oo 12.99 SSII 4

5 l

0 0.08 0

12JS 1.85 VI

5. l ',I 6.49 1.30 o.oo o.oo SIi 6

3 1

0.08 0

0.08 10 1.51 7.79 3.90 1.30 o.oo 12.99 WSW 1

2 1

0 0

0 4

1.es e

1.30 2.60

1. 30 o.oo o.oo o.oo 5.19 w

0 1

0 3

0 0

It 5.60 o.oo 1.30 o.oo 3.90 o.oo o.oo s.19 WNW 2

l 0

2 0

0 5

2.12 2.60 1.Jo o.oo 2.60 o.oo o.oo 6.49 NW 0

1 0

0 0

0 1

1.eo o.oo 1.30 o.oo o.oo o.oo o.oo I.Jo NNW 0

0 0

0 0

0 0

o.oo o.oo o.oo o.oo o.oo o.oo o.oo o.oo H

0 1

0 2

0 0

3 4.83 o.oo 1.Jo 0.00 2.60 o.oo o.oo 3.90 CALM 0

o.oo 0.08 CAlM TOT.Al ze.~~

39 ti 8

0 0

77 2.35 S0.65 10.3~

10.39 o.oo o.oo 100.00 NUMBIR 8F v*~fO gss1~VATl~S W(TH PAESlPITATlON 17 z.s9 P~f*

NVM8 R r VA~ 0 S RYATI

~ W TNOVT

~ECl~lTATION n~f Sl.14 p Te N~ R OF lNVA~lU O SERYATJ NS 46.27 PCT.

T TAL NVM8 RO 08SE~VATIONS 297b 100.00 PCT*

TOTAL AMOVNT OF PR(CJPJTATION roR OATA PERIOD 8.82 INCHES Rev. 35, 07/84 ICEY

      • ~tR Of" occ~~NCES KXX P we NT OCCUW f (S

TABLE 2.3-62 PRECIPITATION WIND ROSE JANUARY 1973 -

DECEMBER 1976 WINO IIHN0 ~PEE0 CATEG0RIEStMETERS PER SECOND)

MEAN SECTOR ooo-10s IoS-3.o 3.o-5.o soo-1.s 7os-10.o

>10.0 TOTAL SPEED NNE 83 97

.H 1

0 0

198 t.8..

3o48 4.07 004 OoOO o.oo 8031 HE 99 143 68 3

0 0

313 2.20

4. 15 6.00 2.A5 o 13 o.oo o.oo 13.13 ENE 90 86 JO s

0 0

21~

lo99 3.78 J.61 1.2,-

.21 o.oo o.oo 8.8 E

92 54 22 0

0 177 1.96 3086 2.21

.92

.31, OoOO OoOO 7.42 ESE 2J~

31 8

l 0

0 10g 1.59 lo30 034

.o..

o.oo o.oo

4. l SE
  • . ~?

27 5

J 0

0 71 lo 74 lol3

.21

.lJ o.oo o.oo 2.98 SSE 56 28 10 3

0 0

97 1.1z 2o35 1.11 04-2

.13 OoOO o.oo 4o07 s

64 44

)7 11 2

0 138 2.24 2.68 l o8S

.11 046

.oa o.oo 5.79 SSW 74 32 20 11 0

0 137 2.11 J.10

l. 34

.~4 o4f>

o.oo o.oo s.15 SW 85 61 7

l 0

0 154 lo61 3.57 2.56

.29

.o..

OoOO OoOO 6046 WSW 54 82 48 19 0

0 203 2.64 2.21 3o44 2o0l

.1:10 o.oo OoOO 80'52

~

w 65

'56 57 23 0

0 201 2.15 2.13 2.35 2.39

.96 o.oo o.oo 8.43 WNW

'52 23 19 12 1

0 107 2.39

2. 18

.96 oAO

.so

.o..

o.oo 4o49 HW 32 24

.M l

0 0

10 1.96 lo34 1.01

.o..

OoOO OoOO 2o94 NNW 38 23 11 5

0 0

77 2o08 lo59

.96 046

.21 o.oo o.oo 3.23 N

58 38 8

6 0

0 110 1.88 2o4.J l.'.,9

.J..

.2, OoOO o.oo

.. ob l CALM 20 20 CALM

.84

.f!I..

TOTAL 1058 849 360 11..

3 0

2384 2.oe 440)8 JS.bl 1 s_,. l O

... 78

  • l J OoOO 100000 NUM8fR ~ v*LIO OB!EHVAT}Ot-t! WfTH P~£slPITATION

$~~4 6080 P~T*

NVM8 R f YALIO 0~

WVAT ON W THOVT WECIPITATI0NZ J

15,.. 20 p,.

N8M8£R Of NVAIO ~SERVATl NS

~15 q.oo PCT.

J TAL NVM8[R O OBS~R~AllO~S J 064 1og.oo PCT.

TOTAL AMOUNT Of PN[ I lTATlON FON UATA PEAIOO U:!.22 lNO~S Rev. 35, 07/84 t([y Jtllll ~

lil8£R OF OCC~A£NC[S All.JI.

WC(~T OCCVW ENCES

SSES -

FSAR TABLE 2.3-63 HEAVY FOG (VISIBILITY 1/4 MILE OR LESS) AT AVOCA, PA. (Rev. 2.3-11)

YEAR Month 1972 1973 1974 1975 January 3

3 0

3 February 0

0 1

3 March 1

3 1

2 April 2

2 0

1 May 3

3 0

0 June 2

0 1

2 July 5

2 0

0 August 0

1 2

4 September 1

2 7

3 October 3

4 2

0 November 0

1 2

3 December 8

2 0

3 Annual 28 23 16 24 Rev. 48, 12/94

SSES -

FSAR TABLE 2. 3-64 JOINT FREQUENTY (I) OF WIND DIRECTION, WIND SPEED AND STABILITY (Ref. 2.3-4)

Stability Class A Wind Speed (kts)

Sector 0-3 4-6 7-10 11-16 17-21

>21 Total N

.0139

.0205 0

0 0

0

.0345 NNE

.0046

.0068 0

0 0

0

.0115 NE

.0230

.0000 0

0 0

0

.0230 ENE

.0046

.0068 0

0 0

0

.0115 E

.0000 0

0 0

0 0

0 ESE

.0046

.0068 0

0 0

0

.0115 SE

.0000 0

0 0

0 0

0 SSE

.0046

.0068 0

0 0

0

.0115 s

.0254

.0205 0

0 0

0

.0460 SSW

.0093

.0137 0

0 0

0

.0230 SW

.0046

.0068 0

0 0

0

.0115 WSW

.0139

.0205 0

0 0

0

.0345 w

.0186

.0274 0

0 0

0

.0460 SNW

.0093

.0137 0

0 0

0

.0230 NW

.0046

.0068 0

0 0

0

.0115 NNW

.0093

.0137 0

0 0

0

.0230 Total

.1507

.1712 0

0 0

0 Relative frequency of occurrences of A Stability=.3219 Relative frequency of calms distributed with A Stability=.1301 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations

SSES -

FSAR TABLE 2.3-65 JOINT FREQUENCY(%) OF WIND DIRECTION, WIND SPEED AND STABILITY (Ref. 2.3-4)

Stability Class B Wind Speed (kts)

Sector 0-3 4-6 7-10 11-16 17-21

>21

.2871 N

898

.1507

.1164 0

0 0

.3569 NNE 975

.0548

.0548 0

0 0

.2071 NE 654

.0548

.0616 0

0 0

.1819 ENE 1112

.0411

.0137 0

0 0

.1660 E

768

.0274

.0342 0

0 0

.1385 ESE 516

.0205 0

0 0

0

.0721 SE 528

.0274

.0068 0

0 0

.0870 SSE 424

.0137

.0137 0

0 0

.0698 s

1675

.0890

.0205 0

0 0

.2771 SSW 898

.1507

.0959 0

0 0

.3364 SW 991

.2055

.1507 0

0 0

.4553 WSW 1773

.2877

.2123 0

0 0

.6773 w

2118

.2493

.1301 0

0 0

.6913 WNW 1449

.1918

.1164 0

0 0

.4531 NW 1449

.1986

.0890 0.

0 0

.3856 NNW 748

.1096

.1027 0

0 0

.2871 Total 6507 1.9726 1.2192 Relative frequency of occurrences of B Stability= 4.8425 Relative frequency of calms distributed with B Stability=.5274 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations

SSES -

FSAR TABLE 2.3-66 JOINT FREQUENCY(%) OF WIND DIRECTION, WIND SPEED AND STABILITY {Ref. 2.3-4)

Stability Class C Wind Speed (kts)

Sector 0-3 4-6 7-10 11-16 17-21

>21 Total N

.0707

.2808

.3014

.0274 0

0

.6803 NNE

.0631

.1164

.0822

.0137 0

0

.2754 NE

.0488

.2055

.0959

.0137 0

0

.3639 ENE

.1069

.2671

.0685 0

0 0

.4425 E

.0712

.1233

.1233

.0068 0

0

.3246 ESE

.0132

.0616

.0411 0

0 0

.1159 SE

.0175

.0274

.0479 0

0 0

.0928 SSE

.0480

.0342

.0411

.0068 0

0

.1302 s

.0556

.1164

.1781

.0753

.0068 0

.1302 SSW

.0326

.1918

.5000

.1096

.00137 0

.8340 SW

.0413

.2055

.7877

.1507 0

0 1.1989 WSW

.0415

.3699

. 6164

.1027 0

0 1.1306 w

.0714

.2877

.3630

.0342 0

0

.7563 WNW

.0681

.1712

.3493

.0959 0

0

.6846 NW

.0613

.1781

.3836

.0890

.0068 0

.7188 NNW

.0313

.1781

.4178

.1096

.0068 0

.7347 Total

.8425 2.8151 4.3973

.8356

.0342 0

Relative frequency of occurrence of c stability= 8.9247 Relative frequency of calms distributed with c Stability=.3082 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations

Sector N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total SSES - FSAR TABLE 2.3-67 JOINT FREQUENCY (I) OF WIND DIRECTION, WIND SPEED AND STABILITY (Ref. 2.3-4)

Stability Class D Wind Speed (kts) 0-3 4-6 7-10 11-16 17-21

>21

.4311 1.2808 1.6027

.7671

.0137 0

.2648

.9041 l.0342

.1918

.068 0

.2677 1.0068

.8425

.3562

.0205 0

.4100 1.4452

.9863

.4726

.0274

.0137

.2648

.9041 1.0959

.3973

.0479 0

.1397

.5616

.5616

.1233

.0205 0

.1684

.3973

.3493

.1644

.0274

.0068

.1610

.5479

.5205

.4932

.0342 0

.4506 1.5479 1.8288 1.2945

.1027

.0068

.2837 1.2397 2.7123 1.4658

.0685

.0068

.2740 1.2192 3.3082 2.8699

.1507

.0205

.3542 1.1164 1.2945 1.2192

.1164

.0205

.2210

.9178

.7808

.8562

.1514

.0274

.1836

.5479 1.0753 1.7740

.2949

.0411

.1995

.7055 1.8767 2.5822

.2123

.0205

.2344

.6027 1.4589 1.5068

.0616 0

4.3082 14.9452 21.3288 16.5342

1. 3630

.1644 Total 4.0955 2.4018 2.4937 3.3552 2.7100 1.4068 1.1136 1.7568 5.2314 5.7768 7.8425 4.1213 2.9607 3.9165 5.5968

3. 8645 Relative frequency occurrence of D Stability= 58.6438 Relative frequency of calms distributed with D Stability= 1.7671 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations

--------~ ***-**-*- - ****--*****-

Sector N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW

. Total SSES -

FSAR TABLE 2.3-68 JOINT FREQUENCY(%) OF WIND DIRECTION, WIND SPEED AND STABILITY (2.3-4)

Stability Class E Wind Speed (kts) 0-3 4-6 7-10 11-16 17-21

>21 0

.3904

.4521 0

0 0

0

.2329

.0781 0

0 0

0

.2534

.0479 0

0 0

0

.6574

.2945 0

0 0

0

.7055

.6849 0

0 0

0

.3836

.6918 0

0 0

0

.2603

.1096 0

0 0

0

.4726

.1096 0

0 0

0 1.0753

.5685 0

0 0

0

.6906

.6507 0

0 0

0

.3973

.8288 0

0 0

0

.3836

.3014 0

0 0

0

.2123

.2534 0

0 0

0

.1575

.3151 0

0 0

0

.2740

.5137 0

0 0

0

.2055

.4178 0

0 0

0 6.6712 6.4178 0

0 0

Total

.8425

.3110

.3014

.9521

1. 3904 1.0753

.3699

.5822

1. 6438 1.2603 1.2260

.6849

.4658

.4726

.7877

.6233 Relative frequency of occurrence of E Stability = 13.. 0890 Relative frequency of calms distributed with E Stability= O Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations

Sector N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total SSES - FSAR TABLE 2.3-69 JOINT FREQUENCY (I) OF WIND DIRECTION, WIND SPEED AND STABILITY (2.3-4)

Stability Class F Wind Speed (kts) 0-3 4-6 7-10 11-16 17-21

>21

.~

.0986

.4247 0

0 0

0

.0335

.2466 0

0 0

0

.0813

.2945 0

0 0

0

.2463 1.1096 0

0 0

0

.2782 1.3356 0

0 0

0

.1387

.8562 0

0 0

0

.1323

.3836 0

0 0

0

.1647

.6164 0

0 0

0

.2420 1.2466 0

0 0

0

.1241

.6644 0

0 0

0

.0875

.4726 0

0 0

0

.1028

.3836 0

0 0

0

.0809

.1918 0

0 0

0

.0440

.1918 0

0 0

0

.0581

.3767 0

0 0

0

.0939

.3630 0

0 0

0 2.0068 9.1575 0

0 0

0 Total

.5232

.2800

.3758

l. 3559 1.6139

.9948

.5158

.7811 1.4886

.7885

.5601

.4864

.2727

.2358

.4348

.4569 Relative frequency of occurrence of F Stability= 11.1644 Relative frequency of calms distributed with F Stability=.7877 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observation

Sector N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NWN Total SSES - FSAR TABLE 2.3-70 JOINT FREQUENCY (I) OF WIND DIRECTION, WINO SPEED ANO STABILITY (2.3-4)

Stability Class G Wind Speed (kts) 0-3 4-6 7-10 11-16 17-21

>21

.0976 0

0 0

0 0

.0366 0

0 0

0 0

.1464 0

0 0

0 0

.3416 0

0 0

0 0

. 6467 0

0 0

0 0

.2684 0

0 0

0 0

.1342 0

0 0

0 0

.2562 0

0 0

0 0

.3782 0

0 0

0 0

.1586 0

0 0

0 0

.0732 0

0 0

0 0

.1342 0

0 0

0 0

.0732 0

0 0

0 0

.0732 0

0 0

0 0

.0732 0

0 0

0 0

.1220 0

0 0

0 0

3.0137 0

0 0

0 0

Total

.0976

.0366

.1464

.3416

.6467

.2884

.1342

.2562

.3782

.1586

.0732

.1342

.0732

.0732

  • 0732

.1220 Relative frequency of occurrence of G Stabiity = 3.0137 Relative frequency of calms distributed with G stability= 1.3219 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations

Sector N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total SSES -

FSAR TABLE 2.3-71 JOINT FREQUENCY (I) OF WIND DIRECTION, WINO SPEED AND STABILITY (2.3-4)

All stability Classes Wind Speed (kts) 0-3 4-6 7-10 11-16 17-21

>21

.8291 2.5479 2.4726

.7945

.0137 0

.5271 1.5616 1.3493

.2055

.0068 0

.6243 1.8151 1.0479

.3699

.0205 0

1.2294 3.5274 1.3630

.4726

.0274

.0137 1.2417 3.0959 1.9384

.4041

.0479 0

.5947 1.8904 1.2945

.1233

.0205 0

.5050 1.0959

.5137

.1644

.0274

.0068

.6638 1.6918

.6840

.5000

.0342 0

1.3470 4.0959 2.5959

1. 3699

.1092

.0068

.7359 2.8699 3.9589

l. 5753

.0685

.0068

.6186 2.5068 5.0753 3.0205

.1644

.0205

.8230 2.5616 2.4247 1.3219

.1164

.0205

.6589 l.9863

l. 5274

.8904

.1574

.0274

.5098 1.2740 1.8562 1.8699

.2945

.0411

.5091 1.7397 2.8630 2.6712

.2192

.0205

.5551 1.4726 2.3973 1.6164

.0685 0

11.9726 35.7328 33.3630 17.3699 1.3973

.1644 Relative frequency of occurrence of observations= 100 Relative frequency of calms distributed above= 4.8425 Rev. 48, 12/94 Wilkes-Barre/Scranton Airport 1971-1975 Three Hourly Observations Total 6.6579 3.6504 3.8778 6.335 6.7280 3.9235 2.3132 3.5747 9.5251 9.2153 11.4063 7.2682 5.2480 5.8455 8.0228 6.1099

Time 4 AM-9 PM 4 PM-9 PM Other Times Rev. 48, 12/94 SSES - FSAR TABLE 2.3-72 MIXING HEIGHTS (meters)

Spring Summer 706 510 1750 1816 1228 1163 Autumn Winter 562 774 1306 979 934 877

SSES-FSAR Table Rev. 55 TABLE 2.3-73 Heights of Meteorological Sensors 200 Foot Primary Tower 60M 10M SFC 10 Meter Parameter (849.8' MSL)

(685.8' MSL)

(653.21' MSL)

Nescopeck1 Tower 10 Meters Wind Speed 1

1 1

Wind Direction 1

1 1

Ambient Temperature 1

12 Dew Point Temperature 1

Temperature Difference (using the 10 m temperature 2

2 as reference)

P reci pitati on 1

10 Meter Backup Tower Parameter 10 Meters (622.8' MSL)

Wind Speed 1

Wind Direction 1

1.

Nescopeck supplemental tower added per PLA-2467.

2.

Measurements made at 8' height of tower.

FSAR Rev. 60

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-74 METEOROLOGICAL DATA RECOVERY RATES 1998 THROUGH 2003 1999 2000 2001 2002 2003 5 YR AVG Wind Speed 10m Primary Wind Speed 60m Primary 99.7 99.7 99.8 99.4 100.0 99.4 99.5 99.5 99.6 99.2 99.7 99.4 Wind Direction 10m Primary Wind Direction 60m Primary 99.7 99.6 100.0 100.0 100.0 99.3 99.4 99.5 99.7 99.7 99.8 99.6 Delta Temperature 60-10m A Primary 99.6 99.8 99.3 99.0 99.1 99.4 Temperature 10m Primary Dew Point 10m Primary 99.6 99.3 99.7 87.2 99.9 98.8 99.6 98.6 99.0 98.8 99.6 96.5 Precipitation 99.7 100.0 100.0 100.0 100.0 99.9 Composite Wind Speed 10m, Wind Direction 10m, Delta Temperature 60-10m 99.5 99.7 99.3 99.0 99.0 99.3 Wind Speed 60m, Wind Direction 60m Delta Temperature 60-10m 99.5 99.3 99.2 99.0 98.6 99.1

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-75 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =

01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse:

DT60-10 Stability Class A Delta Temperature Extremely Unstable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

1 0

0 2

3 11 28 4

0 0

0 0

49 NNE 0

0 0

3 1

28 58 4

0 0

0 0

94 NE 0

0 0

7 15 45 23 0

0 0

0 0

90 ENE 0

0 1

8 17 11 4

0 0

0 0

0 41 E

0 0

4 26 8

4 1

0 0

0 0

0 43 ESE 0

1 7

12 7

8 6

0 0

0 0

0 41 SE 0

0 2

6 14 33 20 0

0 0

0 0

75 SSE 0

0 2

6 19 36 14 1

0 0

0 0

78 S

0 0

2 10 28 62 63 1

0 0

0 0

166 SSW 0

0 0

12 38 105 88 4

0 0

0 0

247 SW 0

0 1

10 38 177 261 28 1

0 0

0 516 WSW 0

0 0

4 7

29 125 35 2

0 0

0 202 W

0 0

0 1

2 4

48 5

0 0

0 0

60 WNW 0

0 0

1 2

6 12 0

0 0

0 0

21 NW 0

0 0

0 1

0 6

3 0

0 0

0 10 NNW 0

0 0

1 0

1 12 4

0 0

0 0

18 Totals 1

1 19 109 200 560 769 89 3

0 0

0 1751 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 1751 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-76 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00 -

12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse: DT60-10 Stability Class B Delta Temperature Moderately Unstable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 1

0 1

5 9

42 8

0 0

0 0

66 NNE 0

0 0

3 20 47 34 3

0 0

0 0

107 NE 0

0 0

12 16 46 24 0

0 0

0 0

98 ENE 0

0 1

24 13 10 2

0 0

0 0

0 50 E

0 0

9 15 7

10 3

0 0

0 0

0 44 ESE 0

0 4

11 14 5

5 0

0 0

0 0

39 SE 0

0 2

10 11 16 11 0

0 0

0 0

50 SSE 0

0 0

4 11 11 6

0 0

0 0

0 32 S

0 0

2 11 14 38 21 0

0 0

0 0

86 SSW 0

0 1

11 39 55 28 3

0 0

0 0

137 SW 0

0 0

4 36 105 175 31 4

0 0

0 355 WSW 0

0 1

1 7

23 100 43 2

0 0

0 177 W

0 0

0 0

1 8

34 4

0 0

0 0

47 WNW 0

0 0

0 1

1 18 1

0 0

0 0

21 NW 0

0 0

0 1

5 10 2

0 0

0 0

18 NNW 0

0 0

0 4

8 19 3

2 0

0 0

36 Totals 0

1 20 107 200 397 532 98 8

0 0

0 1363 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 1363 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-77 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =

01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse:

DT60-10 Stability Class C Delta Temperature Slightly Unstable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 0

0 3

7 23 73 6

0 0

0 0

112 NNE 0

0 1

8 21 52 59 6

0 0

0 0

147 NE 0

0 0

12 24 45 20 0

0 0

0 0

101 ENE 0

0 2

25 20 14 4

0 0

0 0

0 65 E

0 1

7 19 8

8 3

0 0

0 0

0 46 ESE 0

1 6

15 16 10 3

0 0

0 0

0 51 SE 1

0 7

9 17 13 11 0

0 0

0 0

58 SSE 0

1 4

12 18 21 12 0

0 0

0 0

68 S

0 0

4 26 28 50 28 0

0 0

0 0

136 SSW 0

0 1

24 35 76 17 2

0 0

0 0

155 SW 0

0 1

18 43 146 186 37 1

0 0

0 432 WSW 0

0 1

3 11 38 139 61 7

0 0

0 260 W

0 0

0 8

7 7

51 21 1

0 0

0 95 WNW 0

0 0

0 2

14 31 1

0 0

0 0

48 NW 0

0 1

0 3

9 30 4

0 0

0 0

47 NNW 0

0 0

1 1

19 31 16 2

0 0

0 70 Totals 1

3 35 183 261 545 698 154 11 0

0 0

1891 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 1891 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-78 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =

01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse:

DT60-10 Stability Class D Delta Temperature Neutral Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

2 7

23 74 119 433 716 98 0

0 0

0 1472 NNE 1

16 64 214 267 519 324 15 0

0 0

0 1420 NE 9

33 119 276 281 418 164 6

0 0

0 0

1306 ENE 8

51 130 219 153 158 54 3

0 0

0 0

776 E

10 85 158 202 124 119 32 5

0 0

0 0

735 ESE 15 67 144 144 117 146 58 7

3 1

0 0

702 SE 7

53 110 219 169 200 121 14 1

0 0

0 894 SSE 10 38 74 163 158 179 89 9

1 0

0 0

721 S

3 26 84 210 204 257 106 7

0 0

0 0

897 SSW 0

15 54 220 242 368 139 2

0 0

0 0

1040 SW 1

8 29 193 242 594 864 170 7

0 0

0 2108 WSW 0

3 15 87 132 254 627 425 90 1

0 0

1634 W

0 1

6 38 80 196 396 172 35 0

0 0

924 WNW 0

2 4

23 49 157 314 108 19 0

0 0

676 NW 1

2 11 31 45 225 632 178 6

0 0

0 1131 NNW 0

4 8

33 52 268 752 280 8

0 0

0 1405 Totals 67 411 1033 2346 2434 4491 5388 1499 170 2

0 0

17841 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 17841 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-79 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =

01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse: DT60-10 Stability Class E Delta Temperature Slightly Stable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

1 14 28 90 138 144 53 2

0 0

0 0

470 NNE 3

33 112 324 269 254 79 1

0 0

0 0

1075 NE 13 124 289 551 197 159 54 0

0 0

0 0

1387 ENE 20 279 467 493 87 29 7

3 0

0 0

0 1385 E

41 378 361 154 33 29 5

0 0

0 0

0 1001 ESE 45 265 207 99 30 24 8

5 0

0 0

0 683 SE 37 201 229 152 48 50 23 10 4

0 0

0 754 SSE 19 109 183 213 95 63 40 6

0 0

0 0

728 S

10 75 216 413 193 151 49 18 0

0 0

0 1125 SSW 3

42 126 397 334 309 84 4

0 0

0 0

1299 SW 2

14 39 188 209 343 210 10 1

0 0

0 1016 WSW 0

4 12 64 80 83 61 14 3

0 0

0 321 W

2 1

9 36 33 37 19 4

0 0

0 0

141 WNW 0

2 7

16 23 34 13 0

0 0

0 0

95 NW 1

2 4

19 42 87 24 2

0 0

0 0

181 NNW 0

5 6

21 41 116 35 2

0 0

0 0

226 Totals 197 1548 2295 3230 1852 1912 764 81 8

0 0

0 11887 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 11887 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-80 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =

01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse:

DT60-10 Stability Class F Delta Temperature Moderately Stable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

1 5

6 25 11 5

2 0

0 0

0 0

55 NNE 5

21 34 66 32 9

1 0

0 0

0 0

168 NE 13 92 198 257 50 1

1 0

0 0

0 0

612 ENE 21 361 806 994 149 6

0 0

0 0

0 0

2337 E

44 371 356 149 9

0 0

0 0

0 0

0 929 ESE 23 160 122 15 0

0 0

0 0

0 0

0 320 SE 14 82 82 25 2

0 0

0 0

0 0

0 205 SSE 8

32 78 49 6

1 0

0 0

0 0

0 174 S

2 29 78 121 14 1

1 0

0 0

0 0

246 SSW 1

16 24 81 37 4

1 0

0 0

0 0

164 SW 1

4 15 38 21 19 2

0 0

0 0

0 100 WSW 0

0 5

6 4

3 1

0 0

0 0

0 19 W

2 2

3 5

0 1

0 0

0 0

0 0

13 WNW 1

0 0

2 2

1 0

0 0

0 0

0 6

NW 0

0 2

1 1

2 1

0 0

0 0

0 7

NNW 1

0 3

2 5

2 2

0 0

0 0

0 15 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 5370 Total Hours for the Period 43823 Totals 137 1175 1812 1836 343 55 12 0

0 0

0 0

5370

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-81 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse: DT60-10 Stability Class G Delta Temperature Extremely Stable Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

1 2

2 3

1 0

0 0

0 0

0 0

9 NNE 1

16 17 17 3

1 0

0 0

0 0

0 55 NE 2

71 168 162 19 1

0 0

0 0

0 0

423 ENE 8

167 690 1065 186 4

0 0

0 0

0 0

2120 E

13 120 219 102 3

0 0

0 0

0 0

0 457 ESE 4

63 55 9

0 0

0 0

0 0

0 0

131 SE 3

31 35 12 2

1 0

0 0

0 0

0 84 SSE 0

14 23 15 3

0 0

0 0

0 0

0 55 S

0 5

12 17 0

0 0

0 0

0 0

0 34 SSW 1

2 8

7 5

1 0

0 0

0 0

0 24 SW 0

2 3

1 0

1 0

0 0

0 0

0 7

WSW 0

1 0

0 0

0 0

0 0

0 0

0 1

W 0

0 0

0 0

1 0

0 0

0 0

0 1

WNW 0

0 0

0 0

0 0

0 0

0 0

0 0

NW 0

1 0

0 0

0 0

0 0

0 0

0 1

NNW 0

2 0

1 0

0 0

0 0

0 0

0 3

Totals 33 497 1232 1411 222 10 0

0 0

0 0

0 3405 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 3405 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 Table 2.3-82 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00 - 12/31/03 23:00 Total Period Elevation:

Speed: 10M SPD Direction:

10M WD Lapse:

DT60-10 Summary of All Stability Classes Delta Temperature Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

6 29 59 198 284 625 914 118 0

0 0

0 2233 NNE 10 86 228 635 613 910 555 29 0

0 0

0 3066 NE 37 320 774 1277 602 715 286 60 0

0 0

0 4017 ENE 57 858 2097 2828 625 232 71 6

0 0

0 0

6774 E

108 955 1114 667 192 170 44 5

0 0

0 0

3255 ESE 87 557 545 305 184 193 80 12 3

1 0

0 1967 SE 62 367 467 433 263 313 186 24 5

0 0

0 2120 SSE 37 194 364 462 310 311 161 16 1

0 0

0 1856 S

15 135 398 808 481 559 268 26 0

0 0

0 2690 SSW 5

75 214 752 730 918 357 1

0 0

0 0

3066 SW 4

28 88 452 589 1385 1698 276 14 0

0 0

4534 WSW 0

8 34 165 241 430 1053 578 104 1

0 0

2614 W

4 4

18 88 123 254 548 206 36 0

0 0

1281 WNW 1

4 11 42 79 213 388 110 19 0

0 0

867 NW 2

5 18 51 93 328 703 189 6

0 0

0 1395 NNW 1

11 17 59 103 414 851 305 12 0

0 0

1773 Totals 436 3636 6446 9222 5512 7970 8163 1921 200 2

0 0

43508 Number of Calm Hours for this Table 18 Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 297 Number of Valid Hours for this Table 1751 Total Hours for the Period 43823

SSES - FSAR Table Rev 36 FSAR Rev 64 Page 1 of 1 TABLE 2.3-84 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00-12/31/03 23:00 Total Period Elevation: Speed:

60M SPD Direction:

60M WD Lapse:DT60-10 Stability Class A Delta Temperature Extremely Unstable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 0

0 0

1 2

30 12 4

0 0

0 49 NNE 0

0 0

0 1

14 45 32 7

0 0

0 99 NE 1

0 1

11 16 23 47 11 3

0 0

0 113 ENE 0

2 2

11 12 9

3 0

1 0

0 0

40 E

0 0

2 5

9 5

1 0

1 0

0 0

23 ESE 0

0 2

6 4

8 5

5 0

0 0

0 30 SE 0

0 1

3 4

7 27 18 1

0 0

0 61 SSE 0

0 0

2 3

11 33 17 1

0 0

0 67 S

0 1

3 5

6 24 46 55 10 1

0 0

151 SSW 0

0 0

6 13 49 85 62 22 0

0 0

237 SW 0

0 0

8 12 49 239 169 28 1

0 0

506 WSW 0

0 0

2 2

13 85 121 34 3

0 0

260 W

0 0

0 1

2 0

26 40 3

0 0

0 72 WNW 0

0 0

0 1

1 5

9 0

0 0

0 16 NW 0

0 1

0 0

0 1

6 0

0 0

0 8

NNW 0

0 0

0 0

1 7

9 0

0 0

0 17 Totals 1

3 12 60 86 216 685 566 115 5

0 0

1749 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 1749 Total Hours for the Period 43823

SSES - FSAR Table 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-85 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00-12/31/03 23:00 Total Period Elevation: Speed:

60M SPD Direction:

60M WD Lapse: DT60-10 Stability Class B Delta Temperature Moderately Unstable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 0

0 1

3 8

27 27 3

0 0

0 69 NNE 0

0 0

4 10 22 57 19 5

0 0

0 117 NE 0

0 4

11 22 30 33 12 1

0 0

0 113 ENE 0

0 2

9 8

15 5

1 0

0 0

0 40 E

0 0

3 7

4 9

4 2

1 0

0 0

30 ESE 0

0 2

4 8

5 11 2

0 0

0 0

32 SE 0

0 1

6 0

10 12 10 2

0 0

0 41 SSE 0

0 0

0 1

4 20 5

0 0

0 0

30 S

0 0

0 3

6 10 28 22 3

0 0

0 72 SSW 0

0 2

2 11 31 47 25 13 1

0 0

132 SW 0

0 0

2 10 51 145 101 28 4

0 0

341 WSW 0

0 0

0 2

6 67 86 55 1

0 0

217 W

0 0

0 0

0 3

21 28 6

0 0

0 58 WNW 0

0 0

0 0

2 8

7 0

0 0

0 17 NW 0

0 0

0 3

2 13 5

1 0

0 0

24 NNW 0

0 0

0 1

3 10 12 1

1 0

0 28 Totals 0

0 14 49 89 211 508 364 119 7

0 0

1361 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 1361 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-86 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00-12/31/03 23:00 Total Period Elevation: Speed:

60M SPD Direction:

60M WD Lapse:

DT60-10 Stability Class C Delta Temperature Slightly Unstable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 0

0 2

6 9

45 43 1

0 0

0 106 NNE 0

0 0

9 18 30 74 37 5

0 0

0 173 NE 0

0 4

10 8

31 32 11 1

0 0

0 97 ENE 0

2 6

13 11 21 7

4 0

0 0

0 64 E

0 1

3 13 9

5 5

1 0

0 0

0 37 ESE 0

1 1

1 4

10 11 3

0 0

0 0

31 SE 0

0 3

6 7

14 16 8

2 0

0 0

56 SSE 0

1 1

3 7

10 15 7

3 0

0 0

47 S

0 0

5 9

11 23 37 23 6

0 0

0 114 SSW 0

0 0

15 18 52 57 27 9

0 0

0 178 SW 0

0 0

3 15 69 187 77 31 1

0 0

383 WSW 0

0 0

1 7

18 88 140 78 7

0 0

339 W

0 0

0 1

2 4

24 51 20 1

0 0

103 WNW 0

1 0

1 0

5 28 12 1

0 0

0 48 NW 0

0 0

0 0

3 26 12 2

0 0

0 43 NNW 0

0 0

87 124 310 683 480 165 9

0 0

68 Totals 0

6 23 87 124 310 683 480 165 9

0 0

1887 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 1887 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-87 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record =

01/01/99 1:00 -

12/31/03 23:00 Total Period Elevation: Speed:

60M SPD Direction:

60M WD Lapse:

DT60-10 Stability Class D Delta Temperature Neutral Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 6

5 45 52 159 578 343 50 0

0 0

1238 NNE 4

6 33 124 154 289 584 283 46 2

0 0

1525 NE 1

25 82 183 131 288 455 139 16 1

0 0

1321 ENE 3

26 60 106 83 169 143 35 3

3 0

0 631 E

4 28 50 71 60 146 156 26 14 1

0 0

556 ESE 1

26 39 52 51 107 170 54 12 1

3 0

516 SE 2

20 45 75 53 130 241 82 22 8

0 0

678 SSE 2

13 41 88 59 115 258 88 26 7

0 0

697 S

1 15 39 115 76 105 221 122 44 5

0 0

743 SSW 1

9 32 131 156 202 255 192 66 4

0 0

1048 SW 1

2 23 112 187 405 625 403 110 5

0 0

1873 WSW 0

2 9

26 70 177 583 849 678 99 9

0 2502 W

2 5

2 7

23 77 361 423 230 34 5

0 1169 WNW 0

1 3

8 13 75 329 238 107 7

0 0

781 NW 1

2 3

5 9

81 531 482 98 1

0 0

1213 NNW 0

2 3

23 18 86 550 506 133 0

0 0

1321 Totals 23 188 469 1171 1195 2611 6040 4265 1655 178 17 0

17812 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 17812 Total Hours for the Period 43823

SSES - FSAR Table Rev, 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-88 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00 -

12/31/03 23:00 Total Period Elevation: Speed:

60M SPDDirection:

60M WD Lapse:

DT60-10 Stability Class E Delta Temperature Slightly Stable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 16 28 57 93 197 190 25 1

0 0

0 607 NNE 2

19 66 254 364 482 331 101 12 0

0 0

1631 NE 4

51 139 373 200 277 277 82 6

0 0

0 1409 ENE 9

50 112 139 84 140 73 7

1 3

0 0

618 E

9 54 87 107 61 71 76 10 2

1 0

0 478 ESE 5

48 70 78 36 62 63 11 7

2 0

0 382 SE 6

33 61 103 63 68 85 30 16 7

0 0

472 SSE 4

37 71 130 61 132 163 38 22 5

0 0

663 S

5 24 75 141 108 154 242 81 42 14 1

0 887 SSW 5

8 47 126 136 183 434 190 59 2

1 0

1191 SW 1

14 33 108 136 324 579 213 29 1

1 0

1439 WSW 0

6 17 42 85 157 419 384 57 3

0 0

1170 W

0 3

11 22 26 57 81 29 8

1 0

0 238 WNW 0

2 2

6 11 68 77 6

0 0

0 0

172 NW 0

3 5

15 13 49 168 35 3

0 0

0 291 NNW 1

6 10 14 14 54 118 15 0

1 0

0 233 Totals 51 374 834 1715 1491 2475 3376 1257 265 40 3

0 11881 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 11881 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-89 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00 -

12/31/03 23:00 Total Period Elevation: Speed:

60M SPD Direction:

60M WD Lapse:

DT60-10 Stability Class F Delta Temperature Moderately Stable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

2 3

13 47 82 176 37 3

0 0

0 0

363 NNE 0

16 33 269 503 677 100 0

0 0

0 0

1598 NE 7

28 97 340 243 154 34 0

0 0

0 0

903 ENE 8

28 87 132 47 20 3

0 0

0 0

0 325 E

7 20 65 101 36 15 4

1 0

0 0

0 249 ESE 3

26 55 64 23 9

2 0

0 0

0 0

182 SE 1

20 45 90 24 13 5

0 0

0 0

0 198 SSE 1

8 29 87 30 22 12 1

0 0

0 0

190 S

1 8

17 82 53 57 33 1

0 0

0 0

252 SSW 1

4 16 41 72 97 80 8

1 0

0 0

320 SW 0

4 3

31 44 128 142 16 1

0 0

0 369 WSW 0

2 5

8 14 22 124 65 2

0 0

0 242 W

0 3

3 6

5 11 6

0 0

0 0

0 34 WNW 0

2 2

2 7

8 5

0 0

0 0

0 26 NW 0

1 2

5 7

20 11 2

0 0

0 0

48 NNW 0

1 4

10 11 14 10 1

0 0

0 0

51 Totals 31 174 476 1315 1201 1443 608 98 4

0 0

0 5350 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 5350 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-90 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00 -

12/31/03 23:00 Total Period Elevation:Speed:

60M SPD Direction:

60M WD Lapse:

DT60-10 Stability Class G Delta Temperature Extremely Stable Wind Speed (m/s)

Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

0 3

6 29 62 163 42 0

0 0

0 0

305 NNE 1

6 21 169 418 365 39 0

0 0

0 0

1019 NE 3

11 53 226 208 108 12 0

0 0

0 0

621 ENE 0

10 53 105 45 20 3

0 0

0 0

0 236 E

1 8

50 84 10 10 1

0 0

0 0

0 164 ESE 2

14 31 68 19 5

3 0

0 0

0 0

142 SE 0

4 26 66 16 12 1

0 0

0 0

0 125 SSE 1

5 19 47 32 10 1

1 0

0 0

0 116 S

0 3

11 41 47 60 18 2

0 0

0 0

182 SSW 0

1 4

23 31 72 49 6

0 0

0 0

186 SW 0

0 5

16 24 70 48 5

0 0

0 0

168 WSW 0

0 3

4 8

9 25 13 1

0 0

0 63 W

0 0

1 3

1 1

1 0

0 0

0 0

7 WNW 0

0 1

3 0

6 3

0 0

0 0

0 13 NW 1

1 0

4 3

8 6

0 0

0 0

0 23 NNW 0

0 0

4 0

14 7

0 0

0 0

0 25 Totals 9

66 284 892 924 933 259 27 1

0 0

0 3395 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 3395 Total Hours for the Period 43823

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-91 Joint Frequency Distribution Hours at Each Wind Speed and Direction Period of Record = 01/01/99 1:00-12/31/03 23:00 Total Period Elevation: Speed:

60M SPD Direction:

60M WD Lapse:

DT60-10 Summary of All Stability Classes Delta Temperature Wind 0.23 0.51-0.76-1.1-1.6-2.1-3.1-5.1-7.1-10.1-13.1-Direction 0.50 0.75 1.0 1.5 2.0 3.0 5.0 7.0 10.0 13.0 18.0

> 18.0 Total From N

2 28 52 181 299 714 949 453 59 0

0 0

2737 NNE 7

47 153 829 1468 1879 1230 472 75 2

0 0

6162 NE 16 115 380 1154 828 911 890 255 27 1

0 0

4577 ENE 20 118 322 515 290 394 237 47 5

6 0

0 1954 E

21 111 260 388 189 261 247 40 18 2

0 0

1537 ESE 11 115 200 273 145 206 265 75 19 3

3 0

1315 SE 9

77 182 349 167 254 387 148 43 15 0

0 1631 SSE 8

64 161 357 193 304 502 157 52 12 0

0 1810 S

7 51 150 396 307 433 625 306 105 20 1

0 2401 SSW 7

22 101 344 437 686 1007 510 170 7

1 0

3292 SW 2

20 64 280 428 1096 1965 984 227 12 1

0 5079 WSW 0

10 34 83 188 402 1391 1658 905 113 9

0 4793 W

2 11 17 40 59 153 520 571 267 36 5

0 1681 WNW 0

6 8

20 32 165 455 272 108 7

0 0

1073 NW 2

7 11 29 35 163 756 542 104 1

0 0

1650 NNW 1

9 17 51 45 178 733 567 140 2

0 0

1743 Totals 115 811 2112 5289 5110 8199 12159 7057 2324 239 20 0

43435 Number of Calm Hours for this Table 3

Number of Variable Direction Hours for this Table 0

Number of Invalid Hours 385 Number of Valid Hours for this Table 43435 Total Hours for the Period 43823

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 Table 2.3-92

SUMMARY

OF SHORT-TERM X/Q (SEC/M3) RESULTS AT 549 METER EAB Period of Record Data Source 1-hour 5%

Direction Independent 1-hour 5%

Direction Dependent 1-hour 5%

Direction Independent 1999 SSES Tower 6.5E-4 8.4E-4 1.2E-4 2000 SSES Tower 6.5E-4 8.2E-4 1.3E-4 2001 SSES Tower 6.6E-4 8.3E-4 1.4E-4 2002 SSES Tower 6.6E-4 8.4E-4 1.2E-4 2003 SSES Tower 4.9E-4 7.9E-4 1.2E-4 5-Year Combined SSES Tower 6.5E-4 8.3E-4 1.3E-4

SSES - FSAR Table Rev 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 3.50E-09 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 1.00E-08 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 2.50E-08 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 7.00E-08 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 1.00E-07 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 1.50E-07 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 2.20E-07 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 3.20E-07 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 4.80E-07 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 7.00E-07 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 1.00E-06 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 1.50E-06 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 2.00E-06 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 3.00E-06 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.0626 0.0313 0.0177 0.0306 0.0393 4.00E-06 0.0616 0.0747 0.0962 0.1615 0.0758 0.0447 0.0445 0.0366 0.0519 0.0665 0.1017 0.0611 0.0307 0.0177 0.0306 0.0393 5.00E-06 0.0616 0.0739 0.096 0.1615 0.0758 0.0446 0.0444 0.0366 0.0518 0.0663 0.0997 0.0572 0.0289 0.0169 0.0304 0.0393 7.00E-06 0.0604 0.0725 0.0947 0.1612 0.0758 0.0446 0.0436 0.036 0.0502 0.063 0.092 0.055 0.0272 0.0166 0.0304 0.0391 8.50E-06 0.0604 0.0719 0.0937 0.1611 0.0757 0.0444 0.0422 0.0358 0.049 0.0614 0.0905 0.0547 0.0272 0.0166 0.0304 0.039 1.00E-05 0.0602 0.0717 0.0935 0.1608 0.0755 0.0444 0.0416 0.0349 0.0481 0.0609 0.0889 0.054 0.0272 0.0166 0.0303 0.039 1.50E-05 0.0596 0.0708 0.0921 0.1601 0.0751 0.0438 0.0414 0.0347 0.0475 0.0602 0.0861 0.0529 0.0263 0.0164 0.03 0.0389 2.00E-05 0.0592 0.0695 0.0916 0.16 0.0743 0.0433 0.0411 0.0347 0.0469 0.0594 0.0836 0.0501 0.0258 0.0159 0.0298 0.0386 2.50E-05 0.0584 0.0688 0.0901 0.1599 0.0741 0.0429 0.0407 0.0344 0.0459 0.0587 0.082 0.049 0.0251 0.0157 0.0297 0.0382 3.00E-05 0.0573 0.0673 0.089 0.1594 0.074 0.0424 0.0404 0.0337 0.0456 0.0579 0.0807 0.0469 0.0237 0.0157 0.0292 0.0381 3.50E-05 0.0571 0.0662 0.0886 0.1592 0.0739 0.0422 0.0403 0.0337 0.0455 0.0575 0.0795 0.0456 0.0233 0.0155 0.029 0.0373 4.00E-05 0.0564 0.0655 0.0882 0.1587 0.0737 0.0421 0.0392 0.0336 0.0453 0.0565 0.078 0.0417 0.0225 0.015 0.0286 0.0347 5.00E-05 0.051 0.0633 0.0872 0.158 0.0728 0.0419 0.0385 0.0326 0.0446 0.0555 0.0739 0.0333 0.0193 0.0136 0.0257 0.0281 6.00E-05 0.0409 0.0603 0.0861 0.1577 0.0725 0.0417 0.0373 0.0325 0.0442 0.0545 0.0653 0.0255 0.015 0.0112 0.0205 0.0212 7.00E-05 0.0325 0.0555 0.0842 0.1569 0.0721 0.0412 0.0365 0.0308 0.0429 0.0534 0.0581 0.0214 0.0119 0.0088 0.0163 0.0164 8.50E-05 0.0214 0.0432 0.0763 0.1538 0.07 0.0383 0.0336 0.0286 0.0397 0.0467 0.0455 0.0167 0.0084 0.0048 0.0095 0.0099 1.00E-04 0.0153 0.0338 0.0679 0.1506 0.0683 0.0359 0.0314 0.0248 0.0351 0.0398 0.038 0.0119 0.0062 0.0036 0.0067 0.0067 1.30E-04 0.0087 0.0201 0.0534 0.1447 0.0647 0.0337 0.0257 0.0195 0.0267 0.0266 0.0185 0.0056 0.0033 0.0017 0.0021 0.0021 1.70E-04 0.0056 0.0144 0.046 0.1399 0.0612 0.031 0.0225 0.0166 0.0224 0.0183 0.0123 0.003 0.0019 0.0009 0.0011 0.0007 2.00E-04 0.0046 0.0111 0.04 0.1356 0.0571 0.0287 0.02 0.0146 0.0188 0.0125 0.0091 0.0021 0.0015 0.0005 0.0007 0.0006 2.50E-04 0.003 0.0071 0.0299 0.1235 0.0531 0.0257 0.0172 0.0112 0.0111 0.0071 0.0041 0.0009 0.0008 0.0002 0.0003 0.0003 3.00E-04 0.0023 0.0052 0.0237 0.1102 0.0479 0.0234 0.0147 0.0094 0.0081 0.0049 0.003 0.0006 0.0006 0

0.0002 0.0002 3.50E-04 0.0016 0.0034 0.0177 0.0935 0.039 0.0171 0.0103 0.0056 0.0058 0.0022 0.0017 0.0005 0.0003 0

0 0.0002 4.00E-04 0.0009 0.0028 0.0144 0.0784 0.0317 0.0142 0.0081 0.0038 0.0036 0.001 0.0011 0.0002 0.0001 0

0 0.0001 5.00E-04 0.0006 0.0022 0.0106 0.0544 0.0259 0.011 0.0056 0.0019 0.0021 0.0005 0.0006 0.0002 0

0 0

0.0001 6.00E-04 0.0006 0.0017 0.0078 0.0268 0.015 0.008 0.0036 0.0011 0.0009 0.0002 0.0002 0

0 0

0 0.0001 7.00E-04 0.0003 0.0009 0.004 0.0133 0.0078 0.0052 0.0021 0.0007 0.0008 0.0002 0.0001 0

0 0

0 0.0001 8.50E-04 0.0001 0.0005 0.0018 0.0046 0.004 0.0029 0.0013 0.0006 0.0003 0.0001 0

0 0

0 0

0.0001 1.00E-03 0.0001 0.0002 0.001 0.0023 0.0025 0.0015 0.0007 0.0001 0.0002 0.0001 0

0 0

0 0

0 1.40E-03 0

0 0.0001 0.0003 0.0003 0

0 0

0 0

0 0

0 0

0 0

Table 2.3-93 1999 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES EAB Probability that the X/Q is Greater than the Adjacent Quantized Level QUANTIZED LEVEL N

NNE NE SW ENE E

ESE SE NNW DIRECTION WSW W

WNW NW SSE S

SSW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 3.50E-09 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 1.00E-08 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 2.50E-08 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 7.00E-08 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 1.00E-07 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 1.50E-07 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 2.20E-07 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 3.20E-07 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 4.80E-07 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 7.00E-07 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 1.00E-06 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 1.50E-06 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 2.00E-06 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 3.00E-06 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0556 0.0296 0.0235 0.0344 0.0479 4.00E-06 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0438 0.0365 0.0622 0.0669 0.0974 0.0546 0.0295 0.0235 0.0344 0.0479 5.00E-06 0.054 0.0683 0.0977 0.1611 0.0783 0.0403 0.0435 0.0364 0.0618 0.0666 0.095 0.0534 0.029 0.0234 0.0344 0.0479 7.00E-06 0.0535 0.0663 0.0967 0.161 0.0783 0.0402 0.0434 0.0363 0.0597 0.065 0.089 0.053 0.0288 0.0234 0.0342 0.0479 8.50E-06 0.0534 0.0661 0.0961 0.161 0.0782 0.0401 0.0433 0.0358 0.0589 0.064 0.0866 0.0526 0.0288 0.0234 0.0342 0.0478 1.00E-05 0.0531 0.0656 0.0955 0.1607 0.0782 0.0398 0.043 0.0356 0.0581 0.0634 0.0856 0.0519 0.0283 0.0234 0.0342 0.0476 1.50E-05 0.0524 0.0651 0.0944 0.1605 0.0779 0.0394 0.0429 0.0352 0.0574 0.0624 0.0828 0.0499 0.0265 0.0228 0.0339 0.0474 2.00E-05 0.0523 0.064 0.0938 0.16 0.0774 0.0389 0.0427 0.0349 0.0568 0.062 0.0801 0.0485 0.026 0.0226 0.0338 0.0469 2.50E-05 0.0518 0.0634 0.0934 0.1598 0.0773 0.0385 0.0425 0.0347 0.0564 0.061 0.078 0.0475 0.0256 0.0225 0.0338 0.0468 3.00E-05 0.0513 0.0627 0.093 0.1597 0.0771 0.0382 0.0424 0.0345 0.0554 0.0602 0.0766 0.0453 0.0251 0.0223 0.0337 0.0467 3.50E-05 0.0509 0.0623 0.0919 0.1594 0.0771 0.038 0.0422 0.0345 0.0547 0.0589 0.0753 0.0432 0.0244 0.0221 0.0336 0.0465 4.00E-05 0.05 0.0622 0.0912 0.1591 0.0768 0.0377 0.0422 0.0342 0.0546 0.0584 0.0733 0.0393 0.0242 0.021 0.0331 0.0451 5.00E-05 0.0467 0.0615 0.0905 0.1588 0.0767 0.0366 0.0418 0.034 0.0537 0.058 0.0689 0.0315 0.0215 0.0185 0.0303 0.0381 6.00E-05 0.0411 0.0608 0.0897 0.1584 0.0763 0.0362 0.0414 0.0338 0.0527 0.0567 0.0632 0.025 0.0174 0.0158 0.0236 0.0297 7.00E-05 0.0355 0.0588 0.0892 0.1582 0.0758 0.0357 0.041 0.0336 0.0521 0.0561 0.0575 0.0205 0.014 0.0124 0.0168 0.0218 8.50E-05 0.0225 0.049 0.0828 0.1547 0.074 0.0341 0.0394 0.0321 0.0477 0.0513 0.0441 0.0138 0.0079 0.0073 0.0084 0.0112 1.00E-04 0.0175 0.0406 0.0726 0.1514 0.0696 0.0318 0.0361 0.0295 0.043 0.0451 0.0349 0.0097 0.005 0.0042 0.0062 0.0078 1.30E-04 0.0097 0.0297 0.0599 0.1467 0.0651 0.0293 0.0306 0.0248 0.0356 0.0301 0.0177 0.0053 0.0027 0.001 0.0024 0.003 1.70E-04 0.0051 0.0193 0.0495 0.1395 0.0618 0.0269 0.0265 0.021 0.028 0.0207 0.0092 0.0027 0.0016 0.0007 0.0014 0.0018 2.00E-04 0.0039 0.0139 0.0424 0.1317 0.0574 0.0245 0.0224 0.0183 0.0226 0.0144 0.0056 0.0015 0.0009 0.0005 0.0008 0.001 2.50E-04 0.0023 0.009 0.0316 0.1169 0.051 0.0201 0.0183 0.0132 0.0147 0.0086 0.0029 0.0003 0.0007 0.0002 0.0002 0.0005 3.00E-04 0.0011 0.0061 0.0257 0.1024 0.0446 0.0166 0.0152 0.0098 0.0107 0.0057 0.0017 0.0001 0.0006 0.0001 0.0002 0.0002 3.50E-04 0.0007 0.0042 0.0196 0.0813 0.0381 0.014 0.0114 0.0068 0.007 0.003 0.001 0.0001 0.0003 0.0001 0.0001 0.0001 4.00E-04 0.0005 0.003 0.0161 0.0685 0.0311 0.011 0.0091 0.0053 0.0047 0.0023 0.0006 0.0001 0.0003 0.0001 0.0001 0.0001 5.00E-04 0.0002 0.0015 0.0122 0.0438 0.0218 0.0073 0.0058 0.0032 0.0023 0.001 0.0006 0

0.0003 0.0001 0.0001 0

6.00E-04 0.0001 0.0011 0.0079 0.025 0.0148 0.0051 0.0042 0.0017 0.0011 0.0009 0.0002 0

0.0003 0.0001 0

0 7.00E-04 0

0.0008 0.0049 0.013 0.0075 0.0021 0.0025 0.0007 0.0002 0.0006 0

0 0.0001 0.0001 0

0 8.50E-04 0

0.0005 0.0016 0.0031 0.0027 0.001 0.001 0.0001 0.0001 0.0001 0

0 0.0001 0

0 0

1.00E-03 0

0.0002 0.0009 0.0016 0.0014 0.0002 0.0006 0.0001 0

0 0

0 0

0 0

0 1.40E-03 0

0 0.0001 0.0002 0.0001 0

0 0

0 0

0 0

0 0

0 0

2.00E-03 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-94 2000 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES EAB Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

SSES - FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 3.50E-09 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 1.00E-08 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 2.50E-08 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 7.00E-08 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1048 0.0554 0.0296 0.0235 0.0344 0.0479 1.00E-07 0.0508 0.0585 0.0751 0.1698 0.0853 0.0466 0.0506 0.0465 0.0654 0.0669 0.0998 0.0526 0.0284 0.0234 0.0344 0.0478 1.50E-07 0.0485 0.0562 0.0738 0.1697 0.0851 0.0465 0.0496 0.0457 0.0629 0.0645 0.0875 0.0495 0.0264 0.0226 0.0339 0.0476 2.20E-07 0.0482 0.0542 0.0718 0.1685 0.0846 0.0457 0.0473 0.0436 0.0596 0.0591 0.08 0.0485 0.0259 0.0225 0.0338 0.0471 3.20E-07 0.048 0.053 0.0707 0.1672 0.0835 0.0448 0.0455 0.0422 0.0575 0.0569 0.0768 0.0481 0.0258 0.0225 0.0337 0.047 4.80E-07 0.0477 0.0528 0.0698 0.1658 0.0825 0.0442 0.045 0.0417 0.0568 0.0559 0.0756 0.0476 0.0256 0.0225 0.0337 0.0469 7.00E-07 0.0474 0.0524 0.0697 0.1656 0.0818 0.0436 0.045 0.0416 0.0565 0.0558 0.0741 0.0458 0.0251 0.0224 0.0336 0.0467 1.00E-06 0.0454 0.0521 0.0695 0.1656 0.0818 0.0436 0.045 0.0415 0.0561 0.0554 0.0721 0.0445 0.0249 0.0218 0.0334 0.0466 1.50E-06 0.0453 0.052 0.0692 0.1654 0.0815 0.0434 0.0447 0.0415 0.055 0.0545 0.0706 0.042 0.0243 0.0215 0.0333 0.0462 2.00E-06 0.0451 0.0515 0.0688 0.1648 0.0813 0.043 0.0446 0.0413 0.0542 0.054 0.0681 0.0345 0.0229 0.0201 0.0316 0.0418 3.00E-06 0.0322 0.0483 0.0674 0.1633 0.081 0.0429 0.043 0.0404 0.0534 0.0523 0.0545 0.0201 0.0136 0.0116 0.0156 0.0204 4.00E-06 0.02 0.0421 0.0646 0.1624 0.0795 0.0411 0.0394 0.0385 0.0497 0.0485 0.0428 0.0137 0.0072 0.0068 0.008 0.0104 5.00E-06 0.0166 0.0367 0.0622 0.1606 0.0774 0.039 0.0362 0.0348 0.0438 0.0447 0.0374 0.0103 0.005 0.0042 0.0061 0.0078 7.00E-06 0.0129 0.0302 0.0555 0.1564 0.0747 0.0367 0.0324 0.03 0.0386 0.0373 0.0259 0.0058 0.0027 0.0024 0.005 0.0062 8.50E-06 0.0097 0.0243 0.0511 0.1536 0.0721 0.0354 0.0297 0.0264 0.034 0.0307 0.0169 0.0038 0.0019 0.0015 0.0023 0.0029 1.00E-05 0.007 0.0194 0.0473 0.1502 0.07 0.0327 0.0275 0.0241 0.0304 0.0244 0.0133 0.003 0.0017 0.0007 0.0015 0.0019 1.50E-05 0.0032 0.0112 0.0368 0.1387 0.0639 0.0281 0.0217 0.0178 0.0206 0.0118 0.0063 0.0013 0.0008 0.0002 0.0007 0.0008 2.00E-05 0.0018 0.0063 0.0301 0.1264 0.057 0.0238 0.0167 0.0124 0.0129 0.0062 0.0033 0.0002 0.0007 0.0001 0.0002 0.0005 2.50E-05 0.0014 0.0041 0.0243 0.1159 0.0492 0.0198 0.0117 0.0082 0.0086 0.0044 0.0024 0.0002 0.0006 0.0001 0.0002 0.0002 3.00E-05 0.001 0.0028 0.0202 0.1037 0.043 0.0163 0.0093 0.0064 0.0074 0.003 0.0016 0.0001 0.0005 0.0001 0.0002 0.0001 3.50E-05 0.0007 0.0024 0.0162 0.0921 0.0381 0.0132 0.0074 0.0057 0.0062 0.0023 0.0014 0

0.0005 0.0001 0.0001 0

4.00E-05 0.0006 0.0016 0.0139 0.0783 0.0346 0.011 0.0063 0.0044 0.0043 0.0016 0.0011 0

0.0003 0.0001 0

0 5.00E-05 0.0003 0.0011 0.0109 0.0588 0.0284 0.0092 0.0048 0.003 0.0024 0.001 0.0007 0

0.0002 0.0001 0

0 6.00E-05 0.0003 0.0009 0.0077 0.0393 0.0201 0.0067 0.0028 0.0017 0.0014 0.0009 0.0005 0

0.0002 0.0001 0

0 7.00E-05 0.0001 0.0008 0.0051 0.0248 0.0133 0.0046 0.0021 0.0014 0.0008 0.0005 0.0003 0

0.0001 0.0001 0

0 8.50E-05 0.0001 0.0002 0.0029 0.0107 0.0072 0.0018 0.0013 0.0003 0.0001 0.0001 0.0003 0

0.0001 0

0 0

1.00E-04 0.0001 0.0002 0.0016 0.0037 0.0034 0.0017 0.0011 0.0002 0

0 0.0001 0

0 0

0 0

1.30E-04 0

0.0001 0.0001 0.0002 0.0002 0.0001 0.0003 0

0 0

0 0

0 0

0 0

1.70E-04 0

0 0

0.0001 0

0 0

0 0

0 0

0 0

0 0

0 2.00E-04 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-95 2001 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES EAB Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 3.50E-09 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 1.00E-08 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 2.50E-08 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 7.00E-08 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 1.00E-07 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 1.50E-07 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 2.20E-07 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 3.20E-07 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 4.80E-07 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 7.00E-07 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 1.00E-06 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 1.50E-06 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 2.00E-06 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 3.00E-06 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1142 0.0627 0.0314 0.0204 0.0296 0.0398 4.00E-06 0.0491 0.0718 0.0827 0.1446 0.0676 0.0451 0.0424 0.0462 0.0672 0.0821 0.1114 0.061 0.0314 0.0204 0.0295 0.0395 5.00E-06 0.0477 0.0707 0.0827 0.1446 0.0676 0.0447 0.042 0.0458 0.0661 0.0803 0.1064 0.059 0.031 0.0204 0.0295 0.0392 7.00E-06 0.0466 0.0699 0.0823 0.1446 0.0674 0.0447 0.0418 0.0456 0.0655 0.0768 0.1001 0.058 0.0309 0.0204 0.0295 0.039 8.50E-06 0.0465 0.0694 0.0816 0.1446 0.0674 0.0446 0.0418 0.0455 0.0655 0.0756 0.0981 0.0575 0.0309 0.0204 0.0295 0.0388 1.00E-05 0.0463 0.0693 0.0813 0.1443 0.0674 0.0446 0.0418 0.0454 0.0649 0.0752 0.0964 0.0568 0.0307 0.0204 0.0295 0.0386 1.50E-05 0.0451 0.0685 0.0805 0.1437 0.0672 0.0443 0.0417 0.0451 0.0639 0.0741 0.0903 0.0538 0.0303 0.0201 0.0292 0.0378 2.00E-05 0.0441 0.0677 0.0802 0.1436 0.0669 0.0443 0.0414 0.0451 0.0634 0.0727 0.0848 0.0514 0.0299 0.0201 0.029 0.0373 2.50E-05 0.0438 0.0669 0.08 0.1435 0.0667 0.0443 0.0414 0.0447 0.0625 0.0712 0.0825 0.0504 0.0297 0.0201 0.0289 0.0369 3.00E-05 0.0429 0.0663 0.0794 0.1435 0.0666 0.0443 0.041 0.0447 0.0622 0.0707 0.0808 0.0496 0.0287 0.0201 0.0288 0.0365 3.50E-05 0.0427 0.0661 0.0793 0.1433 0.0665 0.044 0.041 0.0443 0.0618 0.07 0.0793 0.0478 0.0277 0.0194 0.0285 0.0362 4.00E-05 0.0423 0.0652 0.0792 0.1432 0.0663 0.0439 0.0408 0.044 0.0612 0.0696 0.0775 0.0451 0.0266 0.0186 0.0277 0.0348 5.00E-05 0.0418 0.0644 0.0786 0.1431 0.0659 0.0433 0.0406 0.0437 0.0604 0.0688 0.0719 0.0372 0.0218 0.0146 0.0234 0.0295 6.00E-05 0.0384 0.0635 0.0782 0.1429 0.0657 0.043 0.04 0.0431 0.0583 0.0676 0.0641 0.0295 0.0173 0.0118 0.0181 0.0235 7.00E-05 0.0338 0.0614 0.0772 0.1428 0.0655 0.0423 0.0388 0.0415 0.0554 0.0651 0.0572 0.0237 0.0148 0.0092 0.0135 0.0184 8.50E-05 0.022 0.0513 0.0716 0.1416 0.064 0.0402 0.0353 0.0362 0.0514 0.0582 0.0414 0.0171 0.0099 0.0047 0.0067 0.0092 1.00E-04 0.0171 0.0432 0.0632 0.1386 0.0618 0.0371 0.0309 0.032 0.0448 0.0482 0.0311 0.0124 0.0061 0.0033 0.0047 0.0074 1.30E-04 0.0091 0.0261 0.0549 0.1349 0.0584 0.0338 0.0258 0.0259 0.0331 0.0288 0.0136 0.0055 0.0029 0.0016 0.0021 0.0033 1.70E-04 0.0054 0.0175 0.0459 0.1306 0.0545 0.0308 0.0224 0.0205 0.0252 0.0165 0.0066 0.0027 0.0018 0.001 0.0009 0.0018 2.00E-04 0.0032 0.0134 0.0399 0.1268 0.052 0.028 0.0194 0.0176 0.0196 0.0114 0.0043 0.0014 0.0014 0.0006 0.0006 0.0015 2.50E-04 0.0022 0.0089 0.032 0.1183 0.0473 0.024 0.0152 0.0127 0.0122 0.007 0.0021 0.0008 0.0005 0.0005 0.0001 0.0007 3.00E-04 0.0016 0.0067 0.0277 0.1093 0.0415 0.0219 0.012 0.0106 0.0082 0.0045 0.0015 0.0003 0

0.0003 0.0001 0.0002 3.50E-04 0.0009 0.005 0.0213 0.0929 0.035 0.0168 0.0093 0.0078 0.0055 0.0028 0.0008 0.0002 0

0.0003 0.0001 0.0002 4.00E-04 0.0007 0.0037 0.0179 0.0801 0.0308 0.0142 0.0074 0.0061 0.0035 0.0017 0.0006 0.0002 0

0.0001 0.0001 0.0002 5.00E-04 0.0005 0.0029 0.0119 0.0568 0.0233 0.0108 0.0046 0.0038 0.0015 0.0007 0.0003 0.0001 0

0 0

0.0001 6.00E-04 0.0003 0.0018 0.0071 0.0329 0.0146 0.0073 0.0031 0.0016 0.0008 0.0005 0.0003 0.0001 0

0 0

0 7.00E-04 0.0002 0.0012 0.0032 0.0145 0.0073 0.0038 0.0017 0.0014 0.0002 0.0001 0.0001 0.0001 0

0 0

0 8.50E-04 0.0001 0.0005 0.0015 0.0041 0.0022 0.0016 0.0006 0.0003 0.0001 0.0001 0.0001 0.0001 0

0 0

0 1.00E-03 0.0001 0.0005 0.0008 0.0014 0.0009 0.0007 0.0003 0.0001 0

0 0

0.0001 0

0 0

0 1.40E-03 0

0 0

0 0.0001 0.0001 0

0 0

0 0

0 0

0 0

0 2.00E-03 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 3.00E-03 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-96 2002 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES EAB Probability that the X/Q is Greater than the Adjacent Quantized Level QUANTIZED LEVEL N

NNE NE SW ENE E

ESE SE NNW DIRECTION WSW W

WNW NW SSE S

SSW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 3.50E-09 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 1.00E-08 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 2.50E-08 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 7.00E-08 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 1.00E-07 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 1.50E-07 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 2.20E-07 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 3.20E-07 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 4.80E-07 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 7.00E-07 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 1.00E-06 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 1.50E-06 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 2.00E-06 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 3.00E-06 0.0391 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1002 0.0619 0.0297 0.0214 0.0287 0.0348 4.00E-06 0.039 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0682 0.0974 0.0605 0.0293 0.0213 0.0282 0.034 5.00E-06 0.0384 0.0764 0.1089 0.1414 0.0673 0.0497 0.0612 0.0468 0.0599 0.0674 0.096 0.0592 0.0289 0.021 0.0277 0.0333 7.00E-06 0.038 0.075 0.1082 0.1413 0.0672 0.0496 0.0609 0.0464 0.0584 0.0656 0.0924 0.0575 0.0286 0.0205 0.0277 0.0331 8.50E-06 0.038 0.075 0.1081 0.1412 0.0671 0.0494 0.0609 0.046 0.058 0.0644 0.0908 0.0565 0.0285 0.0203 0.0277 0.0326 1.00E-05 0.038 0.0749 0.1078 0.1411 0.067 0.0493 0.0606 0.0455 0.0573 0.0629 0.0894 0.0559 0.0282 0.0202 0.0277 0.0325 1.50E-05 0.0376 0.0746 0.1073 0.1408 0.0665 0.0491 0.0605 0.045 0.0566 0.0614 0.0867 0.0538 0.0277 0.0195 0.0273 0.032 2.00E-05 0.0372 0.0742 0.1072 0.1406 0.0657 0.049 0.0601 0.0446 0.056 0.0605 0.0847 0.0524 0.0271 0.0194 0.0273 0.0319 2.50E-05 0.037 0.0741 0.1066 0.1406 0.0655 0.0489 0.0601 0.044 0.056 0.0605 0.0838 0.0523 0.0267 0.0191 0.027 0.0316 3.00E-05 0.0365 0.0739 0.1062 0.1405 0.0654 0.0489 0.0597 0.0439 0.0559 0.0601 0.0829 0.0503 0.0257 0.0188 0.0263 0.0314 3.50E-05 0.0364 0.0738 0.1062 0.1404 0.0652 0.0488 0.0594 0.0436 0.0559 0.0597 0.0816 0.0488 0.0254 0.0174 0.026 0.0314 4.00E-05 0.0362 0.0728 0.1059 0.1398 0.0651 0.0486 0.059 0.0435 0.0558 0.0595 0.0805 0.0453 0.024 0.0164 0.0252 0.0307 5.00E-05 0.0348 0.0719 0.1057 0.1395 0.0648 0.0481 0.0584 0.0431 0.0557 0.0591 0.0751 0.0378 0.021 0.0148 0.0216 0.026 6.00E-05 0.0319 0.071 0.105 0.1389 0.0643 0.0473 0.0568 0.0422 0.0549 0.0581 0.0664 0.0312 0.0165 0.0111 0.0164 0.0195 7.00E-05 0.0289 0.0679 0.103 0.1381 0.0634 0.0464 0.0552 0.0413 0.0529 0.0566 0.0566 0.0258 0.013 0.0099 0.0126 0.0145 8.50E-05 0.0201 0.0561 0.0936 0.1357 0.0617 0.0424 0.0485 0.038 0.0483 0.05 0.0379 0.0179 0.0093 0.0071 0.0076 0.0089 1.00E-04 0.0154 0.0493 0.0858 0.1321 0.0602 0.0393 0.042 0.0338 0.0438 0.043 0.0267 0.0129 0.0063 0.0047 0.0054 0.007 1.30E-04 0.0075 0.032 0.0723 0.1269 0.0561 0.034 0.0362 0.0265 0.0317 0.0258 0.0121 0.006 0.0027 0.002 0.0021 0.0023 1.70E-04 0.0041 0.0217 0.0619 0.1229 0.0528 0.0302 0.03 0.0209 0.0243 0.0158 0.006 0.0029 0.0016 0.0009 0.0013 0.0014 2.00E-04 0.003 0.0151 0.0535 0.1168 0.0499 0.0271 0.0252 0.0176 0.0184 0.0112 0.0041 0.0017 0.0013 0.0007 0.0008 0.0009 2.50E-04 0.0015 0.0084 0.0385 0.1037 0.0441 0.0216 0.0195 0.0123 0.01 0.0054 0.0017 0.0009 0.0006 0.0003 0.0005 0.0006 3.00E-04 0.001 0.0045 0.0318 0.0927 0.0368 0.0173 0.0156 0.0083 0.0067 0.0038 0.0006 0.0005 0.0006 0.0001 0.0002 0.0005 3.50E-04 0.0008 0.0027 0.0243 0.0732 0.0297 0.0128 0.0114 0.0052 0.0038 0.0015 0.0003 0.0002 0.0005 0

0.0001 0.0002 4.00E-04 0.0005 0.0021 0.0212 0.0622 0.0258 0.0113 0.0078 0.0038 0.0027 0.001 0.0002 0.0002 0.0005 0

0.0001 0.0001 5.00E-04 0.0002 0.0013 0.0142 0.0411 0.0183 0.0068 0.0045 0.0014 0.0013 0.0008 0

0.0001 0.0005 0

0.0001 0

6.00E-04 0.0001 0.001 0.0093 0.0225 0.0115 0.0035 0.0031 0.0009 0.0008 0.0003 0

0 0.0003 0

0 0

7.00E-04 0

0.0007 0.0051 0.0093 0.0055 0.0018 0.0017 0.0006 0.0002 0

0 0

0.0001 0

0 0

8.50E-04 0

0.0002 0.0012 0.0023 0.0024 0.0008 0.0003 0.0002 0

0 0

0 0.0001 0

0 0

1.00E-03 0

0.0001 0.0003 0.0008 0.0006 0.0003 0.0002 0.0001 0

0 0

0 0.0001 0

0 0

1.40E-03 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 2.00E-03 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-97 2003 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES EAB Probability that the X/Q is Greater than the Adjacent Quantized Level QUANTIZED LEVEL N

NNE NE SW ENE E

ESE SE NNW DIRECTION WSW W

WNW NW SSE S

SSW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-98 1999 - 2003 Probability Values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES EAB Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 1.00E-10 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 3.50E-09 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 1.00E-08 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 2.50E-08 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 7.00E-08 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 1.00E-07 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 1.50E-07 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0419 2.20E-07 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0418 3.20E-07 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0418 4.80E-07 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0418 7.00E-07 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0417 1.00E-06 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0417 1.50-E-06 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0416 2.00E-06 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1042 0.0599 0.0303 0.0213 0.0315 0.0406 3.00E-06 0.0513 0.0705 0.0923 0.1558 0.0749 0.0453 0.0487 0.0426 0.0618 0.0704 0.1040 0.0597 0.0303 0.0213 0.0315 0.0364 4.00E-06 0.0510 0.0702 0.0923 0.1557 0.0749 0.0453 0.0487 0.0426 0.0616 0.0702 0.1022 0.0584 0.0301 0.0213 0.0314 0.0342 5.00E-06 0.0505 0.0695 0.0921 0.1557 0.0749 0.0452 0.0483 0.0424 0.0610 0.0695 0.0992 0.0564 0.0294 0.0210 0.0313 0.0335 7.00E-06 0.0499 0.0682 0.0912 0.1556 0.0748 0.0451 0.0479 0.0420 0.0594 0.0670 0.0929 0.0553 0.0289 0.0209 0.0312 0.0331 8.50E-06 0.0498 0.0678 0.0905 0.1555 0.0747 0.0450 0.0473 0.0416 0.0586 0.0655 0.0906 0.0548 0.0288 0.0208 0.0312 0.0322 1.00E-05 0.0497 0.0676 0.0901 0.1551 0.0747 0.0448 0.0470 0.0411 0.0578 0.0646 0.0891 0.0541 0.0285 0.0208 0.0312 0.0318 1.50E-05 0.0486 0.0669 0.0893 0.1546 0.0742 0.0444 0.0467 0.0407 0.0570 0.0634 0.0857 0.0521 0.0275 0.0203 0.0309 0.0314 2.00E-05 0.0482 0.0660 0.0888 0.1544 0.0736 0.0440 0.0463 0.0404 0.0564 0.0626 0.0826 0.0502 0.0270 0.0201 0.0307 0.0310 2.50E-05 0.0478 0.0654 0.0863 0.1543 0.0734 0.0438 0.0461 0.0401 0.0559 0.0618 0.0809 0.0493 0.0265 0.0200 0.0306 0.0307 3.00E-05 0.0470 0.0646 0.0876 0.1541 0.0732 0.0436 0.0458 0.0399 0.0554 0.0612 0.0794 0.0475 0.0257 0.0198 0.0303 0.0306 3.50E-05 0.0468 0.0642 0.0873 0.1539 0.0731 0.0434 0.0456 0.0396 0.0550 0.0606 0.0779 0.0457 0.0250 0.0193 0.0301 0.0303 4.00E-05 0.0462 0.0636 0.0869 0.1535 0.0730 0.0432 0.0452 0.0394 0.0547 0.0600 0.0763 0.0421 0.0243 0.0184 0.0295 0.0291 5.00E-05 0.0438 0.0626 0.0862 0.1531 0.0726 0.0427 0.0448 0.0389 0.0540 0.0593 0.0716 0.0343 0.0210 0.0160 0.0263 0.0243 6.00E-05 0.0384 0.0614 0.0855 0.1527 0.0721 0.0423 0.0440 0.0384 0.0529 0.0582 0.0642 0.0272 0.0167 0.0131 0.0204 0.0188 7.00E-05 0.0329 0.0585 0.0843 0.1521 0.0717 0.0417 0.0430 0.0375 0.0514 0.0568 0.0570 0.0224 0.0135 0.0105 0.0152 0.0142 8.50E-05 0.0213 0.0485 0.0778 0.1498 0.0699 0.0393 0.0394 0.0347 0.0474 0.0511 0.0425 0.0159 0.0087 0.0062 0.0081 0.0078 1.00E-04 0.0163 0.0406 0.0703 0.1467 0.0675 0.0366 0.0353 0.0310 0.0421 0.0441 0.0334 0.0113 0.0057 0.0040 0.0058 0.0058 1.30E-04 0.0088 0.0268 0.0589 0.1419 0.0637 0.0333 0.0299 0.0253 0.0326 0.0285 0.0160 0.0055 0.0029 0.0015 0.0022 0.0021 1.70E-04 0.0052 0.0181 0.0503 0.1369 0.0603 0.0307 0.0259 0.0205 0.0258 0.0183 0.0090 0.0028 0.0017 0.0008 0.0012 0.0011 2.00E-04 0.0038 0.0132 0.0433 0.1310 0.0571 0.0280 0.0224 0.0177 0.0207 0.0128 0.0061 0.0016 0.0012 0.0006 0.0007 0.0008 2.50E-04 0.0022 0.0080 0.0328 0.1185 0.0515 0.0237 0.0182 0.0129 0.0129 0.0072 0.0030 0.0006 0.0007 0.0003 0.0003 0.0004 3.00E-04 0.0015 0.0054 0.0270 0.1058 0.0454 0.0205 0.0147 0.0099 0.0090 0.0047 0.0017 0.0003 0.0005 0.0001 0.0002 0.0002 3.50E-04 0.0010 0.0036 0.0204 0.0873 0.0378 0.0161 0.0108 0.0068 0.0059 0.0025 0.0011 0.0002 0.0003 0.0001 0.0001 0.0002 4.00E-04 0.0007 0.0027 0.0170 0.0738 0.0318 0.0134 0.0083 0.0050 0.0040 0.0016 0.0007 0.0002 0.0002 0.0001 0.0001 0.0001 5.00E-04 0.0004 0.0019 0.0118 0.0469 0.0236 0.0093 0.0052 0.0028 0.0019 0.0008 0.0004 0.0001 0.0002 0.0000 0.0001 0.0001 6.00E-04 0.0003 0.0013 0.0077 0.0273 0.0149 0.0062 0.0034 0.0014 0.0010 0.0005 0.0002 0.0000 0.0002 0.0000 0.0000 0.0000 7.00E-04 0.0001 0.0008 0.0042 0.0128 0.0076 0.0032 0.0019 0.0009 0.0003 0.0002 0.0001 0.0000 0.0001 0.0000 0.0000 0.0000 8.50E-04 0.0001 0.0004 0.0015 0.0036 0.0030 0.0016 0.0009 0.0003 0.0001 0.0001 0.0000 0.0000 0.0001 0.0000 0.0000 0.0000 1.00E-03 0.0001 0.0002 0.0007 0.0015 0.0013 0.0007 0.0005 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.40E-03 0.0000 0.0000 0.0000 0.0001 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.00E-03 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 3.50E-09 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 1.00E-08 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 2.50E-08 0.0616 0.0757 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1023 0.063 0.0313 0.0177 0.0306 0.0393 7.00E-08 0.0616 0.0756 0.0964 0.1616 0.0759 0.0447 0.0445 0.0366 0.0521 0.0667 0.1022 0.0623 0.0313 0.0177 0.0306 0.0393 1.00E-07 0.0616 0.0736 0.096 0.1615 0.0758 0.0447 0.0444 0.0366 0.0518 0.0663 0.0997 0.0567 0.029 0.0169 0.0304 0.0393 1.50E-07 0.0597 0.0709 0.0936 0.1611 0.0757 0.0446 0.0436 0.036 0.0498 0.0625 0.0889 0.0528 0.026 0.0161 0.0302 0.0389 2.20E-07 0.0588 0.0688 0.0908 0.1603 0.0751 0.044 0.0412 0.0344 0.0464 0.0594 0.0836 0.051 0.0258 0.0158 0.0297 0.0385 3.20E-07 0.0587 0.0681 0.0892 0.1593 0.0748 0.0431 0.0406 0.0337 0.0458 0.0576 0.0819 0.0507 0.0257 0.0158 0.0297 0.0383 4.80E-07 0.0587 0.0679 0.0891 0.1584 0.0733 0.0424 0.0399 0.0336 0.0455 0.0571 0.0815 0.0497 0.0257 0.0158 0.0297 0.0383 7.00E-07 0.0577 0.067 0.0889 0.1584 0.0731 0.0423 0.0396 0.0335 0.0454 0.0571 0.0807 0.0472 0.0245 0.0157 0.0294 0.038 1.00E-06 0.0568 0.0653 0.0881 0.1583 0.0729 0.0422 0.0396 0.0333 0.0453 0.0564 0.0787 0.0461 0.0236 0.0149 0.0289 0.037 1.50E-06 0.0564 0.0642 0.0873 0.1578 0.0727 0.0419 0.0392 0.0329 0.0443 0.0548 0.0768 0.0445 0.0231 0.0148 0.0288 0.0366 2.00E-06 0.0539 0.0639 0.0872 0.1573 0.0725 0.0414 0.0377 0.0319 0.0435 0.0542 0.074 0.0367 0.0205 0.0142 0.0279 0.0313 3.00E-06 0.0312 0.0546 0.0837 0.1563 0.0717 0.0405 0.0357 0.0303 0.0425 0.0521 0.0567 0.0204 0.0114 0.0086 0.0156 0.0159 4.00E-06 0.0201 0.0423 0.0742 0.1529 0.0695 0.037 0.0331 0.0281 0.0393 0.0458 0.0451 0.0165 0.0079 0.0045 0.0091 0.0088 5.00E-06 0.0155 0.0351 0.0683 0.1503 0.0681 0.0354 0.0314 0.0255 0.0351 0.0399 0.0391 0.0125 0.0062 0.0037 0.0068 0.0067 7.00E-06 0.0122 0.0281 0.0595 0.1451 0.0646 0.0333 0.0264 0.0202 0.0304 0.0336 0.0281 0.0083 0.0047 0.0026 0.005 0.0048 8.50E-06 0.0091 0.0213 0.0537 0.1429 0.0624 0.0317 0.0237 0.0189 0.0268 0.0273 0.019 0.0056 0.0032 0.0017 0.0033 0.0021 1.00E-05 0.0069 0.0177 0.0502 0.1407 0.0592 0.0295 0.0214 0.0163 0.0226 0.0222 0.015 0.0041 0.0021 0.0009 0.0016 0.0011 1.50E-05 0.0038 0.0095 0.0372 0.1321 0.0541 0.0268 0.0183 0.0132 0.0164 0.01 0.0073 0.0018 0.0014 0.0005 0.0007 0.0006 2.00E-05 0.0029 0.006 0.0272 0.1211 0.049 0.0232 0.0147 0.0095 0.0088 0.0061 0.0042 0.001 0.0007 0.0003 0.0003 0.0003 2.50E-05 0.0021 0.0048 0.0231 0.1118 0.0419 0.0169 0.0109 0.006 0.0072 0.0039 0.0031 0.0008 0.0006 0.0001 0

0.0002 3.00E-05 0.0014 0.004 0.0198 0.1021 0.0373 0.0141 0.0093 0.0047 0.0058 0.0029 0.0023 0.0006 0.0003 0

0 0.0001 3.50E-05 0.0013 0.0032 0.0169 0.0923 0.0339 0.0125 0.0073 0.0041 0.0045 0.0021 0.0016 0.0005 0.0002 0

0 0.0001 4.00E-05 0.0009 0.0028 0.0139 0.0812 0.0299 0.0118 0.0063 0.0031 0.003 0.0009 0.0009 0.0002 0.0001 0

0 0.0001 5.00E-05 0.0005 0.0023 0.0111 0.064 0.026 0.0104 0.0056 0.0021 0.0019 0.0005 0.0006 0.0002 0

0 0

0.0001 6.00E-05 0.0005 0.0019 0.0083 0.0394 0.0167 0.0078 0.0033 0.001 0.001 0.0002 0.0002 0

0 0

0 0.0001 7.00E-05 0.0003 0.0013 0.0068 0.0241 0.0111 0.006 0.0026 0.0008 0.0009 0.0002 0.0002 0

0 0

0 0.0001 8.50E-05 0.0002 0.0008 0.0033 0.0108 0.0067 0.0041 0.0016 0.0007 0.0003 0.0001 0

0 0

0 0

0.0001 1.00E-04 0.0001 0.0005 0.0018 0.0046 0.004 0.0029 0.001 0.0006 0.0003 0.0001 0

0 0

0 0

0.0001 1.30E-04 0.0001 0

0.0003 0.0008 0.001 0.0003 0.0003 0.0001 0.0002 0.0001 0

0 0

0 0

0 1.70E-04 0

0 0.0001 0.0001 0.0001 0

0 0

0 0

0 0

0 0

0 0

2.00E-04 0

0 0.0001 0.0001 0.0001 0

0 0

0 0

0 0

0 0

0 0

2.50E-04 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-99 1999 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES LPZ Probability that the X/Q is Greater than the Adjacent Quantized Level E

ESE SE SSE N

NNE NE ENE DIRECTION W

WNW NW NNW S

SSW SW WSW QUANTIZED LEVEL

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 3.50E-09 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 1.00E-08 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 2.50E-08 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0623 0.0669 0.0986 0.0558 0.0296 0.0235 0.0344 0.0479 7.00E-08 0.0542 0.0685 0.0978 0.1613 0.0783 0.0403 0.0439 0.0365 0.0622 0.0669 0.0985 0.0554 0.0296 0.0235 0.0344 0.0479 1.00E-07 0.0538 0.0682 0.0978 0.1612 0.0783 0.0403 0.0435 0.0364 0.062 0.0663 0.0951 0.0526 0.0284 0.0234 0.0344 0.0478 1.50E-07 0.0525 0.0659 0.0967 0.1607 0.0783 0.0402 0.0432 0.036 0.0594 0.0644 0.0854 0.0495 0.0264 0.0226 0.0339 0.0476 2.20E-07 0.0522 0.0637 0.0942 0.1604 0.0779 0.0393 0.0427 0.0349 0.0571 0.0619 0.0795 0.0485 0.0259 0.0225 0.0338 0.0471 3.20E-07 0.0515 0.0628 0.092 0.1595 0.0775 0.0385 0.0426 0.0346 0.0551 0.059 0.0773 0.0481 0.0258 0.0225 0.0337 0.047 4.80E-07 0.0514 0.0626 0.0916 0.159 0.0767 0.0374 0.0424 0.0345 0.0547 0.0586 0.0771 0.0476 0.0256 0.0225 0.0337 0.0469 7.00E-07 0.0509 0.0623 0.0916 0.1589 0.0764 0.0371 0.0422 0.0344 0.0545 0.0586 0.0764 0.0458 0.0251 0.0224 0.0336 0.0467 1.00E-06 0.0506 0.062 0.0909 0.1588 0.0764 0.0371 0.0421 0.0342 0.0542 0.0583 0.074 0.0445 0.0249 0.0218 0.0334 0.0466 1.50E-06 0.0506 0.0614 0.0896 0.1584 0.0763 0.0368 0.042 0.0339 0.0533 0.0567 0.0713 0.042 0.0243 0.0215 0.0333 0.0462 2.00E-06 0.0491 0.0611 0.0894 0.1582 0.076 0.0364 0.042 0.0337 0.0527 0.0566 0.0691 0.0345 0.0229 0.0201 0.0316 0.0418 3.00E-06 0.0344 0.0583 0.0884 0.1578 0.0755 0.0354 0.0409 0.0332 0.0514 0.0559 0.0564 0.0201 0.0136 0.0116 0.0156 0.0204 4.00E-06 0.0217 0.0476 0.0803 0.1541 0.0734 0.0334 0.0387 0.0318 0.0475 0.051 0.0434 0.0137 0.0072 0.0068 0.008 0.0104 5.00E-06 0.0174 0.0408 0.0726 0.1513 0.0694 0.0317 0.036 0.0298 0.0435 0.046 0.0357 0.0103 0.005 0.0042 0.0061 0.0078 7.00E-06 0.0122 0.0322 0.0621 0.1465 0.0647 0.029 0.0309 0.0244 0.0374 0.0368 0.0247 0.0058 0.0027 0.0024 0.005 0.0062 8.50E-06 0.0091 0.0261 0.0547 0.1425 0.0622 0.0274 0.0276 0.0219 0.0338 0.0301 0.0152 0.0038 0.0019 0.0015 0.0023 0.0029 1.00E-05 0.0072 0.0224 0.0505 0.1384 0.0584 0.0253 0.0239 0.0205 0.0309 0.0241 0.0112 0.003 0.0017 0.0007 0.0015 0.0019 1.50E-05 0.0029 0.0122 0.0377 0.1264 0.0517 0.0194 0.0184 0.0153 0.0204 0.0128 0.004 0.0013 0.0008 0.0002 0.0007 0.0008 2.00E-05 0.0022 0.0075 0.0282 0.1123 0.0454 0.0164 0.015 0.0102 0.012 0.0076 0.0029 0.0002 0.0007 0.0001 0.0002 0.0005 2.50E-05 0.0014 0.0058 0.0226 0.1022 0.0394 0.0132 0.0112 0.0068 0.0087 0.0053 0.0017 0.0002 0.0006 0.0001 0.0002 0.0002 3.00E-05 0.0008 0.0042 0.0202 0.0927 0.035 0.011 0.0095 0.0057 0.0073 0.0038 0.001 0.0001 0.0005 0.0001 0.0002 0.0001 3.50E-05 0.0006 0.0034 0.0182 0.0793 0.0314 0.0088 0.0075 0.0048 0.0056 0.0023 0.0008 0

0.0005 0.0001 0.0001 0

4.00E-05 0.0003 0.0027 0.0156 0.068 0.0273 0.0081 0.0063 0.0038 0.0035 0.0019 0.0006 0

0.0003 0.0001 0

0 5.00E-05 0.0003 0.0015 0.0126 0.0519 0.0216 0.0068 0.0051 0.0029 0.0023 0.001 0.0006 0

0.0002 0.0001 0

0 6.00E-05 0.0001 0.0014 0.0089 0.0329 0.016 0.0046 0.004 0.0017 0.0011 0.0009 0.0002 0

0.0002 0.0001 0

0 7.00E-05 0

0.0011 0.0066 0.0217 0.0105 0.0032 0.0027 0.001 0.0008 0.0006 0

0 0.0001 0.0001 0

0 8.50E-05 0

0.0006 0.0035 0.009 0.0055 0.0016 0.0018 0.0002 0.0001 0.0005 0

0 0.0001 0

0 0

1.00E-04 0

0.0005 0.0015 0.0027 0.0024 0.001 0.0008 0.0001 0.0001 0.0001 0

0 0

0 0

0 1.30E-04 0

0 0.0001 0.0002 0.0006 0

0.0003 0

0 0

0 0

0 0

0 0

1.70E-04 0

0 0

0 0.0001 0

0 0

0 0

0 0

0 0

0 0

2.00E-04 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-100 2000 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES LPZ Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 3.50E-09 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 1.00E-08 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 2.50E-08 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1049 0.0558 0.0296 0.0235 0.0344 0.0479 7.00E-08 0.0515 0.0592 0.0751 0.1698 0.0853 0.0466 0.0507 0.0465 0.0659 0.0674 0.1048 0.0554 0.0296 0.0235 0.0344 0.0479 1.00E-07 0.0508 0.0585 0.0751 0.1698 0.0853 0.0466 0.0506 0.0465 0.0654 0.0669 0.0998 0.0526 0.0284 0.0234 0.0344 0.0478 1.50E-07 0.0485 0.0562 0.0738 0.1697 0.0851 0.0465 0.0496 0.0457 0.0629 0.0645 0.0875 0.0495 0.0264 0.0226 0.0339 0.0476 2.20E-07 0.0482 0.0542 0.0718 0.1685 0.0846 0.0457 0.0473 0.0436 0.0596 0.0591 0.08 0.0485 0.0259 0.0225 0.0338 0.0471 3.20E-07 0.048 0.053 0.0707 0.1672 0.0835 0.0448 0.0455 0.0422 0.0575 0.0569 0.0768 0.0481 0.0258 0.0225 0.0337 0.047 4.80E-07 0.0477 0.0528 0.0698 0.1658 0.0825 0.0442 0.045 0.0417 0.0568 0.0559 0.0756 0.0476 0.0256 0.0225 0.0337 0.0469 7.00E-07 0.0474 0.0524 0.0697 0.1656 0.0818 0.0436 0.045 0.0416 0.0565 0.0558 0.0741 0.0458 0.0251 0.0224 0.0336 0.0467 1.00E-06 0.0454 0.0521 0.0695 0.1656 0.0818 0.0436 0.045 0.0415 0.0561 0.0554 0.0721 0.0445 0.0249 0.0218 0.0334 0.0466 1.50E-06 0.0453 0.052 0.0692 0.1654 0.0815 0.0434 0.0447 0.0415 0.055 0.0545 0.0706 0.042 0.0243 0.0215 0.0333 0.0462 2.00E-06 0.0451 0.0515 0.0688 0.1648 0.0813 0.043 0.0446 0.0413 0.0542 0.054 0.0681 0.0345 0.0229 0.0201 0.0316 0.0418 3.00E-06 0.0322 0.0483 0.0674 0.1633 0.081 0.0429 0.043 0.0404 0.0534 0.0523 0.0545 0.0201 0.0136 0.0116 0.0156 0.0204 4.00E-06 0.02 0.0421 0.0646 0.1624 0.0795 0.0411 0.0394 0.0385 0.0497 0.0485 0.0428 0.0137 0.0072 0.0068 0.008 0.0104 5.00E-06 0.0166 0.0367 0.0622 0.1606 0.0774 0.039 0.0362 0.0348 0.0438 0.0447 0.0374 0.0103 0.005 0.0042 0.0061 0.0078 7.00E-06 0.0129 0.0302 0.0555 0.1564 0.0747 0.0367 0.0324 0.03 0.0386 0.0373 0.0259 0.0058 0.0027 0.0024 0.005 0.0062 8.50E-06 0.0097 0.0243 0.0511 0.1536 0.0721 0.0354 0.0297 0.0264 0.034 0.0307 0.0169 0.0038 0.0019 0.0015 0.0023 0.0029 1.00E-05 0.007 0.0194 0.0473 0.1502 0.07 0.0327 0.0275 0.0241 0.0304 0.0244 0.0133 0.003 0.0017 0.0007 0.0015 0.0019 1.50E-05 0.0032 0.0112 0.0368 0.1387 0.0639 0.0281 0.0217 0.0178 0.0206 0.0118 0.0063 0.0013 0.0008 0.0002 0.0007 0.0008 2.00E-05 0.0018 0.0063 0.0301 0.1264 0.057 0.0238 0.0167 0.0124 0.0129 0.0062 0.0033 0.0002 0.0007 0.0001 0.0002 0.0005 2.50E-05 0.0014 0.0041 0.0243 0.1159 0.0492 0.0198 0.0117 0.0082 0.0086 0.0044 0.0024 0.0002 0.0006 0.0001 0.0002 0.0002 3.00E-05 0.001 0.0028 0.0202 0.1037 0.043 0.0163 0.0093 0.0064 0.0074 0.003 0.0016 0.0001 0.0005 0.0001 0.0002 0.0001 3.50E-05 0.0007 0.0024 0.0162 0.0921 0.0381 0.0132 0.0074 0.0057 0.0062 0.0023 0.0014 0

0.0005 0.0001 0.0001 0

4.00E-05 0.0006 0.0016 0.0139 0.0783 0.0346 0.011 0.0063 0.0044 0.0043 0.0016 0.0011 0

0.0003 0.0001 0

0 5.00E-05 0.0003 0.0011 0.0109 0.0588 0.0284 0.0092 0.0048 0.003 0.0024 0.001 0.0007 0

0.0002 0.0001 0

0 6.00E-05 0.0003 0.0009 0.0077 0.0393 0.0201 0.0067 0.0028 0.0017 0.0014 0.0009 0.0005 0

0.0002 0.0001 0

0 7.00E-05 0.0001 0.0008 0.0051 0.0248 0.0133 0.0046 0.0021 0.0014 0.0008 0.0005 0.0003 0

0.0001 0.0001 0

0 8.50E-05 0.0001 0.0002 0.0029 0.0107 0.0072 0.0018 0.0013 0.0003 0.0001 0.0001 0.0003 0

0.0001 0

0 0

1.00E-04 0.0001 0.0002 0.0016 0.0037 0.0034 0.0017 0.0011 0.0002 0

0 0.0001 0

0 0

0 0

1.30E-04 0

0.0001 0.0001 0.0002 0.0002 0.0001 0.0003 0

0 0

0 0

0 0

0 0

1.70E-04 0

0 0

0.0001 0

0 0

0 0

0 0

0 0

0 0

0 2.00E-04 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-101 2001 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES LPZ Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 3.50E-09 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 1.00E-08 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 2.50E-08 0.0499 0.072 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.083 0.1147 0.0628 0.0314 0.0204 0.0296 0.0398 7.00E-08 0.0495 0.0719 0.0827 0.1446 0.0676 0.0451 0.0424 0.0463 0.0678 0.0829 0.1131 0.0624 0.0314 0.0204 0.0296 0.0397 1.00E-07 0.0476 0.0707 0.0827 0.1446 0.0676 0.045 0.042 0.0458 0.0663 0.0807 0.1052 0.0582 0.031 0.0204 0.0295 0.0387 1.50E-07 0.045 0.0689 0.0822 0.1446 0.0674 0.0447 0.0418 0.0455 0.0648 0.076 0.0916 0.0539 0.0303 0.0202 0.0292 0.0377 2.20E-07 0.0439 0.0674 0.0807 0.1442 0.0673 0.0444 0.0415 0.0451 0.0632 0.0723 0.0838 0.0524 0.03 0.0202 0.0292 0.0376 3.20E-07 0.0435 0.0664 0.0793 0.1433 0.0667 0.044 0.041 0.0444 0.0626 0.0704 0.0817 0.0521 0.0297 0.0201 0.0292 0.0375 4.80E-07 0.0435 0.0663 0.0792 0.1431 0.0658 0.0436 0.0408 0.0441 0.0617 0.0702 0.0816 0.0512 0.0295 0.0201 0.029 0.0372 7.00E-07 0.043 0.0661 0.0792 0.1431 0.0656 0.0436 0.0407 0.044 0.0612 0.0699 0.0805 0.0496 0.0292 0.0201 0.0288 0.0365 1.00E-06 0.0423 0.0651 0.0791 0.1431 0.0656 0.0436 0.0405 0.044 0.0607 0.0694 0.0776 0.0483 0.029 0.0199 0.0287 0.0363 1.50E-06 0.0423 0.0643 0.0782 0.1429 0.0656 0.0435 0.0402 0.0436 0.0603 0.0687 0.0755 0.0473 0.0278 0.0196 0.0284 0.0357 2.00E-06 0.0422 0.0637 0.0778 0.1427 0.0652 0.0429 0.04 0.0435 0.0602 0.0682 0.074 0.0412 0.0243 0.0164 0.0257 0.0319 3.00E-06 0.0329 0.0609 0.0768 0.142 0.0649 0.0416 0.0386 0.0407 0.0558 0.0648 0.0558 0.0232 0.0139 0.0088 0.0126 0.0173 4.00E-06 0.0214 0.0508 0.0705 0.1407 0.0636 0.0399 0.0344 0.0355 0.0515 0.058 0.0407 0.0163 0.0097 0.0043 0.0068 0.0095 5.00E-06 0.0173 0.0435 0.0632 0.1383 0.0618 0.037 0.0307 0.032 0.0453 0.0503 0.0326 0.0131 0.0065 0.0033 0.0053 0.0078 7.00E-06 0.0136 0.0335 0.0563 0.1344 0.058 0.0334 0.0255 0.0269 0.0377 0.0384 0.0224 0.0071 0.004 0.0025 0.003 0.0046 8.50E-06 0.01 0.025 0.0521 0.1315 0.0552 0.0312 0.0231 0.0244 0.0323 0.0295 0.0133 0.0047 0.0031 0.0018 0.0016 0.0028 1.00E-05 0.0071 0.0206 0.0488 0.13 0.0533 0.0292 0.0209 0.0224 0.0289 0.0239 0.0096 0.0038 0.002 0.0013 0.0012 0.0021 1.50E-05 0.0029 0.0121 0.0368 0.124 0.0486 0.0251 0.0172 0.0156 0.0172 0.0104 0.004 0.0012 0.001 0.0005 0.0006 0.0009 2.00E-05 0.0021 0.0077 0.0301 0.1159 0.043 0.022 0.013 0.0116 0.0104 0.0068 0.0022 0.0006 0.0002 0.0003 0.0001 0.0005 2.50E-05 0.0012 0.0063 0.0262 0.1095 0.0361 0.0169 0.0093 0.0089 0.0081 0.0051 0.0014 0.0003 0.0001 0.0003 0.0001 0.0003 3.00E-05 0.0009 0.0052 0.0236 0.1016 0.0332 0.0146 0.0077 0.0083 0.0067 0.0033 0.0012 0.0002 0

0.0003 0.0001 0.0002 3.50E-05 0.0006 0.0044 0.0201 0.0916 0.0311 0.0135 0.0074 0.0074 0.005 0.0024 0.0008 0.0002 0

0.0002 0.0001 0.0002 4.00E-05 0.0005 0.0036 0.0166 0.0793 0.0281 0.0126 0.0067 0.0056 0.0029 0.0017 0.0005 0.0002 0

0 0.0001 0.0002 5.00E-05 0.0003 0.0029 0.0119 0.0621 0.0225 0.0104 0.0046 0.0037 0.0015 0.0009 0.0002 0.0001 0

0 0

0.0001 6.00E-05 0.0003 0.0018 0.0084 0.0432 0.0151 0.0071 0.0031 0.0018 0.001 0.0005 0.0002 0.0001 0

0 0

0 7.00E-05 0.0002 0.0015 0.0061 0.0273 0.01 0.0048 0.0023 0.0015 0.0003 0.0001 0.0002 0.0001 0

0 0

0 8.50E-05 0.0002 0.0008 0.0025 0.0107 0.0041 0.0024 0.0009 0.0008 0.0001 0.0001 0.0001 0.0001 0

0 0

0 1.00E-04 0.0001 0.0005 0.0015 0.0038 0.0017 0.0015 0.0005 0.0003 0

0.0001 0.0001 0.0001 0

0 0

0 1.30E-04 0

0.0001 0.0002 0.0003 0.0002 0.0002 0.0002 0

0 0

0 0

0 0

0 0

1.70E-04 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-102 2002 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES LPZ Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 3.50E-09 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 1.00E-08 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 2.50E-08 0.0392 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.1004 0.0621 0.0297 0.0214 0.0287 0.0348 7.00E-08 0.039 0.0769 0.1096 0.1414 0.0673 0.0497 0.062 0.0474 0.061 0.0683 0.0996 0.0615 0.0297 0.0213 0.0287 0.0346 1.00E-07 0.0385 0.0764 0.109 0.1414 0.0673 0.0497 0.0613 0.0469 0.0603 0.0677 0.096 0.0587 0.0287 0.021 0.0274 0.0331 1.50E-07 0.0377 0.0746 0.108 0.1412 0.067 0.0494 0.0607 0.0461 0.0579 0.0656 0.09 0.0549 0.028 0.0196 0.0273 0.0323 2.20E-07 0.0373 0.0743 0.1068 0.141 0.0666 0.049 0.0603 0.0448 0.0564 0.0619 0.0854 0.053 0.0273 0.0191 0.0271 0.032 3.20E-07 0.0371 0.0739 0.1064 0.1405 0.0657 0.0489 0.0598 0.044 0.056 0.0601 0.0846 0.0527 0.0272 0.019 0.0271 0.0318 4.80E-07 0.0371 0.0737 0.1063 0.1397 0.065 0.0482 0.0595 0.0437 0.0557 0.0595 0.0843 0.0523 0.027 0.019 0.0271 0.0318 7.00E-07 0.0365 0.0737 0.106 0.1397 0.0649 0.0482 0.0595 0.0436 0.0554 0.0594 0.0829 0.0516 0.0266 0.0189 0.0266 0.0314 1.00E-06 0.0363 0.0728 0.1059 0.1397 0.0649 0.0482 0.0591 0.0435 0.0553 0.0591 0.0808 0.0513 0.0266 0.0188 0.0264 0.0314 1.50E-06 0.0361 0.0725 0.1056 0.1397 0.0649 0.0479 0.0587 0.0432 0.0553 0.0587 0.0799 0.0485 0.0255 0.0174 0.026 0.0314 2.00E-06 0.0353 0.0724 0.1055 0.1391 0.0648 0.0479 0.0583 0.043 0.0551 0.0581 0.0779 0.0416 0.0222 0.0152 0.0231 0.0292 3.00E-06 0.0286 0.0667 0.1025 0.138 0.0633 0.0463 0.0549 0.0413 0.0522 0.0558 0.0551 0.0258 0.0124 0.0098 0.0121 0.0141 4.00E-06 0.0198 0.0551 0.0928 0.1353 0.0618 0.0428 0.0481 0.0377 0.0475 0.0496 0.037 0.0182 0.0092 0.0066 0.0071 0.0086 5.00E-06 0.016 0.0499 0.0868 0.1322 0.0604 0.0392 0.0421 0.0346 0.0441 0.0438 0.0279 0.0139 0.0066 0.0048 0.0055 0.0074 7.00E-06 0.0108 0.0379 0.0753 0.1285 0.0566 0.0353 0.0364 0.0288 0.0358 0.034 0.0179 0.0081 0.0038 0.0027 0.0035 0.0051 8.50E-06 0.0075 0.0318 0.0688 0.1251 0.0542 0.0318 0.0324 0.024 0.0299 0.025 0.0106 0.0055 0.0025 0.0017 0.0022 0.0022 1.00E-05 0.0058 0.025 0.0633 0.1215 0.0512 0.029 0.0289 0.0219 0.0256 0.0189 0.008 0.0043 0.0018 0.001 0.0015 0.0013 1.50E-05 0.0024 0.0123 0.0485 0.1126 0.0446 0.0228 0.0226 0.0149 0.0146 0.0097 0.0037 0.0014 0.001 0.0006 0.0006 0.0008 2.00E-05 0.0014 0.0066 0.0358 0.0989 0.0382 0.0182 0.0165 0.01 0.0082 0.0053 0.0017 0.0007 0.0005 0.0002 0.0003 0.0006 2.50E-05 0.0013 0.0046 0.0303 0.0893 0.0302 0.0129 0.0118 0.0056 0.0059 0.0029 0.0009 0.0002 0.0005 0

0.0001 0.0003 3.00E-05 0.0008 0.003 0.0272 0.0823 0.0271 0.0114 0.0086 0.0046 0.0045 0.0023 0.0002 0.0002 0.0005 0

0 0.0001 3.50E-05 0.0005 0.0027 0.0236 0.0709 0.0229 0.0091 0.0066 0.0038 0.0033 0.0016 0

0.0001 0.0005 0

0 0.0001 4.00E-05 0.0002 0.0021 0.0209 0.0604 0.0212 0.0084 0.0053 0.003 0.0024 0.0009 0

0.0001 0.0005 0

0 0.0001 5.00E-05 0.0002 0.0014 0.0152 0.0448 0.0175 0.0066 0.0043 0.0015 0.0013 0.0007 0

0.0001 0.0003 0

0 0

6.00E-05 0.0002 0.0012 0.0109 0.0322 0.012 0.0035 0.003 0.0009 0.001 0.0005 0

0 0.0002 0

0 0

7.00E-05 0

0.001 0.0081 0.019 0.0071 0.0025 0.0018 0.0007 0.0006 0

0 0

0.0001 0

0 0

8.50E-05 0

0.0005 0.0036 0.006 0.0038 0.0012 0.0009 0.0005 0.0001 0

0 0

0.0001 0

0 0

1.00E-04 0

0.0002 0.0012 0.0023 0.0021 0.0007 0.0003 0.0002 0

0 0

0 0.0001 0

0 0

1.30E-04 0

0 0.0001 0

0 0

0.0001 0

0 0

0 0

0 0

0 0

1.70E-04 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Table 2.3-103 2003 Probability values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES LPZ Probability that the X/Q is Greater than the Adjacent Quantized Level DIRECTION QUANTIZED LEVEL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 0.00E+00 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1.00E-10 5.13E-02 7.05E-02 9.23E-02 1.56E-01 7.49E-02 4.53E-02 4.87E-02 4.26E-02 6.18E-02 7.04E-02 1.04E-01 5.99E-02 3.03E-02 2.13E-02 3.15E-02 4.20E-02 3.50E-09 5.13E-02 7.05E-02 9.23E-02 1.56E-01 7.49E-02 4.53E-02 4.87E-02 4.26E-02 6.18E-02 7.04E-02 1.04E-01 5.99E-02 3.03E-02 2.13E-02 3.15E-02 4.20E-02 1.00E-08 5.13E-02 7.05E-02 9.23E-02 1.56E-01 7.49E-02 4.53E-02 4.87E-02 4.26E-02 6.18E-02 7.04E-02 1.04E-01 5.99E-02 3.03E-02 2.13E-02 3.15E-02 4.20E-02 2.50E-08 5.13E-02 7.05E-02 9.23E-02 1.56E-01 7.49E-02 4.53E-02 4.87E-02 4.26E-02 6.18E-02 7.04E-02 1.04E-01 5.99E-02 3.03E-02 2.13E-02 3.15E-02 4.20E-02 7.00E-08 5.12E-02 7.04E-02 9.23E-02 1.56E-01 7.49E-02 4.53E-02 4.87E-02 4.26E-02 6.18E-02 7.04E-02 1.04E-01 5.94E-02 3.03E-02 2.13E-02 3.15E-02 4.19E-02 1.00E-07 5.05E-02 6.95E-02 9.21E-02 1.56E-01 7.49E-02 4.53E-02 4.83E-02 4.24E-02 6.12E-02 6.96E-02 9.92E-02 5.58E-02 2.91E-02 2.10E-02 3.12E-02 4.14E-02 1.50E-07 4.87E-02 6.73E-02 9.09E-02 1.55E-01 7.47E-02 4.51E-02 4.78E-02 4.18E-02 5.90E-02 6.66E-02 8.87E-02 5.21E-02 2.74E-02 2.02E-02 3.09E-02 4.08E-02 2.20E-07 4.81E-02 6.57E-02 8.89E-02 1.55E-01 7.43E-02 4.45E-02 4.66E-02 4.05E-02 5.65E-02 6.29E-02 8.25E-02 5.07E-02 2.70E-02 2.00E-02 3.07E-02 4.05E-02 3.20E-07 4.78E-02 6.48E-02 8.75E-02 1.54E-01 7.37E-02 4.38E-02 4.59E-02 3.98E-02 5.54E-02 6.08E-02 8.05E-02 5.03E-02 2.68E-02 2.00E-02 3.07E-02 4.03E-02 4.80E-07 4.77E-02 6.47E-02 8.72E-02 1.53E-01 7.27E-02 4.31E-02 4.55E-02 3.95E-02 5.49E-02 6.03E-02 8.00E-02 4.97E-02 2.67E-02 2.00E-02 3.06E-02 4.02E-02 7.00E-07 4.71E-02 6.43E-02 8.71E-02 1.53E-01 7.24E-02 4.29E-02 4.54E-02 3.94E-02 5.46E-02 6.02E-02 7.89E-02 4.80E-02 2.61E-02 1.99E-02 3.04E-02 3.99E-02 1.00E-06 4.63E-02 6.35E-02 8.67E-02 1.53E-01 7.23E-02 4.29E-02 4.52E-02 3.93E-02 5.43E-02 5.97E-02 7.66E-02 4.69E-02 2.58E-02 1.94E-02 3.02E-02 3.96E-02 1.50E-06 4.62E-02 6.29E-02 8.60E-02 1.53E-01 7.22E-02 4.27E-02 4.49E-02 3.90E-02 5.36E-02 5.87E-02 7.48E-02 4.49E-02 2.50E-02 1.90E-02 3.00E-02 3.92E-02 2.00E-06 4.51E-02 6.25E-02 8.57E-02 1.52E-01 7.20E-02 4.23E-02 4.45E-02 3.87E-02 5.31E-02 5.82E-02 7.26E-02 3.77E-02 2.26E-02 1.72E-02 2.80E-02 3.52E-02 3.00E-06 3.19E-02 5.78E-02 8.38E-02 1.52E-01 7.13E-02 4.13E-02 4.26E-02 3.72E-02 5.11E-02 5.62E-02 5.57E-02 2.19E-02 1.30E-02 1.01E-02 1.43E-02 1.76E-02 4.00E-06 2.06E-02 4.76E-02 7.65E-02 1.49E-01 6.96E-02 3.88E-02 3.87E-02 3.43E-02 4.71E-02 5.06E-02 4.18E-02 1.57E-02 8.24E-03 5.80E-03 7.80E-03 9.54E-03 5.00E-06 1.66E-02 4.12E-02 7.06E-02 1.47E-01 6.74E-02 3.65E-02 3.53E-02 3.13E-02 4.24E-02 4.49E-02 3.45E-02 1.20E-02 5.86E-03 4.04E-03 5.96E-03 7.50E-03 7.00E-06 1.23E-02 3.24E-02 6.17E-02 1.42E-01 6.37E-02 3.35E-02 3.03E-02 2.61E-02 3.60E-02 3.60E-02 2.38E-02 7.02E-03 3.58E-03 2.52E-03 4.30E-03 5.38E-03 8.50E-06 9.08E-03 2.57E-02 5.61E-02 1.39E-01 6.12E-02 3.15E-02 2.73E-02 2.31E-02 3.14E-02 2.85E-02 1.50E-02 4.68E-03 2.52E-03 1.64E-03 2.34E-03 2.58E-03 1.00E-05 6.80E-03 2.10E-02 5.20E-02 1.36E-01 5.84E-02 2.91E-02 2.45E-02 2.10E-02 2.77E-02 2.27E-02 1.14E-02 3.64E-03 1.86E-03 9.19E-04 1.46E-03 1.66E-03 1.50E-05 3.04E-03 1.15E-02 3.94E-02 1.27E-01 5.26E-02 2.44E-02 1.96E-02 1.54E-02 1.78E-02 1.09E-02 5.06E-03 1.40E-03 1.00E-03 4.00E-04 6.60E-04 7.80E-04 2.00E-05 2.08E-03 6.82E-03 3.03E-02 1.15E-01 4.65E-02 2.07E-02 1.52E-02 1.07E-02 1.05E-02 6.40E-03 2.86E-03 5.40E-04 5.60E-04 2.00E-04 2.20E-04 4.80E-04 2.50E-05 1.48E-03 5.12E-03 2.53E-02 1.06E-01 3.94E-02 1.59E-02 1.10E-02 7.10E-03 7.70E-03 4.32E-03 1.90E-03 3.40E-04 4.80E-04 1.20E-04 1.20E-04 2.40E-04 3.00E-05 9.80E-04 3.84E-03 2.22E-02 9.65E-02 3.51E-02 1.35E-02 8.88E-03 5.94E-03 6.34E-03 3.06E-03 1.26E-03 2.40E-04 3.60E-04 9.99E-05 1.00E-04 1.20E-04 3.50E-05 7.40E-04 3.22E-03 1.90E-02 8.52E-02 3.15E-02 1.14E-02 7.24E-03 5.16E-03 4.92E-03 2.14E-03 9.21E-04 1.60E-04 3.40E-04 8.00E-05 6.00E-05 7.98E-05 4.00E-05 5.00E-04 2.56E-03 1.62E-02 7.34E-02 2.82E-02 1.04E-02 6.18E-03 3.98E-03 3.22E-03 1.40E-03 6.20E-04 9.99E-05 2.40E-04 4.01E-05 1.99E-05 7.98E-05 5.00E-05 3.20E-04 1.84E-03 1.23E-02 5.63E-02 2.32E-02 8.68E-03 4.88E-03 2.64E-03 1.88E-03 8.20E-04 4.21E-04 7.99E-05 1.40E-04 4.01E-05 0.00E+00 4.00E-05 6.00E-05 2.80E-04 1.44E-03 8.84E-03 3.74E-02 1.60E-02 5.94E-03 3.24E-03 1.42E-03 1.10E-03 6.00E-04 2.20E-04 1.99E-05 1.20E-04 4.01E-05 0.00E+00 2.00E-05 7.00E-05 1.20E-04 1.14E-03 6.54E-03 2.34E-02 1.04E-02 4.22E-03 2.30E-03 1.08E-03 6.81E-04 2.81E-04 1.40E-04 1.99E-05 6.00E-05 4.01E-05 0.00E+00 2.00E-05 8.50E-05 9.99E-05 5.80E-04 3.16E-03 9.44E-03 5.46E-03 2.22E-03 1.30E-03 5.00E-04 1.40E-04 1.61E-04 7.99E-05 1.99E-05 6.00E-05 0.00E+00 0.00E+00 2.00E-05 1.00E-04 5.99E-05 3.80E-04 1.52E-03 3.42E-03 2.72E-03 1.56E-03 7.41E-04 2.80E-04 8.02E-05 6.01E-05 3.99E-05 1.99E-05 1.99E-05 0.00E+00 0.00E+00 2.00E-05 1.30E-04 2.00E-05 3.99E-05 1.60E-04 3.00E-04 4.01E-04 1.20E-04 2.40E-04 2.00E-05 4.01E-05 2.00E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.70E-04 0.00E+00 0.00E+00 2.00E-05 4.00E-05 4.02E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.00E-04 0.00E+00 0.00E+00 2.00E-05 2.00E-05 2.00E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.50E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.00E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.50E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.00E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.00E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.00E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.00E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.50E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.00E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.40E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.00E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.00E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.00E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Table 2.3-104 1999 - 2003 Average Probability Values for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at SSES LPZ Probability that the X/Q is Greater than the Adjacent Quantized Level QUANTIZED LEVEL N

NNE NE NW ENE E

ESE SE NNW DIRECTION SSE S

SSW SW WSW W

WNW

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-105

SUMMARY

OF LONG-TERM X/Q (SEC/M3) RESULTS AT 4827 METER LPZ USNRC Reg. Guide1.145 Interpolation Methodology Annual Average Period of Record 0-8 hours 8-24 hours 24-96 hours96-720 hours 8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> 0.5%*

50%**

0.5%*

50%**

0.5%*

50%**

0.5%*

50%**

Direction Dependent Direction Independent 1999 5.4E-05 4.6E-06 3.8E-05 3.7E-06 1.8E-05 2.3E-06 6.3E-06 1.1E-06 1.7E-06 4.8E-07 2000 4.9E-05 4.8E-06 3.5E-05 3.8E-06 1.7E-05 2.3E-06 6.0E-06 1.1E-06 1.7E-06 4.8E-07 2001 5.0E-05 5.4E-06 3.6E-05 4.3E-06 1.7E-05 2.6E-06 6.1E-06 1.3E-06 1.7E-06 5.3E-07 2002 5.0E-05 4.5E-06 3.6E-05 3.6E-06 1.7E-05 2.2E-06 6.1E-06 1.1E-06 1.7E-06 4.5E-07 2003 4.6E-05 4.7E-06 3.3E-05 3.7E-06 1.6E-05 2.2E-06 5.9E-06 1.1E-06 1.7E-06 4.4E-07 5-year Combined 4.9E-05 4.8E-06 3.5E-05 3.8E-06 1.7E-05 2.3E-06 6.1E-06 1.1E-06 1.7E-06 4.7E-07

  • direction dependent values (see Figure 2.3-10)
    • direction independent values (see Figure 2.3-10)

I I

I I

I I

I I

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-106 DISTANCES AND TERRAIN/RECIRCULATION CORRECTION FACTORS FOR SSES 2003 LAND USE CENSUS LOCATIONS RESIDENCE GARDEN AFFECTED SECTOR MILES Terrain Correction Factor AFFECTED SECTOR MILES Terrain Correction Factor N

1.3 2.15 N

3.2 2.19 NNE 1

2.50 NNE 2.3 2.55 NE 0.9 2.33 NE 2.7 2.47 ENE 2.1 2.42 ENE 2.4 2.48 E

1.4 2.09 E

1.8 2.07 ESE 0.5 2.58 ESE 2.5 2.00 SE 0.5 2.43 SE 0.6 2.44 SSE 0.6 2.71 SSE 1.5 2.44 S

1 2.46 S

1.1 2.43 SSW 0.9 2.39 SSW 1.2 2.35 SW 1.5 2.14 SW 1.9 2.11 WSW 1.3 2.32 WSW 1.3 2.32 W

1.2 2.18 W

1.2 2.18 WNW 0.8 2.74 WNW NW 0.8 3.30 NW 1.8 3.06 NNW 0.6 2.53 NNW 4

2.40 PRODUCTION ANIMAL DAIRY ANIMAL AFFECTED SECTOR MILES Terrain Correction Factor AFFECTED SECTOR MILES Terrain Correction Factor NNE 2.3 2.55 E

4.5 1.80 ENE 2.4 2.48 ESE 2.7 1.96 E

1.4 2.09 ESE 4.2 1.58 SSW 3

2.35 SSW 3

2.11 SSW 3.5 1.88 SSW 3.1 2.06 WSW 1.7 2.34 SSW 3.5 1.88 NW 1.8 3.06 SSW 14.01 1.03 WSW 1.7 2.34 W

5 1.46 NNW 4.2 2.4 Distances to the nearest garden, residence, dairy animal and production animal in each of the affected sectors was provided by the 2003 SSES Land Use Census.

The terrain/recirculation correction factors listed for the distances in the above tables were mathematically interpolated from the terrain/recirculation factors quoted for standard distances in the SSES Final Safety Analysis Report.

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 Table 2.3-107 1999 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE SITE BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.59 5.57E-06 5.55E-06 5.03E-06 1.75E-08 NNE 0.78 3.88E-06 3.86E-06 3.43E-06 1.51E-08 NE 0.7 4.40E-06 4.39E-06 3.93E-06 2.70E-08 ENE 0.86 1.50E-06 1.50E-06 1.32E-06 1.29E-08 E

0.8 8.48E-07 8.46E-07 7.50E-07 6.68E-09 ESE 0.5 1.13E-06 1.13E-06 1.03E-06 9.26E-09 SE 0.43 2.39E-06 2.39E-06 2.21E-06 1.97E-08 SSE 0.41 3.14E-06 3.14E-06 2.91E-06 2.88E-08 S

0.38 6.71E-06 6.70E-06 6.25E-06 4.66E-08 SSW 0.39 1.07E-05 1.07E-05 9.96E-06 5.41E-08 SW 0.61 1.13E-05 1.13E-05 1.02E-05 2.86E-08 WSW 1.22 1.28E-05 1.27E-05 1.10E-05 1.66E-08 W

1.03 7.68E-06 7.61E-06 6.67E-06 1.00E-08 WNW 0.61 1.04E-05 1.04E-05 9.38E-06 1.72E-08 NW 0.66 7.44E-06 7.40E-06 6.67E-06 1.70E-08 NNW 0.59 5.14E-06 5.12E-06 4.64E-06 1.42E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 Table 2.3-108 2000 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE SITE BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.59 6.83E-06 6.80E-06 6.16E-06 2.10E-08 NNE 0.78 4.35E-06 4.33E-06 3.86E-06 1.51E-08 NE 0.7 4.17E-06 4.16E-06 3.73E-06 2.61E-08 ENE 0.86 1.40E-06 1.39E-06 1.23E-06 1.14E-08 E

0.8 8.89E-07 8.86E-07 7.86E-07 6.31E-09 ESE 0.5 1.57E-06 1.56E-06 1.43E-06 1.23E-08 SE 0.43 2.60E-06 2.60E-06 2.40E-06 2.20E-08 SSE 0.41 4.09E-06 4.09E-06 3.79E-06 3.52E-08 S

0.38 6.21E-06 6.20E-06 5.78E-06 4.11E-08 SSW 0.39 1.22E-05 1.22E-05 1.14E-05 4.90E-08 SW 0.61 1.24E-05 1.24E-05 1.12E-05 2.90E-08 WSW 1.22 1.24E-05 1.23E-05 1.07E-05 1.65E-08 W

1.03 7.62E-06 7.55E-06 6.61E-06 1.03E-08 WNW 0.61 8.27E-06 8.23E-06 7.45E-06 1.55E-08 NW 0.66 8.40E-06 8.36E-06 7.53E-06 1.68E-08 NNW 0.59 5.99E-06 5.96E-06 5.41E-06 1.41E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-109 2001 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE SITE BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.59 7.27E-06 7.24E-06 6.56E-06 2.22E-08 NNE 0.78 4.18E-06 4.16E-06 3.70E-06 1.52E-08 NE 0.7 4.34E-06 4.33E-06 3.87E-06 2.77E-08 ENE 0.86 1.35E-06 1.34E-06 1.19E-06 1.16E-08 E

0.8 7.05E-07 7.03E-07 6.24E-07 5.37E-09 ESE 0.5 1.17E-06 1.17E-06 1.07E-06 8.69E-09 SE 0.43 2.89E-06 2.88E-06 2.66E-06 2.37E-08 SSE 0.41 3.85E-06 3.84E-06 3.56E-06 3.06E-08 S

0.38 6.07E-06 6.06E-06 5.65E-06 3.90E-08 SSW 0.39 1.01E-05 1.01E-05 9.35E-06 4.23E-08 SW 0.61 1.07E-05 1.06E-05 9.60E-06 2.23E-08 WSW 1.22 1.37E-05 1.36E-05 1.18E-05 1.74E-08 W

1.03 8.94E-06 8.86E-06 7.76E-06 1.12E-08 WNW 0.61 1.09E-05 1.08E-06 9.77E-06 1.79E-08 NW 0.66 8.76E-06 8.72E-06 7.85E-06 1.94E-08 NNW 0.59 7.07E-06 7.04E-06 6.38E-06 1.80E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-110 2002 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE SITE BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.59 6.61E-06 6.58E-06 5.97E-06 2.28E-08 NNE 0.78 4.44E-06 4.43E-06 3.94E-06 1.87E-08 NE 0.7 4.03E-06 4.02E-06 3.60E-06 3.03E-08 ENE 0.86 1.58E-06 1.57E-06 1.39E-06 1.28E-08 E

0.8 9.13E-07 9.10E-07 8.08E-07 6.69E-09 ESE 0.5 1.30E-06 1.30E-06 1.19E-06 1.07E-08 SE 0.43 2.10E-06 2.10E-06 1.94E-06 1.90E-08 SSE 0.41 3.28E-06 3.28E-06 3.04E-06 2.91E-08 S

0.38 5.71E-06 5.70E-06 5.31E-06 3.78E-08 SSW 0.39 1.24E-05 1.23E-05 1.15E-05 5.14E-08 SW 0.61 1.13E-05 1.13E-05 1.02E-05 2.45E-08 WSW 1.22 1.26E-05 1.25E-05 1.08E-05 1.48E-08 W

1.03 6.95E-06 6.89E-06 6.04E-06 8.88E-09 WNW 0.61 1.02E-05 1.02E-05 9.19E-06 1.74E-08 NW 0.66 7.22E-06 7.18E-06 6.46E-06 1.63E-08 NNW 0.59 6.63E-06 6.61E-06 5.99E-06 1.79E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-111 2003 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE SITE BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.59 6.10E-06 6.08E-06 5.51E-06 2.05E-08 NNE 0.78 3.87E-06 3.86E-06 3.43E-06 1.54E-08 NE 0.7 3.70E-06 3.69E-06 3.30E-06 2.65E-08 ENE 0.86 1.61E-06 1.61E-06 1.42E-06 1.27E-08 E

0.8 9.09E-07 9.06E-07 8.04E-07 6.37E-09 ESE 0.5 1.33E-06 1.33E-06 1.22E-06 1.12E-08 SE 0.43 2.09E-06 2.09E-06 1.93E-06 1.84E-08 SSE 0.41 2.80E-06 2.80E-06 2.59E-06 2.55E-08 S

0.38 4.69E-06 4.69E-06 4.37E-06 2.97E-08 SSW 0.39 1.28E-05 1.28E-05 1.19E-06 5.49E-08 SW 0.61 1.45E-05 1.45E-05 1.31E-05 3.25E-08 WSW 1.22 1.10E-05 1.09E-05 9.46E-06 1.45E-08 W

1.03 6.36E-06 6.31E-06 5.53E-06 8.85E-09 WNW 0.61 9.16E-06 9.12E-06 8.25E-06 1.91E-08 NW 0.66 9.36E-06 9.32E-06 8.39E-06 2.37E-08 NNW 0.59 6.10E-06 6.08E-06 5.51E-06 1.83E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-112 1999 - 2003 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2) ESTIMATES AT THE SITE BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.59 6.47E-06 6.45E-06 5.85E-06 2.08E-08 NNE 0.78 4.15E-06 4.13E-06 3.67E-06 1.59E-08 NE 0.7 4.13E-06 4.12E-06 3.69E-06 2.75E-08 ENE 0.86 1.49E-06 1.48E-06 1.31E-06 1.23E-08 E

0.8 8.53E-07 8.50E-07 7.55E-07 6.28E-09 ESE 0.5 1.30E-06 1.30E-06 1.19E-06 1.05E-08 SE 0.43 2.42E-06 2.41E-06 2.23E-06 2.06E-08 SSE 0.41 3.43E-06 3.43E-06 3.18E-06 2.98E-08 S

0.38 5.88E-06 5.87E-06 5.47E-06 3.88E-08 SSW 0.39 1.16E-05 1.16E-05 1.08E-05 5.03E-08 SW 0.61 1.21E-05 1.20E-05 1.09E-05 2.74E-08 WSW 1.22 1.25E-05 1.24E-05 1.07E-05 1.60E-08 W

1.03 7.51E-06 7.45E-06 6.52E-06 9.85E-09 WNW 0.61 9.78E-06 9.73E-06 8.81E-06 1.74E-08 NW 0.66 8.24E-06 8.19E-06 7.38E-06 1.86E-08 NNW 0.59 6.19E-06 6.16E-06 5.59E-06 1.65E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-113 1999 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE EXCLUSION AREA BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.34 1.23E-05 1.23E-05 1.15E-05 4.43E-08 NNE 0.34 1.09E-05 1.09E-05 1.02E-05 5.21E-08 NE 0.34 1.18E-05 1.18E-05 1.10E-05 8.56E-08 ENE 0.34 5.60E-06 5.60E-06 5.25E-06 5.80E-08 E

0.34 2.98E-06 2.98E-06 2.80E-06 2.81E-08 ESE 0.34 2.16E-06 2.16E-06 2.03E-06 1.92E-08 SE 0.34 3.39E-06 3.39E-06 3.18E-06 2.94E-08 SSE 0.34 4.01E-06 4.00E-06 3.76E-06 3.82E-08 S

0.34 7.75E-06 7.74E-06 7.27E-06 5.51E-08 SSW 0.34 1.32E-05 1.32E-05 1.24E-05 6.85E-08 SW 0.34 2.50E-05 2.49E-05 2.34E-05 7.10E-08 WSW 0.34 6.81E-05 6.80E-05 6.38E-05 1.06E-07 W

0.34 4.22E-05 4.22E-05 3.96E-05 6.73E-08 WNW 0.34 2.38E-05 2.37E-05 2.23E-05 4.43E-08 NW 0.34 1.96E-05 1.96E-05 1.84E-05 5.20E-08 NNW 0.34 1.03E-05 1.03E-05 9.68E-06 3.23E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-114 2000 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE EXCLUSION AREA BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.34 1.50E-05 1.50E-05 1.41E-05 5.30E-08 NNE 0.34 1.23E-05 1.23E-05 1.15E-05 5.22E-08 NE 0.34 1.14E-05 1.13E-05 1.06E-05 8.26E-08 ENE 0.34 5.29E-06 5.29E-06 4.96E-06 5.14E-08 E

0.34 3.16E-06 3.15E-06 2.96E-06 2.66E-08 ESE 0.34 3.00E-06 3.00E-06 2.82E-06 2.55E-08 SE 0.34 3.69E-06 3.69E-06 3.47E-06 3.30E-08 SSE 0.34 5.22E-06 5.22E-06 4.89E-06 4.66E-08 S

0.34 7.17E-06 7.17E-06 6.72E-06 4.85E-08 SSW 0.34 1.50E-05 1.50E-05 1.41E-05 6.20E-08 SW 0.34 2.74E-05 2.74E-05 2.57E-05 7.20E-08 WSW 0.34 6.45E-05 6.45E-05 6.05E-05 1.05E-07 W

0.34 4.12E-05 4.11E-05 3.86E-05 6.93E-08 WNW 0.34 1.88E-05 1.87E-05 1.76E-05 4.00E-08 NW 0.34 2.21E-05 2.21E-05 2.07E-05 5.14E-08 NNW 0.34 1.19E-05 1.19E-05 1.12E-05 3.22E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-115 2001 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE EXCLUSION AREA BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.34 1.61E-05 1.60E-05 1.51E-05 5.61E-08 NNE 0.34 1.17E-05 1.17E-05 1.10E-05 5.26E-08 NE 0.34 1.19E-05 1.18E-05 1.11E-05 8.78E-08 ENE 0.34 5.14E-06 5.14E-06 4.82E-06 5.23E-08 E

0.34 2.51E-06 2.51E-06 2.35E-06 2.26E-08 ESE 0.34 2.23E-06 2.23E-06 2.09E-06 1.80E-08 SE 0.34 4.12E-06 4.12E-06 3.86E-06 3.54E-08 SSE 0.34 4.90E-06 4.90E-06 4.60E-06 4.05E-08 S

0.34 7.01E-06 7.00E-06 6.57E-06 4.61E-08 SSW 0.34 1.23E-05 1.23E-05 1.16E-05 5.35E-08 SW 0.34 2.34E-05 2.34E-05 2.20E-05 5.53E-08 WSW 0.34 7.16E-05 7.15E-05 6.71E-05 1.11E-07 W

0.34 4.83E-05 4.83E-05 4.53E-05 7.56E-08 WNW 0.34 2.44E-05 2.43E-05 2.28E-05 4.62E-08 NW 0.34 2.29E-05 2.29E-05 2.15E-05 5.93E-08 NNW 0.34 1.40E-05 1.40E-05 1.31E-05 4.10E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev 64 Page 1 of 1 TABLE 2.3-116 2002 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE EXCLUSION AREA BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.34 1.45E-05 1.45E-05 1.36E-05 5.77E-08 NNE 0.34 1.25E-05 1.25E-05 1.17E-05 6.47E-08 NE 0.34 1.10E-05 1.10E-05 1.03E-05 9.60E-08 ENE 0.34 5.93E-06 5.93E-06 5.56E-06 5.79E-08 E

0.34 3.20E-06 3.20E-06 3.00E-06 2.82E-08 ESE 0.34 2.48E-06 2.48E-06 2.32E-06 2.22E-08 SE 0.34 2.99E-06 2.99E-06 2.81E-06 2.84E-08 SSE 0.34 4.19E-06 4.19E-06 3.93E-06 3.86E-08 S

0.34 6.58E-06 6.57E-06 6.17E-06 4.47E-08 SSW 0.34 1.52E-05 1.52E-05 1.42E-05 6.51E-08 SW 0.34 2.51E-05 2.51E-05 2.36E-05 6.08E-08 WSW 0.34 6.65E-05 6.64E-05 6.24E-05 9.45E-08 W

0.34 3.72E-05 3.71E-05 3.49E-05 5.98E-08 WNW 0.34 2.32E-05 2.31E-05 2.17E-05 4.47E-08 NW 0.34 1.91E-05 1.90E-05 1.79E-05 4.97E-08 NNW 0.34 1.33E-05 1.33E-05 1.25E-05 4.09E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 36 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-117 2003 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-2)

ESTIMATES AT THE EXCLUSION AREA BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.34 1.34E-05 1.34E-05 1.26E-05 5.19E-08 NNE 0.34 1.08E-05 1.08E-05 1.02E-05 5.33E-08 NE 0.34 1.00E-05 1.00E-05 9.38E-06 8.40E-08 ENE 0.34 5.94E-06 5.93E-06 5.57E-06 5.73E-08 E

0.34 3.18E-06 3.18E-06 2.98E-06 2.68E-08 ESE 0.34 2.53E-06 2.53E-06 2.38E-06 2.33E-08 SE 0.34 2.97E-06 2.97E-06 2.79E-06 2.75E-08 SSE 0.34 3.56E-06 3.56E-06 3.34E-06 3.38E-08 S

0.34 5.41E-06 5.40E-06 5.07E-06 3.51E-08 SSW 0.34 1.57E-05 1.57E-05 1.47E-05 6.96E-08 SW 0.34 3.21E-05 3.21E-05 3.01E-05 8.07E-08 WSW 0.34 5.65E-05 5.65E-05 5.30E-05 9.25E-08 W

0.34 3.37E-05 3.37E-05 3.16E-05 5.96E-08 WNW 0.34 2.05E-05 2.05E-05 1.92E-05 4.93E-08 NW 0.34 2.43E-05 2.43E-05 2.28E-05 7.25E-08 NNW 0.34 1.21E-05 1.21E-05 1.14E-05 4.18E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

I

SSES-FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-118 1999 - 2003 AVERAGE RELATIVE CONCENTRATION (sec/meter3) AND DEPOSITION (meter-

2) ESTIMATES AT THE EXCLUSION AREA BOUNDARY Affected Sector Relative Concentration (sec/meter3)

Deposition Distance (miles No Decay Undepleted 2.26 Days of Decay Undepleted 8.0 Days of Decay Depleted D/Q (meter-2)

N 0.34 1.43E-05 1.43E-05 1.34E-05 5.26E-08 NNE 0.34 1.16E-05 1.16E-05 1.09E-05 5.50E-08 NE 0.34 1.12E-05 1.12E-05 1.05E-05 8.72E-08 ENE 0.34 5.58E-06 5.58E-06 5.23E-06 5.54E-08 E

0.34 3.01E-06 3.00E-06 2.82E-06 2.65E-08 ESE 0.34 2.48E-06 2.48E-06 2.33E-06 2.16E-08 SE 0.34 3.43E-06 3.43E-06 3.22E-06 3.08E-08 SSE 0.34 4.38E-06 4.37E-06 4.11E-06 3.96E-08 S

0.34 6.78E-05 6.78E-06 6.36E-06 4.59E-08 SSW 0.34 1.43E-05 1.43E-05 1.34E-05 6.37E-08 SW 0.34 2.66E-05 2.66E-05 2.49E-05 6.80E-08 WSW 0.34 6.54E-05 6.54E-05 6.14E-05 1.02E-07 W

0.34 4.05E-05 4.05E-05 3.80E-05 6.64E-08 WNW 0.34 2.21E-05 2.21E-05 2.07E-05 4.49E-08 NW 0.34 2.16E-05 2.16E-05 2.02E-05 5.70E-08 NNW 0.34 1.23E-05 1.23E-05 1.16E-05 3.76E-08 The above values were calculated using the XDCALC atmospheric dispersion model with terrain/recirculation factors included.

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-119 1999 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST RESIDENCE AND GARDEN*

NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 1.3 1.72E-06 1.71E-06 1.47E-06 4.44E-09 2

NNE 1

2.85E-06 2.83E-06 2.48E-06 1.04E-08 3

NE 0.9 3.07E-06 3.05E-06 2.69E-06 1.77E-08 4

ENE 2.1 4.03E-07 4.01E-07 3.32E-07 3.06E-09 5

E 1.4 3.28E-07 3.27E-07 2.80E-07 2.30E-09 6

ESE 0.5 1.13E-06 1.13E-06 1.03E-06 9.24E-09 7

SE 0.5 1.90E-06 1.90E-06 1.74E-06 1.51E-08 8

SSE 0.6 1.87E-06 1.87E-06 1.69E-06 1.58E-08 9

S 1

1.69E-06 1.68E-06 1.47E-06 9.42E-09 10 SSW 0.9 3.23E-06 3.21E-06 2.83E-06 1.35E-08 11 SW 1.5 3.06E-06 3.03E-06 2.59E-06 6.42E-09 12 WSW 1.3 1.16E-05 1.15E-05 9.90E-06 1.49E-08 13 W

1.2 5.96E-06 5.90E-06 5.12E-06 7.54E-09 14 WNW 0.8 7.13E-06 7.08E-06 6.30E-06 1.12E-08 15 NW 0.8 6.11E-06 6.06E-06 5.40E-06 1.34E-08 16 NNW 0.6 5.02E-06 5.00E-06 4.52E-06 1.38E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 3.2 4.61E-07 4.52E-07 3.61E-07 9.99E-10 2

NNE 2.3 8.50E-07 8.40E-07 6.92E-07 2.73E-09 3

NE 2.7 6.27E-07 6.21E-07 5.02E-07 3.07E-09 4

ENE 2.1 4.03E-07 4.01E-07 3.32E-07 3.06E-09 5

E 1.8 2.21E-07 2.20E-07 1.84E-07 1.52E-09 6

ESE 2.5 7.59E-08 7.54E-08 6.14E-08 4.97E-10 7

SE 0.6 1.46E-06 1.46E-06 1.32E-06 1.11E-08 8

SSE 1.5 4.28E-07 4.26E-07 3.63E-07 2.99E-09 9

S 1.1 1.45E-06 1.44E-06 1.25E-06 7.92E-09 10 SSW 1.2 2.07E-06 2.06E-06 1.78E-06 8.11E-09 11 SW 1.9 2.15E-06 2.12E-06 1.78E-06 4.38E-09 12 WSW 1.3 1.16E-05 1.15E-05 9.90E-06 1.49E-08 13 W

1.2 5.96E-06 5.90E-06 5.12E-06 7.54E-09 14 WNW (1) 15 NW 1.8 1.71E-06 1.69E-06 1.43E-06 3.19E-09 16 NNW 4

2.87E-07 2.80E-07 2.18E-07 5.10E-10 (1)

No garden within 5 miles for this sector

  • Locations use the 2003 Land Use Census Locations

SSES-FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-120 2000 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST RESIDENCE AND GARDEN*

NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 1.3 2.11E-06 2.10E-06 1.81E-06 5.31E-09 2

NNE 1

3.19E-06 3.18E-06 2.78E-06 1.04E-08 3

NE 0.9 2.89E-06 2.88E-06 2.54E-06 1.71E-08 4

ENE 2.1 3.66E-07 3.64E-07 3.01E-07 2.71E-09 5

E 1.4 3.42E-07 3.40E-07 2.91E-07 2.17E-09 6

ESE 0.5 1.56E-06 1.56E-06 1.43E-06 1.23E-08 7

SE 0.5 2.07E-06 2.06E-06 1.89E-06 1.69E-08 8

SSE 0.6 2.44E-06 2.44E-06 2.20E-06 1.94E-08 9

S 1

1.56E-06 1.55E-06 1.35E-06 8.29E-09 10 SSW 0.9 3.69E-06 3.67E-06 3.24E-06 1.22E-08 11 SW 1.5 3.33E-06 3.30E-06 2.82E-06 6.51E-09 12 WSW 1.3 1.13E-05 1.12E-05 9.65E-06 1.49E-08 13 W

1.2 5.92E-06 5.87E-06 5.09E-06 7.77E-09 14 WNW 0.8 5.68E-06 5.64E-06 5.02E-06 1.00E-08 15 NW 0.8 6.90E-06 6.85E-06 6.10E-06 1.32E-08 16 NNW 0.6 5.84E-06 5.82E-06 5.27E-06 1.37E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 3.2 5.63E-07 5.53E-07 4.41E-07 1.20E-09 2

NNE 2.3 9.52E-07 9.41E-07 7.75E-07 2.74E-09 3

NE 2.7 5.76E-07 5.70E-07 4.62E-07 2.96E-09 4

ENE 2.1 3.66E-07 3.64E-07 3.01E-07 2.71E-09 5

E 1.8 2.30E-07 2.29E-07 1.92E-07 1.44E-09 6

ESE 2.5 1.04E-07 1.03E-07 8.43E-08 6.62E-10 7

SE 0.6 1.58E-06 1.58E-06 1.43E-06 1.25E-08 8

SSE 1.5 5.59E-07 5.56E-07 4.73E-07 3.65E-09 9

S 1.1 1.34E-06 1.33E-06 1.16E-06 6.97E-09 10 SSW 1.2 2.37E-06 2.36E-06 2.04E-06 7.34E-09 11 SW 1.9 2.33E-06 2.31E-06 1.93E-06 4.44E-09 12 WSW 1.3 1.13E-05 1.12E-05 9.65E-06 1.49E-08 13 W

1.2 5.92E-06 5.87E-06 5.09E-06 7.77E-09 15 NW 1.8 1.93E-06 1.91E-06 1.61E-06 3.15E-09 16 NNW 4

3.36E-07 3.27E-07 2.55E-07 5.09E-10 (1) No garden within 5 miles for this sector

  • Locations use the 2003 Land Use Census Locations

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-121 2001 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST RESIDENCE AND GARDEN*

NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 1.3 2.24E-06 2.22E-06 1.92E-06 5.62E-09 2

NNE 1

3.07E-06 3.06E-06 2.68E-06 1.05E-08 3

NE 0.9 3.00E-06 2.99E-06 2.63E-06 1.82E-08 4

ENE 2.1 3.52E-07 3.50E-07 2.89E-07 2.75E-09 5

E 1.4 2.71E-07 2.70E-07 2.31E-07 1.85E-09 6

ESE 0.5 1.17E-06 1.16E-06 1.07E-06 8.67E-09 7

SE 0.5 2.28E-06 2.28E-06 2.09E-06 1.82E-08 8

SSE 0.6 2.30E-06 2.29E-06 2.07E-06 1.68E-08 9

S 1

1.51E-06 1.51E-06 1.32E-06 7.88E-09 10 SSW 0.9 3.06E-06 3.05E-06 2.69E-06 1.05E-08 11 SW 1.5 2.88E-06 2.86E-06 2.44E-06 5.00E-09 12 WSW 1.3 1.24E-05 1.23E-05 1.06E-05 1.57E-08 13 W

1.2 6.95E-06 6.88E-06 5.97E-06 8.47E-09 14 WNW 0.8 7.49E-06 7.43E-06 6.62E-06 1.16E-08 15 NW 0.8 7.21E-06 7.16E-06 6.37E-06 1.52E-08 16 NNW 0.6 6.90E-06 6.87E-06 6.22E-06 1.75E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 3.2 5.95E-07 5.84E-07 4.66E-07 1.26E-09 2

NNE 2.3 9.17E-07 9.06E-07 7.46E-07 2.75E-09 3

NE 2.7 6.01E-07 5.94E-07 4.81E-07 3.15E-09 4

ENE 2.1 3.52E-07 3.50E-07 2.89E-07 2.75E-09 5

E 1.8 1.82E-07 1.81E-07 1.51E-07 1.23E-09 6

ESE 2.5 7.86E-08 7.80E-08 6.36E-08 4.66E-10 7

SE 0.6 1.74E-06 1.74E-06 1.57E-06 1.34E-08 8

SSE 1.5 5.27E-07 5.25E-07 4.47E-07 3.17E-09 9

S 1.1 1.30E-06 1.29E-06 1.12E-06 6.63E-09 10 SSW 1.2 1.98E-06 1.96E-06 1.70E-06 6.34E-09 11 SW 1.9 2.03E-06 2.00E-06 1.68E-06 3.41E-09 12 WSW 1.3 1.24E-05 1.23E-05 1.06E-05 1.57E-08 13 W

1.2 6.95E-06 6.88E-06 5.97E-06 8.47E-09 14 NWW (1) 15 NW 1.8 2.03E-06 2.01E-06 1.69E-06 3.63E-09 16 NNW 4

4.02E-07 3.91E-07 3.05E-07 6.48E-10 (1) No garden within 5 miles for this sector

  • Locations use the 2003 Land Use Census Locations

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-122 2002 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST RESIDENCE AND GARDEN*

NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 1.3 2.06E-06 2.04E-06 1.76E-06 5.79E-09 2

NNE 1

3.26E-06 3.25E-06 2.84E-06 1.29E-08 3

NE 0.9 2.78E-06 2.77E-06 2.44E-06 1.99E-08 4

ENE 2.1 4.18E-07 4.15E-07 3.43E-07 3.05E-09 5

E 1.4 3.55E-07 3.53E-07 3.02E-07 2.30E-09 6

ESE 0.5 1.30E-06 1.30E-06 1.19E-06 1.07E-08 7

SE 0.5 1.67E-06 1.67E-06 1.53E-06 1.46E-08 8

SSE 0.6 1.96E-06 1.95E-06 1.76E-06 1.60E-08 9

S 1

1.45E-06 1.44E-06 1.26E-06 7.63E-09 10 SSW 0.9 3.73E-06 3.71E-06 3.27E-06 1.28E-08 11 SW 1.5 3.03E-06 3.00E-06 2.56E-06 5.50E-09 12 WSW 1.3 1.14E-05 1.13E-05 9.74E-06 1.33E-08 13 W

1.2 5.41E-06 5.36E-06 4.65E-06 6.70E-09 14 WNW 0.8 7.00E-06 6.95E-06 6.19E-06 1.12E-08 15 NW 0.8 5.92E-06 5.88E-06 5.23E-06 1.28E-08 16 NNW 0.6 6.47E-06 6.45E-06 5.84E-06 1.74E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 3.2 5.51E-07 5.42E-07 4.31E-07 1.30E-09 2

NNE 2.3 9.70E-07 9.61E-07 7.90E-07 3.39E-09 3

NE 2.7 5.50E-07 5.45E-07 4.41E-07 3.44E-09 4

ENE 2.1 4.18E-07 4.15E-07 3.43E-07 3.05E-09 5

E 1.8 2.38E-07 2.37E-07 1.99E-07 1.52E-09 6

ESE 2.5 8.95E-08 8.89E-08 7.24E-08 5.74E-10 7

SE 0.6 1.28E-06 1.28E-06 1.15E-06 1.07E-08 8

SSE 1.5 4.46E-07 4.44E-07 3.78E-07 3.02E-09 9

S 1.1 1.25E-06 1.24E-06 1.08E-06 6.42E-09 10 SSW 1.2 2.40E-06 2.39E-06 2.07E-06 7.71E-09 11 SW 1.9 2.13E-06 2.11E-06 1.76E-06 3.76E-09 12 WSW 1.3 1.14E-05 1.13E-05 9.74E-06 1.33E-08 13 W

1.2 5.41E-06 5.36E-06 4.65E-06 6.70E-09 14 NWW (1) 15 NW 1.8 1.65E-06 1.63E-06 1.38E-06 3.05E-09 16 NNW 4

3.82E-07 3.73E-07 2.90E-07 6.46E-10 (1) No garden within 5 miles for this sector

  • Locations use the 2003 Land Use Census Locations

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-123 2003 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST RESIDENCE AND GARDEN*

NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 1.3 1.89E-06 1.87E-06 1.61E-06 5.20E-09 2

NNE 1

2.85E-06 2.83E-06 2.48E-06 1.06E-08 3

NE 0.9 2.56E-06 2.55E-06 2.25E-06 1.74E-08 4

ENE 2.1 4.35E-07 4.32E-07 3.57E-07 3.02E-09 5

E 1.4 3.53E-07 3.51E-07 3.01E-07 2.19E-09 6

ESE 0.5 1.33E-06 1.33E-06 1.21E-06 1.12E-08 7

SE 0.5 1.66E-06 1.66E-06 1.52E-06 1.42E-08 8

SSE 0.6 1.68E-06 1.67E-06 1.51E-06 1.40E-08 9

S 1

1.20E-06 1.20E-06 1.05E-06 5.99E-09 10 SSW 0.9 3.92E-06 3.90E-06 3.44E-06 1.37E-08 11 SW 1.5 3.91E-06 3.88E-06 3.31E-06 7.30E-09 12 WSW 1.3 1.00E-05 9.93E-06 8.56E-06 1.30E-08 13 W

1.2 4.96E-06 4.91E-06 4.26E-06 6.68E-09 14 WNW 0.8 6.33E-06 6.29E-06 5.59E-06 1.24E-08 15 NW 0.8 7.72E-06 7.67E-06 6.82E-06 1.86E-08 16 NNW 0.6 5.96E-06 5.94E-06 5.37E-06 1.78E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 3.2 4.97E-07 4.89E-07 3.89E-07 1.17E-09 2

NNE 2.3 8.48E-07 8.39E-07 6.90E-07 2.79E-09 3

NE 2.7 5.08E-07 5.04E-07 4.07E-07 3.01E-09 4

ENE 2.1 4.35E-07 4.32E-07 3.57E-07 3.02E-09 5

E 1.8 2.38E-07 2.37E-07 1.99E-07 1.45E-09 6

ESE 2.5 8.98E-08 8.92E-08 7.27E-08 6.03E-10 7

SE 0.6 1.27E-06 1.27E-06 1.15E-06 1.04E-08 8

SSE 1.5 3.88E-07 3.86E-07 3.29E-07 2.65E-09 9

S 1.1 1.03E-06 1.03E-06 8.95E-07 5.04E-09 10 SSW 1.2 2.53E-06 2.52E-06 2.18E-06 8.24E-09 11 SW 1.9 2.75E-06 2.72E-06 2.28E-06 4.98E-09 12 WSW 1.3 1.00E-05 9.93E-06 8.56E-06 1.30E-08 13 W

1.2 4.96E-06 4.91E-06 4.26E-06 6.68E-09 14 NWW 15 NW 1.8 2.18E-06 2.16E-06 1.82E-06 4.44E-09 16 NNW 4

3.42E-07 3.34E-07 2.60E-07 6.60E-10 (1) No garden within 5 miles for this sector

  • Locations use the 2003 Land Use Census Locations

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-124 1999 - 2003 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST RESIDENCE AND GARDEN*

NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 1.3 2.00E-06 1.99E-06 1.71E-06 5.27E-09 2

NNE 1

3.05E-06 3.03E-06 2.65E-06 1.10E-08 3

NE 0.9 2.86E-06 2.85E-06 2.51E-06 1.81E-08 4

ENE 2.1 3.95E-07 3.92E-07 3.24E-07 2.92E-09 5

E 1.4 3.30E-07 3.28E-07 2.81E-07 2.16E-09 6

ESE 0.5 1.30E-06 1.30E-06 1.19E-06 1.04E-08 7

SE 0.5 1.92E-06 1.92E-06 1.75E-06 1.58E-08 8

SSE 0.6 2.05E-06 2.05E-06 1.85E-06 1.64E-08 9

S 1

1.48E-06 1.48E-06 1.29E-06 7.84E-09 10 SSW 0.9 3.53E-06 3.51E-06 3.09E-06 1.25E-08 11 SW 1.5 3.24E-06 3.21E-06 2.74E-06 6.15E-09 12 WSW 1.3 1.14E-05 1.13E-05 9.70E-06 1.43E-08 13 W

1.2 5.84E-06 5.79E-06 5.02E-06 7.43E-09 14 WNW 0.8 6.73E-06 6.68E-06 5.94E-06 1.13E-08 15 NW 0.8 6.77E-06 6.72E-06 5.98E-06 1.46E-08 16 NNW 0.6 6.04E-06 6.01E-06 5.44E-06 1.60E-08 NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 1

N 3.2 5.34E-07 5.24E-07 4.17E-07 1.19E-09 2

NNE 2.3 9.07E-07 8.98E-07 7.39E-07 2.88E-09 3

NE 2.7 5.72E-07 5.67E-07 4.59E-07 3.13E-09 4

ENE 2.1 3.95E-07 3.92E-07 3.24E-07 2.92E-09 5

E 1.8 2.22E-07 2.21E-07 1.85E-07 1.43E-09 6

ESE 2.5 8.76E-08 8.70E-08 7.09E-08 5.60E-10 7

SE 0.6 1.47E-06 1.47E-06 1.32E-06 1.16E-08 8

SSE 1.5 4.70E-07 4.68E-07 3.98E-07 3.10E-09 9

S 1.1 1.27E-06 1.27E-06 1.10E-06 6.60E-09 10 SSW 1.2 2.27E-06 2.26E-06 1.95E-06 7.55E-09 11 SW 1.9 2.28E-06 2.25E-06 1.89E-06 4.20E-09 12 WSW 1.3 1.14E-05 1.13E-05 9.70E-06 1.43E-08 13 W

1.2 5.84E-06 5.79E-06 5.02E-06 7.43E-09 14 NWW (1) 15 NW 1.8 1.90E-06 1.88E-06 1.58E-06 3.49E-09 16 NNW 4

3.50E-07 3.41E-07 2.65E-07 5.94E-10 (1) No garden within 5 miles for this sector

  • Locations use the 2003 Land Use Census Locations

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-125 1999 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST MEAT ANIMAL. DAIRY LOCATIONS AND SPECIAL RECEPTORS*

ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 2

NNE 2.3 8.50E-07 8.40E-07 6.92E-07 2.73E-09 4

ENE 2.4 3.37E-07 3.35E-07 2.74E-07 2.55E-09 5

E 1.4 3.28E-07 3.27E-07 2.80E-07 2.30E-09 10 SSW 3

4.70E-07 4.63E-07 3.71E-07 1.58E-09 10 SSW 3.5 3.30E-07 3.25E-07 2.56E-07 1.05E-09 12 WSW 1.7 7.90E-06 7.82E-06 6.61E-06 9.71E-09 15 NW 1.8 1.71E-06 1.69E-06 1.43E-06 3.19E-09 ALL DAIRY LOCATIONS WITHIN A 5-MILE RADIUS OF SSES SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 5

E 4.5 4.62E-08 4.56E-08 3.46E-08 2.66E-10 6

ESE 2.7 6.54E-08 6.50E-08 5.24E-08 4.19E-10 6

ESE 4.2 2.64E-08 2.61E-08 2.00E-08 1.49E-10 10 SSW 3

4.70E-07 4.63E-07 3.71E-07 1.58E-09 10 SSW 3.1 4.37E-07 4.31E-07 3.43E-07 1.46E-09 10 SSW 3.5 3.30E-07 3.25E-07 2.56E-07 1.05E-09 12 WSW 1.7 7.90E-06 7.82E-06 6.61E-06 9.71E-09 13 W

5 5.49E-07 5.28E-07 4.03E-07 4.36E-10 16 NNW 4.2 2.69E-07 2.62E-07 2.03E-07 4.68E-10 SPECIAL RECEPTOR LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 3 NE Riverlands / EIC 0.7 4.40E-06 4.39E-06 3.93E-06 2.70E-08 12 WSW Towers Club 0.5 4.06E-05 4.05E-05 3.71E-05 5.97E-08 5

E East Gate 0.5 1.70E-06 1.70E-06 1.55E-06 1.48E-08

  • Locations use the 2003 Land Use Census Locations (1)

Relative concentration (sec/m

3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m

3)

(3)

Decayed and depleted, half-life 8 days (sec/m

3)

(4)

Relative deposition rate (l/m

2)

I I

I I

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-126 2000 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST MEAT ANIMAL, DAIRY LOCATIIONS AND SPECIAL RECEPTORS*

ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 2

NNE 2.3 9.52E-07 9.41E-07 7.75E-07 2.74E-09 4

ENE 2.4 3.04E-07 3.02E-07 2.47E-07 2.26E-09 5

E 1.4 3.42E-07 3.40E-07 2.91E-07 2.17E-09 10 SSW 3

5.36E-07 5.28E-07 4.23E-07 1.43E-09 10 SSW 3.5 3.77E-07 3.70E-07 2.92E-07 9.52E-10 12 WSW 1.7 7.71E-06 7.63E-06 6.45E-06 9.69E-09 15 NW 1.8 1.93E-06 1.91E-06 1.61E-06 3.15E-09 ALL DAIRY LOCATIONS WITHIN A 5-MILE RAIDUS OF SSES SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 5

E 4.5 4.78E-08 4.70E-08 3.58E-08 2.51E-10 6

ESE 2.7 8.98E-08 8.90E-08 7.20E-08 5.58E-10 6

ESE 4.2 3.60E-08 3.55E-08 2.72E-08 1.99E-10 10 SSW 3

5.36E-07 5.28E-07 4.23E-07 1.43E-09 10 SSW 3.1 4.99E-07 4.91E-07 3.92E-07 1.32E-09 10 SSW 3.5 3.77E-07 3.70E-07 2.92E-07 9.52E-10 12 WSW 1.7 7.71E-06 7.63E-06 6.45E-06 9.69E-09 13 W

5 5.35E-07 5.15E-07 3.93E-07 4.49E-10 16 NNW 4.2 3.15E-07 3.06E-07 2.37E-07 4.68E-10 SPECIAL RECEPTOR LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 3 NE Riverlands/EIC 0.7 4.17E-06 4.16E-06 3.73E-06 2.61E-08 12 WSW Towers Club 0.5 3.88E-05 3.87E-05 3.54E-05 5.96E-08 5

E East Gate 0.5 1.79E-06 1.79E-06 1.63E-06 1.39E-08

  • Locations use the 2003 Land Use Census Locations. Only sectors with animals or dairy within 5 miles are shown.

(1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-127 2001 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST MEAT ANIMAL, DAIRY LOCATIIONS AND SPECIAL RECEPTORS*

ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 2

NNE 2.3 9.17E-07 9.06E-07 7.46E-07 2.75E-09 4

ENE 2.4 2.93E-07 2.91E-07 2.38E-07 2.30E-09 5

E 1.4 2.71E-07 2.70E-07 2.31E-07 1.85E-09 10 SSW 3

4.46E-07 4.39E-07 3.52E-07 1.24E-09 10 SSW 3.5 3.13E-07 3.08E-07 2.42E-07 8.22E-10 12 WSW 1.7 8.49E-06 8.40E-06 7.10E-06 1.02E-08 15 NW 1.8 2.03E-06 2.01E-06 1.69E-06 3.63E-09 ALL DAIRY LOCATIONS WITHIN A 5-MILE RADIUS OF SSES SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 5

E 4.5 3.70E-08 3.64E-08 2.77E-08 2.14E-10 6

ESE 2.7 6.77E-08 6.71E-08 5.42E-08 3.93E-10 6

ESE 4.2 2.71E-08 2.67E-08 2.05E-08 1.40E-10 10 SSW 3

4.46E-07 4.39E-07 3.52E-07 1.24E-09 10 SSW 3.1 4.15E-07 4.08E-07 3.26E-07 1.14E-09 10 SSW 3.5 3.13E-07 3.08E-07 2.42E-07 8.22E-10 12 WSW 1.7 8.49E-06 8.40E-06 7.10E-06 1.02E-08 13 W

5 6.35E-07 6.11E-07 4.66E-07 4.89E-10 16 NNW 4.2 3.76E-07 3.66E-07 2.84E-07 5.95E-10 SPECIAL RECEPTOR LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 3 NE Riverlands/EIC 0.7 4.34E-06 4.33E-06 3.87E-06 2.77E-08 12 WSW Towers Club 0.5 4.29E-05 4.28E-05 3.92E-05 6.28E-08 5

E East Gate 0.5 1.42E-06 1.42E-06 1.30E-06 1.19E-08

  • Locations use the 2003 Land Use Census Locations. Only sectors with animals or dairy within 5 miles are shown (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-128 2002 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST MEAT ANIMAL, DAIRY LOCATIIONS AND SPECIAL RECEPTORS*

ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 2

NNE 2.3 9.70E-07 9.61E-07 7.90E-07 3.39E-09 4

ENE 2.4 3.48E-07 3.45E-07 2.82E-07 2.54E-09 5

E 1.4 3.55E-07 3.53E-07 3.02E-07 2.30E-09 10 SSW 3

5.49E-07 5.40E-07 4.33E-07 1.50E-09 10 SSW 3.5 3.87E-07 3.80E-07 2.99E-07 1.00E-09 12 WSW 1.7 7.78E-06 7.70E-06 6.51E-06 8.69E-08 15 NW 1.8 1.65E-06 1.63E-06 1.38E-06 3.05E-09 ALL DAIRY LOCATIONS WITHIN A 5-MILE RADIUS OF SSES SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 5

E 4.5 4.86E-08 4.79E-08 3.64E-08 2.66E-10 6

ESE 2.7 7.72E-08 7.66E-08 6.19E-08 4.85E-10 6

ESE 4.2 3.11E-08 3.07E-08 2.36E-08 1.72E-10 10 SSW 3

5.49E-07 5.40E-07 4.33E-07 1.50E-09 10 SSW 3.1 5.11E-07 5.03E-07 4.01E-07 1.38E-09 10 SSW 3.5 3.87E-07 3.80E-07 2.99E-07 1.00E-09 12 WSW 1.7 7.78E-06 7.70E-06 6.51E-06 8.69E-09 13 W

5 4.98E-07 4.78E-07 3.65E-07 3.87E-10 16 NNW 4.2 3.58E-07 3.49E-07 2.70E-07 5.93E-10 SPECIAL RECEPTOR LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 3 NE Riverlands / EIC 0.7 4.03E-06 4.02E-06 3.60E-06 3.03E-08 12 WSW Towers Club 0.5 3.97E-05 3.96E-05 3.63E-05 5.34E-08 5

E East Gate 0.5 1.82E-06 1.82E-06 1.67E-06 1.48E-08

  • Locations use the 2003 Land Use Census Locations. Only sectors with animals or dairy within 5 miles are shown.

(1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-129 2003 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST MEAT ANIMAL, DAIRY LOCATIIONS AND SPECIAL RECEPTORS*

ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 2

NNE 2.3 8.48E-07 8.39E-07 6.90E-07 2.79E-09 4

ENE 2.4 3.62E-07 3.60E-07 2.94E-07 2.52E-09 5

E 1.4 3.53E-07 3.51E-07 3.01E-07 2.19E-09 10 SSW 3

5.71E-07 5.63E-07 4.51E-07 1.61E-09 10 SSW 3.5 4.00E-07 3.94E-07 3.10E-07 1.07E-09 12 WSW 1.7 6.85E-06 6.77E-06 5.73E-06 8.50E-09 15 NW 1.8 2.18E-06 2.16E-06 1.82E-06 4.44E-09 ALL DAIRY LOCATIONS NEAR SSES SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 5

E 4.5 4.99E-08 4.90E-08 3.73E-08 2.53E-10 6

ESE 2.7 7.74E-08 7.67E-08 6.20E-08 5.09E-10 6

ESE 4.2 3.10E-08 3.06E-08 2.35E-08 1.81E-10 10 SSW 3

5.71E-07 5.63E-07 4.51E-07 1.61E-09 10 SSW 3.1 5.30E-07 5.23E-07 4.17E-07 1.48E-09 10 SSW 3.5 4.00E-07 3.94E-07 3.10E-07 1.07E-09 12 WSW 1.7 6.85E-06 6.77E-06 5.73E-06 8.50E-09 13 W

5 4.42E-07 4.25E-07 3.25E-07 3.86E-10 16 NNW 4.2 3.20E-07 3.13E-07 2.42E-07 6.07E-10 SPECIAL RECEPTOR LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 3 NE Riverlands / EIC 0.7 3.70E-06 3.69E-06 3.30E-06 2.65E-08 12 WSW Towers Club 0.5 3.41E-05 3.40E-05 3.11E-05 5.22E-08 5

E East Gate 0.5 1.82E-06 1.81E-06 1.66E-06 1.41E-08

  • Locations use the 2003 Land Use Census Locations (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

SSES - FSAR Table Rev 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-130 1999 - 2003 ATMOSPHERIC DISPERSION ESTIMATES FOR NEAREST MEAT ANIMAL, DAIRY LOCATIIONS AND SPECIAL RECEPTORS*

ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 2

NNE 2.3 9.07E-07 8.98E-07 7.39E-07 2.88E-09 4

ENE 2.4 3.29E-07 3.26E-07 2.67E-07 2.43E-09 5

E 1.4 3.30E-07 3.28E-07 2.81E-07 2.16E-09 10 SSW 3

5.14E-07 5.07E-07 4.06E-07 1.47E-09 10 SSW 3.5 3.61E-07 3.55E-07 2.80E-07 9.79E-10 12 WSW 1.7 7.75E-06 7.66E-06 6.48E-06 9.36E-09 15 NW 1.8 1.90E-06 1.88E-06 1.58E-06 3.49E-09 ALL DAIRY LOCATIONS NEAR SSES SECTOR NUMBER AFFECTED SECTOR MILES X/Q X/Q DEC X/Q DEC+DEP DEPOSITION 5

E 4.5 4.59E-08 4.52E-08 3.44E-08 2.50E-10 6

ESE 2.7 7.55E-08 7.49E-08 6.05E-08 4.73E-10 6

ESE 4.2 3.03E-08 2.99E-08 2.29E-08 1.68E-10 10 SSW 3

5.14E-07 5.07E-07 4.06E-07 1.47E-09 10 SSW 3.1 4.78E-07 4.71E-07 3.76E-07 1.35E-09 10 SSW 3.5 3.61E-07 3.55E-07 2.80E-07 9.79E-10 12 WSW 1.7 7.75E-06 7.66E-06 6.48E-06 9.36E-09 13 W

5 5.32E-07 5.12E-07 3.90E-07 4.29E-10 16 NNW 4.2 3.28E-07 3.19E-07 2.47E-07 5.46E-10 SPECIAL RECEPTOR LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 3 NE Riverlands / EIC 0.7 4.13E-06 4.12E-06 3.69E-06 2.75E-08 12 WSW Towers Club 0.5 3.92E-05 3.91E-05 3.58E-05 5.75E-08 5

E East Gate 0.5 1.71E-06 1.71E-06 1.56E-06 1.39E-08

  • Locations use the 2003 Land Use Census Locations. Only sectors with animals or dairy within 5 miles are shown.

(1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

I

SSES - FSAR Table Rev 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-131 1999 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 12 WSW Maximum (X/Q) Site Boundary 1.22 1.28E-05 1.27E-05 1.10E-05 1.66E-08 9

S Closest (X/Q) Site Boundary 0.38 6.71E-06 6.70E-06 6.25E-06 4.66E-08 12 WSW Maximum (X/Q) Residence 1.3 1.16E-05 1.15E-05 9.90E-06 1.49E-08 3

NE Maximum (D/Q) Residence 0.9 3.07E-06 3.05E-06 2.69E-06 1.77E-08 12 WSW Maximum (D/Q) Garden 1.3 1.15E-05 9.90E-06 1.49E-08 1.16E-05 12 WSW Maximum (D/Q) Dairy 1.7 7.90E-06 7.82E-06 6.61E-06 9.71E-09 12 WSW Maximum (D/Q) Meat Producer 1.7 7.90E-06 7.82E-06 6.61E-06 9.71E-09 3

NE Riverlands / EIC 0.7 4.40E-06 4.39E-06 3.93E-06 2.70E-08 12 WSW Towers Club 0.5 4.06E-05 4.05E-05 3.71E-05 5.97E-08 5

E East Gate 0.5 1.70E-06 1.70E-06 1.55E-06 1.48E-08 (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-132 2000 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS SECTOR NUMBER AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 12 WSW Maximum (X/Q) Site Boundary 1.22 1.24E-05 1.23E-05 1.07E-05 1.65E-08 9

S Closest (X/Q) Site Boundary 0.38 6.21E-06 6.20E-06 5.78E-06 4.11E-08 12 WSW Maximum (X/Q) Residence 1.3 1.13E-05 1.12E-05 9.65E-06 1.49E-08 3

NE Maximum (D/Q) Residence 0.6 2.44E-06 2.44E-06 2.20E-06 1.94E-08 12 WSW Maximum (D/Q) Garden 1.3 1.13E-05 1.12E-05 9.65E-06 1.49E-08 12 WSW Maximum (D/Q) Dairy 1.7 7.71E-06 7.63E-06 6.45E-06 9.69E-09 12 WSW Maximum (D/Q) Meat Producer 1.7 7.71E-06 7.63E-06 6.45E-06 9.69E-09 3

NE Riverlands / EIC 0.7 4.17E-06 4.16E-06 3.73E-06 2.61E-08 12 WSW Towers Club 0.5 3.88E-05 3.87E-05 3.54E-05 5.96E-08 5

E East Gate 0.5 1.79E-06 1.79E-06 1.63E-06 1.39E-08 (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

SSES - FSAR Table Rev. 49 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-133 2001 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 12/WSW Maximum (X/Q) Site Boundary 1.22 1.37E-05 1.36E-05 1.18E-05 1.74E-08 9/S Closest (X/Q) Site Boundary 0.38 6.07E-06 6.06E-06 5.65E-06 3.90E-08 12/WSW Maximum (X/Q) Residence 1.3 1.24E-05 1.23E-05 1.06E-05 1.57E-08 3/NE Maximum (D/Q) Residence 0.9 3.00E-06 2.99E-06 2.63E-06 1.82E-08 12/WSW Maximum (D/Q) Garden 1.3 1.24E-05 1.23E-05 1.06E-05 1.57E-08 12/SW Maximum (D/Q) Dairy 1.7 8.49E-06 8.40E-06 7.10E-06 1.02E-08 12/WSW Maximum (D/Q) Meat Producer 1.7 8.49E-06 8.40E-06 7.10E-06 1.02E-08 3/NE Riverlands / EIC 0.7 4.34E-06 4.33E-06 3.87E-06 2.77E-08 12/WSW Towers Club 0.5 4.29E-05 4.28E-05 3.92E-05 6.28E-08 5/E East Gate 0.5 1.42E-06 1.42E-06 1.30E-06 1.19E-08 (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

I I

I I

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-134 2002 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 12/WSW Maximum (X/Q) Site Boundary 1.22 1.26E-05 1.25E-05 1.08E-05 1.48E-08 9/S Closest (X/Q) Site Boundary 0.38 5.71E-06 5.70E-06 5.31E-06 3.78E-08 12/WSW Maximum (X/Q) Residence 1.3 1.14E-05 1.13E-05 9.74E-06 1.33E-08 3/NE Maximum (D/Q) Residence 0.9 2.78E-06 2.77E-06 2.44E-06 1.99E-08 12/WSW Maximum (D/Q) Garden 1.3 1.14E-05 1.13E-05 9.74E-06 1.33E-08 12/SW Maximum (D/Q) Dairy 1.7 7.78E-06 7.70E-06 6.51E-06 8.69E-09 12/WSW Maximum (D/Q) Meat Producer 1.7 7.78E-06 7.70E-06 6.51E-06 8.69E-09 3/NE Riverlands / EIC 0.7 4.03E-06 4.02E-06 3.60E-06 3.03E-08 12/WSW Towers Club 0.5 3.97E-05 3.96E-05 3.63E-05 5.34E-08 5/E East Gate 0.5 1.82E-06 1.82E-06 1.67E-06 1.48E-08 (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

I I

I I

I

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-135 2003 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 11WS Maximum (X/Q) Site Boundary 0.61 1.45E-05 1.45E-05 1.31E-05 3.25E-08 9/S Closest (X/Q) Site Boundary 0.38 4.69E-06 4.69E-06 4.37E-06 2.97E-08 12/WSW Maximum (X/Q) Residence 1.3 1.00E-05 9.93E-06 8.56E-06 1.30E-08 15/NW Maximum (D/Q) Residence 0.8 7.72E-06 7.67E-06 6.82E-06 1.86E-08 12/WSW Maximum (D/Q) Garden 1.3 1.00E-05 9.93E-06 8.56E-06 1.30E-08 12/SW Maximum (D/Q) Dairy 1.7 6.85E-06 6.77E-06 5.73E-06 8.50E-09 12/WSW Maximum (D/Q) Meat Producer 1.7 6.85E-06 6.77E-06 5.73E-06 8.50E-09 3/NE Riverlands / EIC 0.7 3.70E-06 3.69E-06 3.30E-06 2.65E-08 12/WSW Towers Club 0.5 3.41E-05 3.40E-05 3.11E-05 5.22E-08 5/E East Gate 0.5 1.82E-06 1.81E-06 1.66E-06 1.41E-08 (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

I I

I I

I

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-136 1999 - 2003 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS AFFECTED SECTOR LOCATION MILES X/Q(1)

X/Q DEC(2)

X/Q DEC+DEP(3)

DEPOSITION(4) 12/WSW Maximum (X/Q) Site Boundary 1.22 1.25E-05 1.24E-05 1.07E-05 1.60E-08 9/S Closest (X/Q) Site Boundary 0.38 5.88E-06 5.87E-06 5.47E-06 3.88E-08 12/WSW Maximum (X/Q) Residence 1.3 1.14E-05 1.13E-05 9.70E-06 1.43E-08 3/NE Maximum (D/Q) Residence 0.9 2.86E-06 2.85E-06 2.51E-06 1.81E-08 12/WSW Maximum (D/Q) Garden 1.3 1.14E-05 1.13E-05 9.70E-06 1.43E-08 12/WSW Maximum (D/Q) Dairy 1.7 7.75E-06 7.66E-06 6.48E-06 9.36E-09 12/WSW Maximum (D/Q) Meat Producer 1.7 7.75E-06 7.66E-06 6.48E-06 9.36E-09 3/NE Riverlands / EIC 0.7 4.13E-06 4.12E-06 3.69E-06 2.75E-08 12/WSW Towers Club 0.5 3.92E-05 3.91E-05 3.58E-05 5.75E-08 5/E East Gate 0.5 1.71E-06 1.71E-06 1.56E-06 1.39E-08 (1)

Relative concentration (sec/m3)

(2)

Decayed and undepleted, half-life 2.26 days (sec/m3)

(3)

Decayed and depleted, half-life 8 days (sec/m3)

(4)

Relative deposition rate (1/m2)

I I

I I

I I

I I

I

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-137 1999-2003 SSES RELATIVE CONCENTRATIONS NO DECAY, UNDEPLETED X/Q X/Q ACCUMULATION FOR GROUND AVERAGE (seconds per cubic meter)

Direction From 0.5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 N

4.13E-06 7.83E-07 3.25E-07 1.71E-07 1.10E-07 4.05E-08 1.11E-08 5.34E-09 3.35E-09 2.37E-09 NNE 8.11E-06 1.63E-06 7.28E-07 3.91E-07 2.53E-07 9.40E-08 2.59E-08 1.27E-08 8.10E-09 5.80E-09 NE 1.71E-05 3.22E-06 1.47E-06 8.32E-07 5.51E-07 2.18E-07 6.61E-08 3.32E-08 2.14E-08 1.55E-08 ENE 4.96E-05 9.15E-06 4.48E-06 2.66E-06 1.78E-06 7.05E-07 2.06E-07 9.99E-08 6.47E-08 4.76E-08 E

2.24E-05 4.08E-06 1.80E-06 1.02E-06 6.83E-07 2.78E-07 8.81E-08 4.46E-08 2.88E-08 2.10E-08 ESE 1.27E-05 2.45E-06 1.11E-06 6.23E-07 4.13E-07 1.67E-07 4.64E-08 2.04E-08 1.31E-08 9.49E-09 SE 1.26E-05 2.48E-06 1.13E-06 6.41E-07 4.25E-07 1.74E-07 4.35E-08 1.61E-08 1.03E-08 7.42E-09 SSE 9.08E-06 1.77E-06 7.87E-07 4.42E-07 2.98E-07 1.28E-07 3.37E-08 1.21E-08 7.71E-09 5.55E-09 S

7.81E-06 1.65E-06 8.08E-07 4.70E-07 3.23E-07 1.50E-07 4.18E-08 1.44E-08 9.23E-09 6.63E-09 SSW 8.36E-06 1.69E-06 7.78E-07 4.42E-07 2.94E-07 1.22E-07 3.21E-08 1.23E-08 7.80E-09 5.59E-09 SW 6.65E-06 1.34E-06 6.36E-07 3.65E-07 2.45E-07 1.08E-07 2.80E-08 9.42E-09 5.96E-09 4.23E-09 WSW 3.41E-06 6.56E-07 3.05E-07 1.79E-07 1.23E-07 5.80E-08 1.82E-08 6.82E-09 3.49E-09 1.91E-09 W

1.58E-06 2.99E-07 1.30E-07 7.11E-08 4.67E-08 1.91E-08 5.18E-09 2.10E-09 1.31E-09 9.15E-10 WNW 1.20E-06 2.19E-07 8.80E-08 4.60E-08 2.93E-08 1.08E-08 2.93E-09 1.39E-09 8.58E-10 5.96E-10 NW 2.03E-06 3.78E-07 1.50E-07 7.66E-08 4.86E-08 1.75E-08 4.62E-09 2.18E-09 1.34E-09 9.32E-10 NNW 2.58E-06 4.83E-07 2.04E-07 1.08E-07 6.83E-08 2.38E-08 5.94E-09 2.82E-09 1.75E-09 1.22E-09

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-138 1999-2003 SSES RELATIVE CONCENTRATIONS, 2.26-DAY DECAY UNDEPLETED X/Q X/Q ACCUMULATION FOR GROUND DECAYED SECTOR AVERAGE (seconds per cubic meter)

MILES Direction From 0.5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 N

4.13E-06 7.79E-07 3.22E-07 1.69E-07 1.08E-07 3.94E-08 1.04E-08 4.84E-09 2.92E-09 1.98E-09 NNE 8.09E-06 1.62E-06 7.19E-07 3.84E-07 2.47E-07 9.06E-08 2.40E-08 1.12E-08 6.80E-09 4.63E-09 NE 1.71E-05 3.19E-06 1.45E-06 8.15E-07 5.37E-07 2.08E-07 6.03E-08 2.85E-08 1.73E-08 1.18E-08 ENE 4.95E-05 9.06E-06 4.41E-06 2.60E-06 1.73E-06 6.72E-07 1.87E-07 8.55E-08 5.21E-08 3.60E-08 E

2.23E-05 4.03E-06 1.77E-06 9.95E-07 6.60E-07 2.62E-07 7.85E-08 3.69E-08 2.21E-08 1.49E-08 ESE 1.26E-05 2.43E-06 1.09E-06 6.06E-07 3.99E-07 1.57E-07 4.12E-08 1.67E-08 9.93E-09 6.65E-09 SE 1.26E-06 2.45E-06 1.11E-06 6.25E-07 4.12E-07 1.64E-07 3.90E-08 1.34E-08 7.95E-09 5.33E-09 SSE 9.05E-06 1.75E-06 7.75E-07 4.33E-07 2.89E-07 1.22E-07 3.06E-08 1.03E-08 6.16E-09 4.16E-09 S

7.79E-06 1.64E-06 7.97E-07 4.61E-07 3.15E-07 1.44E-07 3.84E-08 1.26E-08 7.59E-09 5.16E-09 SSW 8.34E-06 1.68E-06 7.69E-07 4.35E-07 2.88E-07 1.18E-07 2.99E-08 1.09E-08 6.64E-09 4.54E-09 SW 6.64E-06 1.33E-06 6.31E-07 3.61E-07 2.41E-07 1.05E-07 2.65E-08 8.60E-09 5.25E-09 3.59E-09 WSW 3.41E-06 6.53E-07 3.03E-07 1.78E-07 1.21E-07 5.67E-08 1.73E-08 6.30E-09 3.13E-09 1.66E-09 W

1.58E-06 2.98E-07 1.29E-07 7.03E-08 4.60E-08 1.86E-08 4.91E-09 1.92E-09 1.16E-09 7.79E-10 WNW 1.20E-06 2.18E-07 8.73E-08 4.55E-08 2.89E-08 1.06E-08 2.80E-09 1.28E-09 7.67E-10 5.16E-10 NW 2.03E-06 3.76E-07 1.49E-07 7.58E-08 4.80E-08 1.72E-08 4.42E-09 2.03E-09 1.22E-09 8.19E-10 NNW 2.57E-06 4.81E-07 2.02E-07 1.07E-07 6.74E-08 2.33E-08 5.67E-09 2.61E-09 1.57E-09 1.06E-09

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-139 1999-2003 SSES RELATIVE CONCENTRATIONS 8-DAY DECAY, DEPLETED X/Q X/Q ACCUMULATION FOR DECAYED DEPLETION (seconds per cubic meter)

MILES Direction From 0.5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 N

3.78E-06 6.63E-07 2.63E-07 1.33E-07 8.22E-08 2.82E-08 6.81E-09 2.87E-09 1.61E-09 1.03E-09 NNE 7.41E-06 1.38E-06 5.88E-07 3.02E-07 1.89E-07 6.52E-08 1.59E-08 6.80E-09 3.86E-09 2.50E-09 NE 1.56E-05 2.73E-06 1.19E-06 6.43E-07 4.12E-07 1.51E-07 4.04E-08 1.76E-08 1.01E-08 6.61E-09 ENE 4.53E-05 7.74E-06 3.61E-06 2.05E-06 1.33E-06 4.88E-07 1.25E-07 5.28E-08 3.05E-08 2.02E-08 E

2.04E-05 3.45E-06 1.46E-06 7.89E-07 5.09E-07 1.92E-07 5.34E-08 2.34E-08 1.34E-08 8.78E-09 ESE 1.16E-05 2.07E-06 8.96E-07 4.80E-07 3.08E-07 1.15E-07 2.81E-08 1.07E-08 6.07E-09 3.94E-09 SE 1.15E-05 2.10E-06 9.15E-07 4.95E-07 3.17E-07 1.20E-07 2.64E-08 8.44E-09 4.79E-09 3.10E-09 SSE 8.29E-06 1.50E-06 6.35E-07 3.42E-07 2.22E-07 8.87E-08 2.05E-08 6.38E-09 3.62E-09 2.35E-09 S

7.13E-06 1.40E-06 6.53E-07 3.64E-07 2.41E-07 1.04E-07 2.56E-08 7.67E-09 4.37E-09 2.84E-09 SSW 7.63E-06 1.43E-06 6.29E-07 3.42E-07 2.20E-07 8.50E-08 1.97E-08 6.55E-09 3.73E-09 2.42E-09 SW 6.07E-06 1.13E-06 5.15E-07 2.83E-07 1.84E-07 7.50E-08 1.72E-08 5.07E-09 2.88E-09 1.86E-09 WSW 3.12E-06 5.56E-07 2.47E-07 1.39E-07 9.20E-08 4.04E-08 1.12E-08 3.68E-09 1.69E-09 8.43E-10 W

1.45E-06 2.54E-07 1.05E-07 5.51E-08 3.50E-08 1.33E-08 3.20E-09 1.13E-09 6.33E-10 4.01E-10 WNW 1.10E-06 1.86E-07 7.12E-08 3.57E-08 2.20E-08 7.53E-09 1.81E-09 7.49E-10 4.16E-10 2.63E-10 NW 1.86E-06 3.20E-07 1.22E-07 5.94E-08 3.64E-08 1.22E-08 2.86E-09 1.18E-09 6.54E-10 4.13E-10 NNW 2.35E-06 4.09E-07 1.65E-07 8.40E-08 5.12E-08 1.66E-08 3.67E-09 1.52E-09 8.48E-10 5.37E-10

SSES - FSAR Table Rev. 0 FSAR Rev. 64 Page 1 of 1 TABLE 2.3-140 1999-2003 SSES RELATIVE DEPOSITION D/Q X/Q ACCUMULATION FOR DEPOSITION (per square meter)

MILES Direction From 0.5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 N

2.57E-08 3.78E-09 1.55E-09 7.35E-10 4.34E-10 1.38E-10 3.29E-11 1.21E-11 6.47E-12 4.06E-12 NNE 3.31E-08 5.13E-09 2.23E-09 1.06E-09 6.23E-10 1.94E-10 4.53E-11 1.67E-11 8.89E-12 5.59E-12 NE 4.05E-08 6.11E-09 2.61E-09 1.27E-09 7.51E-10 2.42E-10 5.93E-11 2.18E-11 1.16E-11 7.31E-12 ENE 7.28E-08 1.13E-08 5.04E-09 2.46E-09 1.46E-09 4.61E-10 1.05E-10 3.68E-11 1.96E-11 1.23E-11 E

3.40E-08 4.96E-09 2.02E-09 9.65E-10 5.76E-10 1.90E-10 4.81E-11 1.77E-11 9.45E-12 5.94E-12 ESE 2.36E-08 3.57E-09 1.52E-09 7.36E-10 4.40E-10 1.46E-10 3.31E-11 1.07E-11 5.71E-12 3.59E-12 SE 3.04E-08 4.62E-09 2.02E-09 9.97E-10 5.98E-10 2.02E-10 4.21E-11 1.15E-11 6.14E-12 3.86E-12 SSE 2.52E-08 3.76E-09 1.60E-09 7.92E-10 4.83E-10 1.73E-10 3.79E-11 1.01E-11 5.38E-12 3.38E-12 S

2.61E-08 4.19E-09 1.97E-09 1.01E-09 6.30E-10 2.44E-10 5.69E-11 1.46E-11 7.80E-12 4.90E-12 SSW 3.58E-08 5.48E-09 2.46E-09 1.24E-09 7.53E-10 2.63E-10 5.84E-11 1.67E-11 8.89E-12 5.59E-12 SW 4.76E-08 7.56E-09 3.56E-09 1.84E-09 1.14E-09 4.28E-10 9.66E-11 2.46E-11 1.31E-11 8.25E-12 WSW 3.14E-08 4.84E-09 2.26E-09 1.21E-09 7.69E-10 3.17E-10 8.93E-11 2.58E-11 1.13E-11 5.54E-12 W

1.29E-08 1.93E-09 8.36E-10 4.17E-10 2.54E-10 9.10E-11 2.22E-11 6.96E-12 3.71E-12 2.33E-12 WNW 9.68E-09 1.40E-09 5.63E-10 2.69E-10 1.60E-10 5.17E-11 1.28E-11 4.71E-12 2.51E-12 1.58E-12 NW 1.67E-08 2.45E-09 9.82E-10 4.57E-10 2.70E-10 8.57E-11 2.06E-11 7.57E-12 4.04E-12 2.54E-12 NNW 2.15E-08 3.19E-09 1.35E-09 6.51E-10 3.81E-10 1.16E-10 2.62E-11 9.63E-12 5.14E-12 3.23E-12

SSES - FSAR Table Rev. 0 FSAR Rev. 71 Page 1 of 1 TABLE 2.3-141 2017-2021 ANNUAL AVERAGE RELATIVE CONCENTRATION (sec/meter

3) AND DEPOSITION (1/meter
2) ESTIMATES AT THE SITE BOUNDARY Relative Concentration (sec/meter3)

AFFECTED SECTOR DISTANCE (MILES)

/Q(1)

/Q DEC(2)

/Q DEC+ DEP(3)

DEPOSITION(4)

N 0.39 1.40E-05 1.40E-05 1.29E-05 4.83E-08 NNE 0.40 1.32E-05 1.31E-05 1.22E-05 5.70E-08 NE 0.53 6.20E-06 6.18E-06 5.61E-06 3.88E-08 ENE 0.86 1.47E-06 1.46E-06 1.29E-06 9.67E-09 E

0.80 7.83E-07 7.80E-07 6.89E-07 4.96E-09 ESE 0.48 1.38E-06 1.38E-06 1.26E-06 1.09E-08 SE 0.34 3.57E-06 3.57E-06 3.33E-06 3.43E-08 SSE 0.34 4.00E-06 3.99E-06 3.73E-06 3.67E-08 S

0.34 3.76E-06 3.75E-06 3.50E-06 2.22E-08 SSW 0.41 7.67E-06 7.65E-06 7.06E-06 3.11E-08 SW 0.41 2.04E-05 2.03E-05 1.87E-05 5.47E-08 WSW 0.63 2.65E-05 2.63E-05 2.36E-05 4.11E-08 W

0.61 1.76E-05 1.75E-05 1.58E-05 2.65E-08 WNW 0.63 1.09E-05 1.08E-05 9.74E-06 1.88E-08 NW 0.46 1.78E-05 1.77E-05 1.62E-05 3.88E-08 NNW 0.40 1.82E-05 1.82E-05 1.68E-05 5.01E-08 1

/Q RELATIVE CONCENTRATION (SEC/M3) 2

/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 3

/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS 4

DEPOSITION RELATIVE DEPOSITION RATE (1/M2)

I I

SSES - FSAR Table Rev. 0 FSAR Rev. 71 Page 1 of 1 TABLE 2.3-142 2017-2021 ATMOSPHERIC DISPERSION ESTIMATES AT SELECTED LOCATIONS AFFECTED SECTOR LOCATION MILES

/Q(1)

/Q DEC(2)

/Q DEC+

DEP(3)

DEPOSITION(4) 12 / WSW Maximum (/Q)

Site Boundary 0.63 2.65E-05 2.63E-05 2.36E-05 4.11E-08 8 / SSE Closest (/Q) Site Boundary 0.34 4.00E-06 3.99E-06 3.73E-06 3.67E-08 16 / NNW Maximum (/Q)

Residence 0.70 9.94E-06 9.89E-06 8.91E-06 2.55E-08 16 / NNW Maximum (D/Q)

Residence 0.70 9.94E-06 9.89E-06 8.91E-06 2.55E-08 7 / SE Maximum (D/Q)

Garden 0.60 1.50E-06 1.50E-06 1.34E-06 1.31E-08 12 / WSW Maximum (D/Q)

Dairy 1.7 5.99E-06 5.92E-06 5.00E-06 8.25E-09 12 / WSW Maximum (D/Q)

Meat Producer 1.7 5.99E-06 5.92E-06 5.00E-06 8.25E-09 3 / NE Riverlands / EIC 0.7 4.16E-06 4.14E-06 3.69E-06 2.49E-08 12 / WSW Tower's Club 0.5 3.74E-05 3.72E-05 3.39E-05 5.97E-08 3 / NE Riverlands /

Garden 0.9 1.57E-06 1.56E-06 1.42E-06 1.07E-08 11 / SW SW Garden 0.5 1.51E-05 1.50E-05 1.37E-05 3.94E-08 1

/Q RELATIVE CONCENTRATION (SEC/M3) 2

/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 3

/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS 4

DEPOSITION RELATIVE DEPOSITION RATE (1/M2)

I I

SSES - FSAR Table Rev. 0 FSAR Rev. 71 Page 1 of 1 TABLE 2.3-143 2017 - 2021 ATMOSPHERIC DISPERSION ESTIMATES AT THE NEAREST RESIDENCE WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES

/Q(1)

/QDEC (2)

/QDEC

+DEP(3)

DEPOSITION(4) 1 N

1.3 2.57E-06 2.55E-06 2.18E-06 7.18E-09 2

NNE 1.0 3.44E-06 3.42E-06 2.98E-06 1.27E-08 3

NE 0.9 2.89E-06 2.88E-06 2.52E-06 1.67E-08 4

ENE 2.1 3.95E-07 3.92E-07 3.24E-07 2.25E-09 5

E 1.6 2.75E-07 2.74E-07 2.31E-07 1.55E-09 6

ESE 0.5 1.30E-06 1.29E-06 1.18E-06 1.01E-08 7

SE 0.6 1.50E-06 1.50E-06 1.34E-06 1.31E-08 8

SSE 0.7 1.34E-06 1.34E-06 1.19E-06 1.10E-08 9

S 1.0 7.24E-07 7.20E-07 6.27E-07 3.63E-09 10 SSW 0.9 2.43E-06 2.42E-06 2.12E-06 8.69E-09 11 SW 1.5 2.90E-06 2.87E-06 2.44E-06 6.42E-09 12 WSW 1.3 8.95E-06 8.86E-06 7.60E-06 1.27E-08 13 W

1.4 4.90E-06 4.84E-06 4.14E-06 6.52E-09 14 WNW 1.1 4.77E-06 4.72E-06 4.10E-06 7.50E-09 15 NW 0.8 7.85E-06 7.78E-06 6.89E-06 1.56E-08 16 NNW 0.7 9.94E-06 9.89E-06 8.91E-06 2.55E-08 1

/Q RELATIVE CONCENTRATION (SEC/M3) 2

/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 3

/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS 4

DEPOSITION RELATIVE DEPOSITION RATE (1/M2)

I I

SSES - FSAR Table Rev. 0 FSAR Rev. 71 Page 1 of 1 TABLE 2.3-144 2017 - 2021 ATMOSPHERIC DISPERSION ESTIMATES AT THE NEAREST GARDEN WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES

/Q(1)

/QDEC(2)

/QDEC

+DEP(3)

DEPOSITION(4) 1 N

3.2 6.69E-07 6.56E-07 5.20E-07 1.52E-09 2

NNE 2.3 9.90E-07 9.79E-07 8.03E-07 3.14E-09 3

NE 2.7 5.66E-07 5.59E-07 4.50E-07 2.69E-09 4

ENE 2.4 3.23E-07 3.20E-07 2.61E-07 1.79E-09 5

E 4.9 4.28E-08 4.21E-08 3.17E-08 1.90E-10 6

ESE 3.1 6.79E-08 6.73E-08 5.32E-08 3.88E-10 7

SE 0.6 1.50E-06 1.50E-06 1.34E-06 1.31E-08 8

SSE 2.9 1.38E-07 1.37E-07 1.09E-07 8.90E-10 9

S 3.5 8.96E-08 8.84E-08 6.91E-08 3.54E-10 10 SSW 1.3 1.42E-06 1.41E-06 1.21E-06 4.79E-09 11 SW 4.2 5.34E-07 5.21E-07 4.01E-07 8.84E-10 12 WSW 1.3 8.95E-06 8.86E-06 7.60E-06 1.27E-08 13 W

3.2 1.28E-06 1.24E-06 9.91E-07 1.36E-09 14 WNW 3.6 7.18E-07 6.97E-07 5.49E-07 8.49E-10 15 NW 2.3 1.61E-06 1.58E-06 1.30E-06 2.63E-09 16 NNW 4.0 5.19E-07 5.05E-07 3.92E-07 8.86E-10 1

/Q RELATIVE CONCENTRATION (SEC/M3) 2

/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 3

/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS 4

DEPOSITION RELATIVE DEPOSITION RATE (1/M2)

I I

SSES - FSAR Table Rev. 0 FSAR Rev. 71 Page 1 of 1 TABLE 2.3-145 2017-2021 ATMOSPHERIC DISPERSION ESTIMATES AT THE NEAREST ANIMAL RAISED FOR MEAT CONSUMPTION WITHIN A 5-MILE RADIUS OF SSES BY SECTOR SECTOR NUMBER AFFECTED SECTOR MILES

/Q(1)

/QDEC (2)

/QDEC

+DEP(3)

DEPOSITION(4) 2 NNE 2.3 9.90E-07 9.79E-07 8.03E-07 3.14E-09 4

ENE 2.4 3.23E-07 3.20E-07 2.61E-07 1.79E-09 5

E 4.5 4.95E-08 4.87E-08 3.70E-08 2.23E-10 10 SSW 1.3 1.42E-06 1.41E-06 1.21E-06 4.79E-09 12 WSW 1.7 5.99E-06 5.92E-06 5.00E-06 8.25E-09 13 W

5.0 6.00E-07 5.78E-07 4.40E-07 5.43E-10 1

/Q RELATIVE CONCENTRATION (SEC/M3) 2

/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 3

/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS 4

DEPOSITION RELATIVE DEPOSITION RATE (1/M2)

I I

SSES - FSAR Table Rev. 0 FSAR Rev. 71 Page 1 of 1 TABLE 2.3-146 2017 - 2021 ATMOSPHERIC DISPERSION ESTIMATES AT ALL DAIRY LOCATIONS NEAR SSES SECTOR NUMBER AFFECTED SECTOR MILES

/Q(1)

/QDEC (2)

/QDEC

+DEP(3)

DEPOSITION(4) 5 E

4.5 4.95E-08 4.87E-08 3.70E-08 2.23E-10 12 WSW 1.7 5.99E-06 5.92E-06 5.00E-06 8.25E-09 13 W

5.0 6.00E-07 5.78E-07 4.40E-07 5.43E-10 1

/Q RELATIVE CONCENTRATION (SEC/M3) 2

/Q DEC DECAYED AND UNDEPLETED, HALF-LIFE 2.26 3

/Q DEC+DEP DECAYED AND DEPLETED, HALF-LIFE 8 DAYS 4

DEPOSITION RELATIVE DEPOSITION RATE (1/M2)

I I

AutoCAD: Figure Fsar 2_3_1.dwg FSAR REV. 65 FIGURE 2.3-1, Rev 47 TORNADO OCCURRENCE AND INTENSITY IN SUSQUEHANNA REGION SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 11 10 9

8 7

6 s 4

3 2

1 n

10 9

8 7

6 s

4 3

2 1

- I 3 I J

3 2

1 1 2 3

2 2

1 1

F M

A 3

4 5 6 7 8 9 F-Scale 0

1 2

3 4

5 6

3 3

2 2

3 2

2 2

3 ts 1

1 1

1 1

2 0

2 0

M J

J A

s 0

N D

MONTHS VI I 3

i 2

2 3

~

3 3

i 3

  • 2 2

2 2

2 2

1 1

1 1

1 1

1 1

1 1

2 0

3 10 11 12 13 14 15 16 17 18 19 20 21 22 23 HOUR OF THE DAY Fug1ta Intensity Classification Wind Speed (MPH}

Oescrfptf on 40-75 Very Weak Tornado (11 gh t damage)73-112 Weak Tomado 113-1S4 Strong Tornado 155-206 Severe Tornado 207-260 Devastin9 Tornado 261-318 Incredible Tornado 319 and higher Inconceivable Tornado

AutoCAD: Figure Fsar 2_3_2.dwg FSAR REV. 65 FIGURE 2.3-2, Rev 47 TP 25 RAINFALL INTENSITY-DURATION FREQUENCY CURVES USDC WB, 1955 SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT IO 0

  • o
  • o ao

&.O

  • .o f...

I

.H

-~ """"'

~ ~

~

,.,., ~

"",-....___........ ~

~... ~

~

~

KRANTOfit,-PPNS'YLYANIA IIOl*lllf

,,_~...,Lr#JS #I, IIIT"""'1 IJr... -

ttrHIII t&l.~ *.,.,,,,,,.,,...ll

== --

~

~

~

~

~

~ ~

""'- ~

ro..

~

~

' ~.

~~

~ ~ '-

................ ~

.,~ ~~ ~

lrt...

~

~

~ ~ ~ -

~ ~

~

~

~ "

~

~ '

le -

IOIO I

I I I I

  • *I INM1i1"tt

Security-Related Information Figure Withheld Under 10 CFR 2.390 FIGURE 2.3-3 TOPOGRAPHY WITHIN 5 MILES SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT

AutoCAD: Figure Fsar 2_3_4_1.dwg FSAR REV. 65 FIGURE 2.3-4-1, Rev 47 Sh. 1 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

....J

(/)

~ 1900 w

§! 1700

~ 1500 5 1300

~

~ 1100 w

900 700 NNE 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES) 2500 2300 2100

....J

(/)

~ 1900 w

§! 1700

~ 1500 5 1300

~

~ 1100 w

900 700 NE 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_2.dwg FSAR REV. 65 FIGURE 2.3-4-2, Rev 47 (Cont'd) Sh. 2 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500-2300 2100

....J

(/)

~ 1900 w

1700

~ 1500 5 1300

~

G'.i 1100

....J w

900 700 ENE 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES) 2500 2300 2100

....J

(/)

~ 1900 w

1700

~ 1500 5 1300

~

~ 1100 w

900 700 E

500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_3.dwg FSAR REV. 65 FIGURE 2.3-4-3, Rev 47 Sh. 3 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

...J U)

!: 1900 w
1700

~ 1500


5 1300

~

G'.i 1100

...J w

900 700 ENE 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES) 2500 2300 2100

...J U)

!: 1900 w

> i 1700 fil 1500 5 1300

~

~ 1100 w

900 700 SE 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_4.dwg FSAR REV. 65 FIGURE 2.3-4-4, Rev 47 Sh. 4 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

....J

(/)

!: 1900 w

0 CD 1700

<(

w 1500 w

LL 5 1300

~

~ 1100 w

900 700 SSE 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES) 2500 2300 2100

....J

(/)

!: 1900 w

> i 1700

~ 1500 5 1300

~

~ 1100 w

900 700 s

500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_5.dwg FSAR REV. 65 FIGURE 2.3-4-5, Rev 47 Sh. 5 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

....J en

~ 1900 w

> i 1700

~ 1500 6 1300

~

~ 1100 w

900 700 SSW 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES) 2500 2300 2100

....J en

~ 1900 w

> i 1700

~ 1500 6 1300

~

~ 1100 w

900 700 SW 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_6.dwg FSAR REV. 65 FIGURE 2.3-4-6, Rev 47 Sh. 6 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

....J

(/)

?! 1900 w

> s! 1700

~ 1500 5 1300

~

~ 1100 w

900 700 WSW 500 0

5 10 15 20 25 30 35 40 45 50 2500 DISTANCE (MILES) 2300 2100

....J

(/)

?! 1900 w

0 CD 1700

<(

w 1500 w

LL 5 1300

~

~ 1100 w

900 700 w

500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_7.dwg FSAR REV. 65 FIGURE 2.3-4-7, Rev 47 Sh. 7 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

...J Cl)

i: 1900 w

> i 1700

~ 1500

-5 1300

~

~ 1100 w

900 700 WNW 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES) 2500 2300 2100

...J Cl)

~ 1900 w

§; 1700

~ 1500

-5 1300

~

~ 1100 w

900 700 NW 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_4_8.dwg FSAR REV. 65 FIGURE 2.3-4-8, Rev 47 Sh. 8 of 8 MAXIMUM TERRAIN ELEVATION VERSUS DISTANCE BY SECTOR SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 2500 2300 2100

....J

(/)

i: 1900 w

0 CD 1700

<(

t:i 1500 w

LL 6 1300

~

G'.i 1100

....J w

900 700 NNW 500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE {MILES) 2500 2300 2100

....J

(/)

i: 1900 w

0 CD 1700

<(

t:i 1500 w

LL z 1300 0

~

G'.i 1100

....J w

900 700 N

500 0

5 10 15 20 25 30 35 40 45 50 DISTANCE (MILES)

AutoCAD: Figure Fsar 2_3_5.dwg FSAR REV. 65 FIGURE 2.3-5, Rev 54 SCHEMATIC OF INSTRUMENTATION SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT NOTE:

1. WIND VARIABILITY IS NOT A DIRECT MEASUREMENT AT THE TOWER, BUT TRANSLATED AT THE MAINFRAME IN THE TOWER BUILDING FROM WD DATA.

954' 850' 686' 653' 623' 590'


- T, WS, WO, WV


- T, D, WS, WD, WV


p WS,WD 300' PRIMARY TOWER 1 Om 8/U TOWER KEY TO INSTRUMENTATION T

= TEMPERATURE D

= DEW POINT TEMPERATURE WS = WIND SPEED WO= WIND DIRECTION WV= WIND VARIABILITY (NOTE 1)

P

= PRECIPITATION

Percent Probability ONE HOUR DIRECTION INDEPENDENT X/Q AT THE EAB (WEIGHTED AVERAGE OF 1999, 2000, 2001, 2002, 2003 CALCULATIONS)

AutoCAD: Figure Fsar 2_3_6.dwg FSAR REV. 65 FIGURE 2.3-6, Rev 1 SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 100.00%

10.00%

1.00%

0.10%

0.01%

1.00E-05 Figure 2.3 1 Hour Direction Independent X/Q at the EAB (Weighted Average of 1999, 2000, 2001, 2002, 2003 Calculations) 1.3E-4

..... ~

---.i'--,

6.5E-4 I\

\

\

\

\

  • 1.00E-04 1.00E-03 X/Q (sec/rrl)

I I I I I I

I 1.00E-02

ONE HOUR DIRECTION DEPENDENT X/Q VALUES AT THE EAB (WEIGHTED AVERAGE OF 1999, 2000, 2001, 2002, 2003 CALCULATIONS)

AutoCAD: Figure Fsar 2_3_7.dwg FSAR REV. 65 FIGURE 2.3-7, Rev 1 SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT

.c cu

..c 0...

a. -

C:

a, u...

a,

a.

100.00%

10.00%

1.00%

0.10%

Figure 2.3 1 hr Direction Dependent X/Q Values at the EAB (Weighted Average of 1999, 2000, 2001, 2002, 2003 Calculations)

',...,. ' I

'\..I,11

,1... 1..

r, r, ' ',, 'I',,, I'".,,

OJ

.-.~
~:~:{E;:=.... -=
  • ,-,._.+~it-1-1-j

--~ -

~

  • ~-
  • \-~;

/~-c.>,:

    • -,,,rJ*:, -*:*~t...._... -
  • ~:-~*-1 ~.,...._

.,...,_i,

"* I

  • -...:::: ~..;i.--._ "'

~~, \

> c,>

  • -*~* I'+

.:-~.,......

rn ' '

  • ~ * '~ ~-** '"" "'* !'--.'~~*~*....,.

....~ '\,

. *~...

  • ---**~..

",*~ ~

,. ~*-

,,~,

~...,

8.3E-041

~

  • *., '" 1,

\

'\. "'- '- ~*

,11:: I',.'-

11.,... -

"-~ ',

~~I -,~~r-'\. "-1" "1 II.

~~ *~ 1,1~~ \

  • Jt IZlr

~: ~--

  • ~. -.,..-r="' ;;*..

~ "

,, \

,!I

\ \\\\

~ '

.... \ll

\ \\\\

  • ,... \ \\\\

0.01%

1.00E-05 1.00E-04

'\~"\~~ ~I\J \ls 1.00E-03 X/Q (sec/m3) 1.00E-02

--+-N

~NNE

~NE

~ENE

-.-E

-+-ESE


rSE

-SSE

-s

~SSW

~SW

~WSW

~w

-.-WNW

~NW


rNNW

ONE HOUR DIRECTION DEPENDENT X/Q VALVES AT THE LPZ (WEIGHTED AVERAGE OF 1999, 2000, 2001, 2002, 2003 CALCULATIONS)

AutoCAD: Figure Fsar 2_3_8.dwg FSAR REV. 65 FIGURE 2.3-8, Rev 1 SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT

>, =
c I'll

.Cl 0...

D. -

C cu u...

cu D.

100.00%

10.00%

1.00%

0.10%

0.01%

1.00E-07 I

Figure 2.3-8 -1 Hour Direction Dependent X/Q Values at the LPZ (Weighted Average of 1999, 2000, 2001, 2002, 2003 Calculations)

~

~

-..., ~

~

~

~

1.00E-06 h I... 'r, ~ ~

...,,. A

~

J

't,.

~

'ON ~

r'\

"\

~

1.00E-05 X/Q (sec/m3)

\

""""'-...it l"'il '

~

r-2 ~,

..... \.\

9.6E-5

~ -

~ -

'i ~' :-... "

I\.

~

--.... h' ~- '\

"11: ~

l

~

~ 'l * ~ ' " ~

~

~,

~

u

\

I

\. ')( ~ 1 " ' '

~ "

~~ ( '(

~ l 'f\

1 l

'._\ ~\ \ "--, ' ~

ll..._ i ~

1.00E-04 1.00E-03

---N

---1/4-NNE

~

NE

_._ENE


E

-+-ESE

--SE

--SSE

---<>-S SSW

---1/4-SW

~WSW

--.-w

---e-wNW

-+-NW

--NNW

ONE HOUR DIRECTION DEPENDENT X/Q AT THE LPZ (WEIGHTED AVERAGE OF 1999, 2000, 2001, 2002, 2003 CALCULATIONS)

AutoCAD: Figure Fsar 2_3_9.dwg FSAR REV. 65 FIGURE 2.3-9, Rev 1 SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT

~

.a

..8 e

a. -

C: § a,

a.

100.00%

10.00%

1.00%

0.10%

0.01%

1.0E-07 Figure 2.3 1 Hour Direction Independent X/Q at the LPZ (weighted average of 1999, 2000, 2001, 2002, 2003 Calculations) 1.0E-06 I -

1.0E-05 X/Q (sec m3) 7.6E-6

~r---.._

~~

7.0E-5

\

\

\

\ '

I I

\

\

~

1.0E-04 I

I 1.0E-03

INTERPOLATED X/Q VALUES AT THE LPZ (WEIGHTED AVERAGE OF 1999, 2000, 2001, 2002, 2003 CALCULATIONS)

AutoCAD: Figure Fsar 2_3_10.dwg FSAR REV. 65 FIGURE 2.3-10, Rev 1 SUSQUEHANNA STEAM ELECTRIC STATION UNITS 1 & 2 FINAL SAFETY ANALYSIS REPORT 0.001 0.0001 0.00001 0.000001 0.0000001 Figure 2.3 Interpolated X/Q Values at the LPZ (Weighted Average of 1999, 2000, 2001, 2002, 2003 Calculations)

(0.5% Calculated Maximum 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Value in the ENE plotted at 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, Calculated Maximum Average Annual in the ENE plotted l9.6E-05I at 8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> 4.9E-05

  • -~

,___ 3.5E-05

~._

1.7E-05I 7.6E-06I I"--..._

4.BE-06 6.1 E-06 I

3.BE-06

  • ...... *-r--

2.3E-06I

--i--.,._.


r---. -

(50% Calculated 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Value Plotted at 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, Calculated Annual Average Plotted at 8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> 10 100 Averaging Time (hours)

~

~----

1.7E-06

........ ~

1.1 E-06I

w.

4.7E-07 1000 10000 Interpolated Values (per RG 1.145)

-calculated Direction Dependent 0.5% 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

& Annual Average


.- Cal cu lated 50% 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

& Annual Averages (Direction Independent)

Interpolated Values (per RG 1.145)